Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Liquefaction of Forest Biomass to "Drop-in" Hydrocarbon Biofuels

The overall goal of the project was to demonstrate solvent liquefaction as a viable path to stable intermediates for subsequent upgrading to fuel blendstocks. Iowa State University (ISU) utilized technology developed by Chevron to produce “green crude” via continuous biomass liquefaction to bio-oil without catalyst or reducing gas, then upgraded the crude to drop-in hydrocarbon liquid transportation fuels. Original benchmarks for the project included conversion of biomass to bio-oil at a yield of 50% or more, produce bio-oil with oxygen content below 20 wt%, and recycle a portion of the bio-oil product for use as solvent, displacing initial hydrocarbon solvent. Initial testing and technology development was completed by Chevron using a custom Small Continuous Liquefaction Unit (SCLU) operated in “once-through” mode. In this system, liquid product and solid residual/char was collected together and required both off-line solids removal and product separation. This unit was disassembled and major components incorporated into a redesigned solvent liquefaction system at ISU capable of processing biomass at rates up to 1 kg/h. Online, continuous solids separation and bio-oil recovery/separation systems were successfully implemented. Online solids removal using an acetone injection to aid in separation achieved over 99% solids removal efficiency, and acetone recovery of greater than 97% was achieved. The gas stripping system developed for the separation of medium wood oil (MWO) for the recycle stream from the heavy wood oil (HWO) product stream was also successful in recovering approximately 93 wt% of the initial solvent from the biomass-derived products. Due to the generation of fine particulate and the high molecular weight of the HWO which both negatively affect the ability to separate the product oil, solvent recycle was not fully implemented in the system. The biomass used in this project is loblolly pine forest residue. The solvent was a blend of two hydrocarbon liquids. The majority of the solvent was comprised of commercially available naphthalene-depleted heavy aromatic solvent. The hydrogen donor solvent was a proprietary cut of light cycle oil (LCO) that was hydrotreated. As much as 25 wt% of the solvent mixture was comprised of the hydrotreated LCO. Higher blend ratios were limited by the economics of providing hydrogen to the process in this manner. Two cases were evaluated for technical feasibility on the SCLU. These are 1. Simulated phenolic solvent recycle and 2. Hydrocarbon-rich solvent processing. The simulated phenolic solvent recycle case was based on an idealistic solvent mixture where only 5% makeup or hydrogen donor solvent entered the system. The resulting solvent mixture at steady state was estimated to be 75 wt% depleted hydrogen donor, 20 wt% biomass derived phenolic monomers, and 5 wt% HLCO. This case resulted in the highest bio-oil organic yield observed in the project of 66.7 wt% on a solvent-less, dry biomass basis and relatively low oxygen content of 12%. Additionally, these conditions deconstructed the biomass so well, that extremely fine particulate was generated such that 5 micron barrier filters were unable to remove the material. Offline addition of acetone, centrifugation and acetone removal were required in order to remove the particulate prior to fractionation with the stripping column. The resulting HWO had a high molecular weight and was therefore very viscous in nature, remaining solid at room temperature. Additionally, the column was unable to sustainably strip enough MWO to close the recycle loop balance while maintaining flowability of product oil exiting the column. It was determined that additional HLCO would be required at the front of the process to decrease product viscosity both by dilution and additional hydrogen transfer into the HWO product oil. The hydrocarbon rich mixture was the preferred mixture for a majority of the project and featured a 25% donor or HLCO content and 75% depleted hydrogen donor mix. A series of three tests were conducted using this mixture and serve as the basis for a paper detailing the system. While the online acetone injection system for high pressure solids removal was demonstrated early on using this mixture, difficulty controlling process flows led to the use of an atmospheric stirred tank filtration system. At these high donor solvent levels, the product stream easily partitioned with sufficient MWO to close the recycle loop balance. Additionally, this mixture produced HWO product oil at just over 55% yield, <5% oxygen content, and a reasonable viscosity at room temperature. A 56 hour campaign was conducted with the ISU pilot to produce a large enough batch of HWO product oil to conduct upgrading experiments at Chevron’s Richmond, CA facility. Benchtop hydrotreating units were used to conduct long-duration hydrogenation/hydrogenolysis reactions in order to provide yield data and help validate assumptions made in the TEA model. Resulting products featured an oxygen content of <1%, near the detectability limit. Hydrocracking simulations were also performed, and a distribution of heavy wood oil to refinery products was determined. These distributions are based on a database of commercial and pilot plant operation used by Chevron to estimate product yield from novel inputs based on the input physical and chemical characteristics. While multi-week benchtop hydrotreating tests were successfully conducted without fouling, analysis and testing of the heavy wood oil suggest it may be better suited for hydrocracking. Metals content in the heavy wood oil would likely create catalyst fouling over time and reduce lifetime of hydrotreating catalysts. Yields and product partitioning were also more favorable from hydrocracking compared to those from hydrotreating.

