Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

Robust and efficient overset grid assembly for partitioned unstructured meshes

This paper presents a method to perform efficient and automated Overset Grid Assembly (OGA) on a system of overlapping unstructured meshes in a parallel computing environment where all meshes are partitioned into multiple mesh-blocks and processed on multiple cores. The main task of the overset grid assembler is to identify, in parallel, among all points in the overlapping mesh system, at which points the flow solution should be computed (field points), interpolated (receptor points), or ignored (hole points). Point containment search or donor search, an algorithm to efficiently determine the cell that contains a given point, is the core procedure necessary for accomplishing this task. Donor search is particularly challenging for partitioned unstructured meshes because of the complex irregular boundaries that are often created during partitioning. Another challenge arises because of the large variation in the type of mesh-block overlap and the resulting large load imbalance on multiple processors. Desirable traits for the grid assembly method are efficiency (requiring only a small fraction of the solver time), robustness (correct identification of all point types), and full automation (no user input required other than the mesh system). Additionally, the method should be scalable, which is an important challenge due to the inherent load imbalance. This paper describes a fully-automated grid assembly method, which can use two different donor search algorithms. One is based on the use of auxiliary grids and Exact Inverse Maps (EIM), and the other is based on the use of Alternating Digital Trees (ADT). The EIM method is demonstrated to be more efficient than the ADT method, while retaining robustness. An adaptive load re-balance algorithm is also designed and implemented, which considerably improves the scalability of the method.

97 MATHEMATICS AND COMPUTING↗

Convex Relaxations of Maximal Load Delivery for Multi-Contingency Analysis of Joint Electric Power and Natural Gas Transmission Networks

Recent increases in gas-fired power generation have engendered increased interdependencies between natural gas and power transmission systems. These interdependencies have amplified existing vulnerabilities in gas and power grids, where disruptions can require the curtailment of load in one or both systems. Although typically operated independently, coordination of these systems during severe disruptions can allow for targeted delivery to lifeline services, including gas delivery for residential heating and power delivery for critical facilities. To address the challenge of estimating maximum joint network capacities under such disruptions, we consider the task of determining feasible steady-state operating points for severely damaged systems while ensuring the maximal delivery of gas and power loads simultaneously, represented mathematically as the nonconvex joint Maximal Load Delivery (MLD) problem. To increase its tractability, we present a mixed-integer convex relaxation of the MLD problem. Then, to demonstrate the relaxation’s effectiveness in determining bounds on network capacities, exact and relaxed MLD formulations are compared across various multi-contingency scenarios on nine joint networks ranging in size from 25 to 1191 nodes. The relaxation-based methodology is observed to accurately and efficiently estimate the impacts of severe joint network disruptions, often converging to the relaxed MLD problem’s globally optimal solution within ten seconds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Lightweight porous plastic plaque

The porosity and platability of various materials were investigated to determine a suitable substrate for nickel-plated electrodes. Immersion, ultrasonics, and flow-through plating techniques were tried using nonproprietary formulations, and proprietary phosphide and boride baths. Modifications to the selected material include variations in formulation and treatment, carbon loading to increase conductivity, and the incorporation of a grid. Problems to be solved relate to determining conductivities and porosities as a function of amount of nickel plated on the plastics; loading; charge and discharge curves of electrodes at different current densities; cell performance; and long-term degradation of electrodes.

Reid, M.↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Micro-grid for Future Planetary Surface Needs

