Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiments for SINBAD: Evaluation of Oak Ridge Health Physics Research Reactor Operation Data for CAAS Benchmark Creation [Slides]

This report was a real information preservation and dissemination work with a lot of legacy content that was found and used. There was an abundance of uncertainty, discrepancy, and contradictory information. Yet, a detailed, functional SCALE model was built, and the benchmark created is useful for shielding and CAAs validation work. Sulfur fluence C/E ratios are large (2 to 5), so different benchmark metrics were studied. Neutron fluence, element 57 dose, and other dosimetry responses at 3 meters C/E ratios are below 1.5 for bare and steel configurations. Additional promising metrics as dose per unit fluence and steel shield attenuation were computed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation-Based Validation of An Open-Source, Scalable Framework for Building Energy Management in Small and Medium-Sized Commercial Buildings

Abstract: Small and medium-sized commercial buildings (SMCBs) represent 94% of U.S. commercial buildings but encounter substantial obstacles in adopting Building Energy Management (BEM) systems. Current approaches exhibit fundamental limitations: vendor-specific API platforms restrict interoperability through proprietary ecosystems; commercial automation software demands extensive technical expertise and licensing costs; open-source IoT solutions lack native support for building automation protocols and semantic models. This paper introduces a configuration-driven web interface framework addressing the gap between smart device advancements and accessible BEM software infrastructure for SMCBs. The framework leverages VOLTTRON middleware integrated with an automated converter that processes unified YAML configurations into heterogeneous system files, reducing required configuration artifacts from six separate files to a single unified specification. The system architecture enables vendor-agnostic operation through BACnet and Modbus protocols while supporting semantic building model integration via automated Brick Schema parsing. Configuration-driven interfaces automatically adapt to diverse HVAC types without custom development. Simulation-based validation using BOPTEST demonstrates automatic interface generation between fan coil and hydronic systems, with the automated converter successfully generating all platform-specific outputs from the single YAML input. The result demonstrates the framework's capability to streamline BEM system deployment through reduced configuration complexity. This work bridges simulation capabilities with operational deployment, demonstrating how virtual testbeds validate generalizable software frameworks for real-world building automation.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)↗

Constraint-Based Routing Models for the Transport of Radioactive Materials

The Department of Energy (DOE) has a historic programmatic interest in the safe and secure routing, tracking, and transportation risk analysis of radiological materials in the United States. In order to address these program goals, DOE has funded the development of several tools and related systems designed to provide insight to planners and other professionals handling radioactive materials shipments. These systems include the WebTRAGIS (Transportation Routing Analysis Geographic Information System) platform. WebTRAGIS is a browser-based routing application developed at Oak Ridge National Laboratory (ORNL) focused primarily on the safe transport of spent nuclear fuel from US nuclear reactors via railway, highway, or waterway. It is also used for the transport planning of low-level radiological waste to depositories such as the Waste Isolation Pilot Plant (WIPP) facility. One particular feature of WebTRAGIS is its coupling with high-resolution population data from ORNL s LandScan project. This allows users to obtain highly accurate population count and density information for use in route planning and risk analysis. To perform the routing and risk analysis WebTRAGIS incorporates a basic routing model methodology, with the additional application of various constraints designed to mimic US Department of Transportation (DOT), DOE, and Nuclear Regulatory Commission (NRC) regulations. Aside from the routing models available in WebTRAGIS, the system relies on detailed or specialized modal networks for the route solutions. These include a highly detailed network model of the US railroad system, the inland and coastal waterways, and a specialized highway network that focuses on the US interstate system and the designated hazardous materials and Highway Route Controlled Quantity (HRCQ) -designated roadways. The route constraints in WebTRAGIS rely upon a series of attributes assigned to the various components of the different modal networks. Routes are determined via a constrained shortest-path Dijkstra algorithm that has an assigned impedance factor. The route constraints modify the various impedance weights to bias or prefer particular network characteristics as desired by the user. Both the basic route model and the constrained impedance function calculations are determined by a series of network characteristics and shipment types. The study examines solutions under various constraints modeled by WebTRAGIS including possible routes from select shut-down reactor sites in the US to specific locations in the US. For purposes of illustration, the designated destinations are Oak Ridge National Laboratory in Tennessee and the Savannah River Site in South Carolina. To the degree that routes express sameness or variety under constraints serves to illustrate either a) the determinism of particular transport modes by either configuration or regulatory compliance, and/or b) the variety of constrained routes that are regulation compliant but may not be operationally feasible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Network resiliency through memory health monitoring and proactive management