09 BIOMASS FUELS↗

Tall Tower Vertical Profiles and Diurnal Trends of Ammonia in the Colorado Front Range: Tall Tower Vertical Profiles of Ammonia

Ammonia (NH 3 ) mixing ratios were measured between the surface and 280 m aboveground level from a moveable carriage at the Boulder Atmospheric Observatory tower in summer 2014 as part of the Front Range Air Pollution and Photochemistry Éxperiment. The campaign median mixing ratio was 3.3 ppb, ranging from below detection limits to 192 ppb. Median vertical profiles show an overall increase in NH 3 mixing ratios toward the surface of 6.7 ppb (89%) during the day and 3.9 ppb (141%) at night. In contrast to the overall increasing trend, some individual profiles show decreasing NH 3 in the lowest 10 m. This suggests that the local surface is capable of acting as either a source or a sink, depending on the relative amounts of NH 3 at the surface, and in advected air parcels. We further use this data set to investigate the variation in diurnal patterns of NH 3 as a function of height above the surface. At higher altitudes (100 ± 5 and 280 ± 5 m), NH 3 mixing ratios reach a gradual maximum during the day between 9:00 and 16:00 local time, likely driven by changes in source region. At lower altitudes (10 ± 5 m), the daytime maximum begins earlier at about 7:00 local time, followed by a sharper increase at 9:00 local time. At this height we also observe a peak in NH3 mixing ratios during the night, likely driven by the trapping of emitted NH 3 within the shallower nocturnal boundary layer.

54 ENVIRONMENTAL SCIENCES↗

Near-Zero Power MOF-Based Sensors for NO 2 Detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The ability to directly electrically detect trace (0.5–5 ppm) NO 2 by a metal–organic framework (MOF)-74-based sensor at relatively low temperatures (50 °C) is demonstrated via changes in electrical properties of M-MOF-74, M = Co, Mg, Ni. The magnitude of the change is ordered Ni > Co > Mg and explained by each variant's NO 2 adsorption capacity and specific chemical interaction. Ni-MOF-74 provides the highest sensitivity to NO 2 ; a 725× decrease in resistance at 5 ppm NO2 and detection limit <0.5 ppm, levels relevant for industry and public health. Furthermore, the Ni-MOF-74-based sensor is selective to NO 2 over N 2 , SO 2 , and air. Linking this fundamental research with future technologies, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, with the active material drawing <15 pW for a macroscale device 35 mm 2 with 0.8 mg MOF-74. Finally, this represents a 10 4 –10 6 × decrease in power consumption compared to other MOF sensors and demonstrates the potential for MOFs as active components for long-lived, near-zero power chemical sensors in smart industrial systems and the internet of things.

47 OTHER INSTRUMENTATION↗

Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring

Flexible pressure sensors have many potential applications in wearable electronics, robotics, health monitoring, and more. In particular, liquid-metal-based sensors are especially promising as they can undergo strains of over 200% without failure. However, current liquid-metal-based strain sensors are incapable of resolving small pressure changes in the few kPa range, making them unsuitable for applications such as heart-rate monitoring, which require a much lower pressure detection resolution. In this paper, a microfluidic tactile diaphragm pressure sensor based on embedded Galinstan microchannels (70 µm width × 70 µm height) capable of resolving sub-50 Pa changes in pressure with sub-100 Pa detection limits and a response time of 90 ms is demonstrated. An embedded equivalent Wheatstone bridge circuit makes the most of tangential and radial strain fields, leading to high sensitivities of a 0.0835 kPa -1 change in output voltage. The Wheatstone bridge also provides temperature self-compensation, allowing for operation in the range of 20–50 °C. Finally, as examples of potential applications, a polydimethylsiloxane (PDMS) wristband with an embedded microfluidic diaphragm pressure sensor capable of real-time pulse monitoring and a PDMS glove with multiple embedded sensors to provide comprehensive tactile feedback of a human hand when touching or holding objects are demonstrated.

