SIMS prototype system 1 test results: Engineering analysis

The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

Source record↗

System design package for SIMS prototype system 4, solar heating and domestic hot water

The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

Source record↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

Solar heating and cooling system design and development

The progress of the program during the sixth program quarter is reported. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. The William O'Brien single-family heating system was installed and is operational. The New Castle single-family heating residence is under construction. The Kansas University (KU) system is in the final design stages. The 25 ton cooling subsystem for KU is the debugging stage. Pressure drops that were greater than anticipated were encountered. The 3 ton simulation work is being finalized and the design parameters for the Rankine system were determined from simulation output.

Source record↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal convective cooling systems for hypersonic aircraft

Parametric studies were conducted to investigate the relative merits of construction materials, coolants, and cooled panel concepts for internal convective cooling systems applied to airframe structures of hydrogen-fueled hypersonic aircraft. These parametric studies were then used as a means of comparing various cooled structural arrangements for a hypersonic transport and a hypersonic research airplane. The cooled airplane studies emphasized weight aspects as related to the choice of materials, structural arrangements, structural temperatures, and matching of the cooling system heat load to the available hydrogen fuel-flow heat sink. Consideration was given to reliability and to fatigue and fracture aspects, as well. Even when auxiliary thermal protection system items such as heat shielding, insulation, and excess hydrogen for cooling are considered the more attractive actively cooled airframe concepts indicated potential payload increases of from 40 percent to over 100 percent for the hypersonic transport as compared to the results of previous studies of the same vehicle configuration with an uncooled airframe.

Anthony, F. M.↗

Contact Heat Exchanger

Fluid pressure controls contact between heat pipe and heat exchanger. Heat exchanger system in cross section provides contact interface between fluid system and heat pipe with easy assembly/disassembly of heat-pipe/ pumped-liquid system. Originally developed for use in space, new device applicable on Earth where fluid system is linked with heat pipe, where rapid assembly/disassembly required, or where high pressures or corrosive fluids used.

Fleming, M. L.↗

Heat pipe radiator

A 15,000 watt spacecraft waste heat rejection system utilizing heat pipe radiator panels was investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500 watt radiator panel was designed, built and tested. The panel, which is a module of the 15,000 watt system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiating fin. The thermal load to the VCHP is supplied by a Freon-21 liquid loop via an integral heat exchanger. Descriptions of the results of the system studies and details of the radiator design are included along with the test results for both the heat pipe components and the assembled radiator panel. These results support the feasibility of using heat pipes in a spacecraft waste heat rejection system.

Swerdling, B.↗

Direct Nonlinear Approximation for Security Region Boundary of Integrated Energy Systems: A Polynomial Chaos Expansion Solution

The strong interdependence of electricity, gas, and heating systems can facilitate fault propagation within integrated energy systems (IESs), posing significant challenges to secure operation. This paper proposes a polynomial chaos expansion (PCE)-based approximation method to accurately characterize the IES security region boundary (IES–SRB). By integrating the Karush-Kuhn-Tucker conditions with PCE theory, the IES-SRB approximation problem is reformulated as a set of nonlinear equations concerning the approximation coefficients. Using the Galerkin projection method, these equations are further transformed into a system of projection equations that govern the polynomial approximation coefficients in the IES-SRB approximation. To reduce computational complexity while maintaining high approximation accuracy, a piecewise polynomial approximation method is proposed. Numerical studies on the E39-G20-H6 and E118-G96-H52 IES test systems demonstrate that the proposed method can accurately and effectively construct IES security regions.

Wu, Chenghao [Northeast Electric Power University]↗

High temperature metal purification using a compact portable rf heating and levitation system on the wake shield

The Wake Shield Facility (WSF) can provide an ideal vacuum environment for the purification of high temperature metals in space. The Modular Electromagnetic Levitator (MEL), will provide the opportunity to study undercooling of metals in space and allow to determine material properties in space. The battery powered rf levitation and heating system developed for the MEL demonstrated efficiency of 36 percent. This system is being considered to purify metals at temperatures below 3000 C.