A method for managing a network queue memory includes receiving sensor information about the network queue memory, predicting a memory failure in the network queue memory based on the sensor information, and outputting a notification through a plurality of nodes forming a network and using the network queue memory, the notification configuring communications between the nodes.

97 MATHEMATICS AND COMPUTING↗

Network resiliency through memory health monitoring and proactive management

A method for managing a network queue memory includes receiving sensor information about the network queue memory, predicting a memory failure in the network queue memory based on the sensor information, and outputting a notification through a plurality of nodes forming a network and using the network queue memory, the notification configuring communications between the nodes.

Andrade Costa, Carlos H.↗

Opdefender Network Monitoring And Control System

OpDefender is a new system designed to enhance the cyber security of control system networks. It accomplishes this by inspecting each network packet using a novel, patent-pending method that extends software defined networking into the application/ICS protocol layer. OpDefender consists of two key components: 1. Smart, “ICS-aware” network switches that analyze and filter network traffic in real time. 2. A network management human machine interface (HMI) that allows an operator to monitor and control network traffic in real time. The “ICS-aware” switches can serve as a drop-in replacement for typical network switches, or they can be used in conjunction with existing network switches. OpDefender is configured and controlled in real time via a custom-built, web-based HMI designed with the operator in mind.

Johnson, BriamE.↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CHP Integrated with Burners for Packaged Boilers (Final Report)

The objective of this project was to engineer, design, fabricate, and field demonstrate a Boiler Burner Energy System Technology (BBEST) that integrates a low-cost, clean burning, gas-fired simple-cycle (unrecuperated) 100 kWe (net) microturbine (SCMT) with a new ultra low-NOx gas-fired burner (ULNB) into one compact Combined Heat and Power (CHP) product that can be retrofit on new and existing industrial and commercial boilers in place of conventional burners. The Scope of Work for this project was segmented into two principal phases: (Phase I) Hardware development, assembly and pre-test and (Phase II) Field installation and demonstration testing. Phase I was divided into five technical tasks (Task 2 to 6). These tasks covered the engineering, design, fabrication, testing and optimization of each key component of the CHP system principally, ULNB, SCMT, assembly BBEST CHP package, and integrated controls. Phase I work culminated with the laboratory testing of the completed BBEST assembly prior to shipment for field installation and demonstration. Phase II consisted of two remaining technical tasks (Task 7 and 8), which focused on the installation, startup, and field verification tests at a pre-selected industrial plant to document performance and attainment of all project objectives. Technical direction and administration was under the management of CMCE, Inc. Altex Technologies Corporation lead the design, assembly and testing of the system. Field demonstration was supported by Leva Energy, the commercialization firm founded by executives at CMCE and Altex. Leva Energy has applied for patent protection on the BBEST process under the trade name of Power Burner and holds the license for the burner currently used in the product. The commercial term Power Burner is used throughout this report to refer to the BBEST technology proposed for this project. The project was co-funded by the California Energy Commission and the Southern California Gas Company (SCG), a division of Sempra Energy. These match funds were provided via concurrent contracts and investments available via CMCE, Altex, and Leva Energy The project attained all its objectives and is considered a success. CMCE secured the support of GI&E from Italy to supply 100 kW Turbec T-100 microturbines for the project. One was purchased by the project’s subcontractor, Altex, and a second spare was purchased by CMCE under this project. The microturbines were then modified to convert from their original recuperated design to a simple cycle configuration. Replacement low-NOx silo combustors were designed and bench tested in order to achieve compliance with the California Air Resources Board (CARB) 2007 emission limits for NOx and CO when in CHP operation. The converted microturbine was then mated with a low NOx burner provided by Altex via an integration section that allowed flow control and heat recovery to minimize combustion blower requirements; manage burner turndown; and recover waste heat. A new fully integrated control system was designed and developed that allowed one-touch system operation in all three available modes of operation: (1) CHP with both microturbine and burner firing for boiler heat input greater than 2 MMBtu/hr; (2) burner head only (BHO) when the microturbine is under service; and (3) microturbine only when boiler heat input requirements fall below 2 MMBtu/hr. This capability resulted in a burner turndown performance of nearly 10/1, a key advantage for this technology over conventional low NOx burners. Key components were then assembled into a cabinet with additional support systems for generator cooling and fuel supply. System checkout and performance tests were performed in the laboratory. The assembled system and its support equipment were then shipped and installed at a host facility where final performance tests were conducted following efforts to secure fabrication, air, and operating permits. The installed power burner is now in commercial operation and has achieved all the performance goals.

