Search NASA⌕ Search

SEARCH · Search NASA

Results for “Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A Global Review of Incentive Programs to Accelerate Energy-Efficient Appliances and Equipment

Incentive programs are an essential policy tool to move the market toward energy-efficient products. They offer a favorable complement to mandatory standards and labeling policies by accelerating the market penetration of energy-efficient products above equipment standard requirements and by preparing the market for increased future mandatory requirements. They sway purchase decisions and in some cases production decisions and retail stocking decisions toward energy-efficient products. Incentive programs are structured according to their regulatory environment, the way they are financed, by how the incentive is targeted, and by who administers them. This report categorizes the main elements of incentive programs, using case studies from the Major Economies Forum to illustrate their characteristics. To inform future policy and program design, it seeks to recognize design advantages and disadvantages through a qualitative overview of the variety of programs in use around the globe. Examples range from rebate programs administered by utilities under an Energy-Efficiency Resource Standards (EERS) regulatory framework (California, USA) to the distribution of Eco-Points that reward customers for buying efficient appliances under a government recovery program (Japan). We found that evaluations have demonstrated that financial incentives programs have greater impact when they target highly efficient technologies that have a small market share. We also found that the benefits and drawbacks of different program design aspects depend on the market barriers addressed, the target equipment, and the local market context and that no program design surpasses the others. The key to successful program design and implementation is a thorough understanding of the market and effective identification of the most important local factors hindering the penetration of energy-efficient technologies.

25 ENERGY STORAGE↗

Higher Efficiency HVAC Motors

The objective of this project was to design and build a cost competitive, more efficient heating, ventilation, and air conditioning (HVAC) motor than what is currently available on the market. Though different potential motor architectures among QMP’s primary technology platforms were investigated and evaluated, including through the building of numerous prototypes, the project ultimately focused on scaling up QM Power, Inc.’s (QMP) Q-Sync permanent magnet synchronous motors from available sub-fractional horsepower (HP) sizes for commercial refrigeration fan applications to larger fractional horsepower sizes appropriate for HVAC applications, and to add multi-speed functionality. The more specific goal became the research, design, development, and testing of a prototype 1/2 HP Q-Sync motor that has at least two operating speeds and 87% peak efficiency compared to incumbent electronically commutated motors (EC or ECM, also known as brushless direct current (DC) motors), the heretofore highest efficiency HVACR fan motor solution, at approximately 82% peak efficiency. The resulting motor prototype built achieved these goals, hitting 90% efficiency and .95 power factor at full load and speed, and 80% efficiency and .7 power factor at half speed. Q-Sync, developed in part through a DOE SBIR grant (Award # DE-SC0006311), is a novel, patented motor technology that improves on electronically commutated permanent magnet motors through an advanced electronic circuit technology. It allows a motor to “sync” with the alternating current (AC) power flow. It does so by eliminating the constant, wasteful power conversions from AC to DC and back to AC through the synthetic creation of a new AC wave on the primary circuit board (PCB) by a process called pulse width modulation (PWM; aka electronic commutation) that is incessantly required to sustain motor operation in an EC permanent magnet motor. The Q-Sync circuit improves the power factor of the motor by removing all failure prone capacitors from the power stage. Q-Sync’s simpler electronics also result in higher efficiency because it eliminates the power required by the PCB to perform the obviated power conversions and PWM processes after line synchronous operating speed is reached in the first 5 seconds of operation, after which the PWM circuits drop out and a much less energy intensive “pass through” circuit takes over, allowing the grid-supplied AC power to sustain the motor’s ongoing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Energy Efficiency in Developing Countries: Lessons Learned from Low-Income Residential Experiences in Industrialized Countries

