Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Physics with near detectors at a neutrino factory

We discuss the impact of near detectors at a neutrino factory both on standard oscillation and nonstandard interaction measurements. Our systematics treatment includes cross section errors, flux errors, and background uncertainties, and our near detector fluxes include the geometry of the neutrino source and the detector. Instead of a specific detector concept, we introduce qualitatively different classes of near detectors with different characteristics, such as near detectors catching the whole neutrino flux (near detector limit) versus near detectors observing a spectrum similar to that of the far detector (far detector limit). We include the low energy neutrino factory in the discussion. We illustrate for which measurements near detectors are required, discuss how many are needed, and what the role of the flux monitoring is. For instance, we demonstrate that near detectors are mandatory for the leading atmospheric parameter measurements if the neutrino factory has only one baseline, whereas systematical errors partially cancel if the neutrino factory complex includes the magic baseline. Finally, near detectors with {nu}{sub {tau}} detection are shown to be useful for nonstandard interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

Purpose: To determine detector-specific output correction factors,k{sub Q} {sub c{sub l{sub i{sub n}}}} {sub ,Q} {sub m{sub s{sub r}}} {sup f{sub {sup {sub c}{sub l}{sub i}{sub n}{sub {sup ,f{sub {sup {sub m}{sub s}{sub r}{sub ,}}}}}}}} in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers. Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179–5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm{sup 2} and 10 × 10 cm{sup 2} from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm{sup 2}. Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ±1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates. Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-390: Characterization of the PTW Synthetic Diamond Detector for Radiation Therapy Measurements

Purpose: To investigate the dosimetric properties of new commercially available synthetic single crystal diamond detector under irradiation with therapeutic photon beams from linear accelerators. Methods: A single crystal diamond detector was tested using 6MV photon beam. The detector performance was evaluated for reproducibility, linearity with dose, dose rate dependence, angular dependence, collection efficiency, and measurement of output factors. Lateral field profiles, and percentage depth dose profiles were measured and compared against commercially available detectors. Results: Reproducibility of the detector measurement has a standard deviation of 0.1%. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.03% in the dose range from 0.1 to 5Gy. In addition, the detector response is dose rate independent, with deviations below 0.1% in the investigated dose rate range from 1 to 10Gy per min. Charge collection efficiency deviations were within 0.07% from 1 to 10Gy. No angular dependence along the radial direction while up to 1.3% angular dependence was observed in the axial direction. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical photon beam dosimetry. The agreement with reference dosimeters show that the detector is suitable for measurements for large fields as well as small fields as the ones used for stereotactic radiotherapy.

60 APPLIED LIFE SCIENCES↗

Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Search for Low-Mass Dark Matter with the Cryogenic Dark Matter Search and the Development of Highly Multiplexed Phonon-Mediated Particle Detectors

A wide variety of astrophysical observations indicate that approximately 85% of the matter in the universe is nonbaryonic and nonluminous. Understanding the nature of this "dark matter" is one of the most important outstanding questions in cosmology. Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter since they would be thermally produced in the early universe in the correct abundance to account for the observed relic density of dark matter. If WIMPs account for the dark matter, then rare interactions from relic WIMPs should be observable in terrestrial detectors. Recently, unexplained excess events in the DAMA/LIBRA, CoGeNT, and CRESST-II experiments have been interpreted as evidence of scattering from WIMPs with masses ~10 GeV and spin-independent scattering cross sections of 10-41-10-40 cm2. The Cryogenic Dark Matter Search (CDMS II) attempts to identify WIMP interactions using an array of cryogenic germanium and silicon particle detectors located at the Soudan Underground Laboratory in northern Minnesota. In this dissertation, data taken by CDMS II are reanalyzed using a 2 keV recoil energy threshold to increase the sensitivity to WIMPs with masses ~10 GeV. These data disfavor an explanation for the DAMA/LIBRA, CoGeNT, and CRESST-II results in terms of spin-independent elastic scattering of WIMPs with masses ≲12 GeV, under standard assumptions. At the time of publication, they provided the strongest constraints on spin-independent elastic scattering from 5-9 GeV, ruling out previously unexplored parameter space. To detect WIMPs or exclude the remaining parameter space favored by the most popular models will ultimately require detectors with target masses ≳1 ton, requiring an increase in mass by more than two orders of magnitude over CDMS II. For cryogenic detectors such as CDMS, scaling to such large target masses will require individual detector elements to be fabricated more quickly and cheaply, while maintaining the nearly background-free operation of the existing experiment. We describe the development of athermal phonon mediated particle detectors using Microwave Kinetic Inductance Detectors (MKIDs), which could provide a simpler path to extending the CDMS detector technology to the ton scale. Results from prototype devices have demonstrated energy resolutions as good as σ = 0.55 keV at 30 keV, comparable to existing CDMS II detectors. Such designs can be scaled to kg-scale detector elements, while reducing the complexity of the detector fabrication and cryogenic readout electronics relative to existing designs. Since MKIDs are naturally multiplexed in the frequency domain, MKID-based designs also allow much finer pixelization of the phonon sensor, which is expected to enhance background rejection for large detectors while simultaneously reducing the number of wires needed to read out the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperCDMS Prototype Detector Design and Testing