47 OTHER INSTRUMENTATION↗

Stepwise Assembly of Turn‐on Fluorescence Sensors in Multicomponent Metal–Organic Frameworks for in Vitro Cyanide Detection

Abstract The controlled synthesis of multicomponent metal–organic frameworks (MOFs) allows for the precise placement of multiple cooperative functional groups within a framework, leading to emergent synergistic effects. Herein, we demonstrate that turn‐on fluorescence sensors can be assembled by combining a fluorophore and a recognition moiety within a complex cavity of a multicomponent MOF. An anthracene‐based fluorescent linker and a hemicyanine‐containing CN − ‐responsive linker were sequentially installed into the lattice of PCN‐700. The selective binding of CN − to hemicyanine inhibited the energy transfer between the two moieties, resulting in a fluorescence turn‐on effect. Taking advantage of the high tunability of the MOF platform, the ratio between anthracene and the hemicyanine moiety could be fine‐tuned in order to maximize the sensitivity of the overall framework. The optimized MOF‐sensor had a CN − ‐detection limit of 0.05 μ m , which is much lower than traditional CN − fluorescent sensors (about 0.2 μ m ).

Li, Jialuo↗

Matrix Extension Validation of AOCS Ce 2c‐11 for Omega‐3 Polyunsaturated Fatty Acids in Conventional Foods and Dietary Supplements Containing Added Marine Oil

Abstract Marine oils are commonly added to conventional foods and dietary supplements to enhance their contents of omega‐3 polyunsaturated fatty acids (PUFA), including eicosapentaenoic acid (EPA; 20:5n‐3) and docosahexaenoic acid (DHA; 22:6n‐3), which have been associated with numerous potential health benefits. This study compared American Oil Chemists’ Society (AOCS) Official Methods Ce 2b‐11 and Ce 2c‐11 for determining EPA and DHA in foods and dietary supplements and found that AOCS Ce 2c‐11 produces significantly higher analyzed values, which could be attributed to a more comprehensive breakdown of the sample matrix and derivatization of fatty acids. Our subsequent food matrix extension validation of AOCS Ce 2c‐11 demonstrated that the method produces true, accurate, sensitive, and precise determinations of EPA, DHA, and total omega‐3 PUFA in foods and dietary supplements containing added marine oil, including those formulated with emulsified and microencapsulated oils. The method detection limits for EPA and DHA were 0.012 ± 0.002 and 0.011 ± 0.003 mg g −1 , respectively (means ± SD). The analyzed contents of EPA (1.26–386 mg serving −1 ), DHA (1.37–563 mg serving −1 ), and total omega‐3 PUFA (2.69–1270 mg serving −1 ) were reported for 27 conventional food and dietary supplement products. Eighteen products declared contents of DHA, EPA + DHA, or total omega‐3 PUFA on product labels, and the analyzed contents of those fatty acids varied from 95 to 162% of label declarations for all but two of the products.

Li, Ziyi↗

A Metal-Organic Framework Containing Unusual Eight-Connected Zr–-Oxo Secondary Building Units and Orthogonal Carboxylic Acids for Ultra-sensitive Metal Detection

Two metal-organic frameworks (MOFs) with Zr-oxo secondary building units (SBUs) were prepared by using p,p'-terphenyldicarboxylate (TPDC) bridging ligands pre-functionalized with orthogonal succinic acid (MOF-1) and maleic acid groups (MOF-2). Single-crystal X-ray structure analysis of MOF-1 provides the first direct evidence for eight-connected SBUs in UiO-type MOFs. In contrast, MOF-2 contains twelve-connected SBUs as seen in the traditional UiO MOF topology. These structural assignments were confirmed by extended X-ray absorption fine structure (EXAFS) analysis. The highly porous MOF-1 is an excellent fluorescence sensor for metal ions with the detection limit of <0.5 ppb for Mn 2+ and three to four orders of magnitude greater sensitivity for metal ions than previously reported luminescent MOFs.

