Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Computation of Direct Sensitivities of Spatial Multibody Systems With Joint Friction

Abstract Friction exists in most mechanical systems and may have a major influence on the dynamic performance of the system. The incorporation of friction in dynamic systems has been a subject of active research for several years owing to its high nonlinearity and its dependence on several parameters. Consequently, optimization of dynamic systems with friction becomes a challenging task. Gradient-based optimization of dynamical systems is a prominent technique for optimal design and requires the computation of model sensitivities with respect to the design parameters. The novel contribution of this paper is the derivation of the analytical methodology for the computation of direct sensitivities for smooth multibody systems with joint friction using the Lagrangian index-1 formulation. System dynamics have been computed using two different friction models; the Brown and McPhee, and the Gonthier et al. model. The methodology proposed to obtain model sensitivities has also been validated using the complex finite difference method. A case study has been conducted on a spatial multibody system to observe the effect of friction on the dynamics and model sensitivities, compare sensitivities with respect to different parameters and demonstrate the numerical and validation aspects. Since design parameters can have very different magnitudes and units, the sensitivities have been scaled with the parameters for comparison. Finally, a discussion has been presented on the interpretation of the case study results. Due to the incorporation of joint friction, ‘jumps’ or discontinuities are observed in the model sensitivities akin to those observed for hybrid dynamical systems.

Engineering↗

Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography

Purpose: The noise variance versus spatial resolution relationship in differential phase contrast (DPC) projection imaging and computed tomography (CT) are derived and compared to conventional absorption-based x-ray projection imaging and CT. Methods: The scaling law for DPC-CT is theoretically derived and subsequently validated with phantom results from an experimental Talbot-Lau interferometer system. Results: For the DPC imaging method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both in theory and experimental results, in DPC-CT the noise variance scales with spatial resolution following an inverse linear relationship with fixed slice thickness. Conclusions: The scaling law in DPC-CT implies a lesser noise, and therefore dose, penalty for moving to higher spatial resolutions when compared to conventional absorption-based CT in order to maintain the same contrast-to-noise ratio.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗

Super Resolution for Renewable Energy Resource Data With Wind From Reanalysis Data (Sup3rWind) and Application to Ukraine [Slides]

In this work we present a novel deep learning-based downscaling method, using generative adversarial networks (GANs), for generating high-resolution wind resource data from ECMWF Reanalysis v5 data (ERA5). We show that by training a GAN model on ERA5, as opposed to coarsened high-resolution data, we achieve results that are competitive with conventional dynamical downscaling. This GAN-based downscaling method additionally reduces computational costs over dynamical downscaling by two orders of magnitude. All GANs are trained on data sampled from CONUS, selected to provide a diverse sampling of terrain conditions, and validated on observational data along with data held out from training. This cross-validation shows low error and high correlations with observations and excellent agreement with hold out data across physical distributions. Our approach is finally used to downscale 30km hourly ERA5 to 2-km 5-minute wind data, for January 2000 through December 2023, at multiple hub heights, over Ukraine, Moldova, and part of Romania. Comparisons against observational data from Meteorological Assimilation Data Ingest System (MADIS) and multiple wind farms show the same level of performance as for CONUS validation. This 24 year data record is the first member of the "super resolution for renewable energy resource data with wind from reanalysis data" dataset (Sup3rWind).

17 WIND ENERGY↗

Genesis Mission-Enabled Secure AI to Fortify Energy Process Safety (Genesis-SAFE)