Energy efficiency has great potential to address economic development, energy security, and environmental protection around the world and in developing countries in particular. Low-income residents of developing countries stand to gain significantly from energy efficiency investments. This report presents lessons learned in delivering energy-efficiency programs for low-income households that are taken from experiences in the United States and other member countries of the Organisation for Economic Co-operation and Development (OECD). Lessons learned in delivering energy-efficiency programs to low-income households of industrial countries are summarized from the perspectives of program design, program delivery, and institutions in order to provide best practices that are applicable to countries in different development stages. This report discusses who to target, how to reduce energy burden, coordinating institutional stakeholders, which efficiency tools to use, how to fund low-income energy efficiency programs, screening tools to prioritize projects, outreach strategies, and evaluation methods. The report concludes with a framework for understanding different levels of energy-efficiency interventions based on institutional capacity, political willpower, and resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supercritical Reforming of Wet Ethanol for High Efficiency Direct-injection Heavy-duty Compression-ignition Engines

The purpose of the research was to investigate the potential of using a mature bio-fuel in heavy-duty compression ignition engines. By co-optimizing both the fuel characteristics and engine system the potential for a superior outcome was demonstrated. The use of wet bio-ethanol eliminates the majority of the energy intensive distilling and dehydrating fuel production processes, which moves the fuel towards carbon neutral and also lowers the fuel costs. The relatively high water content of the resulting fuel is leveraged in the proposed novel combustion system by incorporating an integrated high efficiency exhaust waste heat recovery system. This results in significantly higher thermal efficiency. In addition the combustion system features low criteria pollutant emissions and the potential to reduce the initial cost of the engine system hardware. Substantial societal benefits are demonstrated through the co-optimization of the fuel and engine system. A computational proof-of-concept study has been performed to demonstrate the potential benefits of a novel wet ethanol heavy-duty compression ignition combustion system featuring integrated exhaust waste heat recovery. A combined in-cylinder closed cycle 3D computational fluid dynamics (CFD) - 1D engine system simulation approach was used. The models were validated to baseline engine data using diesel fuel and then applied to the wet ethanol study. The original concept was to maximize exhaust waste heat recovery through supercritical reforming of the wet ethanol fuel. Phase I simulation results indicated that the optimal solution for maximum engine efficiency gains were realized through maximizing thermo-mechanical recuperation with negligible fuel reformation. The results show the potential to achieve impressive gains in brake thermal efficiency (BTE) over the base diesel engine. The potential to increase BTE up to 20.9% over the base diesel engine was demonstrated, with even larger gains possible through reduced in-cylinder heat transfer losses. The majority of the efficiency gains were realized through integrated high efficiency exhaust waste heat recovery. The concept also has the potential to achieve future ultra-low NO x emissions standards and negligible engine-out soot emissions. The mixing controlled combustion of high temperature wet ethanol features relatively low engine-out NO x emissions without the need for exhaust gas recirculation (EGR). The soot free combustion enabled by the relatively high oxygen content of ethanol also allows for the use of stoichiometric mixing controlled combustion, which is not practical with diesel fuel. When stoichiometric combustion is used a simple passive 3-way catalyst can be used for exhaust emissions after-treatment and near zero tailpipe emissions. The Phase I simulations results have defined the system layout and requirements in preparation for the Phase II experimental proof-of-concept study. The potential applications of the research include most current applications of diesel engines. The Phase I study focused on heavy-duty on-highway class 8 trucks. However, virtually any application that requires highly efficient clean power generation would benefit from the novel engine system proposed. The results indicate substantial fuel cost savings and reduced greenhouse gas emissions with similar or reduced initial system hardware costs compared to modern diesel engine systems.

09 BIOMASS FUELS↗

Incentivizing Cold-Climate Efficiency in Juneau (Final Report)

