At least 901 records · Page 50

Which parameters might help to predict an impact on reactivity for mixed fissile units in a storage array?

Several studies have already been performed on mixed fissile units in storage arrays and concluded that the neutron spectrum of the fissile material, the shape of fissile units, the interstitial moderation and structural materials may have an impact on reactivity. For this paper, calculations are performed on a simplified infinite planar array with one level of fissile material units axially reflected by concrete. Fissile material is modelled by a cylinder shape centered in the array mesh selected (120 cm height and 60 cm pitch). Either air or interstitial moderation by water is modelled between the fissile units. Three parameters are studied: the fissile materials (with various moderation conditions), the cylinder dimension and the nature of the structural material. The main following conclusions can be drawn from these calculations. First, for several mixed-array cases, air-spaced mixed arrays present a high increase on reactivity whereas interstitial moderation between fissile units leads to no or little impact. Secondly, fissile unit shapes do not explain directly the mixing impact on reactivity. Thirdly, structural materials have an important impact on reactivity in mixed array (either an increase or a decrease) due to their absorbing and/or moderating properties either when air or interstitial moderation are modelled between fissile units. Fourthly, no simple parameter was found to predict the impact on reactivity of mixed array in all studied configurations. However, a comparison of different neutron spectrum parameters can help to predict the absence or potential presence of a 'mixing effect'. Indeed, if all parameters are similar, no 'mixing effect' is observed. But, if these parameters present differences, there might be a 'mixing effect'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational modeling study of the radial line slot antenna microwave plasma source with comparisons to experiments

The radial line slot antenna plasma source is a high-density microwave plasma source comprising a high electron temperature source region within the plasma skin depth from a coupling window and low electron temperature diffusion region far from the window. The plasma is typically comprised of inert gases like argon and mixtures of halogen or fluorocarbon gases for etching. Following the experimental study of Tian et al.[J. Vac. Sci. Technol. A 24, 1421 (2006)], a two-dimensional computational model is used to describe the essential features of the source. A high density argon plasma is described using the quasi-neutral approximation and coupled to a frequency-domain electromagnetic wave solver to describe the plasma-microwave interactions in the source. The plasma is described using a multispecies plasma chemistry mechanism developed specifically for microwave excitation conditions. The plasma is nonlocal by nature with locations of peak power deposition and peak plasma density being very different. The spatial distribution of microwave power coupling depends on whether the plasma is under- or over-dense and is described well by the model. The model predicts the experimentally observed low-order diffusion mode radial plasma profiles. The trends of spatial profiles of electron density and electron temperature over a wide range of power and pressure conditions compare well with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE BHB STARS IN THE SURVEY FIELDS OF RODGERS ET AL. (1993): NEW OBSERVATIONS AND COMPARISONS WITH OTHER RECENT SURVEYS

We study blue horizontal branch (BHB) and RR Lyrae stars in the Rodgers et al. fields and compare their velocity and density distributions with other surveys in the same part of the sky. Photometric data are given for 176 early-type stars in the northern field. We identify fourteen BHB stars and four possible BHB stars, and determine the selection efficiency of the Century survey, the HK survey, and the SDSS survey for BHB stars. We give light curves and {gamma} radial velocities for three type ab RR Lyrae stars in the northern field; comparison with the nearby LONEOS survey shows that there is likely to be an equal number of lower-amplitude type ab RR Lyrae stars that we do not find. There are therefore at least twice as many BHB stars as type ab RR Lyrae stars in the northern field-similar to the ratio in the solar neighborhood. The velocity distribution of the southern field shows no evidence for an anomalous thick disk that was found by Gilmore et al.; the halo velocity peaks at a slightly prograde rotational velocity but there is also a significant retrograde halo component in this field. The velocity distribution in the northern field shows no evidence of Galactic rotation for |Z| {>=} 4 kpc and a slight prograde motion for |Z| < 4 kpc. The space densities of BHB stars in the northern field agree with an extrapolation of the power-law distribution recently derived by de Propris et al. For |Z| < 4 kpc, however, we observe an excess of BHB stars compared with this power law. We conclude that these BHB stars mostly belong to a spatially flattened, non-rotating inner halo component of the Milky Way in confirmation of the Kinman et al. analysis of Century survey BHB stars.