Argonne National Laboratory is supporting the U.S. Department of Transportation’s (USDOT’s) Bureau of Transportation Statistics (BTS) with collaborative research on development and application of privacy preserving AI frameworks that leverage unmatched AI expertise and secure computing resources made available through the U.S. Genesis Mission1 . This research advances U.S. energy security goals by supporting a safe offshore energy industry with secure, domain-specific AI tools to analyze confidential industry datasets collected by BTS to rapidly improve identification of hazards, precursors, and systemic safety risks in high-risk operational environments. The staged, security-first approach begins with development and testing of Argonne’s Genesis Mission-enabled Secure AI to Fortify Energy Process Safety (Genesis-SAFE) framework within Argonne’s accredited secure computing enclave (ABLE) leveraging Argonne’s AI scientific assistant substrate (AISAC). Methods to build synthetic datasets were developed together with BTS for use in preparing synthetic datasets that can be used to validate data containment, governance, and security controls in the ABLE environment. Future research directions would focus on applying the Genesis-SAFE framework to CIPSEA-protected datasets entirely within ABLE to support confidentiality-preserving analysis of safety risks, trends, and contributing factors.

Kim, Hyekyung [Argonne National Laboratory (ANL), ↗

Lighting application efficacy: A framework for holistically measuring lighting use in buildings

Lighting consumes significant energy in buildings, but current measurements of lighting efficiency are inadequate in capturing the spatial and temporal effectiveness of light. The most widely used lighting energy efficiency measure, luminous efficacy, quantifies the amount of light generated by individual light sources. While luminous efficacy provides manufacturers and designers with a useful metric for quantifying the energy efficiency of individual lighting devices, it does not fully address the use of lighting in architectural spaces. Instead, application efficacy, the relationship between the electrical power consumed by lighting hardware and the amount of light that contributes to the visual perception of building occupants, must be measured. Here, we propose a framework for calculating lighting application efficacy (LAE) based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into occupants’ eyes, and the process of visual perception. The LAE framework will include the development of computational methods for estimating the proportion of emitted light that is directed to task areas and areas corresponding to occupants’ visual fields using ray-tracing lighting design software. Future modeling and validation work will quantify energy efficiency of buildings.

Durmus, Dorukalp↗

Calibration verification for stochastic agent-based disease spread models

Accurate disease spread modeling is crucial for identifying the severity of outbreaks and planning effective mitigation efforts. To be reliable when applied to new outbreaks, model calibration techniques must be robust. However, current methods frequently forgo calibration verification (a stand-alone process evaluating the calibration procedure) and instead use overall model validation (a process comparing calibrated model results to data) to check calibration processes, which may conceal errors in calibration. In this work, we develop a stochastic agent-based disease spread model to act as a testing environment as we test two calibration methods using simulation-based calibration, which is a synthetic data calibration verification method. The first calibration method is a Bayesian inference approach using an empirically-constructed likelihood and Markov chain Monte Carlo (MCMC) sampling, while the second method is a likelihood-free approach using approximate Bayesian computation (ABC). Simulation-based calibration suggests that there are challenges with the empirical likelihood calculation used in the first calibration method in this context. These issues are alleviated in the ABC approach. Despite these challenges, we note that the first calibration method performs well in a synthetic data model validation test similar to those common in disease spread modeling literature. We conclude that stand-alone calibration verification using synthetic data may benefit epidemiological researchers in identifying model calibration challenges that may be difficult to identify with other commonly used model validation techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-T-289: MLC Fluence Sonogram Based Delivery Quality Assurance for Bilateral Breast Irradiation