20 FOSSIL-FUELED POWER PLANTS↗

Sensitivity study of coupled chemical-CFD simulations for analyzing aluminum-clad spent nuclear fuel storage in sealed canisters

We report the United States Department of Energy (DOE) manages over 50 Metric Tons Heavy Metal (MTHM) of aluminum-clad spent nuclear fuel. One main source for DOE’s Aluminum-clad spent nuclear fuel (ASNF) inventory is the advanced test reactor (ATR) at the INL site, which makes this fuel of particular interest for storage scenarios. Road-ready and final disposition packaging configurations for the ATR fuel dictates storage within helium-backfilled, sealed DOE standard canisters. The conditions within these sealed canisters for extended (greater than50 year dry) storage is of interest. To further this goal, a three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model is developed of the sealed DOE standard canisters. This 3D CFD model is one-way coupled with bulk gas radiolysis reactions considering sealed canisters with inert gas and possible trace amounts of air and water vapor. This study looks at the evolution of the thermal history of the canisters over a 50 year time period with a coupling to the chemical reactions occurring from radiolytic breakdown of residual water. A sensitivity study is then carried out over the parameters of the model including the fuel decay heat, residual water content, sealed pressure, canister external temperature, and canister emissivity. In pure helium, hydrogen generation rates are low, under 10 ppm, but hydrogen generation rates are affected greatly by the presence of even 1% residual air, increasing by 50-plus-fold, and nitric acid generation with residual air also occurs ranging from 500 to 4000 ppm after 50 years. The fuel decay heat and the residual water content show the most importance in the generation of hydrogen gas in pure air, and for nitric acid with a residual air condition. External temperature, canister emissivity and sealed pressure all show minor sensitivity effects to the generation of potentially harmful species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ORCHA: A performance portability system for extreme heterogeneity

Heterogeneity is the prevalent trend in the rapidly evolving high-performance computing (HPC) landscape in both hardware and application software. The diversity in hardware platforms, currently comprising various accelerators and a future possibility of specializable chiplets, poses a significant challenge for scientific software developers aiming to harness optimal performance across different computing platforms while maintaining the quality of solutions when their applications are simultaneously growing more complex. Code synthesis and code generation can provide mechanisms to mitigate this challenge. We have developed a divide and conquer approach where different aspects of performance are handled by different stand-alone tools that are interfaced with the application through generated code. This portability system, ORCHA, enables users to configure and orchestrate their computations among available resources on a platform by specifying a high-level recipe, thereby permitting a many-to-many paradigm where each recipe results in a different variant of the application. The core design goal is to let users decide the application’s hardware mapping and orchestration by editing only the high-level recipe—without modifying the maintained source code or binding the application to a particular runtime system. Tools in ORCHA distribution are: CG-Kit for translating the recipe into an execution graph; Milhoja to execute the graph by orchestrating data and task movement among hardware resources; and Macroprocessor that enables users to define their own code-shorthand for higher composability and easier management of code variants. Additionally, the design of ORCHA permits tools to work in a plug-and-play mode where the application can build and run without CG-Kit and Milhoja, and either tool can be swapped out for other tools with similar capabilities by modifying the code generation portion of ORCHA. In this paper, we describe the design of ORCHA and the role that code-generation plays in isolating applications from tools. We demonstrate the breadth of configurations ORCHA enables with a case study in which an application configuration is realized on three distinct hardware mappings—a GPU-centric, a CPU/GPU balanced, and a CPU/GPU concurrent layouts by using different recipes.

