Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Characterization of Thin Film Microstrip Lines on Polyimide

This paper presents an in depth characterization of thin film microstrip (TFMS) lines fabricated on Dupont PI-2611 polyimide. Measured attenuation and effective dielectric constant is presented for TFMS lines with thicknesses from 2.45-7.4 microns and line widths from 5-34.4 microns over the frequency range of 1-110 GHz. The attenuation is separated into conductor and dielectric losses to determine the loss tangent of Dupont PI-2611 polyimide over the microwave frequency range. In addition, the measured characteristics are compared to closed form equations for a and eff from the literature. Based on the comparisons, recommendations for the best dosed form design equations for TFMS are made.

Ponchak, George E.↗

Chitosan–Gelatin @ Tin (IV) Tungstatophosphate Nanocomposite Ion Exchanger: Synthesis, Characterization and Applications in Environmental Remediation

The present study reported the synthesis of novel organic–inorganic hybrid nanocomposite by incorporating tin (IV) based ion exchanger into the hybrid polymer network of chitosan and gelatin prepared under vacuum for the efficient removal of heavy metal ions and toxic dyes from an aqueous fluid. The physicochemical studies such as ion exchange capacity (IEC), chemical stability, thermal stability, pH titration and distribution behaviour studies were also carried out to determine the cation exchange behaviour of the material. The surface morphology and structural properties were studied by the techniques such as FTIR, FESEM, EDS, TEM and XRD. Distribution studies confirmed the synthesized CG/STPNC had the highest selectivity for Pb{sup 2+} ions (85.3 mL/g). Maximum adsorption of methylene blue (82%) was achieved within 240 min at 500 mg of adsorbent dose, 10 mg/L of the initial concentration of dye, pH of 7 and 30 °C of temperature. Adsorption kinetic data fitted well with pseudo-second order rate model with R{sup 2} = 0.995. The correlation value 0.95 and favourable R{sub L} = 0.21 of adsorption data suggested better fit for Langmuir adsorption. Thus the synthesized nanocomposite ion exchanger was found to be a promising cation exchanger as well as an adsorbent for heavy metal ion and dye removal from textile industrial effluents. Graphical abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Regional Relative Risk, a Physics-Based Metric for Characterizing Airborne Infectious Disease Transmission

Airborne infectious disease transmission events occur over a wide range of spatial scales and can be an important means of disease transmission. Physics- and biology-based models can assist in predicting airborne transmission events, overall disease incidence, and disease control strategy efficacy. We describe a new theory that extends current approaches for the case in which an individual is infected by a single airborne particle, including the scenario in which numerous infectious particles are present in the air but only one causes infection. A single infectious particle can contain more than one pathogenic microorganism and be physically larger than the pathogen itself. This approach allows robust relative risk estimates even when there is wide variation in (i) individual exposures and (ii) the individual response to that exposure (the pathogen dose-response function can take any mathematical form and vary by individual). Based on this theory, we propose the regional relative risk—a new metric, distinct from the traditional relative risk metric, that compares the risk between two regions. In theory, these regions can range from individual rooms to large geographic areas. In this paper, we apply the regional relative risk metric to outdoor disease transmission events over spatial scales ranging from 50 m to 20 km, demonstrating that in many common cases minimal input information is required to use the metric. Also, we demonstrate that the model predictions are consistent with data from prior outbreaks. Future efforts could apply and validate this theory for other spatial scales, such as transmission within indoor environments. This work provides context for (i) the initial stages of an airborne disease outbreak and (ii) larger-scale disease spread, including unexpected low-probability disease “sparks” that potentially affect remote populations, a key practical issue in controlling airborne disease outbreaks.