79 ASTRONOMY AND ASTROPHYSICS↗

The Shewanella Federation: Functional Genomic Investigations of Dissimilatory Metal-Reducing Shewanella

Generation and validation of a Shewanella oneidensis MR-1 clone set for protein expression and phage display. An ORF clone set for S. oneidensis was created using the lambda recombinase system. ORFs within entry vectors in this system can be readily transferred into multiple destination vectors, making the clone set a useful resource for research groups studying this microorganism. To establish that the S. oneidensis clone set could be used for protein expression and functional studies, three sets of ORFs were examined for expression of His-tag proteins, expression of His/GST-tag proteins, or for effective display on phage. A total of 21 out of 30 (70%) predicted two-component transcriptional regulators from S. oneidensis were successfully expressed in the His-tag format. The use of the S. oneidensis clone set for functional studies was tested using a phage display system. The method involves the fusion of peptides or proteins to a coat protein of a bacteriophage. This results in display of the fused protein on the exterior of the phage, while the DNA encoding the fusion resides within the virion. The physical linkage between the displayed protein and the DNA encoding it allows screening of vast numbers of proteins for ligand-binding properties. With this technology, a phage clone encoding thioredoxin TrxA was isolated from a sub-library consisting of 80 clones. It is evident that the S. oneidensis clone set can be used for expression of functional S. oneidensis proteins in E. coli using the appropriate destination vectors. Characterization of ArcA. In Escherichia coli, metabolic transitions between aerobic and anaerobic growth states occur when cells enter an oxygen-limited condition. Many of these metabolic transitions are controlled at the transcriptional level by the activities of the global regulatory proteins ArcA (aerobic respiration control) and Fnr (fumarate nitrate regulator). A homolog of ArcA (81% amino acid sequence identity) was identified in S. oneidensis MR-1, and arcA mutants with MR-1 as the parental strain were generated. Phenotype characterization showed the arcA deletion mutant grew slower than the wild-type and was hypersensitive to H2O2 stress. Microarray analysis indicated that S. oneidensis ArcA regulates a large number of different genes from that in E. coli although they do have overlapping regulatory functions on a small set of genes. The S. oneidensis arcA gene was also cloned and expressed in E. coli. The ArcA proteins from the wild-type and a point mutant strains (D54N) were purified and their DNA binding properties were analyzed by electrophoretic motility shift (EMS) and DNase I footprinting assays. The results indicate that phosphorylated ArcA proteins bind to a DNA site similar in sequence to the E. coli ArcA binding site. The common feature of the binding sites is the presence of a conserved 15 base pair motif that contains 2-3 mismatches when compared to the E. coli ArcA-P consensus binding motif. Genome scale computational predictions of binding sites were also performed and 331 putative ArcA regulatory targets were identified. Therefore, the regulation of aerobic/anaerobic respiration may be more complex than it was expected in S. oneidensis. A high-throughput percentage-of-binding strategy to measure binding energies in DNA–protein interactions. Based on results of studies on ArcA of S. oneidensis, we developed a high-throughput approach to measure binding energies in DNA-protein interactions, which enables a more precise prediction for DNA-binding sites in genomes. With this approach, the importance of each position within the ArcA-P binding site was quantitatively established by characterizing the interaction between Shewanella ArcA-P and a series of mutant promoter DNAs, whereby each position in the binding site was systematically mutated to all possible single nucleotide changes. The results of the fine mapping were used to create a position-specific energy matrix (PEM) that was used for a genome-scale prediction of 45 ArcA-P sites in Shewanella. A further examination suggests that this prediction is >81% consistency with in vivo gene regulation according to microarray studies and >92% (13/14) accuracy in comparison with published in vitro gel shift validation binding assays. In addition, this study predicted 27 ArcA-P sites for 15 published E. coli ArcA-P footprinted DNAs, and 24 of them were found exactly within the footprinting protected regions and the other three sites fall into the regions that were not examined by footprinting assays. This is the first report showing that footprinting protected regions can be effectively predicted by starting from a single known transcription factor binding site. Finally, the predicted H. influenzae ArcA-P sites correlate well with in vivo regulation determined by a microarray analysis in that the eight predicted binding sites with the most favorable ΔG scores all exhibit ArcA dependent gene regulation.

