Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Microbial sensor variation across biogeochemical conditions in the terrestrial deep subsurface

ABSTRACT Microbes can be found in abundance many kilometers underground. While microbial metabolic capabilities have been examined across different geochemical settings, it remains unclear how changes in subsurface niches affect microbial needs to sense and respond to their environment. To address this question, we examined how microbial extracellular sensor systems vary with environmental conditions across metagenomes at different Deep Mine Microbial Observatory (DeMMO) subsurface sites. Because two-component systems (TCSs) directly sense extracellular conditions and convert this information into intracellular biochemical responses, we expected that this sensor family would vary across isolated oligotrophic subterranean environments that differ in abiotic and biotic conditions. TCSs were found at all six subsurface sites, the service water control, and the surface site, with an average of 0.88 sensor histidine kinases (HKs) per 100 genes across all sites. Abundance was greater in subsurface fracture fluids compared with surface-derived fluids, and candidate phyla radiation (CPR) bacteria presented the lowest HK frequencies. Measures of microbial diversity, such as the Shannon diversity index, revealed that HK abundance is inversely correlated with microbial diversity ( r 2 = 0.81). Among the geochemical parameters measured, HK frequency correlated most strongly with variance in dissolved organic carbon ( r 2 = 0.82). Taken together, these results implicate the abiotic and biotic properties of an ecological niche as drivers of sensor needs, and they suggest that microbes in environments with large fluctuations in organic nutrients (e.g., lacustrine, terrestrial, and coastal ecosystems) may require greater TCS diversity than ecosystems with low nutrients (e.g., open ocean). IMPORTANCE The ability to detect extracellular environmental conditions is a fundamental property of all life forms. Because microbial two-component sensor systems convert information about extracellular conditions into biochemical information that controls their behaviors, we evaluated how two-component sensor systems evolved within the deep Earth across multiple sites where abiotic and biotic properties vary. We show that these sensor systems remain abundant in microbial consortia at all subterranean sampling sites and observe correlations between sensor system abundances and abiotic (dissolved organic carbon variation) and biotic (consortia diversity) properties. These results suggest that multiple environmental properties may drive sensor protein evolution and highlight the need for further studies of metagenomic and geochemical data in parallel to understand the drivers of microbial sensor evolution.

response regulator↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

Low‐Field Borehole NMR Applications in the Near‐Surface Environment

Core Ideas Low‐field borehole NMR characterizes subsurface heterogeneities from pore to macro scales. Borehole NMR is sensitive to biogeochemical processes and conversions in the subsurface. Development of borehole NMR benefits hydrogeology, soil management, and engineering. The inherent heterogeneity of the near subsurface (<200 m below the ground surface) presents challenges for agricultural water management, hydrogeologic characterization, and engineering, among other fields. Borehole nuclear magnetic resonance (NMR) has the potential not only to describe this heterogeneity in space nondestructively but also to monitor physical and chemical changes in the subsurface with time. Nuclear magnetic resonance is sensitive to parameters of interest like porosity and permeability, saturation, fluid viscosity, and formation mineralogy. Borehole NMR tools have been used to measure soil moisture in model soils, and recent advances in low‐field borehole NMR instrumentation allow estimation of hydraulic properties of unconsolidated aquifers. We also demonstrate the potential for low‐field borehole NMR tools to monitor field‐relevant biogeochemical processes like biofilm accumulation and microbially induced calcite precipitation at laboratory and field scales. Finally, we address some remaining challenges and areas of future research, as well as other possible applications where borehole NMR could provide valuable complementary data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties Important to Mixing for WTP Large Scale Integrated Testing