54 ENVIRONMENTAL SCIENCES↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

Identification of interstratified mica and pyrophyllite monolayers within chlorite using advanced scanning/transmission electron microscopy

Interstratified clay minerals reflect the weathering degree and record climatic conditions and the pedogenic processes in the soil. It is hard to distinguish a few layers of interstratified clay minerals from the chlorite matrix, due to their similar two-dimensional tetrahedral-octahedral-tetrahedral (TOT) structure and electron-beam sensitive nature during transmission electron microscopy (TEM) imaging. In this study, we used multiple advanced TEM techniques including low-dose high-resolution TEM (HRTEM), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) imaging combined with energy-dispersive spectroscopic (EDS) mapping to study interstratified layers in a chlorite sample from Changping, Beijing, China. We demonstrated an interstratified mica or pyrophyllite monolayer could be well distinguished from the chlorite matrix by projected atomic structures, lattice spacings, and chemical compositions with advanced TEM techniques. Further investigation showed two different transformation mechanisms from mica or pyrophyllite to chlorite: either a 4 A increase or decrease in the lattice spacing. Lastly, this characterization approach can be extended to the studies of other electron-beam sensitive minerals.

36 MATERIALS SCIENCE↗

WE-FG-202-10: Assessing Hepatocellular Carcinoma (HCC) Response to SBRT Using DCE-MRI

Purpose: To investigate the feasibility of using DCE-MRI to assess treatment response of HCC to SBRT. Methods: For seven liver HCC patients treated by photon SBRT with radiation dose ranging from 35 to 50 Gy in 5 fractions, T1-weighted DCE-MRI was performed before and at 1–3 months after the treatment. Each study included one pre-contrast and five post Gd-EOB-DTPA-enhanced imaging series. The target tumor and the liver were manually outlined on the arterial phase images. Then, a regional deformable image registration was applied to align liver volumes at different phases in order to compensate respiratory and cardiac motions. An unsupervised fuzzy c-means clustering technique was carried out to partition the tumor voxels into a number of groups based on their enhancement patterns over time. The representative kinetic curve of the tumor was selected as the one with the maximum enhancement. Six semi-quantitative features were extracted to depict the maximum contrast enhancement, uptake rate, washout rate, time to peak, the area under the kinetic curve (AUKC), as well as the ratio of the most enhanced area in each tumor. The change of these feature values after SBRT was compared using Wann-Whiteney test to characterize the tumor response to RT. Results: Eight HCCs from these seven patients were included in this retrospective study, in which four were identified to respond well to SBRT. The responding tumors showed reduced enhancement after SBRT while the non-responding tumors had steady or even enhanced kinetic dynamics. The median AUKC change after SBRT was −0.65 for responding tumors and 1.0165 for non-responding tumors (p=0.029) Conclusion: The preliminary results demonstrate that DCE-MRI has the potential to monitor the effects of SBRT in patients with HCC. We are expanding our database and developing more quantitative imaging biomarkers in the future study.

60 APPLIED LIFE SCIENCES↗

CMAS behavior of yttrium aluminum garnet (YAG) and yttria-stabilized zirconia (YSZ) thermal barrier coatings

Calcium magnesium aluminosilicate (CMAS) that is formed from the ingested deposits in gas turbines degrades thermal barrier coatings (TBCs), especially for the most widely used material; yttria-stabilized zirconia (YSZ). In the present work, we examine the behavior of yttrium aluminum garnet (YAG) as an alternative material for TBCs. CMAS interaction studies were conducted by making composite pellets of YAG-CMAS and YSZ-CMAS powders. These pellets, after being subjected to heat treatment between 1100 °C and 1500 °C were characterized by X-ray Diffraction (XRD), scanning electron microscopy (SEM) and Energy-dispersive X-ray spectroscopy (EDS), which showed YAG to be almost inert to CMAS whereas YSZ exhibited significant phase changes. To test the behavior of TBCs with YAG and 8YSZ as the topcoat material in a CMAS environment, cyclic furnace tests were conducted in which a controlled amount of CMAS was applied and then the samples were cycled to failure. In addition, to simulate the continuous accumulation of CMAS expected in service, a cyclic furnace test was devised in which a small dose of aqueous solution of CMAS was applied on TBC specimens at the start of every cycle until the samples were cycled to failure. In all these tests YAG TBCs outperformed YSZ in terms of durability. In conclusion, the mechanisms of CMAS attack are described and the relative resistance of YAG and YSZ is shown to be consistent with the Optical Basicity (OB) theory.