59 BASIC BIOLOGICAL SCIENCES↗

STREAMS guidelines: standards for technical reporting in environmental and host-associated microbiome studies

The interdisciplinary nature of microbiome research, coupled with the generation of complex multi-omics data, makes knowledge sharing challenging. The Strengthening the Organization and Reporting of Microbiome Studies (STORMS) guidelines provide a checklist for the reporting of study information, experimental design and analytical methods within a scientific manuscript on human microbiome research. Here, in this Consensus Statement, we present the standards for technical reporting in environmental and host-associated microbiome studies (STREAMS) guidelines. The guidelines expand on STORMS and include 67 items to support the reporting and review of environmental (for example, terrestrial, aquatic, atmospheric and engineered), synthetic and non-human host-associated microbiome studies in a standardized and machine-actionable manner. Based on input from 248 researchers spanning 28 countries, we provide detailed guidance, including comparisons with STORMS, and case studies that demonstrate the usage of the STREAMS guidelines. In conclusion, STREAMS, like STORMS, will be a living community resource updated by the Consortium with consensus-building input of the broader community.

59 BASIC BIOLOGICAL SCIENCES↗

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Semiquantitative and Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging Measurements Predict Radiation Response in Cervix Cancer

Purpose: To evaluate semiquantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements in predicting the response to radiotherapy in cervix cancer. Methods and Materials: Patients with cervix cancer treated radically with chemoradiotherapy had DCE-MRI at three time points: before starting treatment, after 2 weeks of radiotherapy, and in the 5th week of radiotherapy. Semiquantitative measurements obtained from the signal intensity vs. time plots included arrival time of contrast, the slope and maximum slope of contrast uptake, time for peak enhancement, and the contrast enhancement ratio (CER). Pharmacokinetic modeling with a modeled vascular input function was used for the quantitative measurements volume transfer constant (K{sup trans}), rate constant (k{sub ep}), fraction plasma volume (fPV), and the initial area under gadolinium-time curve. The correlation of these measurements at each of the three time points with radiologic tumor response was investigated. Results: Thirteen patients had a total of 38 scans. There was no correlation between the DCE-MRI measurements and the corresponding tumor volumes. A statistically significant correlation with percentage tumor regression was shown with the pretreatment DCE-MRI semiquantitative parameters of peak time (p = 0.046), slope (p = 0.025), maximum slope (p = 0.046), and CER (p = 0.025) and the quantitative parameters K{sup trans} (p = 0.043) and k{sub ep} (p = 0.022). Second and third scan measurements did not show any correlation. Conclusions: This is the first study to show that pretreatment DCE-MRI quantitative parameters predict the radiation response in cervix cancer. These measurements may allow a more meaningful comparison of DCE-MRI studies from different centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Simulation of Natural Circulation Cooling System with Salt Working Fluid Using SAM

Liquid salt-cooled reactors, such as the Fluoride Salt-Cooled High-Temperature Reactor (FHR), offer passive decay heat removal through natural circulation using Direct Reactor Auxiliary Cooling System (DRACS) loops. The behavior of such systems should be well-understood through performance analysis. The advanced system thermal-hydraulics tool System Analysis Module (SAM) from Argonne National Laboratory has been selected for this purpose. The work presented here is part of a larger study in which SAM modeling capabilities are being enhanced for the system analyses of FHR or Molten Salt Reactors (MSR). Liquid salt thermophysical properties have been implemented in SAM, as well as properties of Dowtherm A, which is used as a simulant fluid for scaled experiments, for future code validation studies. Additional physics modules to represent phenomena specific to salt-cooled reactors, such as freezing of coolant, are being implemented in SAM. This study presents a useful first benchmark for the applicability of SAM to liquid salt-cooled reactors: it provides steady-state and transient comparisons for a salt reactor system. A RELAP5-3D model of the Mark-1 Pebble-Bed FHR (Mk1 PB-FHR), and in particular its DRACS loop for emergency heat removal, provides steady state and transient results for flow rates and temperatures in the system that are used here for code-to-code comparison with SAM. The transient studied is a loss of forced circulation with SCRAM event. To the knowledge of the authors, this is the first application of SAM to FHR or any other molten salt reactors. While building these models in SAM, any gaps in the code’s capability to simulate such systems are identified and addressed immediately, or listed as future improvements to the code.

