Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

PULSED GAMMA-RAYS FROM PSR J2021+3651 WITH THE FERMI LARGE AREA TELESCOPE

We report the detection of pulsed gamma-rays from the young, spin-powered radio pulsar PSR J2021+3651 using data acquired with the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope (formerly GLAST). The light curve consists of two narrow peaks of similar amplitude separated by 0.468 {+-} 0.002 in phase. The first peak lags the maximum of the 2 GHz radio pulse by 0.162 {+-} 0.004 {+-} 0.01 in phase. The integral gamma-ray photon flux above 100 MeV is (56 {+-} 3 {+-} 11) x 10{sup -8} cm{sup -2} s{sup -1}. The photon spectrum is well described by an exponentially cut-off power law of the form dF/dE=kE{sup -{gamma}}e{sup (-E/E{sub c})}, where the energy E is expressed in GeV. The photon index is {gamma} = 1.5 {+-} 0.1 {+-} 0.1 and the exponential cut-off is E{sub c} = 2.4 {+-} 0.3 {+-} 0.5 GeV. The first uncertainty is statistical and the second is systematic. The integral photon flux of the bridge is approximately 10% of the pulsed emission, and the upper limit on off-pulse gamma-ray emission from a putative pulsar wind nebula is < 10% of the pulsed emission at the 95% confidence level. Radio polarization measurements yield a rotation measure of RM = 524 {+-} 4 rad m{sup -2} but a poorly constrained magnetic geometry. Re-analysis of Chandra X-ray Observatory data enhanced the significance of the weak X-ray pulsations, and the first peak is roughly phase aligned with the first gamma-ray peak. We discuss the emission region and beaming geometry based on the shape and spectrum of the gamma-ray light curve combined with radio and X-ray measurements, and the implications for the pulsar distance. Gamma-ray emission from the polar cap region seems unlikely for this pulsar.

99 GENERAL AND MISCELLANEOUS↗

SIMILARITY OF THE OPTICAL-INFRARED AND {gamma}-RAY TIME VARIABILITY OF FERMI BLAZARS

We present the time variability properties of a sample of six blazars, AO 0235+164, 3C 273, 3C 279, PKS 1510-089, PKS 2155-304, and 3C 454.3, at optical-IR frequencies as well as {gamma}-ray energies. These observations were carried out as a part of the Yale/SMARTS program during 2008-2010 that has followed the variations in emission of the bright Fermi Large Area Telescope monitored blazars in the southern sky with closely spaced observations at BVRJK bands. We find that the optical-near IR variability properties are remarkably similar to those at the {gamma}-ray energies. The discrete auto-correlation functions of the variability of these six blazars at optical-IR and {gamma}-ray energies do not show any periodicity or characteristic timescale. The power spectral density (PSD) functions of the R-band variability of all six blazars are fit well by simple power-law functions with negative slopes such that there is higher amplitude variability on longer timescales. No clear break is identified in the PSD of any of the sources. The average slope of the PSD of R-band variability of these blazars is similar to what was found by the Fermi team for the {gamma}-ray variability of a larger sample of bright blazars. This is consistent with leptonic models where the optical-IR and {gamma}-ray emission is generated by the same population of electrons through synchrotron and inverse Compton processes, respectively. The prominent flares present in the optical-IR as well as the {gamma}-ray light curves of these blazars are predominantly symmetric, i.e., have similar rise and decay timescales, indicating that the long-term variability is dominated by the crossing time of radiation or a disturbance through the emission region rather than by the acceleration or energy-loss timescales of the radiating electrons. For the blazar 3C 454.3, which has the highest-quality light curves, the total energy output, the ratio of {gamma}-ray to optical energy output, and the {gamma}-ray versus optical flux relation differ in the six individual flares observed between 2009 August and December. The results are consistent with the location of a large {gamma}-ray outburst in 3C 454.3 during 2009 December being in the jet at {approx}18 pc from the central engine. This poses strong constraints on the models of high-energy emission in the jets of blazars.