36 MATERIALS SCIENCE↗

Prostanoid-induced expression of matrix metalloproteinase-1 messenger ribonucleic acid in rat osteosarcoma cells

Individual prostanoids have distinct potencies in activating intracellular signaling pathways and regulating gene expression in osteoblastic cells. The E-series prostaglandins (PGs) are known to stimulate matrix metalloproteinase-1 (MMP-1) synthesis and secretion in certain rodent and human osteoblastic cells, yet the intracellular events involved remain unclear. To further characterize this response and its signal transduction pathway(s), we examined prostanoid-induced expression of the MMP-1 gene in the rat osteoblastic osteosarcoma cell line UMR 106-01. Northern blot analysis demonstrated that prostaglandin E2 (PGE2) and PGE1 were very potent stimulators (40-fold) of MMP-1 transcript abundance, PGF2 alpha and prostacyclin were weak stimulators (4-fold), and thromboxane-B2 had no effect. The marked increase in MMP-1 transcript abundance after PGE2 treatment was first detected at 2 h, became maximal at 4 h, and persisted beyond 24 h. This response was dose dependent and elicited maximal and half-maximal effects with concentrations of 10(-6) and 0.6 x 10(-7) M, respectively. Cycloheximide, a protein synthesis inhibitor, completely blocked this effect of PGE2, suggesting that the expression of other genes is required. Nuclear run-on experiments demonstrated that PGE2 rapidly activates MMP-1 gene transcription, with a maximal increase at 2-4 h. The second messenger analog, 8-bromo-cAMP, mimicked the effects of PGE2 by stimulating a dose-dependent increase in MMP-1 messenger RNA (mRNA) levels, with a maximal effect quantitatively similar to that observed with PGE2. Thus, in UMR 106-01 cells, different prostanoids have distinct potencies in stimulating MMP-1 mRNA abundance. Our data suggest that PGE2 stimulation of MMP-1 synthesis is due to activation of MMP-1 gene transcription and a subsequent marked increase in MMP-1 mRNA abundance. This effect is dependent on de novo protein synthesis and is mimicked by protein kinase-A activation.

NASA Discipline Musculoskeletal↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 1 Report

This report supports Critical/Subcritical Experiment Decision 1 (CED-1) for Integral Experiment Request (IER) 498, a shielding benchmark produced using the Godiva IV critical assembly at the National Critical Experiments Research Center (NCERC). Shielding benchmarks are datasets collected to provide a comparison for computer models that simulate the effect of shielding on radiation transmission from a source to a detector. The purpose of a CED-1 report is to produce a conceptual design for an integral experiment and to identify the long lead-time items. The design presented in this report favors certain detailed design options such as material selections. However, alternative options can be selected as the project evolves. Dimensions are specified only as needed to evaluate feasibility and performance. Development of Criticality Accident Alarm System (CAAS) shielding benchmarks supports two main programmatic needs. The first need is to improve confidence in models of facilities that house nuclear material handling operations. Better models can support effective CAAS detector placement when criticality may result in dose, and it enables more accurate analysis of criticality accident impacts at various locations in a facility. A key quantity that can be verified is the secondary gamma production caused by neutron interactions with various materials. The second programmatic need supported by shielding benchmarks is the ongoing development of methods being integrated into nuclear simulation codes such as the Monte Carlo N-Particle (MCNP) transport code and the SCALE code system used in efforts funded by the Nuclear Criticality Safety Program (NCSP). Previous work performed under the International Criticality Safety Benchmark Experimental Program (ICSBEP) to produce shielding benchmark data is primarily limited to a set of measurements at the SILENE critical assembly at the Valduc facility in France. The experiment used an open configuration and a burst mode operation, which limited detector options to thermoluminescent dosimeters (TLDs) and activation foils. Because TLDs do not record gamma spectra, it was difficult to verify the gamma energy spectrum from the experiment. In this work, the Godiva IV assembly will be used because it is a fast system capable of producing a wide range of source strengths, including super-prompt critical bursts. The room return for the facility is expected to be substantial and challenging to characterize, so a more closed, shielded experimental configuration is considered. Furthermore, because the physics of radiation transport outside the assembly does not change between the burst mode and the delayed critical mode, it is anticipated that most measurements will be made with the Godiva IV assembly in delayed critical mode, operating within a range that will allow electronic counters to collect accurate data. Scoping calculations concluded that a workable room return shield is comprised of 40 cm of 5% borated polyethylene backed by 7 cm of lead. This configuration was shown to produce a ratio of signal–to–room return of over 100 for up to 2 mean free paths of shield sample material, and over 10 for up to 4 mean free paths of shield sample material, ensuring that useful results can be obtained. With no shielding sample in the room return shield, it was shown that the neutron and gamma spectra do not appreciably change with a change in room size. This scoping calculation does not preclude the use of tungsten powder in a binder, some other effective gamma shielding material, or a hybrid design. Dose rates for various source intensities at an unshielded detector are listed herein to inform detector selection during CED-2, and calibration chains are identified. Preliminary estimates of costs and schedules are outlined but remain to be verified. Values could double or triple as estimates become more accurate and are principally included here to demonstrate feasibility. Preliminary estimates indicate that the apparatus can be installed within a feasible schedule and budget. Two measurements per day are assumed. Producing a shielding benchmark at NCERC using the Godiva IV assembly has been shown to be feasible, with manageable uncertainties and risks. A clear, continuing need for shielding benchmark data remains present, and this report identifies and evaluates a method for creating integrated shielding benchmark datasets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of 63 MeV proton irradiation on the performance of MWIR InGaAs/InAsSb nBn photodetectors