This is the final technical report for the DOE EERE BTO project Incentivizing Cold-Climate Efficiency in Juneau. The project implemented a community energy campaign to deploy heat pumps and efficiency for residents of Juneau, in Southeast Alaska. The project helped Juneau make progress towards its renewable energy goal of reaching 80% renewable energy for space heating by 2045. The Incentivizing Cold-Climate Efficiency in Juneau (ICE-Juneau) project began in 2020 and concluded three years later in 2023. During that time, a group of implementation partners and a research advisory team instituted a beneficial electrification campaign to promote energy savings and carbon reduction in residences of Juneau, Alaska. The campaign, Thermalize Juneau, focused on the installation of single head ductless mini-split heat pumps along with other efficiency upgrades. Thermalize Juneau was the first campaign of its kind in Alaska. After several months of planning, registration opened to the public in early 2021, and over the course of six months 164 participants enrolled. Campaign staff provided education to homeowners on heat pumps and efficiency, and each participant received a one-on-one heat pump assessment using a custom Microsoft Excel-based calculator that estimated energy savings for their residence based on building characteristics and past utility bills. Participants could also obtain a free energy audit from one of the two local energy auditors to further inform their decision. A heat pump installer, electrician, and builder were selected via a competitive RFP process. Participants who felt ready to install a heat pump or other efficiency upgrades received a site visit and custom quote from each of these contractors free of charge, and if they still felt energy upgrades were right for them, could move forward with an individual contract. Participants received a $400 heat pump installation rebate, offered by the installer if 40 heat pump installations occurred through the campaign. Overall, the campaign facilitated 75 heat pump installations (including participants that went with another contractor or heat pump model) and 30 efficiency upgrades (including participants that went with another builder or did DIY upgrades). The campaign created 3 new jobs as the heat pump installer hired an administrative assistant and two apprentices over the course of the campaign. It also helped Juneau work toward achieving its renewable energy goal of 80% renewable energy for space heating by 2045 by upgrading houses from fuel oil to heat pumps powered by the hydropower electric grid. Researchers conducted four surveys to inform Thermalize Juneau and future energy campaigns. The first surveyed existing and prospective heat pump owners in Juneau to identify barriers the campaign could address and inform recruitment efforts. Entry and exit surveys provided information on participant demographics, goals, outcomes, and suggestions for improving future campaigns. And a final survey of community members who had not participated in Thermalize Juneau gave insight on ways future campaigns could include a greater diversity of participants so they could realize similar benefits. Researchers also used pre-campaign energy modeling to predict energy savings, which was then compared to the savings estimated through aggregation of heat pump assessments and energy audits, and later to actual energy savings of 10 participants who installed a heat pump and were able to provide complete energy use data sets. In addition to energy savings, and to assist the electric utility in future planning efforts, researchers analyzed the overall change in electric use across participants with energy data and heat pump installations. They also completed a life cycle cost analysis, showing positive net present values for those displacing a fuel oil appliance, and a more mixed case for those switching from electric baseboard. This project proved the feasibility of energy campaigns, with a goal of beneficial electrification, in cold, remote locations. The Thermalize Juneau team compiled a Guidebook to Thermalize Campaigns, available online. In addition to documenting what occurred in Alaska’s first thermalize campaign, it provides tips and resources for other communities wishing to implement a similar program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thin Film Packaging Solutions for High Efficiency OLED Lighting Products