Carboni, Michaël↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

Assessing a Spectroelectrochemical Sensor's Performance for Detecting [Ru(bpy)3]2+ in Natural and Treated Water

A spectroelectrochemical sensor that combines three modes of selectivity in a single device was evaluated in natural and treated water samples using tris-(2,2’-bipyridyl) ruthenium(II) dichloride hexahydrate, [Ru(bpy)3]2+, as a model analyte. The sensor was an optically transparent indium tin oxide (ITO) electrode coated with a thin film of partially sulfonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SSEBS). As the potential of the ITO electrode was cycled from +0.7 to +1.3 V, the analyte changed from the colored [Ru(bpy)3]2+ complex to colorless [Ru(bpy)3]3+ complex and the change in absorbance at 450 nm was used as the optical signal for quantification. Calibration curves were obtained for [Ru(bpy)3]2+ in natural well water, river water and treated tap water with detection limits of 108, 139 and 264 nM, respectively. A standard addition method was developed to determine an *unknown* spike addition concentration of [Ru(bpy)3]2+ in well water. The spectroelectrochemical sensor determined the concentration of [Ru(bpy)3]2+ spiked into a sample of Hanford well water to be 0.39*0.03 mM versus the actual concentration of 0.40 mM.

ITO electrode↗

Polyoxometalate-Graphene Nanocomposite Modified Electrode for Electrocatalytic Detection of Ascorbic Acid

Phosphomolybdate functionalized graphene nanocomposite (PMo 12 -GS) has been successfully formed on a glassy carbon electrode (GCE) for the detection of ascorbic acid (AA). The obtained PMo 12 -GS modified GCE, was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR) spectroscopy and compared with GCE, GS modified GCE, and PMo 12 modified GCE. It shows an increased current and a decrease in over-potential of ~210 mV. The amperometric signals are linearly proportional to the AA concentration in a wide concentration range from 1×10 -6 M to 8×10 -3 M, with a detection limit of 0.5×10 -6 M. Finally, the PMo 12 -GS modified electrode was employed for the determination of the AA level in vitamin C tablets, with recoveries between 96.3 and 100.8 %.

Ascorbic Acid↗

Electroless Deposition of Silver Nanoparticles on Graphene Oxide Surface and Its Applications for the Detection of Hydrogen Peroxide

We developed a new process to decorate graphene oxide (GO) with silver nanoparticles through electroless deposition technique, which was performed by treating GO with Sn 2+ first and then with Ag + . Furthermore, silver nanoparticles-GO (AgNPs-GO) nanocomposites were prepared by this technique. The process was monitored using UV-vis spectroscopy, Raman spectroscopy and transmission electron microscopy (TEM). The electrochemical behaviour of AgNPs-GO modified glassy carbon electrode was investigated by cyclic voltammetry. The potential application of this technique for hydrogen peroxide detection was tested with a range from 10 µM to 20 mM with a detection limit of 0.5 µM.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Statistical interpretation of the Amerithrax “morph” assay results

In the Amerithrax investigation PCR–based “morph assays” were used to link the anthrax letters with the RMR–1029 flask at USAMRIID. Quantitative data reported for several of these assays are not consistent with Poisson sampling statistics, but instead exhibit “Taylor's Law” behavior where the variance greatly exceeds the mean. A plausible statistical model for this behavior can explain the large number of observed negative and “inconclusive” findings, and implies a high likelihood that a repository sample could contain a “morph” mutant at concentrations well above the nominal detection limit but nonetheless give a negative or inconclusive test result. A Bayesian framework relates the assay results to the probability that a sample actually contains all four morph mutants, even though it tested negative for at least one. The analysis implies that the observed false negative rate actually does not significantly weaken the conclusion that the morph assays correctly excluded all but the stocks derived from RMR–1029 as possible sources of the letter powders, at least when the test results were unambiguous. In conclusion, these findings expand upon and resolve some of the issues cited in recent reviews, and indicate the importance of developing a rigorous statistical framework for interpreting “morph” assay data.