An investigation into the effects of 63 MeV proton irradiation on high-sensitivity mid-wave infrared InGaAs/InAsSb nBn devices is performed. Three different structures with various absorber region doping profiles are irradiated and characterized to assess their impact on performance degradation. Minority carrier lifetime is measured using time-resolved photoluminescence and lifetime damage factors are assessed. The majority carrier concentration is determined via capacitance–voltage measurements and dopant introduction rates are calculated. An analysis of dark current density is performed using these material parameters, revealing a reduction in mobility with proton fluence and the emergence of a proton-induced trap energy level. Quantum efficiency is calculated at each proton fluence, and quantum efficiency damage factors show that the graded doping structure exhibits the least reduction of quantum efficiency with dose, attributed to its effective mobility enhancement. Conclusively, detector sensitivity, assessed via shot-noise limited noise-equivalent irradiance, shows that the graded doping structure is the least susceptible to high energy proton irradiation-induced performance degradation.

Physics↗

The Application of FLUKA to Dosimetry and Radiation Therapy

Monte Carlo transport codes like FLUKA are useful for many purposes, and one of those is the simulation of the effects of radiation traversing the human body. In particular, radiation has been used in cancer therapy for a long time, and recently this has been extended to include heavy ion particle beams. The advent of this particular type of therapy has led to the need for increased capabilities in the transport codes used to simulate the detailed nature of the treatment doses to the Y ~ ~ O U S tissues that are encountered. This capability is also of interest to NASA because of the nature of the radiation environment in space.[l] While in space, the crew members bodies are continually being traversed by virtually all forms of radiation. In assessing the risk that this exposure causes, heavy ions are of primary importance. These arise both from the primary external space radiation itself, as well as fragments that result from interactions during the traversal of that radiation through any intervening material including intervening body tissue itself. Thus the capability to characterize the details of the radiation field accurately within a human body subjected to such external 'beams" is of critical importance.

Wilson, Thomas L.↗

Edge termination in vertical GaN diodes: Electric field distribution probed by second harmonic generation

We characterized the electric field distribution of GaN-on-GaN p–n diodes with partially compensated ion-implanted edge termination (ET) using an electric field induced second harmonic generation technique (EFISHG). The distributed electric field from the anode to the outer edge of the ET demonstrates the effectiveness of the ET structure. However, EFISHG also shows that its effectiveness is strongly dependent on the acceptor charge distribution in the ET's partially compensated layer (PC). A generally lower amount of acceptor charge can be inferred from the measured electric field distribution resulting from excessive ion implantation energy or dose during ET fabrication and causing lower than optimal breakdown voltage. Localized field crowding can be observed when the remaining acceptors uncompensated by the implant in the PC layer are nonuniformly distributed around the periphery of the devices. Important information can be obtained from these direct electric field measurements and used for optimizing the device design and fabrication process.