Large Scale Integrated Testing (LSIT) is being planned by Bechtel National, Inc. to address uncertainties in the full scale mixing performance of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. External review boards have raised questions regarding the overall representativeness of simulants used in previous mixing tests. Accordingly, WTP requested the Savannah River National Laboratory (SRNL) to assist with development of simulants for use in LSIT. Among the first tasks assigned to SRNL was to develop a list of waste properties that matter to pulse-jet mixer (PJM) mixing of WTP tanks. This report satisfies Commitment 5.2.3.1 of the Department of Energy Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 2010-2: physical properties important to mixing and scaling. In support of waste simulant development, the following two objectives are the focus of this report: (1) Assess physical and chemical properties important to the testing and development of mixing scaling relationships; (2) Identify the governing properties and associated ranges for LSIT to achieve the Newtonian and non-Newtonian test objectives. This includes the properties to support testing of sampling and heel management systems. The test objectives for LSIT relate to transfer and pump out of solid particles, prototypic integrated operations, sparger operation, PJM controllability, vessel level/density measurement accuracy, sampling, heel management, PJM restart, design and safety margin, Computational Fluid Dynamics (CFD) Verification and Validation (V and V) and comparison, performance testing and scaling, and high temperature operation. The slurry properties that are most important to Performance Testing and Scaling depend on the test objective and rheological classification of the slurry (i.e., Newtonian or non-Newtonian). The most important properties for testing with Newtonian slurries are the Archimedes number distribution and the particle concentration. For some test objectives, the shear strength is important. In the testing to collect data for CFD V and V and CFD comparison, the liquid density and liquid viscosity are important. In the high temperature testing, the liquid density and liquid viscosity are important. The Archimedes number distribution combines effects of particle size distribution, solid-liquid density difference, and kinematic viscosity. The most important properties for testing with non-Newtonian slurries are the slurry yield stress, the slurry consistency, and the shear strength. The solid-liquid density difference and the particle size are also important. It is also important to match multiple properties within the same simulant to achieve behavior representative of the waste. Other properties such as particle shape, concentration, surface charge, and size distribution breadth, as well as slurry cohesiveness and adhesiveness, liquid pH and ionic strength also influence the simulant properties either directly or through other physical properties such as yield stress.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Deep Subsurface Resistivity Imaging for Hydrofracture Monitoring

This report describes the results of the first of its kind monitoring of a hydrofracture operation with electromagnetic measurements. The researchers teamed with oil and gas producer Encana Corporation to design and execute a borehole to surface monitoring of three fracture stages at a well pad in central Colorado. The field project consisted of an equipment upgrade, a survey design and modeling phase, several weeks of data collection, and data processing and interpretation. Existing Depth to Surface Resistivity (DSR) instrumentation was upgraded to allow for continuous high precision recording from downhole sources. The full system can now collect data continuously for up to 72 hours, which is sufficient to measure data for 10 frac stages. Next we used numerical modeling and frac treatment data supplied by Encana to design a field survey to detect EM signal from induced fractures. Prior to modeling we developed a novel technique for using well casing as an antenna for a downhole source. Modeling shows that 1) a measurable response for an induced fracture could be achieved if the facture fluid was of high salinity 2) an optimum fracture response is created when the primary source field is parallel to the well casing but perpendicular to the fracture direction. In mid-July, 2014 we installed an array of more than 100 surface sensors, distributed above the treatment wells and extending for approximately 1 km north and 750 m eastward. We applied a 0.6 Hz square wave signal to a downhole current electrode located in a horizontal well 200 m offset from the treatment well with a return electrode on the surface. The data were transmitted to a recording trailer via Wi-Fi where we monitored receiver and transmitter channels continuously in a 72-hour period which covered 7 frac stages, three of which were high salinity. Although the background conditions were very noisy we were able to extract a clear signal from the high salinity stages. Initial data interpretation attempts consisting of trying to directly invert collected data using a simple background starting model did not produce reasonable models. We next used a simulated data set to develop a constrained inversion workflow that places the downhole fracture in the correct location. Finally, we used a combination of forward and inverse models to fit the collected data to a model that incorporated 3 frac stages. This project provided a first-of-its-kind application of EM technology to map an induced fracture. The results demonstrated a clear anomaly during the operation that can be fit to a reasonable model of an induced fracture.