79 ASTRONOMY AND ASTROPHYSICS↗

The diffuse gamma-ray flux associated with sub-PEV/PEV neutrinos from starburst galaxies

One attractive scenario for the excess of sub-PeV/PeV neutrinos recently reported by IceCube is that they are produced by cosmic rays in starburst galaxies colliding with the dense interstellar medium. These proton-proton (pp) collisions also produce high-energy gamma rays, which finally contribute to the diffuse high-energy gamma-ray background. We calculate the diffuse gamma-ray flux with a semi-analytic approach and consider that the very high energy gamma rays will be absorbed in the galaxies and converted into electron-positron pairs, which then lose almost all of their energy through synchrotron radiation in the strong magnetic fields in the starburst region. Since the synchrotron emission goes into energies below GeV, this synchrotron loss reduces the diffuse high-energy gamma-ray flux by a factor of about two, thus leaving more room for other sources to contribute to the gamma-ray background. For an E{sub ν}{sup −2} neutrino spectrum, we find that the diffuse gamma-ray flux contributes about 20% of the observed diffuse gamma-ray background in the 100 GeV range. However, for a steeper neutrino spectrum, this synchrotron loss effect is less important, since the energy fraction in absorbed gamma rays becomes lower.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear structure study of semi-magic {sup 125}Sn via (n,{gamma}) and (d,p) reactions

The nuclear structure of the semi-magic isotope {sup 125}Sn was investigated by means of the {sup 124}Sn(n{sub th},{gamma}{gamma}){sup 125}Sn reaction and the {sup 124}Sn(d-vector,p){sup 125}Sn reaction. More than 400 levels, in most cases with their spin, parity, (d,p) spectroscopic factor, and {gamma} decay, were identified. About 750 {gamma} transitions from our (n,{gamma}{gamma}) experiment form the essentially complete {gamma}-decay scheme following thermal neutron capture. Using this extensive {gamma}-decay scheme the neutron binding energy was determined to be 5733.5(2) keV. The strong correlation of the (d,p) strengths and the (n,{gamma}) intensities for more than 50 levels gives evidence for the direct neutron capture process, which was studied in detail. The experimental data were compared with predictions of the quasiparticle phonon model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Irradiation tests of prototype self-powered gamma and neutron detectors

In the framework of the SCK.CEN-CEA Joint Instrumentation Laboratory, we are developing and optimizing a self-powered detector for selective in-core monitoring of the gamma field. Several prototypes with bismuth emitters were developed and tested in a pure gamma field (the PAGURE gamma irradiation facility at CEA) and in mixed neutron and gamma fields (in the OSIRIS reactor at CEA and in the BR2 reactor at SCK.CEN). Detailed MCNP modelling was performed to calculate the gamma and neutron sensitivities. Apart from a few failing prototypes, all detectors showed equilibrium signals proportional to the gamma field with a good long-term stability (under irradiation during several weeks). A tubular geometry design was finally selected as the most appropriate for in-core gamma detection, coupling a larger sensitivity with better response characteristics. In the same experiment in BR2 six prototype Self-Powered Neutron Detectors (SPNDs) with continuous sheaths (i.e. without any weld between the sensitive part and the cable) were extensively tested: two SPNDs with Co emitter, two with V emitter and two with Rh emitters, with varying geometries. All detector responses were verified to be proportional to the reactor power. The prompt and delayed response contributions were quantified. The signal contributions due to the impact of gamma rays were experimentally determined. The evolution of the signals was continuously followed during the full irradiation period. The signal-to-noise level was observed to be well below 1% in typical irradiation conditions. The absolute neutron and gamma responses for all SPNDs are consistent. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ratio method for estimating uncertainty in calculated gamma cascades

The assessment of uncertainty on deduced quantities obtained through both measurement and modeling must include contributions from both components. There are several methods to estimate the uncertainty due to modeling, such as the parametric uncertainty and that stemming from model bias. However, in the case where experimental data exists for partial cross sections, such as discrete gammas emitted in the de-excitation of the product nucleus following the reaction, the discrepancy between the measured and modeled gamma cascades provides more information and allows for uncertainty estimation that can account for all types of model and data uncertainty. This work presents a method for estimating that uncertainty, using ratios of gammas to get a measure of the accuracy of different parts of the modeled gamma cascade. The gamma with the lowest intensity uncertainty is shown to be the best for determining the channel cross section with realistic uncertainties, indicating that it should be used rather than the most intense gamma or a sum of gammas. In conclusion, this method provides both a simple procedure for calculating realistic uncertainties and identifies the best gamma for use in converting a set of measured partial gamma cross sections to the deduced total channel cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of thyroid follicular cells to gamma irradiation compared to proton irradiation. I. Initial characterization of DNA damage, micronucleus formation, apoptosis, cell survival, and cell cycle phase redistribution