Cao, Yuke↗

Anisotropic multiband superconductivity in 2 M − WS 2 probed by controlled disorder

The intrinsically superconducting Dirac semimetal 2 M − WS 2 is a promising candidate for realizing proximity-induced topological superconductivity in its protected surface states. A precise characterization of the bulk superconducting state is essential to understand the nature of surface superconductivity in the system. Here, we report a detailed experimental study of the temperature-dependent London penetration depth, λ ( T ) , the upper critical field, H c 2 ( T ) , and the effects of nonmagnetic disorder on these quantities, as well as on the superconducting transition temperature T c in single crystals of 2 M − WS 2 . We observe a power-law variation of λ ( T ) ∝ T 3 at temperatures below 0.35 T c . Nonmagnetic pointlike disorder induced by 2.5 MeV electron irradiation at various doses results in a significant suppression of T c . These observations are markedly different from expectations for a fully gapped isotropic s − wave superconductor. Together with the substantial increase of slope, d H c 2 / d T | T = T c , with increasing disorder, our results suggest a strongly anisotropic s + + multiband superconducting state. These results have direct consequences for the expected proximity-induced superconductivity of the topological surface states. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural materials for space applications

The long-term performance of structural materials in the space environment is a key research activity within NASA. The primary concerns for materials in low Earth orbit (LEO) are atomic oxygen erosion and space debris impact. Atomic oxygen studies have included both laboratory exposures in atomic oxygen facilities and flight exposures using the Shuttle. Characterization of atomic oxygen interaction with materials has included surface recession rates, residual mechanical properties, optical property measurements, and surface analyses to establish chemical changes. The Long Duration Exposure Facility (LDEF) is scheduled to be retrieved in 1989 and is expected to provide a wealth of data on atomic oxygen erosion in space. Hypervelocity impact studies have been conducted to establish damage mechanisms and changes in mechanical properties. Samples from LDEF will be analyzed to determine the severity of space debris impact on coatings, films, and composites. Spacecraft placed in geosynchronous Earth orbit (GEO) will be subjected to high doses of ionizing radiation which for long term exposures will exceed the damage threshold of many polymeric materials. Radiation interaction with polymers can result in chain scission and/or cross-linking. The formation of low molecular weight products in the epoxy plasticize the matrix at elevated temperatures and embrittle the matrix at low temperatures. This affects both the matrix-dominated mechanical properties and the dimensional stability of the composite. Embrittlement of the matrix at low temperatures results in enhanced matrix microcracking during thermal cycling. Matrix microcracking changes the coefficient of thermal expansion (CTE) of composite laminates and produces permanent length changes. Residual stress calculations were performed to estimate the conditions necessary for microcrack development in unirradiated and irradiated composites. The effects of UV and electron exposure on the optical properties of transparent polymer films were also examined to establish the optimum chemical structure for good radiation resistance. Thoughts on approaches to establishing accelerated testing procedures are discussed.

Tenney, Darrel R.↗

Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy

Purpose: The development of clinical trials is underway to use 4-dimensional computed tomography (4DCT) ventilation imaging to preferentially spare functional lung in patients undergoing radiation therapy. The purpose of this work was to generate data to aide with clinical trial design by retrospectively characterizing dosimetric and functional profiles for patients with different stages of lung cancer. Methods and Materials: A total of 118 lung cancer patients (36% stage I and 64% stage III) from 2 institutions were used for the study. A 4DCT-ventilation map was calculated using the patient's 4DCT imaging, deformable image registration, and a density-change–based algorithm. To assess each patient's spatial ventilation profile both quantitative and qualitative metrics were developed, including an observer-based defect observation and metrics based on the ventilation in each lung third. For each patient we used the clinical doses to calculate functionally weighted mean lung doses and metrics that assessed the interplay between the spatial location of the dose and high-functioning lung. Results: Both qualitative and quantitative metrics revealed a significant difference in functional profiles between the 2 stage groups (P<.01). We determined that 65% of stage III and 28% of stage I patients had ventilation defects. Average functionally weighted mean lung dose was 19.6 Gy and 5.4 Gy for stage III and I patients, respectively, with both groups containing patients with large spatial overlap between dose and high-function regions. Conclusion: Our 118-patient retrospective study found that 65% of stage III patients have regionally variant ventilation profiles that are suitable for functional avoidance. Our results suggest that regardless of disease stage, it is possible to have unique spatial interplay between dose and high-functional lung, highlighting the importance of evaluating the function of each patient and developing a personalized functional avoidance treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