42 ENGINEERING↗

Improve Fuel Economy through Formulation Design and Modeling

The target of performance level of this project is overall FE >2% when a combination of Valvoline’s engine oil, axle oil and transmission fluid are applied to a medium duty Class-6 truck, which was measured by the SAE J1321 vehicle level fuel consumption test. The statistical analysis of test results showed that all four combinations of Valvoline’s five candidate oils have this potential at the 95% confidence.

02 PETROLEUM↗

Pore architecture controls on mineral reactivity

Mineral dissolution rates measured in natural environments are much slower than those measured in laboratory settings. This project tested the hypothesis that the way fluid flows through rocks in natural systems creates areas where mineral dissolution is fast and areas where mineral dissolution is slow. This hypothesis was tested with a combination of laboratory experiments and numerical simulation. We demonstrated a separation of fluid flow pathways and rates of mineral dissolution in laboratory experiments for the first time using an experimental approach where we created synthetic rocks that have different ratios of connected and dead-end pathways for fluid flow. In laboratory experiments with higher proportions of dead-end pathways, the mineral dissolution rates were slower. We found that where fluid flows through connected pathways the continuous refreshing of fluid at the mineral surface creates conditions where dissolution is fast. In contrast, where fluid either flows slowly through poorly connected pathways or is stagnant in dead-end pathways, mineral dissolution is slow. The results from this project suggest that the overall slowing of rates of mineral dissolution is important when the proportion of dead-end pathways is greater than ~40%. This project informs our understanding of the way that fluids react with rocks in carbon dioxide sequestration and enhanced geothermal projects where fluids are purposefully injected into rocks for energy applications.

58 GEOSCIENCES↗

Multiscale Assessment of Caprock Integrity for Geologic Carbon Storage in the Pennsylvanian Farnsworth Unit, Texas, USA

Leakage pathways through caprock lithologies for underground storage of CO2 and/or enhanced oil recovery (EOR) include intrusion into nano-pore mudstones, flow within fractures and faults, and larger-scale sedimentary heterogeneity (e.g., stacked channel deposits). To assess multiscale sealing integrity of the caprock system that overlies the Morrow B sandstone reservoir, Farnsworth Unit (FWU), Texas, USA, we combine pore-to-core observations, laboratory testing, well logging results, and noble gas analysis. A cluster analysis combining gamma ray, compressional slowness, and other logs was combined with caliper responses and triaxial rock mechanics testing to define eleven lithologic classes across the upper Morrow shale and Thirteen Finger limestone caprock units, with estimations of dynamic elastic moduli and fracture breakdown pressures (minimum horizontal stress gradients) for each class. Mercury porosimetry determinations of CO2 column heights in sealing formations yield values exceeding reservoir height. Noble gas profiles provide a “geologic time-integrated” assessment of fluid flow across the reservoir-caprock system, with Morrow B reservoir measurements consistent with decades-long EOR water-flooding, and upper Morrow shale and lower Thirteen Finger limestone values being consistent with long-term geohydrologic isolation. Together, these data suggest an excellent sealing capacity for the FWU and provide limits for injection pressure increases accompanying carbon storage activities.

58 GEOSCIENCES↗

On the consistency of scale among experiments, theory, and simulation

As a tool for addressing problems of scale, we consider an evolving approach known as the thermodynamically constrained averaging theory (TCAT), which has broad applicability to hydrology. We consider the case of modeling of two-fluid-phase flow in porous media, and we focus on issues of scale as they relate to various measures of pressure, capillary pressure, and state equations needed to produce solvable models. We apply TCAT to perform physics-based data assimilation to understand how the internal behavior influences the macroscale state of two-fluid porous medium systems. A microfluidic experimental method and a lattice Boltzmann simulation method are used to examine a key deficiency associated with standard approaches. In a hydrologic process such as evaporation, the water content will ultimately be reduced below the irreducible wetting-phase saturation determined from experiments. This is problematic since the derived closure relationships cannot predict the associated capillary pressures for these states. We demonstrate that the irreducible wetting-phase saturation is an artifact of the experimental design, caused by the fact that the boundary pressure difference does not approximate the true capillary pressure. Using averaging methods, we compute the true capillary pressure for fluid configurations at and below the irreducible wetting-phase saturation. Results of our analysis include a state function for the capillary pressure expressed as a function of fluid saturation and interfacial area.