Purpose: Performing DQA for Bilateral (B-L) breast tomotherapy is a challenging task due to the limitation of any commercially available detector array or film. Aim of this study is to perform DQA for B-L breast tomotherapy plan using MLC fluence sinogram. Methods: Treatment plan was generated on Tomotherapy system for B-L breast tumour. B-L breast targets were given 50.4 Gy prescribed over 28 fractions. Plan is generated with 6 MV photon beam & pitch was set to 0.3. As the width of the total target is 39 cm (left & right) length is 20 cm. DQA plan delivered without any phantom on the mega voltage computed tomography (MCVT) detector system. The pulses recorded by MVCT system were exported to the delivery analysis software (Tomotherapy Inc.) for reconstruction. The detector signals are reconstructed to a sonogram and converted to MLC fluence sonogram. The MLC fluence sinogram compared with the planned fluence sinogram. Also point dose measured with cheese phantom and ionization chamber to verify the absolute dose component Results: Planned fluence sinogram and reconstructed MLC fluence sinogram were compared using Gamma metric. MLC positional difference and intensity of the beamlet were used as parameters to evaluate gamma. 3 mm positional difference and 3% beamlet intensity difference were used set for gamma calculation. A total of 26784 non-zero beamlets were included in the analysis out of which 161 beamlets had gamma more than 1. The gamma passing rate found to be 99.4%. Point dose measurements were within 1.3% of the calculated dose. Conclusion: MLC fluence sinogram based delivery quality assurance performed for bilateral breast irradiation. This would be a suitable alternate for large volume targets like bilateral breast, Total body irradiation etc. However conventional method of DQA should be used to validate this method periodically.

60 APPLIED LIFE SCIENCES↗

Real-Time Highly Resolved Spatial-Temporal Vehicle Energy Consumption Estimation Using Machine Learning and Probe Data

Real-time highly resolved spatial-temporal vehicle energy consumption is a key missing dimension in transportation data. Most roadway link-level vehicle energy consumption data are estimated using average annual daily traffic measures derived from the Highway Performance Monitoring System; however, this method does not reflect day-to-day energy consumption fluctuations. As transportation planners and operators are becoming more environmentally attentive, they need accurate real-time link-level vehicle energy consumption data to assess energy and emissions; to incentivize energy-efficient routing; and to estimate energy impact caused by congestion, major events, and severe weather. This paper presents a computational workflow to automate the estimation of time-resolved vehicle energy consumption for each link in a road network of interest using vehicle probe speed and count data in conjunction with machine learning methods in real time. The real-time pipeline can deliver energy estimates within a couple seconds on query to its interface. The proposed method was evaluated on the transportation network of the metropolitan area of Chattanooga, Tennessee. The volume estimation results were validated with ground truth traffic volume data collected in the field. To demonstrate the effectiveness of the proposed method, the energy consumption pipeline was applied to real-world data to quantify road transportation-related energy reduction because of mitigation policies to slow the spread of COVID-19 and to measure energy loss resulting from congestion.

Severino, Joseph↗

Systematic study of the validity of the eikonal model including uncertainties

Nuclear reactions at intermediate beam energies are often interpreted using the eikonal model. In the analysis of complex reaction probes, where few-body reaction methods are needed, the eikonal method may be used as an efficient way for describing the fragment-target reaction process. In this work, we perform a systematic study to test the validity of the eikonal approximation for nucleon-nucleus reactions. We also quantify uncertainties due to the nucleon optical potential on reaction observables. We inspect the validity of the eikonal model and its semiclassical correction by comparing it to exact solutions (obtained from solving the optical-model equation with a finite-differences method) for a wide range of reactions. We also study the effect of relativistic corrections, both kinematic and dynamic, by effectively incorporating the relativistic effects at intermediate energies. The uncertainties from a Bayesian global optical potential (KDUQ) are propagated to the observables of interest. Our study includes neutron and proton reactions on 27 Al , 40 Ca , 90 Zr , and 208 Pb , for a wide range of energies 𝐸 lab = 0–400 MeV. We calculate neutron-total cross sections (elastic and reactions) as well as proton-absorption cross sections as a function of beam energy, using the eikonal model, the eikonal model with a semiclassical correction, and the exact solution. Here, we also compute angular distributions for the methods above. Our results show that for the proton-absorption cross section, the eikonal model can be used down to around 60 MeV and the semiclassical correction extends its use to 30 MeV. However, the validity of the eikonal model for the neutron-total cross section only goes down to ≈120 MeV, a range extended to ≈ 50 MeV when using the semiclassical correction. We find the semiclassical correction to the eikonal model to be less effective in describing the angular distributions. The 1⁢𝜎 uncertainty intervals on the observables we studied is less than 5% for most of the energies considered, but increases rapidly for higher energies, namely energies outside the range of KDUQ (𝐸 lab > 200MeV).