The objective of the 'Thin Film Packaging Solutions for High Efficiency OLED Lighting Products' project is to demonstrate thin film packaging solutions based on SiC hermetic coatings that, when applied to glass and plastic substrates, support OLED lighting devices by providing longer life with greater efficiency at lower cost than is currently available. Phase I Objective: Demonstrate thin film encapsulated working phosphorescent OLED devices on optical glass with lifetime of 1,000 hour life, CRI greater than 75, and 15 lm/W. Phase II Objective: Demonstrate thin film encapsulated working phosphorescent OLED devices on plastic or glass composite with 25 lm/W, 5,000 hours life, and CRI greater than 80. Phase III Objective: Demonstrate 2 x 2 ft{sup 2} thin film encapsulated working phosphorescent OLED with 40 lm/W, 10,000 hour life, and CRI greater than 85. This report details the efforts of Phase III (Budget Period Three), a fourteen month collaborative effort that focused on optimization of high-efficiency phosphorescent OLED devices and thin-film encapsulation of said devices. The report further details the conclusions and recommendations of the project team that have foundation in all three budget periods for the program. During the conduct of the Thin Film Packaging Solutions for High Efficiency OLED Lighting Products program, including budget period three, the project team completed and delivered the following achievements: (1) a three-year marketing effort that characterized the near-term and longer-term OLED market, identified customer and consumer lighting needs, and suggested prototype product concepts and niche OLED applications lighting that will give rise to broader market acceptance as a source for wide area illumination and energy conservation; (2) a thin film encapsulation technology with a lifetime of nearly 15,000 hours, tested by calcium coupons, while stored at 16 C and 40% relative humidity ('RH'). This encapsulation technology was characterized as having less than 10% change in transmission during the 15,000 hour test period; (3) demonstrated thin film encapsulation of a phosphorescent OLED device with 1,500 hours of lifetime at 60 C and 80% RH; (4) demonstrated that a thin film laminate encapsulation, in addition to the direct thin film deposition process, of a polymer OLED device was another feasible packaging strategy for OLED lighting. The thin film laminate strategy was developed to mitigate defects, demonstrate roll-to-roll process capability for high volume throughput (reduce costs) and to support a potential commercial pathway that is less dependent upon integrated manufacturing since the laminate could be sold as a rolled good; (5) demonstrated that low cost 'blue' glass substrates could be coated with a siloxane barrier layer for planarization and ion-protection and used in the fabrication of a polymer OLED lighting device. This study further demonstrated that the substrate cost has potential for huge cost reductions from the white borosilicate glass substrate currently used by the OLED lighting industry; (6) delivered four-square feet of white phosphorescent OLED technology, including novel high efficiency devices with 82 CRI, greater than 50 lm/W efficiency, and more than 1,000 hours lifetime in a product concept model shelf; (7) presented and or published more than twenty internal studies (for private use), three external presentations (OLED workshop-for public use), and five technology-related external presentations (industry conferences-for public use); and (8) issued five patent applications, which are in various maturity stages at time of publication. Delivery of thin film encapsulated white phosphorescent OLED lighting technology remains a challenging technical achievement, and it seems that commercial availability of thin, bright, white OLED light that meets market requirements will continue to require research and development effort. However, there will be glass encapsulated white OLED lighting products commercialized in niche markets during the 2008 calendar year. This commercialization effort, the project team believes, will lead to increasing market attention and broader demand for more efficient, wide area general purpose white OLED lighting in the coming years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Audit Report "Department of Energy Efforts to Manage Information Technology Resources in an Energy-Efficient and Environmentally Responsible Manner"

The American Recovery and Reinvestment Act of 2009 emphasizes energy efficiency and conservation as critical to the Nation's economic vitality; its goal of reducing dependence on foreign energy sources; and, related efforts to improve the environment. The Act highlights the significant use of various forms of energy in the Federal sector and promotes efforts to improve the energy efficiency of Federal operations. One specific area of interest is the increasing demand for Federal sector computing resources and the corresponding increase in energy use, with both cost and environmental implications. The U.S. Environmental Protection Agency reported that, without aggressive conservation measures, data center energy consumption alone is expected to double over the next five years. In our report on Management of the Department's Data Centers at Contractor Sites (DOE/IG-0803, October 2008) we concluded that the Department of Energy had not always improved the efficiency of its contractor data centers even when such modifications were possible and practical. Despite its recognized energy conservation leadership role, the Department had not always taken advantage of opportunities to reduce energy consumption associated with its information technology resources. Nor, had it ensured that resources were managed in a way that minimized impact on the environment. In particular: (1) The seven Federal and contractor sites included in our review had not fully reduced energy consumption through implementation of power management settings on their desktop and laptop computers; and, as a consequence, spent $1.6 million more on energy costs than necessary in Fiscal Year 2008; (2) None of the sites reviewed had taken advantage of opportunities to reduce energy consumption, enhance cyber security, and reduce costs available through the use of techniques, such as 'thin-client computing' in their unclassified environments; and, (3) Sites had not always taken the necessary steps to reduce energy consumption and resource usage of their data centers, such as identifying and monitoring the amount of energy used at their facilities. We concluded that Headquarters programs offices (which are part of the Department of Energy's Common Operating Environment) as well as field sites had not developed and/or implemented policies and procedures necessary to ensure that information technology equipment and supporting infrastructure was operated in an energy-efficient manner and in a way that minimized impact on the environment. For example, although required by the Department, sites had not enabled computer equipment power management features designed to reduce energy consumption. In addition, officials within Headquarters programs and at the sites reviewed had not effectively monitored performance or taken steps to fully evaluate available reductions in energy usage at their facilities. Without improvements, the Department will not be able to take advantage of opportunities to reduce energy consumption and realize cost savings of nearly $23 million over the next five years at just the seven sites reviewed. We noted that the potential for reduced energy consumption at these sites alone was equivalent to the annual power requirements of over 2,400 homes or, alternatively, removing about 3,000 cars from the road each year. Many of the available energy reduction strategies, such as fully utilizing energy-efficient settings on the many computers used by the Department and its contractors, are 'low hanging fruit' in that they will provide immediate tangible energy savings at little or no cost. Others, such as a shift to thin-client computing, an environment that transfers the processing capabilities from an individual's desk to a shared server environment, will require some level of investment which can, based on available literature, be successfully recovered through reduced acquisition and support costs. In our judgment, given its highly visible leadership in energy issues, aggressive action should be taken to make the Department's information technology operations as energy efficient as possible so that it can serve as a role model for both the Federal and private sector. To its credit, the Department had increased the number of energy-efficient computers purchased in recent years. In addition, the Office of the Chief Information Officer implemented an automated computer shutdown program at Headquarters that was estimated to save up to nearly $400,000 per year. Furthermore, we found that certain sites had initiated actions to review a potential transition to unclassified thin-client computing; however, implementation had not yet been completed. These are positive steps, but additional action is required, and our report contains several recommendations to this end.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Intake and Exhaust Ducts on the Recovery Efficiency of Heat Recovery Ventilation Systems