A substantial amount of astrophysical evidence indicates that approximately a quarter of all energy in the universe is composed of a nonluminous, and nonbaryonic \dark" matter. Of the potential dark matter particle candidates, Weakly Interacting Massive Particles, or WIMPs, is particularly well motivated. As a means to directly detect WIMP interactions with baryonic matter, the Cryogenic Dark Matter Search (CDMS) project was established, operating at the Soudan Underground Laboratory from 2003 - 2015, under the CDMS II and SuperCDMS Soudan experiments. CDMS detectors simultaneously measure the ionization and phonon energies of recoil events in Si and Ge crystals kept at cryogenic temperatures in a low-background environment. The ratio of ionization energy to recoil energy serves as a discrimination parameter to separate nuclear recoil events from the electron-recoil background. The next installation, SuperCDMS SNOLAB, is preparing for future operation, with an initial payload of eighteen Ge and six Si, 100 mm diameter, 33 mm thick detectors. Of this initial payload, eight Ge and four Si detectors will operate in a high-voltage ( 100 V) mode, which have an increased sensitivity to low-mass WIMPs due to decreased energy thresholds. The SuperCDMS test facility at University of Minnesota aids in the detector R&D and characterization of prototype detectors, as part of the scale-up eort for Super- CDMS SNOLAB. This thesis presents the rst full ionization and phonon characterization study of a 100 mm diameter, 33 mm thick prototype Ge detector with interleaved phonon and ionization channels. Measurements include ionization collection eciency, surface event rejection capabilities, and successful demonstration of nuclear recoil event discrimination. Results indicate that 100 mm diameter, interleaved Ge detectors show potential for use in SuperCDMS SNOLAB. As part of detector R&D, the Minnesota test facility also looks beyond the next stage of SuperCDMS, investigating larger individual detectors as a means to easily scale up the sensitive mass of future searches. This thesis presents the design and initial testing results of a prototype 150 mm diameter, 33 mm thick silicon ionization detector, which is 5.2 times larger than those used in SuperCDMS at Soudan and 2.25 times larger than those planned for use at SuperCDMS SNOLAB. In addition, the detector was operated with contact-free ionization electrodes to minimize bias leakage currents, which can limit operation at high bias voltages. The results show promise for the operation of both large volume silicon detectors and contact-free ionization electrodes for scaling up detector mass and bias.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NORSAR Final Scientific Report Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Correlation detection is a relatively new approach in seismology that offers significant advantages in increased sensitivity and event screening over standard energy detection algorithms. The basic concept is that a representative event waveform is used as a template (i.e. matched filter) that is correlated against a continuous, possibly multichannel, data stream to detect new occurrences of that same signal. These algorithms are therefore effective at detecting repeating events, such as explosions and aftershocks at a specific location. This final report summarizes the results of a three-year cooperative project undertaken by NORSAR and Lawrence Livermore National Laboratory. The overall objective has been to develop and test a new advanced, automatic approach to seismic detection using waveform correlation. The principal goal is to develop an adaptive processing algorithm. By this we mean that the detector is initiated using a basic set of reference ('master') events to be used in the correlation process, and then an automatic algorithm is applied successively to provide improved performance by extending the set of master events selectively and strategically. These additional master events are generated by an independent, conventional detection system. A periodic analyst review will then be applied to verify the performance and, if necessary, adjust and consolidate the master event set. A primary focus of this project has been the application of waveform correlation techniques to seismic arrays. The basic procedure is to perform correlation on the individual channels, and then stack the correlation traces using zero-delay beam forming. Array methods such as frequency-wavenumber analysis can be applied to this set of correlation traces to help guarantee the validity of detections and lower the detection threshold. In principle, the deployment of correlation detectors against seismically active regions could involve very large numbers of very specific detectors. To meet this challenge, we have examined two strategies: (1) use of subspace detectors, a multi-dimensional extension of correlators, which allow representation and detection of signals exhibiting some degree of variation; and (2) autonomous calibration of many subspace and correlation detectors in an adaptive detection framework, subject to analyst review. Because correlation detectors are relatively new to seismology, a significant amount of research on how to tune these detectors has been needed to address later calibration efforts that will arise as they are adopted for operational use. We have approached these challenges by carrying out a number of case studies, encompassing various monitoring scenarios such as earthquake aftershock sequences and swarms, recurring mining explosions, other types of explosions, and rockbursts. We have studied several different geographical regions (the European Arctic, Central Asia, and the western United States). We have drawn on available Ground Truth data in assessing the results of the various processing schemes. In all cases, we have benefited from the high-quality seismic arrays or networks available in these regions, and we have thus been able to evaluate the performance of array-based correlation processing under a variety of conditions. The main results of the project are summarized as follows: (1) Array-based waveform correlation has been demonstrated to lower significantly detection thresholds in comparison with standard single-channel waveform correlation. (2) Frequency-wavenumber analysis of the correlation traces on a small-aperture array provides an effective method for screening out a certain category of false alarms, and can therefore be used to improve detector sensitivity by lowering the threshold for automatic array detection. (3) We have developed and tested a framework for autonomous correlation detection. The framework comprises a set of conventional (STA/LTA) detectors on a collection of array beams, augmented by correlation and subspace detectors. The detectors are applied in parallel. (4) We have experimentally tested the processing of a large aftershock sequence using various transformations of the signals from the main event to construct what we denote an incoherent correlation detector or characteristic function correlation detector. (5) An important application of multi-channel waveform correlation is to identify instances of erroneous instrumental timing. We provide examples of detected timing errors on single channels of an array, as well as on a remote three-component station.