Lee, Youngjun↗

Cyber-Physical Security Assessment (CyPSA) Toolset

CyPSA seeks to organize and gain insight into the diverse sets of data that a critical infrastructure provider must manage. Specifically CyPSA inventories, manages, and analyzes assets and relations among those assets. A variety of interfaces are provided. CyPSA inventories assets (both cyber and physical). This may include the cataloging of assets through a common interface. Data sources used to generate a catalogue of assets include PowerWorld, NPView, NMap Scans, and device configurations. Depending upon the role of the person using the tool the types of assets accessed as well as the data sources through which asset information is accessed may vary. CyPSA allows practitioners to catalogue relations among assets and these may either be manually or programmatically generated. For example, some common relations among assets include the following: Topological Network Data: Which devices and assets are connected and how? Data sources for this kind of information include NMap scans, NPView topologies (via Firewall rule analysis). Security Metrics Outputs: The output of various security metrics such as overall exposure. Configure Assets:CyPSA may eventually include the ability to configure assets including relays and switches. For example, a system administrator would be able to configure and alter the state of a relay via the CyPSA interface. Annotate Assets: CyPSA also allows practitioners to manually and programmatically annotate assets. Sources of information with which to annotate assets include provenance metadata regarding the data source from which the asset was loaded, vulnerability information from vulnerability databases, configuration information, and the output of an analysis in general.

Garcia, Luis↗

A parallel workflow implementation for PEST version 13.6 in high-performance computing for WRF-Hydro version 5.0: a case study over the midwestern United States

The Weather Research and Forecasting Hydrological (WRF-Hydro) system is a state-of-the-art numerical model that models the entire hydrological cycle based on physical principles. As with other hydrological models, WRF-Hydro parameterizes many physical processes. Hence, WRF-Hydro needs to be calibrated to optimize its output with respect to observations for the application region. When applied to a relatively large domain, both WRF-Hydro simulations and calibrations require intensive computing resources and are best performed on multimode, multicore high-performance computing (HPC) systems. Typically, each physics-based model requires a calibration process that works specifically with that model and is not transferrable to a different process or model. The parameter estimation tool (PEST) is a flexible and generic calibration tool that can be used in principle to calibrate any of these models. In its existing configuration, however, PEST is not designed to work on the current generation of massively parallel HPC clusters. To address this issue, we ported the parallel PEST to HPCs and adapted it to work with WRF-Hydro. The porting involved writing scripts to modify the workflow for different workload managers and job schedulers, as well as to connect the parallel PEST to WRF-Hydro. To test the operational feasibility and the computational benefits of this first-of-its-kind HPC-enabled parallel PEST, we developed a case study using a flood in the midwestern United States in 2013. Results on a problem involving the calibration of 22 parameters show that on the same computing resources used for parallel WRF-Hydro, the HPC-enabled parallel PEST can speed up the calibration process by a factor of up to 15 compared with commonly used PEST in sequential mode. The speedup factor is expected to be greater with a larger calibration problem (e.g., more parameters to be calibrated or a larger size of study area).