The heat recovery efficiency of ventilation systems utilizing heat recovery ventilators (HRVs) depends not only on the heat recovery efficiency of the HRV units themselves but also on the intake and exhaust ducts that connect the HRV units to the outside environment. However, these ducts are often neglected in heat loss calculations, as their impact on the overall heat recovery efficiency of HRV systems is often not understood and, to the knowledge of the authors, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for these ducts has not been published. In this research, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for the intake and exhaust ducts was derived and validated using real-life data. The model-predicted decrease in heat recovery efficiency due to the ducts was in reasonable agreement (relative error within 20%) with the real-life measurements. The results suggest that utilizing this model allows for more correct ventilation heat loss calculations compared to using the heat recovery efficiency of the HRV unit alone, but more field studies are needed to verify the accuracy of this model in a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating the Drivers of the Cost of Saved Electricity in Utility Customer-Funded Energy Efficiency Programs

Energy efficiency programs funded by utility customers provide an electricity resource in most U.S. states, but their scale and cost of saving electricity varies significantly by state. In this paper, we explore the drivers of the cost of saved electricity in these programs with an econometric model and nearly a decade of data reported by efficiency program administrators. We found strong evidence for economies of scale and weak evidence for diseconomies of scale, which suggests that states with low levels of efficiency savings relative to retail sales can increase the size of their efficiency programs without large increases to the cost of saved electricity. We discuss examples of energy efficiency forecasting and potential modeling in light our econometric analysis and identify methodological improvements relevant to utilities and grid operators. This paper provides insights into the economics of customer-funded efficiency programs that will support regulators, utilities, and policymakers to utilize energy efficiency as a resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

"Efficiency Space" - A Framework for Evaluating Joint Evaporation and Runoff Behavior

At the land surface, higher soil moisture levels generally lead to both increased evaporation for a given amount of incoming radiation (increased evaporation efficiency) and increased runoff for a given amount of precipitation (increased runoff efficiency). Evaporation efficiency and runoff efficiency can thus be said to vary with each other, motivating the development of a unique hydroclimatic analysis framework. Using a simple water balance model fitted, in different experiments, with a wide variety of functional forms for evaporation and runoff efficiency, we transform net radiation and precipitation fields into fields of streamflow that can be directly evaluated against observations. The optimal combination of the functional forms the combination that produces the most skillful stream-flow simulations provides an indication for how evaporation and runoff efficiencies vary with each other in nature, a relationship that can be said to define the overall character of land surface hydrological processes, at least to first order. The inferred optimal relationship is represented herein as a curve in efficiency space and should be valuable for the evaluation and development of GCM-based land surface models, which by this measure are often found to be suboptimal.