Ahmed, K. K.↗

Exploring poly-crystallization in semiconductors through assumption-less growth simulations: CdTe/CdS case study

Crystal growth is a complex process with far-reaching implications for high-performance materials across various fields. Recent advancements in structural analysis methods such as polyhedral template matching, which allows semiconductor-specific analysis, coupled with simulation technology, have enabled the comprehensive study of crystallization dynamics in semiconductors. However, the exploration of polycrystalline semiconductors created with minimal external intervention of the crystallization processes is relatively uncharted in comparison with metals. In this study, we employ molecular dynamics to simulate the growth of polycrystalline CdTe/CdS with the assumptions of classical mechanics, a Stillinger–Weber potential, an amorphous substrate, and common vapor growth conditions to allow the polycrystalline structures to evolve naturally. Post-simulation, we identify and analyze impactful structures and events, comparing them to theory and experiment to gain insight into various modes of crystallization dynamics. Two research questions guided the study: (1) How realistic are assumption-less simulated polycrystalline semiconductor structures? (2) To what extent can the approach provide insight into crystallization? The simulations, performed with minimal external control, yield polycrystalline structures mirroring experimental findings. The analysis reveals key crystallization insights, such as the role of amorphous atoms in the transition from nucleation to grain growth and the transformative impact of single events, such as dislocations, on crystallization dynamics. The method paves the way for reproducing and analyzing realistic polycrystalline semiconductor structures with minimal simulation assumptions across various growth modes.

Abdullah, Sharmin↗

Thermal Ablation of Lung Tissue: In Vivo Experimental Comparison of Microwave and Radiofrequency

This study was designed to compare feasibility, safety, and effectiveness of microwave (MW) ablation versus radiofrequency (RF) ablation of lung tissue in a rabbit model. Twenty New Zealand White rabbits were submitted to MW (n = 10, group A) or RF ablation (n = 10, group B). The procedures were performed with a prototype MW ablation device with a 1.6-cm radiating section antenna (Valleylab MW Ablation System) and with a 2-cm exposed-tip RF electrode (Cool-tip RF Ablation System). At immediate computed tomography increase in density, maximum diameters (D1-D3) of ablation zones were measured and ablation volume was calculated. Histopathologic assessment was performed 3 and 7 days after the procedure. Technical success was achieved in nine of 10 rabbits in each group. One death occurred in group B. Complications included pneumothorax (group A, n = 4; group B, n = 4), abscess (group A, n = 1; group B, n = 1), and thoracic wall burn (group A, n = 4). No significant differences were demonstrated in attenuation increase (P = 0.73), dimensions (P = 0.28, 0.86, 0.06, respectively, comparing D1-D3) and volume (P = 0.17). At histopathology, ablation zones were similar, with septal necrosis, edema, hemorrhage, and peripheral lymphocytic infiltrate. Complete thrombosis of more than 90% of vessels up to 2 mm in diameter was depicted at the periphery of the ablation zone in group A specimens. In group B specimens, complete thrombosis was depicted in 20% of vessels. Feasibility and safety of MW and RF ablation are similar in a lung rabbit model. MW ablation produces a greater damage to peripheral small vessels inducing thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving energy efficiency via smart building energy management systems. A comparison with policy measures

In this study, to foster the transition to more sustainable energy systems, policymakers have been approving measures to improve energy efficiency as well as promoting smart grids. In this setting, building managers are encouraged to adapt their energy operations to real-time market and weather conditions. Yet, most fail to do so as they rely on conventional building energy management systems (BEMS) that have static temperature set points for heating and cooling equipment. In this paper, we investigate how effective policy measures are at improving building-level energy efficiency compared to a smart BEMS with dynamic temperature set points. To this end, we present an integrated optimisation model mimicking the smart BEMS that combines decisions on heating and cooling systems operations with decisions on energy sourcing. Using data from an Austrian and a Spanish building, we find that the smart BEMS results in greater reduction in energy consumption than a conventional BEMS with policy measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THE ACS SURVEY OF GLOBULAR CLUSTERS. XIII. PHOTOMETRIC CALIBRATION IN COMPARISON WITH STETSON STANDARDS

