Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IB: a Monte Carlo Simulation Tool for Neutron Scattering Instrument Design under Parallel Virtual Machine

IB is a Monte Carlo simulation tool for aiding neutron scattering instrument designs. It is written in C++ and implemented under Parallel Virtual Machine. The program has a few basic components, or modules, that can be used to build a virtual neutron scattering instrument. More complex components, such as neutron guides and multichannel beam benders, can be constructed using the grouping technique unique to IB. Users can specify a collection of modules as a group. For example, a neutron guide can be constructed by grouping four neutron mirrors together that make up the four sides of the guide. IB s simulation engine ensures that neutrons entering a group will be properly operated upon by all members of the group. For simulations that require higher computer speed, the program can be run in parallel mode under the PVM architecture. Initially, the program was written for designing instruments on pulsed neutron sources, it has since been used to simulate reactor based instruments as well.

Monte Carlo Simulations↗

Identifying Opportunities at the Interface of Chemistry and Quantum Information Science (Final Technical Report)

This project convened a National Academies committee to identify opportunities and research priorities at the interface of chemistry and quantum information science (QIS). The work culminated in a consensus study report that (1) articulates three fundamental research areas to advance QIS (design and synthesis of molecular qubits; measurement and control of molecular quantum systems; and experimental and computational scaling of qubit design and function), and (2) underscores the importance of cross-disciplinary collaboration, access to facilities and instrumentation, FAIR-aligned data infrastructure, and workforce development initiatives to sustain U.S. leadership in QIS. The report and all other material associated with this project can be downloaded on the project webpage: https://www.nationalacademies.org/projects/DELS-BCST-21-01 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Detection Computational Benchmark Scenarios

Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 benchmark problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. The benchmarks were drawn primarily from existing or previous calculations with a preference for scenarios which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, the benchmarks were chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following benchmark identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Benchmark information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for compilation. This is a report describing the details of the selected Benchmarks and results from various transport codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse pileup statistics for energy discriminating photon counting x-ray detectors

Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analytically for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Divertor IR thermography on Alcator C-Mod

Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6 deg. toroidal sector has been given a 2 deg. toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GPU-FPX

GPU-FPX is a tool based on NVBit that detects and analyzes floating-point exceptions on NVIDIA GPUs through binary instrumentation. Its purpose is to detect and report the occurrences of floating-point exceptions during numerical computations, offering efficient location detections and exception flow. GPUFPX achieves exceptional performance, being 16x faster than comparable prior tools, such as BinFPE.

Laguna Peralta, Ignacio↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel Low-Cost Approach for Acquiring High Resolution High-Speed Data

The Oak Ridge National Laboratory (ORNL) has developed and tested a novel system architecture for acquiring high fidelity high-speed data. The approach uses a low-cost consumer grade audio recording device coupled with computing technology running open-source software. The main advantage of this approach is perchannel cost; an instrument grade data acquisition system typically costs between $800 to $2,000 per channel compared to less than $50 per channel for these consumer grade components. Three systems, each featuring four channels, have been deployed for acquiring data from geophones and the electrical supply system that supports the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at ORNL. Each channel samples at 96 kHz at 24-bit resolution. The deployed systems operate continuously 24/7 and produce about 4 terabytes of data per month per system. This paper provides a technical overview of this approach, its implementation, and some preliminary results from qualification testing. This work was conducted in support of the Multi-Informatics for Nuclear Operations Scenarios (MINOS).

Wetherington Jr, G↗

Collaborative Research: Enhancing Laser-Based Ion Sources with High Data Rate Techniques

This collaborative research project focuses on leveraging advanced machine learning techniques to analyze and optimize data from high-repetition-rate laser experiments. The main goal is to apply modern computing hardware, customized data acquisition firmware/software, and machine learning approaches to improve data analysis and experimental control. The project also explores how methodology can be developed on smaller-scale experimental setups and then translated to larger facilities within DOE's LaserNetUS network. With extensive data collection and modeling, the research aims to predict and optimize experimental parameters to enhance performance and efficiency.

47 OTHER INSTRUMENTATION↗

A lumped particle direct simulation Monte-Carlo method combined with the collisional-radiative model for simulations of non-equilibrium laser-induced plasma plumes

Collisional plasma plumes induced by laser irradiation of material targets exhibit large variations in local density as well as ionization and excitation states, making purely hydrodynamic or kinetic simulations inaccurate or infeasible. To address this challenge and capture non-equilibrium effects in laser-induced plasma plumes at arbitrary degrees of ionization, we develop a hybrid computational approach that combines the kinetic direct simulation Monte Carlo (DSMC) method with a collisional-radiative model (CRM). This ℓDSMC-CRM approach utilizes a lumped particle method to represent minor fractions of excited ions in particle-based simulations and a special coarse-graining technique for atomic spectra and photoionization rates, ensuring numerical convergence at reduced computational cost. The hybrid approach is applied to simulate spatially homogeneous relaxation as well as one- and two-dimensional expansions of plasma plumes induced by irradiation of a copper target by a nanosecond laser pulse in a vacuum or background gas. The comparison with an equilibrium model, where local Saha-Boltzmann equilibrium is enforced, shows that the non-equilibrium effects play a dominant role. The equilibrium model can fail to predict the flow structure and strongly underestimate the degree of absorption of laser radiation by the plume. The ℓDSMC-CRM approach is validated against experimental data demonstrating reasonable agreement with the experimental electron density and temperature, while the equilibrium model is found to dramatically underestimate electron density and temperature. The flexibility of the ℓDSMC-CRM approach allows for its seamless integration into existing DSMC frameworks, making it a valuable tool for high-fidelity plasma modeling in laser-material interactions, laser-based manufacturing, and beyond.

97 MATHEMATICS AND COMPUTING↗