13 HYDRO ENERGY↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Aerosol Formation from High-Pressure Sprays for Supporting the Safety Analysis for the Hanford Waste Treatment and Immobilization Plant

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pretreat and vitrify waste currently stored in underground tanks at Hanford. One of the postulated events in the hazard analysis for the WTP is a breach in process piping that produces a pressurized spray with small droplets that can be transported into ventilation systems. Literature correlations are currently used for estimating the generation rate and size distribution of aerosol droplets in postulated spray releases. These correlations, however, are based on results obtained from small engineered nozzles using Newtonian liquids that do not contain slurry particles and thus do not accurately represent the fluids and breaches in the WTP. A test program was developed to measure the generation rate of droplets suspended in a test chamber and droplet size distribution from a range of prototypic sprays. A novel test method was developed to allow measurement of sprays from small to very large breaches and also includes the effect of aerosol generation from splatter when the spray impacts on walls. Results show that the aerosol generation rate increases with increasing the orifice area, though with a weaker dependence on orifice area than the currently-used correlation. A comparison of water sprays to slurry sprays with 8 to 20 wt% gibbsite or boehmite particles shows that the presence of slurry particles depresses the release fraction compared to water for droplets above 10 μm and increases the release fraction below this droplet size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Self-contained, automated, long-term sensor system for monitoring of soil and water nutrients in fields

An automated, fieldable ion-selective sensor system for frequent detection of nutrients in soils or water is set forth. In one aspect, an integrated small form-factor housing includes a battery, processor, a fluid manipulation unit and reservoirs, and a chemical species detection cell. A flow-through sampling head can be connected to the detection cell and a waste reservoir by flexible tubing sealingly connected at opposite ends of the tube. In one aspect, improved performance of the ion-selective sensor includes adding an ion-to-electron transfer interlayer between an ion-selective membrane and its working electrode. In one aspect, the sensor is solid-state and uses printed polymeric composite of POT-MoS$_{2}$. The use of a porous tube for a sampling head and fluid connection at opposite ends allows not only fluid to be removed from the head to the detection cell for measurement but also flow in an opposite direction and out to a waste reservoir to clean and reset for a next sample measurement.

60 APPLIED LIFE SCIENCES↗

Aerosol Formation from High-Pressure Sprays for Supporting the Safety Analysis for the Hanford Waste Treatment and Immobilization Plant - 13183

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pretreat and vitrify waste currently stored in underground tanks at Hanford. One of the postulated events in the hazard analysis for the WTP is a breach in process piping that produces a pressurized spray with small droplets that can be transported into ventilation systems. Literature correlations are currently used for estimating the generation rate and size distribution of aerosol droplets in postulated releases. These correlations, however, are based on results obtained from small engineered nozzles using Newtonian liquids that do not contain slurry particles and thus do not represent the fluids and breaches in the WTP. A test program was developed to measure the generation rate, and the release fraction which is the ratio of generation rate to spray flow rate, of droplets suspended in a test chamber and droplet size distribution from prototypic sprays. A novel test method was developed to allow measurement of sprays from small to large breaches and also includes the effect of aerosol generation from splatter when the spray impacts on walls. Results show that the release fraction decreases with increasing orifice area, though with a weaker dependence on orifice area than the currently-used correlation. A comparison of water sprays to slurry sprays with 8 to 20 wt% gibbsite or boehmite particles shows that the presence of slurry particles depresses the release fraction compared to water for droplets above 10 μm and increases the release fraction below this droplet size. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The roles of the binodal curve and the spinodal curve in expansions from the supercritical state with flashing