The RBE of protons has been assumed to be equivalent to that of photons. The objective of this study was to determine whether radiation-induced DNA and chromosome damage, apoptosis, cell killing and cell cycling in organized epithelial cells was influenced by radiation quality. Thyroid-stimulating hormone-dependent Fischer rat thyroid cells, established as follicles, were exposed to gamma rays or proton beams delivered acutely over a range of physical doses. Gamma-irradiated cells were able to repair DNA damage relatively rapidly so that by 1 h postirradiation they had approximately 20% fewer exposed 3' ends than their counterparts that had been irradiated with proton beams. The persistence of free ends of DNA in the samples irradiated with the proton beam implies that either more initial breaks or a quantitatively different type of damage had occurred. These results were further supported by an increased frequency of chromosomal damage as measured by the presence of micronuclei. Proton-beam irradiation induced micronuclei at a rate of 2.4% per gray, which at 12 Gy translated to 40% more micronuclei than in comparable gamma-irradiated cultures. The higher rate of micronucleus formation and the presence of larger micronuclei in proton-irradiated cells was further evidence that a qualitatively more severe class of damage had been induced than was induced by gamma rays. Differences in the type of damage produced were detected in the apoptosis assay, wherein a significant lag in the induction of apoptosis occurred after gamma irradiation that did not occur with protons. The more immediate expression of apoptotic cells in the cultures irradiated with the proton beam suggests that the damage inflicted was more severe. Alternatively, the cell cycle checkpoint mechanisms required for recovery from such damage might not have been invoked. Differences based on radiation quality were also evident in the alpha components of cell survival curves (0.05 Gy(-1) for gamma rays, 0.12 Gy(-1) for protons), which suggests that the higher level of survival of gamma-irradiated cells could be attributed to the persistence of nonlethally irradiated thyrocytes and/or the capacity to repair damage more effectively than cells exposed to equal physical doses of protons. The final assessment in this study was radiation-induced cell cycle phase redistribution. Gamma rays and protons produced a similar dose-dependent redistribution toward a predominantly G(2)-phase population. From our cumulative results, it seems likely that a majority of the proton-irradiated cells would not continue to divide. In conclusion, these findings suggest that there are quantitative and qualitative differences in the biological effects of proton beams and gamma rays. These differences could be due to structured energy deposition from the tracks of primary protons and the associated high-LET secondary particles produced in the targets. The results suggest that a simple dose-equivalent approach to dosimetry may be inadequate to compare the biological responses of cells to photons and protons.

NASA Discipline Radiation Health↗

MoonBEAM: A Beyond Earth-Orbit Gamma-Ray Burst Detector for Multi-Messenger Astronomy

Moon Burst Energetics All-sky Monitor (MoonBEAM) is a CubeSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. A gamma-ray instrument in cislunar orbit will have greatly reduced sky blockage compared to instruments in low Earth orbit. Working in conjunction with another instrument in low Earth orbit, MoonBEAM can also help constrain the arrival direction of the wavefront to an annulus on the sky by utilizing the light arrival times between the different orbits. This method has been demonstrated by the Interplanetary Gamma- Ray Burst Timing Network. However, delays in data downlink for instruments outside the Tracking and Data Relay Satellite network prevent rapid follow-up observations. We present here a gamma-ray CubeSat concept in Earth-Moon L3 halo orbit that is capable of faster response and provide a timing baseline for localization improvement. Such an instrument would aid in the gravitational wave follow-up observations in other wavelengths to identify the gamma-ray burst afterglow and kilonova emission. Reducing the region of interest makes identifying afterglows much faster, allowing for rapid on-source observations and monitoring of the rise and decay times. It will also prevent source confusion between two transients and enable robust association. A gamma-ray detection could also increase the confidence of a simultaneous but marginal gravitational wave signal, extending the detection horizon. MoonBEAM is a 12U CubeSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. Such an instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of stellar life cycles and black hole formations.

gamma-ray Cubesat↗

Use of a Position-Sensitive Multi-Anode Photomultiplier Tube for Finding Gamma-Ray Source Direction