GCM↗

Raising the Efficiency Ceiling with Multijunction III-V Concentrator Photovoltaics

In this paper, we look at the question 'how high can solar cell efficiency go?' from both theoretical and experimental perspectives. First-principle efficiency limits are analyzed for some of the main candidates for high-efficiency multijunction terrestrial concentrator cells. Many of these cell designs use lattice-mismatched, or metamorphic semiconductor materials in order to tune subcell band gaps to the solar spectrum. Minority-carrier recombination at dislocations is characterized in GaInAs inverted metamorphic solar cells, with band gap ranging from 1.4 to 0.84 eV, by light I-V, electron-beam-induced current (EBIC), and cathodoluminescence (CL). Metamorphic solar cells with a 3-junction GaInP/ GaInAs/ Ge structure were the first cells to reach over 40% efficiency, with an independently confirmed efficiency of 40.7% (AM1.5D, low-AOD, 240 suns, 25 C). The high efficiency of present III-V multijunction cells now in high-volume production, and still higher efficiencies of next-generation cells, is strongly leveraging for low-cost terrestrial concentrator PV systems.

14 SOLAR ENERGY↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Efficiency improved by acid texturization for multi-crystalline silicon solar cells

In this paper, we will show that efficiency of multi-crystalline silicon (mc-Si) solar cells may be improved by acid texturization. In order to enhance overall efficiency of mc-Si for solar-cell applications, the surface treatment of texturization with wet etching using appropriate solutions can improve incident light into the cell. Alkali etchant cannot produce uniformly textured surface to generate enough open circuit voltage (V{sub OC}) and high efficiency of the mc-Si due to the unavoidable grain randomly oriented with higher steps formed during etching process. Optimized acid etching conditions can be obtained by decreasing the reflectance (R) for mc-Si substrate below levels generated by alkali etching. Short-circuit current (I{sub SC}) measurements on acid textured cells reveal that current gain can be significantly enhanced by reducing reflection. The optimal acid etching ratio HF:HNO{sub 3}:H{sub 2}O = 15:1:2.5 with etching time of 60 s and lowering 42.7% of the R value can improve 112.4% of the conversion efficiency ({eta}) of the developed solar cell. In order to obtain more detailed information of different defect region, high-resolution light beam induced current (LBIC) is applied to measure the internal quantum efficiency (IQE) and the lifetime of minority carriers. Thus, the acid texturing approach is instrumental to achieve high efficiency in mass production using relatively low-cost mc-Si as starting material with proper optimization of the fabrication steps. (author)

14 SOLAR ENERGY↗

Metrics and Benchmarks for Energy Efficiency in Laboratories

A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency in their facilities. For example, the Energy Policy Act of 2005 (EPACT 2005) requires all new federal buildings to exceed ASHRAE 90.1-2004 1 by at least 30 percent. The University of California Regents Policy requires all new construction to exceed California Title 24 2 by at least 20 percent. A new laboratory is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified in programming documents and tracked during the course of the delivery process. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into the programming of new laboratory facilities. Many of these metrics can also be applied to evaluate existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to Labs21 resources, including technology best practice guides, case studies, and the design guide (available at www.labs21century.gov/toolkit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental investigation of the effect of pore size distribution on nano-particle capture efficiency within ceramic particulate filters

The effect of the pore size distribution on size-resolved filtration efficiency was investigated for two ceramic particulate filters using particulate matter (PM) generated by a spark-ignition direct-injection engine fueled with gasoline. The cordierite filter tested had a porosity of 43%, a median pore diameter (d_50) of 12 µm, and a wide pore size distribution with a lognormal standard deviation (s’) of 0.3. The aluminum titanate filter had very similar porosity, d_50, and thickness, but significantly narrower pore size distribution (s’ = 0.1). The testing of two filters under identical experimental conditions enabled the impact of the pore size distribution on filtration performance to be evaluated. Filtration experiments were performed focusing on just the filter wall, starting from a clean filter until the transition to cake filtration (filtration efficiency > 99%). Time-resolved particle size distribution measurements were used to evaluate the progression of filtration performance and estimate trapped mass within the filter. The aluminum titanate filter, with a narrow pore size distribution, exhibited significantly better diffusion capture efficiency. The negative impact of higher flow velocity on diffusion capture efficiency was more pronounced for a narrower pore size distribution. Flow distributions measured using capillary-flow porometry were used to develop a cylindrical pore flow model to understand the impact of the differences in pore size distribution on observed trends in diffusion capture efficiency within a clean filter. The model helps demonstrate how large pores on the high end of a wider pore size distribution can carry a large fraction of the flow, with less efficient capture of small particles by diffusion. The experimental results and data demonstrate that the bubble point diameter and width of the pore size distribution significantly influence diffusion capture efficiencies for filters with very similar median pore diameter, porosity, and thickness.