54 ENVIRONMENTAL SCIENCES↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Autonomous MCP Bridge to Rucio: Enhancing Data Management Accessibility for High Energy Physics

The Rucio Data Management System [1] is an important tool used by High Energy Physics experiments, including those at Fermi National Accelerator Laboratory, to store and manage exabyte-scale scientific datasets. Despite its central role in coordinating data across globally distributed storage sites, Rucio's command line interface (CLI) presents a steep learning curve, and makes it difficult for scientists to navigate through. To solve this issue, a containerized Model Context Protocol (MCP) [2] server was built that connects Large Language Models directly to Rucio, allowing AI agents to handle data tasks by using simple, natural language rather than memorized terminal commands. The core engineering focus of this project was moving the server away from slow terminal commands that require text parsing and replacing them with a native Python Client API toolset and a planned REST API framework. Moving to the Python API handles data operations directly in memory, which helps clear up formatting errors, provides the AI with clean, structured JSON data and speeds up tool execution. To prove that the system actually works, a benchmarking pipeline was also built with various questions to test the AI across four different model configurations. The questions included finding data scopes, tracking down specific datasets, and checking replication rules. Through benchmarking, early runs showed that with raw terminal text, the model would get confused and stuck, whereas switching to the Python API to feed the AI clean, structured data yielded massive improvement. By creating an intelligent and autonomous bridge to a storage network, this project shows how AI can be implemented in scientific data management, which ultimately helps scientists at Fermilab spend less time sorting through data and more time focusing on their experiments and analysis.

Akella, Kashyap [William Rainey Harper Coll.]↗

Refreshing Waste Tracking Software for the 2020's - 20059

The Waste Compliance and Tracking System (WCATS) is a software application designed to manage waste operations from cradle to grave. The system provides the support needed for characterization, generation, processing, and shipment of all waste generated or stored at Los Alamos National Laboratory (LANL). Waste is tracked with task records for containers in real-time via both desktop and mobile device applications. The software allows application administrators to configure sites with appropriate limits for Pu-239 equivalent Curies (PE-Ci), fissile gram equivalents (FGEs), volume limits, as well as custom limits for site-specific technical safety requirements (TSRs). WCATS was developed based on a need at Los Alamos National Laboratory for a modern, customizable waste tracking system that could support many different waste types. The application is built using Oracle{sup R} database and Oracle{sup R} ADF Swing application framework. The technologies and software frameworks selected for the system were finalized in 2006. Although Oracle{sup R} Database has proven to be robust, the user interface and application framework interface with the database have been deprecated and need to be replaced. The technologies selected for modernization follow the open-source model, which allows the WCATS team to more easily recruit developers, improve the speed of development, and ease the deployment and adoption of the system. The tools that support the re-engineering effort are Vue.js{sup R}, a JavaScript{sup R} framework, and Spring Boot{sup R}, an API (application programming interface) development tool written in Java{sup R}. An API allows for simplified communication from the database to the user interface of the application. In addition, legacy Crystal Reports{sup R} will be replaced with reports developed with the open source Pentaho{sup TM}f Report Designer community edition. Because the application uses HTML and JavaScript{sup R}, it builds upon tools that have been used for many years in web development. These tools have large community support and their proven track record will ensure that enhancements to WCATS can continue for years to come. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Carbon Tetrachloride Flow and Transport in the Subsurface of the 200 West Disposal Sites: Large-Scale Model Configuration and Prediction of Future Carbon Tetrachloride Distribution Beneath the 216-Z-9 Disposal Site

Three-dimensional simulations considered migration of dense, nonaqueous phase liquid (DNAPL) consisting of CT and co disposed organics in the subsurface as a function of the properties and distribution of subsurface sediments and of the properties and disposal history of the waste. Simulations of CT migration were conducted using the Water-Oil-Air mode of Subsurface Transport Over Multiple Phases (STOMP) simulator. A large-scale model was configured to model CT and waste water discharge from the major CT and waste-water disposal sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