In an urban environment where gamma-ray background counts vary rapidly, it is important to determine the angle (with respect to the detector system) of a discrete gamma-ray–emitting source for localization purposes. We have recently developed a handheld gamma-ray detection system that provides gamma-ray energy spectral data and angular position of the target source. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. The objectives of this project were to design and build a prototype, light-weight, hand-held, gamma-ray spectrometer with directional sensitivity. It is important for first responders in a radiological emergency to have an easy-to-use gamma spectrometric detection system that determines the incident gamma-ray energy along with the relative angular position of a point-like radioactive source in a near-field measurement (≤3 meters from the source). The technical challenge of this project, driven by search scenarios for monitoring crowds in a national special security events was to determine the relative angle of a gamma-ray–emitting source (50 μCi strong) at a distance of 3 meters from the detector in 3 minutes. We designed and built small, portable, light-weight directional gamma energy spectrometers using a position-sensitive multi-anode photomultiplier. All of three spectrometers showed remarkable (ΔΘ = ± 2°) sensitivity to relative angular position of the source in near-field laboratory measurements.

position-sensitive photomultiplier tube (PMT), mul↗

Improved Gamma Yield and Interaction Cross-Section Libraries of MC2-3

The MC{sup 2}-3 code developed by Argonne National Laboratory (ANL) has been widely used for multigroup cross section generation for fast reactor design and analysis. The neutron cross sections generated with MC{sup 2}-3 have been validated with various fast critical experiments. The gamma production data and interaction cross sections were also verified with the EBR-II benchmark problem. The current gamma calculation process is based on the 21-group gamma libraries generated with the NJOY code, which does not include the delayed gamma production and does not account for the self-shielding effect on the KERMA (Kinetic Energy Released in Material) factor. In order to improve gamma prediction accuracy, the gamma libraries of MC{sup 2}-3 have recently been extended from 21 to 94 groups, including delayed gamma data and kinetic energy release per reaction data. The latter is used to take into account the self-shielding effect on KERMA factors. Gamma transport calculation capabilities have also been added to MC{sup 2}-3. In this paper, we present the updated data and gamma transport capabilities along with the verification tests with ABTR and EBR-II benchmark problems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Use of the portable decay gamma source feature in the R2Smesh code system for the accurate estimation of photon radiation dose fields around activated ITER components - Paper 111

The R2Smesh ('Rigorous 2-step') code system, developed by KIT for the determination of shut-down dose rate distribution on mesh grid, can be utilized to provide photon radiation dose field around activated components which are moved from the irradiation site in fusion reactor to another external location. R2Smesh couples MCNP transport calculations and FISPACT inventory calculations through suitable interfaces utilizing MCNP mesh tally capability. Neutron flux and the decay gamma source are provided with high resolution on the mesh grid superimposed to the real geometry to take into account the spatial variations of the flux and the decay gamma source distributions. This feature enables the decay gamma source distribution to be transferred from the irradiation site in the reactor to any other external location for the determination of photon flux and dose rate distributions. In this work, we applied the feature of the portable decay gamma source in R2Smesh code system to a dose rate analysis for a tunnel connecting the ITER tokamak complex building (TCB) and the hot cell facility building (HCFB). This paper presents the use of the portability feature of the decay gamma source in R2Smesh interface code system developed by KIT for a dose rate analysis of the ITER tunnel connecting TCB and HCFB. This application shows that the decay gamma source of the activated components could be transferred successfully from one coordinate system to another coordinate system and superimposed to the geometry of the components. This is very useful when the activated components need to be transported from the reactor to somewhere else for maintenance, testing or storage and the dose rate analysis is requested. Another portable feature, which could convert the 3D decay gamma source distribution generated by R2Smesh system to the MCNP 'SDEF' card source description and avoid the use of source sampling subroutine, is under consideration. With this feature, one decay gamma source result for the specific reactor components could be shared by different institutions who need to use the same decay gamma source for different analysis. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Extra-light gamma-ray imager for safeguards and homeland security

Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

42 ENGINEERING↗

Development of a Course in Gamma Ray Spectrometry

The majority of undergraduate and graduate students in nuclear science and engineering take a general course in nuclear instrumentation where one of the topics is typically in gamma ray spectrometry. Rarely are courses offered solely on this subject matter other than intensified workshops conducted by the International Atomic Energy Agency (IAEA) or private companies which can be expensive especially for large groups of students. Currently there are many world-wide projects in routine monitoring and advanced research that employ gamma rays. Some but not an exhaustive list of these topics include neutron activation analysis, naturally occurring radioactivity materials (NORM), nuclear forensics, nuclear security, in-situ gamma ray detection, galactic gamma ray detection, health physics and advanced instrumentation. At the Nuclear Engineering Teaching Laboratory at the University of Texas at Austin, many of our students are involved in an array of research topics that involve gamma ray spectrometry in their Masters of Science theses, PhD dissertations and special topics courses. It was decided to invest the time and effort to develop a course with a strong technical component to complement their research activities. A detailed stand-alone course in gamma ray spectrometry that includes a series lectures in modular form has been developed. As well we have incorporated fourteen advanced animations to better explain some of the fundamental physical processes and experimental set-ups. Six laboratory sessions and multiple homework assignments have also been established. This course is applicable to senior undergraduate students, graduate students, and novice researchers the above mentioned fields in a traditional class/laboratory setting or for intense one to two week workshops. A great deal of effort was undertaken to prepare a stand-alone course in gamma ray spectrometry which includes many of the fundamental aspects as well as the more advanced instrumentation. Animations of gamma ray interactions and experimental set ups were also developed. Six laboratories and six assignments were also conceived. Every topic has its own module thus a 'pick and choose' subset of lectures can be given to different levels of understanding. This course is applicable to senior undergraduate students, graduate students, novice researchers in neutron activation analysis and naturally occurring radioactive material, and for intense one to two week workshops. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sphingosine kinase inhibitor suppresses IL-18-induced interferon-gamma production through inhibition of p38 MAPK activation in human NK cells

Natural killer (NK) cells play an important role in the innate immune response. Interleukin-18 (IL-18) is a well-known interferon-gamma (IFN-{gamma} inducing factor, which stimulates immune response in NK and T cells. Sphingosine kinase (SPHK) catalyzes the formation of sphingosine 1-phosphate (S1P), which acts as a second messenger to function as an anti-apoptotic factor and proliferation stimulator of immune cells. In this study, to elucidate whether SPHK is involved in IL-18-induced IFN-{gamma} production, we measured IL-18-induced IFN-{gamma} production after pre-treatment with SPHK inhibitor (SKI) in NK-92MI cells. We found that IL-18-induced IFN-{gamma} expression was blocked by SKI pre-treatment in both mRNA and protein levels. In addition, the increased IFN-{gamma} production by stimulation with IL-18 is mediated through both SPHK and p38 MAPK. To determine the upstream signals of SKI and p38 MAPK in IL-18-induced IFN-{gamma} production, phosphorylation levels of p38 MAPK was measured after SKI pre-treatment. As a result, inhibition of SPHK by SKI blocked phosphorylation of p38 MAPK, showing that SPHK activation by IL-18 is an upstream signal of p38 MAPK activation. Inhibition of SPHK by SKI also inhibited IL-18-induced IFN-{gamma} production in human primary NK cells. In conclusion, SPHK activation is an essential factor for IL-18-induced IFN-{gamma} production via p38 MAPK.

60 APPLIED LIFE SCIENCES↗

PPAR{gamma} ligands induce growth inhibition and apoptosis through p63 and p73 in human ovarian cancer cells

Research highlights: {yields} PPAR{gamma} ligands increased the rate of apoptosis and inhibition of proliferation in ovarian cancer cells. {yields} PPAR{gamma} ligands induced p63 and p73 expression, but not p53. {yields} p63 and p73 leads to an increase in p21 expression and apoptosis in ovarian cancer cells with treatment PPAR{gamma} ligands. {yields} These findings suggest that PPAR{gamma} ligands suppressed growth of ovarian cancer cells through upregulation of p63 and p73. -- Abstract: Peroxisome proliferator-activated receptor gamma (PPAR{gamma}) agonists, including thiazolidinediones (TZDs), can induce anti-proliferation, differentiation, and apoptosis in various cancer cell types. This study investigated the mechanism of the anticancer effect of TZDs on human ovarian cancer. Six human ovarian cancer cell lines (NIH:OVCAR3, SKOV3, SNU-251, SNU-8, SNU-840, and 2774) were treated with the TZD, which induced dose-dependent inhibition of cell growth. Additionally, these cell lines exhibited various expression levels of PPAR{gamma} protein as revealed by Western blotting. Flow cytometry showed that the cell cycle was arrested at the G1 phase, as demonstrated by the appearance of a sub-G1 peak. This observation was corroborated by the finding of increased levels of Bax, p21, PARP, and cleaved caspase 3 in TGZ-treated cells. Interestingly, when we determined the effect of p53-induced growth inhibition in these three human ovarian cancer cells, we found that they either lacked p53 or contained a mutant form of p53. Furthermore, TGZ induced the expression of endogenous or exogenous p63 and p73 proteins and p63- or p73-directed short hairpin (si) RNAs inhibited the ability of TGZ to regulate expression of p21 in these cells. Thus, our results suggest that PPAR{gamma} ligands can induce growth suppression of ovarian cancer cells and mediate p63 and p73 expression, leading to enhanced growth inhibition and apoptosis. The tumor suppressive effects of PPAR{gamma} ligands may have applications for the treatment of ovarian cancer.