Under the current Artemis Program, the National Aeronautics and Space Administration (NASA) will send its next set of astronauts (first woman and next man) to the Moon by 2024 and establish a sustainable presence on the lunar surface by 2028. The challenge of creating a sustained lunar surface presence is significantly different than previous efforts. Lunar surface operations will require access to continuous and highly reliable power to support mission needs, such as to support ISRU operations. Adding to this challenge, the lunar surface operations are not going to be established over a single effort, rather the system and operations will evolve and grow over time (years). The first initial loads that arrive on the lunar surface will be integrated to their own dedicated power sources. As the lunar surface operations grow, so will the demand for power and at some point these individual loads will require more power than can be generated with any single power device. This power demand drives the need for inter-connecting the loads and power devices to share power between them, resulting in a micro-grid. One of the advantages of developing a lunar surface micro-grid is that allows lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient, rather than negotiating between generation and consumption. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. Creating a lunar surface micro-grid has its advantages, however there are significant challenges associated with an evolvable micro-grid concept. The challenges include how to efficiently transmit large amounts of power (10kW+) long distances (1kW+), how to effectively integrate dissimilar power generation and energy storage devices to maximize power consumption and minimize downtime, and how to physically connect these devices together with a connector that can survive the lunar environment (dust, extreme cold temperatures) and is capable of both astronaut and robotic operation. The basic components of the micro-grid have to be designed to ensure the system is sustainable, modular, and reconfigurable. An interface to the micro-grid has to be designed that allows for additional technologies, some of which may not yet be fully designed, to easily integrate into the micro-grid concept. This presentation discusses these lunar challenges in some more depth and offers a path forward in designing an evolvable micro-grid to meet the needs of the lunar surface operations and proposes a Universal Micro-grid Interface Converter to connect these dissimilar power sources and mission loads to the micro-grid.

Jeffrey Csank↗

V2XConnect: Harmonizing the Landscape of Bidirectional Charging Codes, Standards, and Communication Protocols

The utility grid is constantly evolving with new generation sources and diverse loads from backup generators, backup batteries, rooftop photovoltaics (PV), and flexible charging loads. Each of these technologies presents consumers with an opportunity to work with their local utility to promote grid stability, reliability, and affordability. Through a wide range of programs, utilities are incentivizing the use of these resources to benefit the grid. However, especially for devices with inverters that supply power back to the grid, it is important that these assets comply with local grid codes to ensure human safety, power quality, and grid reliability. One of the most promising of these new technologies is the bidirectional electric vehicle (EV) coupled with bidirectional electric vehicle supply equipment (EVSE). This report introduces the technologies that enable bidirectional charging and how these systems operate. It then outlines the necessary interconnection codes and industry standards that govern the operations of grid-tied inverters, including those in bidirectional charging. A key challenge is then outlined from the complex landscape of communication protocols and proprietary systems designed to coordinate these grid assets. Finally, a single gateway solution is proposed to harmonize communications between all assets across an entire site for a cohesive response to grid codes and utility programs that is flexible enough to support a range of market options.

33 ADVANCED PROPULSION SYSTEMS↗

Second use of transportation batteries: Maximizing the value of batteries for transportation and grid services

Plug-in hybrid electric vehicles (PHEVs) and electric vehicles (EVs) are expected to gain significant market share over the next decade. The economic viability for such vehicles is contingent upon the availability of cost-effective batteries with high power and energy density. For initial commercial success, government subsidies will be highly instrumental in allowing PHEVs to gain a foothold. However, in the long-term, for electric vehicles to be commercially viable, the economics have to be self-sustaining. Towards the end of battery life in the vehicle, the energy capacity left in the battery is not sufficient to provide the designed range for the vehicle. Typically, the automotive manufacturers indicated the need for battery replacement when the remaining energy capacity reaches 70-80%. There is still sufficient power (kW) and energy capacity (kWh) left in the battery to support various grid ancillary services such as balancing, spinning reserve, load following services. As renewable energy penetration increases, the need for such balancing services is expected to increase. This work explores optimality for the replacement of transportation batteries to be subsequently used for grid services. This analysis maximizes the value of an electric vehicle battery to be used as a transportation battery (in its first life) and then as a resource for providing grid services (in its second life). The results are presented across a range of key parameters, such as depth of discharge (DOD), number of batteries used over the life of the vehicle, battery life in vehicle, battery state of health (SOH) at end of life in vehicle and ancillary services rate. The results provide valuable insights for the automotive industry into maximizing the utility and the value of the vehicle batteries in an effort to either reduce the selling price of EVs and PHEVs or maximize the profitability of the emerging electrification of transportation.