Cluster models↗

PET-Based Treatment Response Evaluation in Rectal Cancer: Prediction and Validation

Purpose: To develop a positron emission tomography (PET)-based response prediction model to differentiate pathological responders from nonresponders. The predictive strength of the model was validated in a second patient group, treated and imaged identical to the patients on which the predictive model was based. Methods and Materials: Fifty-one rectal cancer patients were prospectively included in this study. All patients underwent fluorodeoxyglucose (FDG) PET-computed tomography (CT) imaging both before the start of chemoradiotherapy (CRT) and after 2 weeks of treatment. Preoperative treatment with CRT was followed by a total mesorectal excision. From the resected specimen, the tumor regression grade (TRG) was scored according to the Mandard criteria. From one patient group (n = 30), the metabolic treatment response was correlated with the pathological treatment response, resulting in a receiver operating characteristic (ROC) curve based cutoff value for the reduction of maximum standardized uptake value (SUV{sub max}) within the tumor to differentiate pathological responders (TRG 1-2) from nonresponders (TRG 3-5). The applicability of the selected cutoff value for new patients was validated in a second patient group (n = 21). Results: When correlating the metabolic and pathological treatment response for the first patient group using ROC curve analysis (area under the curve = 0.98), a cutoff value of 48% SUV{sub max} reduction was selected to differentiate pathological responders from nonresponders (specificity of 100%, sensitivity of 64%). Applying this cutoff value to the second patient group resulted in a specificity and sensitivity of, respectively, 93% and 83%, with only one of the pathological nonresponders being false positively predicted as pathological responding. Conclusions: For rectal cancer, an accurate PET-based prediction of the pathological treatment response is feasible already after 2 weeks of CRT. The presented predictive model could be used to select patients to be considered for less invasive surgical interventions or even a 'wait and see' policy. Also, based on the predicted response, early modifications of the treatment protocol are possible, which might result in an improved clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sharp front tracking with geometric interface reconstruction

Here, this paper presents a novel sharp front-tracking method designed to address limitations in classical front-tracking approaches, specifically their reliance on smooth interpolation kernels and extended stencils for coupling the front and fluid mesh. In contrast, the proposed method employs exclusively sharp, localized interpolation and spreading kernels, restricting the coupling to the interfacial fluid cells–those containing the interface/front. This localized coupling is achieved by integrating a divergence-preserving velocity interpolation method with a piecewise parabolic interface calculation (PPIC) and a polyhedron intersection algorithm to compute the indicator function and local interface curvature. Surface tension is computed using the Continuum Surface Force (CSF) method, maintaining consistency with the sharp representation. Additionally, we propose an efficient local roughness smoothing implementation to account for surface mesh undulations, which is easily applicable to any triangulated surface mesh. Building on our previous work, the primary innovation of this study lies in the localization of the coupling for both the indicator function and surface tension calculations. By reducing the interface thickness on the fluid mesh to a single cell, as opposed to the 4–5 cell spans typical in classical methods, the proposed sharp front-tracking method achieves a highly localized and accurate representation of the interface. This sharper representation mitigates parasitic currents and improves force balancing, making it particularly suitable for scenarios where the interface plays a critical role, such as microfluidics, fluid-fluid interactions, and fluid-structure interactions. The proposed method is comprehensively validated and tested on canonical interfacial flow problems, including stationary and translating Laplace equilibria, oscillating droplets, and rising bubbles. The presented results demonstrate that the sharp front-tracking method significantly outperforms the classical approach in terms of accuracy, stability, and computational efficiency. Notably, parasitic currents are reduced by approximately two orders of magnitude and stable results are obtained for parameter ranges where classical front tracking fails to converge.