Data extracted from time-of-flight (TOF) measurements made on steady-state He free jets at Göttingen already in 1986 and for pulsed Ne free jets investigated recently at Tel Aviv have been added to an earlier plot of terminal condensed-phase mass fraction x{sub 2∞} as a function of the dimensionless scaling parameter Γ. Γ characterizes the source (fluid species, temperature, pressure and throat diameter); values of x{sub 2∞} are extracted from TOF measurements using conservation of energy in the free-jet expansion. For nozzles consisting of an orifice in a thin plate; the extracted data yield 22 data points which are correlated satisfactorily by a single curve. The Ne free jets were expanded from a conical nozzle with a 20° half angle; the three extracted data points stand together but apart from the aforementioned curve, indicating that the presence of the conical wall influences significantly the expansion and hence the condensation. The 22 data points for the expansions via an orifice consist of 15 measurements with expansions from the gas-phase side of the binodal curve which crossed the binodal curve downstream from the sonic point and 7 measurements with expansions of the gas-phase product of the flashing which occurred after an expansion from the liquid-phase side of the binodal curve crossed the binodal curve upstream from the sonic point. The association of these 22 points with a single curve supports the alternating-phase model for flows with flashing upstream from the sonic point proposed earlier. In order to assess the role of the spinodal curve in such expansions, the spinodal curves for He and Ne were computed using general multi-parameter Helmholtz-free-energy equation-of-state formulations. Then, for the several sets of source-chamber conditions used in the free-jet measurements, thermodynamic states at key locations in the free-jet expansions (binodal curve, sonic point and spinodal curve) were evaluated, with the expansion presumed to be metastable from the binodal curve to the spinodal curve. TOF distributions with more than two peaks (interpreted earlier as superimposed alternating-state TOF distributions) indicated flashing of the metastable flow downstream from the binodal curve but upstream from the sonic point. This relatively early flashing is due apparently to destabilizing interactions with the walls of the source. If the expansion crosses the binodal curve downstream from the nozzle, the metastable fluid does not interact with surfaces and flashing might be delayed until the expansion reaches the spinodal curve. It is concluded that, if the expansion crosses the binodal curve before reaching the sonic point, the resulting metastable fluid downstream from the binodal curve interacts with the adjacent surfaces and flashes into liquid and vapor phases which expand alternately through the nozzle; the two associated alternating TOF distributions are superposed by the chopping process so that the result has the appearance of a single distribution with three peaks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Argonne Bubble Experiment Thermal Model Development II

This report describes the continuation of the work reported in “Argonne Bubble Experiment Thermal Model Development”. The experiment was performed at Argonne National Laboratory (ANL) in 2014. A rastered 35 MeV electron beam deposited power in a solution of uranyl sulfate, generating heat and radiolytic gas bubbles. Irradiations were performed at three beam power levels, 6, 12 and 15 kW. Solution temperatures were measured by thermocouples, and gas bubble behavior was observed. This report will describe the Computational Fluid Dynamics (CFD) model that was developed to calculate the temperatures and gas volume fractions in the solution vessel during the irradiations. The previous report described an initial analysis performed on a geometry that had not been updated to reflect the as-built solution vessel. Here, the as-built geometry is used. Monte-Carlo N-Particle (MCNP) calculations were performed on the updated geometry, and these results were used to define the power deposition profile for the CFD analyses, which were performed using Fluent, Ver. 16.2. CFD analyses were performed for the 12 and 15 kW irradiations, and further improvements to the model were incorporated, including the consideration of power deposition in nearby vessel components, gas mixture composition, and bubble size distribution. The temperature results of the CFD calculations are compared to experimental measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