aerosol filtration, Aftertreatment, ceramic exhaus↗

Energy efficiency in industrial drying: A hybrid ultrasonic system with a novel dynamic optimization framework

Drying processes are among the most energy-consuming operations in industrial and manufacturing settings, demanding strategic selection, design, and control for enhanced efficiency. Advancing drying technologies is critical for improving sustainability, lowering energy use, reducing carbon emissions, and minimizing waste. This study explores two innovative strategies aimed at transforming drying processes into sustainable, low-carbon systems by reducing energy consumption, minimizing waste, and maintaining a strong emphasis on preserving product quality. The first strategy showcases a sub-pilot scale hybrid ultrasonic-convective dryer for agrifood products. This technology, powered by electricity (process electrification), integrates non-thermal ultrasonic dehydration with convective heating and is presented as a sustainable and energy-efficient solution that enhances eco-friendly practices. The second strategy involves introducing and implementing a novel, multiobjective, mixed integer dynamic optimization technique to determine the optimal time-dependent process parameter values for the drying operation. This optimization technique yields operating conditions that are piecewise constant in time aiming to maximize the energy efficiency of the hybrid ultrasonic-convective dryer while ensuring strict adherence to product quality constraints. By adopting the hybrid ultrasonic-convective dryer, a notable 35% improvement in energy efficiency was achieved compared to conventional hot-air drying systems for drying apple slices. The proposed optimization framework further enhanced energy efficiency by nearly 14% over the most efficient process on the identical testbed, under static operating conditions. The reported enhancements have been experimentally validated. Regarding drying time (thereby improving production yield), the developed hybrid ultrasonic-convective dryer demonstrates as much as a 41% reduction in total processing time, which is further optimized by an additional 10% using our proposed optimization framework. The research outcomes have profound implications for the design and operation of drying systems, encompassing crucial aspects such as process electrification, cost-effectiveness, energy savings, time efficiency, product yield, product quality, and process automation.

Dynamic optimization↗

Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks

The emergence of a pandemic affecting the respiratory system can result in a significant demand for face masks. This includes the use of cloth masks by large sections of the public, as can be seen during the current global spread of COVID-19. However, there is limited knowledge available on the performance of various commonly available fabrics used in cloth masks. Importantly, there is a need to evaluate filtration efficiencies as a function of aerosol particulate sizes in the 10 nm – 10 µm range, which is particularly relevant for respiratory virus transmission. We have carried out these studies for several common fabrics including cotton, silk, chiffon, flannel, various synthetics, and their combinations. While the filtration efficiencies for various fabrics when a single layer was used ranged from 5-80% and 15-95% for particle sizes <300 nm and >300 nm respectively, the efficiencies improved when multiple layers were used, and when using a specific combination of different fabrics. Filtration efficiencies of the hybrids (such as cotton-silk, cotton-chiffon, cotton-flannel) was >80 % (for particles <300 nm) and >90 % (for particles >300 nm). We speculate that the enhanced performance of the hybrids is likely due to the combined effect of mechanical and electrostatic-based filtration. Cotton, the most widely used material for cloth masks performs better at higher weave densities (i.e., threads per inch) and can make a significant difference in filtration efficiencies. Our studies also imply that gaps (as caused by an improper fit of the mask) can result in over a 60% decrease in the filtration efficiency, implying the need for future cloth mask design studies to take into account issues of “fit” and leakage, while allowing the exhaled air to vent efficiently. Overall, we find that combinations of various commonly available fabrics used in cloth masks can potentially provide significant protection against the transmission of aerosol particles.

36 MATERIALS SCIENCE↗