60 APPLIED LIFE SCIENCES↗

Stereological characterization of {gamma}' phase precipitation in CMSX-6 monocrystalline nickel-base superalloy

The purpose of this investigation was to study in detail the means to quantitatively evaluate {gamma}' phase precipitation. Many of the mechanical properties of superalloys are directly influenced by the presence of the {gamma}' (gamma prime) precipitate phase dispersed in a {gamma} matrix phase. The {gamma}' precipitates act as effective barriers to dislocation motion and restrict plastic deformation, particularly at high temperatures. Due to this, it is essential to accurately quantify the {gamma}' precipitate size, volume fraction and distribution. Investigations based on quantitative metallography and image analysis were performed on a monocrystalline nickel-base superalloy taking into consideration various {gamma}' precipitate sizes present in that alloy microstructure. The authors of the present paper propose a new method of quantifying the total volume fraction of the {gamma}' phase applying images of the microstructure with {gamma}' phase precipitates registered using light microscopy, scanning electron microscopy (at two different magnifications) and scanning transmission electron microscopy.

36 MATERIALS SCIENCE↗

Influence of cooling rate on the development of multiple generations of {gamma}' precipitates in a commercial nickel base superalloy

The compositional and microstructural evolution of different generations of {gamma}' precipitates during the continuous cooling of a commercial nickel base superalloy, Rene88DT, has been characterized by three dimensional atom probe tomography coupled with energy-filtered transmission electron microscopy studies. After solutionizing in the single {gamma} phase field, continuous cooling at a very high rate results in a monomodal size distribution of {gamma}' precipitates with a high nucleation density and non-equilibrium compositions. In contrast, a relatively slower cooling rate ({approx} 24 deg. C/min) results in a multi-modal size distribution of {gamma}' precipitates with the larger first generation primary precipitates exhibiting close to equilibrium composition, along with the smaller scale secondary {gamma}' precipitates, exhibiting non-equilibrium composition (excess of Co and Cr, depleted in Al and Ti). The composition of the {gamma} matrix near these precipitates also exhibits similar trends with the composition being closer to equilibrium near the primary precipitates as compared to the secondary precipitates. - Highlights: {yields} Effect of cooling rate on the precipitation of {gamma}' particles in commercial nickel base superalloy. {yields} Couples EFTEM and 3DAP studies to determine the composition and morphology of {gamma}' precipitates. {yields} Determination of near and far field compositional variations within the gamma matrix leading to subsequent precipitation.

36 MATERIALS SCIENCE↗

Structural recognition and functional activation of Fc[gamma]R by innate pentraxins

Pentraxins are a family of ancient innate immune mediators conserved throughout evolution. The classical pentraxins include serum amyloid P component (SAP) and C-reactive protein, which are two of the acute-phase proteins synthesized in response to infection. Both recognize microbial pathogens and activate the classical complement pathway through C1q. More recently, members of the pentraxin family were found to interact with cell-surface Fc{gamma} receptors (Fc{gamma}R) and activate leukocyte-mediated phagocytosis. Here we describe the structural mechanism for pentraxin's binding to Fc{gamma}R and its functional activation of Fc{gamma}R-mediated phagocytosis and cytokine secretion. The complex structure between human SAP and Fc{gamma}RIIa reveals a diagonally bound receptor on each SAP pentamer with both D1 and D2 domains of the receptor contacting the ridge helices from two SAP subunits. The 1:1 stoichiometry between SAP and Fc{gamma}RIIa infers the requirement for multivalent pathogen binding for receptor aggregation. Mutational and binding studies show that pentraxins are diverse in their binding specificity for Fc{gamma}R isoforms but conserved in their recognition structure. The shared binding site for SAP and IgG results in competition for Fc{gamma}R binding and the inhibition of immune-complex-mediated phagocytosis by soluble pentraxins. These results establish antibody-like functions for pentraxins in the Fc{gamma}R pathway, suggest an evolutionary overlap between the innate and adaptive immune systems, and have new therapeutic implications for autoimmune diseases.

59 BASIC BIOLOGICAL SCIENCES↗