In this study we compare the photometric data of 34 Milky Way globular clusters, observed within the Advanced Camera for Surveys (ACS) Treasury Program (PI: A. Sarajedini) with the corresponding ground-based data, provided by the Photometric Standard Field Catalogs of Stetson. We focus on the transformation between the Hubble Space Telescope/ACS F606W to V-band and F814W to I-band only. The goal is to assess the validity of the filter transformation equations by Sirianni et al. with respect to their dependence on metallicity, horizontal branch morphology, mass, and integrated (V – I) color of the various globular clusters. The transformation equations as recommended by Sirianni et al. are based on synthetic photometry, were mostly tested on NGC 2419, and may introduce additional uncertainties when applied to different stellar populations. Such a dependence is expected due to the fact that the transformation equations are based on the observations of only one globular cluster, i.e., NGC 2419. Surprisingly, the correlation between offset and metallicity is found to be weak, with a low level significance. The correlation between offset and horizontal branch structure, as well as total cluster mass is still weaker. Based on the available data we do not find the photometric offset to be linked to multiple stellar populations, e.g., as found in NGC 0288, NGC 1851, and NGC 5139. The results of this study show that there are small systematic offsets between the transformed ACS- and observed ground-based photometry, and that these are only weakly correlated, if at all, with various cluster parameters and their underlying stellar populations. As a result, investigators wishing to transform globular cluster photometry from the Sirianni et al. ground-based V, I system onto the Stetson system simply need to add –0.040 (±0.012) to the V magnitudes and –0.047 (±0.011) to the I magnitudes. This in turn means that the transformed ACS V – I colors match the ground-based values from Stetson to within ∼0.01 mag.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonperturbative comparison of QCD effective charges

We study the nonperturbative behavior of two versions of the QCD effective charge, one obtained from the pinch technique gluon self-energy, and one from the ghost-gluon vertex. Despite their distinct theoretical origin, due to a fundamental identity relating various ingredients appearing in their respective definitions, the two effective charges are almost identical in the entire range of physical momenta, and coincide exactly in the deep infrared, where they freeze at a common finite value. Specifically, the dressing function of the ghost propagator is related to the two form factors in the Lorentz decomposition of a certain Green's function, appearing in a variety of field-theoretic contexts. The central identity, which is valid only in the Landau gauge, is derived from the Schwinger-Dyson equations governing the dynamics of the aforementioned quantities. The renormalization procedure that preserves the validity of the identity is carried out, and various relevant kinematic limits and physically motivated approximations are studied in detail. A crucial ingredient in this analysis is the infrared finiteness of the gluon propagator, which is inextricably connected with the aforementioned freezing of the effective charges. Some important issues related to the consistent definition of the effective charge in the presence of such a gluon propagator are resolved. We finally present a detailed numerical study of a special set of Schwinger-Dyson equations, whose solutions determine the nonperturbative dynamics of the quantities composing the two effective charges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to subhourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

accuracy↗

On the energy of the 3.5-eV level in {sup 229}Th

Values determined in several studies for the first isomeric state of {sup 229}Th as 3.5(10), 3.4(18), 5.5(10), and 7.6(5) eV differ markedly from one another. A comparison of the first two studies that was performed in the present article indicates that there is a systematic error in the energies of the transitions in {sup 229}Th. It is shown that each of the first two values is dependent on the placement or energy of only one transition (or on both of these two factors). The third value, that of 5.5(10) eV, is not independent, since it is a result of rather complicated calculations for the scheme of energy levels in {sup 229}Th with allowance for the first two studies. It is shown that the accuracy in determining the error in 7.6(5) eV is likely to be exaggerated. It is concluded that the energy of the 3.5-eV state ranges between 0 and 15 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