(DOD)↗

Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions

There are fewer conventional, dispatchable generation resources and more variable renewable energy (VRE) and distributed energy resources (DERs). There is more uncertainty from bulk-level VRE and net demand from distribution systems with high DER levels. FAST-DERMS aims to develop and demonstrate a scalable solution for managing uncertainties in supply and demand at the grid edge. We propose that distribution system operators (DSOs) provide firm net load forecasts to the bulk system operator's energy management system (EMS).

distributed energy resources↗

Smart Grid Enabled L2 EVSE for the Commercial Market

In 2011, the DOE issued Funding Opportunity DE-FOA-0000554 as a means of addressing two major task areas identified by the Grid Integration Tech Team (GITT) that would help transition Electric vehicles from a market driven by early adopters and environmental supporters to a market with mainstream volumes. Per DE-FOA-0000554, these tasks were: To reduce the cost of Electric Vehicle Supply Equipment (EVSE), thereby increasing the likelihood of the build out of EV charging infrastructure. The goal of increasing the number of EVSE available was to ease concerns over range anxiety, and promote the adoption of electric vehicles: To allow EV loads to be managed via the smart grid, thereby maintaining power quality, reliability and affordability, while protecting installed distribution equipment. In December of that year, the DOE awarded one of the two contracts targeted toward commercial EVSE to Eaton, and in early 2012, we began in earnest the process of developing a Smart Grid Enable L2 EVSE for the Commercial Market (hereafter known as the DOE Charger). The design of the Smart Grid Enabled L2 EVSE was based primarily on the FOA requirements along with input from the Electric Transportation Infrastructure product line (hereafter ETI) marketing team who aided in development of the customer requirements.

33 ADVANCED PROPULSION SYSTEMS↗

PinBus Interface for Interoperable, Grid-Responsive Devices

A very simple appliance interface was suggested by this author and his co-authors during Grid-Interop 2007. The approach was based on a successful collaboration between utilities, a major appliance manufacture, and the manufacturer of a load control module during the U.S. Department of Energy’s Grid Friendly Appliance project. The suggested approach was based on the assumption that demand-response objectives could be effectively communicated to and from many small electrical loads like appliances by simply agreeing on the meaning of the binary states of several shared connector pins. It was argued that this approach could pave the way for a wave of demand-response-ready appliances and greatly reduced expenses for utilities’ future demand-response programs. The approach could be supported by any of the many competing serial communication protocols and would be generally applicable to most end-use devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources: Preprint

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.

contingencies↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.

data-driven forecasting↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of Granular Control on Customers’ Perspective and Behavior with Automated Demand Response Systems

Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.

Schetrit, Oren↗

Adoption of AI in the Utility T&D Sector: Use Cases, Consequence, Assessment and Benefits

Digital transformation and utilization of artificial intelligence (AI) in the electric grid are fundamentally changing the industry’s approach to common problems and enabling a broader paradigm shift in grid planning and operations. The change in approach is circularly both enabling and driving modernization, with load growth and reliable management of data center and AI infrastructure shifting away from planning approaches with relatively predictable behaviors and toward a mix of consumer and industrial choices that surpass human cognitive abilities to process. This movement has potential to condition humans to not understand the system on which the AI depends, while requiring it for development of the necessary infrastructure. Approaches which would address most likely grid conditions and events, such as faults, aging of equipment, and weather, now must also account for large loads which shift not based upon weather or time of day, but the computational load. Quantifying computational load is independent of the traditional grid forecasting variables, where a data center’s aggregate load is determined by user and AI system behavior and decoupled from normal grid planning and operations. AI is both the cause and solution for these challenges, with new grid planning tools integrating massive amounts of decisions into frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Assessment of Virtual Battery Potential from Building Loads

Flexibility from building loads can be used for integrating renewable energy and providing different grid services. It is challenging to quantify and compare the flexibility from different classes of building loads due to their diversified characteristics and dynamics. Methodology has been proposed to model building loads as a virtual battery (VB), which is simple and general, yet able to capture physical characteristics of building loads, environmental parameters, human behavior, and other factors. This paper presents a regional assessment of VB technical potential and economic benefits from residential loads and commercial buildings. Housing, population, weather station, and climate zone information have been collected and used to estimate VB technical potential. Energy and ancillary service prices are then used for economic benefits assessment and analysis.

Wu, Di↗