58 GEOSCIENCES↗

Fabrication of Pop-up Detector Arrays on Si Wafers

High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way, preparing us for the next step of the experiment, the thermal test.

Li, Mary J.↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIgh Rate X-ray Fluorescence Detector

The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair.

47 OTHER INSTRUMENTATION↗

Assessment of MODIS RSB Detector Uniformity Using Deep Convective Clouds

For satellite sensor, the striping observed in images is typically associated with the relative multiple detector gain difference derived from the calibration. A method using deep convective cloud (DCC) measurements to assess the difference among detectors after calibration is proposed and demonstrated for select reflective solar bands (RSBs) of the Moderate Resolution Imaging Spectroradiometer (MODIS). Each detector of MODIS RSB is calibrated independently using a solar diffuser (SD). Although the SD is expected to accurately characterize detector response, the uncertainties associated with the SD degradation and characterization result in inadequacies in the estimation of each detector's gain. This work takes advantage of the DCC technique to assess detector uniformity and scan mirror side difference for RSB. The detector differences for Terra MODIS Collection 6 are less than 1% for bands 1, 3-5, and 18 and up to 2% for bands 6, 19, and 26. The largest difference is up to 4% for band 7. Most Aqua bands have detector differences less than 0.5% except bands 19 and 26 with up to 1.5%. Normally, large differences occur for edge detectors. The long-term trending shows seasonal oscillations in detector differences for some bands, which are correlated with the instrument temperature. The detector uniformities were evaluated for both unaggregated and aggregated detectors for MODIS band 1 and bands 3-7, and their consistencies are verified. The assessment results were validated by applying a direct correction to reflectance images. These assessments can lead to improvements to the calibration algorithm and therefore a reduction in striping observed in the calibrated imagery.

Clouds↗

Silicon Detectors-Tools for Discovery in Particle Physics

Since the first application of Silicon strip detectors in high energy physics in the early 1980ies these detectors have enabled the experiments to perform new challenging measurements. With these devices it became possible to determine the decay lengths of heavy quarks, for example in the fixed target experiment NA11 at CERN. In this experiment Silicon tracking detectors were used for the identification of particles containing a c-quark. Later on, the experiments at the Large Electron Positron collider at CERN used already larger and sophisticated assemblies of Silicon detectors to identify and study particles containing the b-quark. A very important contribution to the discovery of the last of the six quarks, the top quark, has been made by even larger Silicon vertex detectors inside the experiments CDF and D0 at Fermilab. Nowadays a mature detector technology, the use of Silicon detectors is no longer restricted to the vertex regions of collider experiments. The two multipurpose experiments ATLAS and CMS at the Large Hadron Collider at CERN contain large tracking detectors made of Silicon. The largest is the CMS Inner Tracker consisting of 200 m{sup 2} of Silicon sensor area. These detectors will be very important for a possible discovery of the Higgs boson or of Super Symmetric particles. This paper explains the first applications of Silicon sensors in particle physics and describes the continuous development of this technology up to the construction of the state of the art Silicon detector of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Effect On Gas Electron Multiplier Detector Performance

Gas Electron Multiplier (GEM) detector is a gas device with high gain and high efficiency. These detectors use chemically perforated 65 {mu}m thick copper clad Kapton polyimide foils. Given its potential for detecting X-rays and other radiations, GEM detectors may be used in an environment with high radioactivity. The Kapton foils manufacturer, Du Pont Inc., claims that the foils are radioactive resistant. To verify whether the GEM detector performance is affected by the exposure to radiation, several GEM foils were irradiated to a {sup 60}Co source at the gamma-ray irradiation facility at Sterigenics, Tustin, CA. Four sets of GEM foils were exposed to the level of 10 kGy, 100 kGy, 1,000 kGy and 10,000 kGy. The output signal from the GEM detectors with irradiated GEM foils were measured and compared to the detector with no irradiation. We observed that the shapes of the peaks from 5.9 KeV {sup 55}Fe X-ray were distorted and that the detector gain increased compared to that of the un-irradiated detector. In particular, the detector with 10,000 kGy irradiation appeared to have the biggest peak distortion and increased gain. It was also found from that additional electrons from radiation-induced free radicals in the Kapton film contribute to output signal of the irradiated GEM detectors. Further studies are needed to explain the mechanism of these detector performance changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