42 ENGINEERING↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategic Plan for Nuclear Energy -- Knowledge Base for Advanced Modeling and Simulation (NE-KAMS)

The Nuclear Energy Computational Fluid Dynamics Advanced Modeling and Simulation (NE-CAMS) system is being developed at the Idaho National Laboratory (INL) in collaboration with Bettis Laboratory, Sandia National Laboratory (SNL), Argonne National Laboratory (ANL), Utah State University (USU), and other interested parties with the objective of developing and implementing a comprehensive and readily accessible data and information management system for computational fluid dynamics (CFD) verification and validation (V&V) in support of nuclear energy systems design and safety analysis. The two key objectives of the NE-CAMS effort are to identify, collect, assess, store and maintain high resolution and high quality experimental data and related expert knowledge (metadata) for use in CFD V&V assessments specific to the nuclear energy field and to establish a working relationship with the U.S. Nuclear Regulatory Commission (NRC) to develop a CFD V&V database, including benchmark cases, that addresses and supports the associated NRC regulations and policies on the use of CFD analysis. In particular, the NE-CAMS system will support the Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, which aims to develop and deploy advanced modeling and simulation methods and computational tools for reliable numerical simulation of nuclear reactor systems for design and safety analysis. Primary NE-CAMS Elements There are four primary elements of the NE-CAMS knowledge base designed to support computer modeling and simulation in the nuclear energy arena as listed below. Element 1. The database will contain experimental data that can be used for CFD validation that is relevant to nuclear reactor and plant processes, particularly those important to the nuclear industry and the NRC. Element 2. Qualification standards for data evaluation and classification will be incorporated and applied such that validation data sets will result in well-defined, well-characterized data. Element 3. Standards will be established for the design and operation of experiments for the generation of new validation data sets that are to be submitted to NE-CAMS that addresses the completeness and characterization of the dataset. Element 4. Standards will be developed for performing verification and validation (V&V) to establish confidence levels in CFD analyses of nuclear reactor processes; such processes will be acceptable and recognized by both CFD experts and the NRC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

On computing stress in polymer systems involving multi-body potentials from molecular dynamics simulation

Hardy stress definition has been restricted to pair potentials and embedded-atom method potentials due to the basic assumptions in the derivation of a symmetric microscopic stress tensor. Force decomposition required in the Hardy stress expression becomes obscure for multi-body potentials. In this work, we demonstrate the invariance of the Hardy stress expression for a polymer system modeled with multi-body interatomic potentials including up to four atoms interaction, by applying central force decomposition of the atomic force. The balance of momentum has been demonstrated to be valid theoretically and tested under various numerical simulation conditions. The validity of momentum conservation justifies the extension of Hardy stress expression to multi-body potential systems. Computed Hardy stress has been observed to converge to the virial stress of the system with increasing spatial averaging volume. This work provides a feasible and reliable linkage between the atomistic and continuum scales for multi-body potential systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient particle control in systems with large density gradients

Simulations of large density gradients present a number of challenges for direct Monte Carlo methods, since they lead to too few particles in dilute regions and prohibitively many in the dense regions. Here, we propose a particle control methodology that gives the user more control of the number of particles per cell by introducing a variable weight for each particle. The proposed scheme is based on the stochastic weighted particle method, requires only small modifications to DSMC, and exactly conserves mass, momentum, and energy. In validation tests of systems with density ratios of order 102-104, we observe 101-102 times less variance in the dilute region compared to a DSMC solution with the same number of system particles, while introducing a moderate additional computational cost.

DSMC↗

On the Stability of a Linear System of Difference Equations with Random Parameters

We study the asymptotic behavior of solutions to a linear system of difference equation whose right-hand side at each time moment depends not only on the value at the previous moment, but also on a random parameter that takes its values in a given set. We obtain conditions of the Lyapunov stability and the asymptotic stability of the equilibrium position that are valid for all values of the random parameter or with probability 1.

97 MATHEMATICS AND COMPUTING↗