59 BASIC BIOLOGICAL SCIENCES↗

The Effect of Membrane Casting Irregularities on Initial Fuel Cell Performance

Membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) may possess as-manufactured non-uniformities in any of its constituent components. This article studies casting irregularities located within the PEM to understand their potential impact on MEA initial performance. Membrane material was cast on a lab-scale polymer casting line operating either within or at the boundaries of the process window. The resulting membrane material was either pristine in the former case, or, in the latter case, contained air bubbles, cracks, and other irregularities, ranging in size from about 0.6 to 3 mm. Spatial polarization experiments were conducted using a 121-channel segmented fuel cell system, and thermal imaging was performed subsequently to map hydrogen crossover to spatial performance. While total-cell polarization data was minimally impacted by the irregularities, the spatial diagnostics showed local performance impacts that, in operation over time, could cause degradation in performance or earlier failure of the MEA. Such impacts could lead to these irregularities being classified as defects, i.e., manufacturing variations that should be identified and not included in a fuel cell stack. Classification of irregularities as defects will ultimately assist the industry by contributing to the development of threshold detection limits for in-line quality control diagnostics.

30 DIRECT ENERGY CONVERSION↗

Macrophysical Properties of Tropical Cirrus Clouds from the CALIPSO Satellite and from Ground-based Micropulse and Raman Lidars

Lidar observations of cirrus cloud macrophysical properties over the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) program Darwin, Australia site are compared from the Cloud-Aerosol Lidar and In- frared Pathfinder Satellite Observation (CALIPSO) satellite, the ground-based ARM micropulse lidar (MPL), and the ARM Raman lidar (RL). Comparisons are made using the subset of profiles where the lidar beam is not fully attenuated. Daytime measurements using the RL are shown to be relatively unaffected by the solar background and are therefore suited for checking the validity of diurnal cycles. RL and CALIPSO cloud fraction profiles show good agreement while the MPL detects significantly less cirrus, particularly during the daytime. Both MPL and CALIPSO observations show that cirrus clouds occur less frequently during the day than at night at all altitudes. In contrast, the RL diurnal cy- cle is significantly different than zero only below about 11 km; where it is the opposite sign (i.e. more clouds during the daytime). For cirrus geomet- rical thickness, the MPL and CALIPSO observations agree well and both datasets have signficantly thinner clouds during the daytime than the RL. From the examination of hourly MPL and RL cirrus cloud thickness and through the application of daytime detection limits to all CALIPSO data we find that the decreased MPL and CALIPSO cloud thickness during the daytime is very likely a result of increased daytime noise. This study highlights the vast im- provement the RL provides (compared to the MPL) in the ARM program's ability to observe tropical cirrus clouds as well as a valuable ground-based lidar dataset for the validation of CALIPSO observations and to help im- prove our understanding of tropical cirrus clouds.

Cirrus Clouds↗

Broadband surface-enhanced coherent anti-Stokes Raman spectroscopy with high spectral resolution

Both the surface-enhanced Raman spectroscopy (SERS) and coherent anti-Stokes Raman spectroscopy (CARS) are widely used methods in the bio-sensing field for improving the intensity of Raman scattering process. By combining the mechanisms of CARS (coherence and nonlinear process) and SERS (plasmon resonance), a multiplicative enhancement can be achieved through surface-enhanced CARS (SECARS). Besides sensitivity, high specificity with wide spectral bandwidth is also preferred for bio-sensing techniques but not well developed in SECARS setups reported in the literature. A broadband SECARS setup with high sensitivity and high spectral resolution is presented. Rhodamine 6G dye molecules and several biomolecules are used as the model system to benchmark the functionality of the SECARS system in terms of its sensitivity, the lowest detectable concentration, and the spectral resolution. Our setup rendered single-molecule sensitivity with spectral resolution of <35 cm -1 . More than 10 2 times stronger signal-to-noise ratio compared with that of SERS is observed with the detection limit being 10 -9 m. Different from the SECARS systems in the literature, our setup employs a unique graphene-Au pyramids hybrid platform. The graphene in this structure provides additional SERS enhancement and a bio-compatible surface. Finally, this powerful technique could be instrumental in furthering the understanding of various chemical and biological processes.

42 ENGINEERING↗

Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemica lionization

An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