Hahs, C. A.↗

Impact of suprathermal ions on neutron yield in the pre-DT phase of ITER operation

An assessment of neutron production during the pre-fusion power-operation (PFPO) phase has been carried out for a representative set of plasma scenarios predicted by the ITER Research Plan. A range of heating systems, namely neutral beam injection (NBI) (hydrogen), electron cyclotron resonance heating (ECRH), and ion cyclotron resonance heating (ICRH) are planned to be used for PFPO studies in helium, hydrogen, and mixed hydrogen–helium plasmas. Fast ions (protons and 3He) originating from NBI and ICRH systems can increase neutron production in PFPO plasmas by directly interacting with intrinsic Be impurities or through secondary processes, as also evidenced at JET. The generation of fast ions in ITER PFPO scenarios has been modelled using the ASTRA-NBI and TORIC-SSFPQL codes. A significant impact of the synergy between hydrogen NBI and hydrogen-minority ICRH on neutron production in helium plasmas is reported. In addition, the stability of the toroidicity-induced Alfvén eigenmodes (TAE) is analyzed for PFPO plasmas with a high pressure of suprathermal ions and a weak reversed shear. The possible impact of sawtooth oscillations and TAEs on neutron production is discussed, based on a linear stability analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gravity Scaling of a Power Reactor Water Shield

Water based reactor shielding is being considered as an affordable option for use on initial lunar surface power systems. Heat dissipation in the shield from nuclear sources must be rejected by an auxiliary thermal hydraulic cooling system. The mechanism for transferring heat through the shield is natural convection between the core surface and an array of thermosyphon radiator elements. Natural convection in a 100 kWt lunar surface reactor shield design has been previously evaluated at lower power levels (Pearson, 2007). The current baseline assumes that 5.5 kW are dissipated in the water shield, the preponderance on the core surface, but with some volumetric heating in the naturally circulating water as well. This power is rejected by a radiator located above the shield with a surface temperature of 370 K. A similarity analysis on a water-based reactor shield is presented examining the effect of gravity on free convection between a radiation shield inner vessel and a radiation shield outer vessel boundaries. Two approaches established similarity: 1) direct scaling of Rayleigh number equates gravity-surface heat flux products, 2) temperature difference between the wall and thermal boundary layer held constant on Earth and the Moon. Nussult number for natural convection (laminar and turbulent) is assumed of form Nu = CRa(sup n). These combined results estimate similarity conditions under Earth and Lunar gravities. The influence of reduced gravity on the performance of thermosyphon heat pipes is also examined.

Reid, Robert S.↗

Corrosion inhibitors for solar heating and cooling systems

Inhibitors which appeared promising in previous tests and additional inhibitors including several proprietary products were evaluated. Evaluation of the inhibitors was based on corrosion protection afforded an aluminum-mild steel-copper-stainless steel assembly in a hot corrosive water. Of the inhibitors tested two were found to be effective and show promise for protecting multimetallic solar heating systems.

Humphries, T. S.↗

Application of solar energy; Proceedings of the First Southeastern Conference, Huntsville, Ala., March 24-26, 1975

Topics related to architectural and institutional considerations are discussed along with studies of components and subsystems. Subjects in the area of system design and analysis are also explored. Residential and commercial applications are considered, taking into account hot-water usage in a typical single-family residence, solar heating and cooling of mobile homes, aspects of design and performance in the case of a solar heating system using a reflective pyramid optical condenser, solar heating in a Boston school, a performance analysis of solar service hot water systems, comparative performance analyses of three solar heated and cooled buildings, and the use of solar energy in a soybeam processing operation. Applications related to power generation are also examined, giving attention to solar thermal electric power systems and photovoltaic research. Individual items are announced in this issue.

Wu, S. T.↗

Finite Element Modeling of a Non-Isothermal Superplastic-Like Forming Process

Conventional superplastic forming (SPF) has been modified to increase the productivity and reduce some of the drawbacks, such as high forming temperature and high percentage thinning, to suit the automotive industries. One of the modifications was to combine between the conventional SPF and the use of a mechanical preformed blank to form the non-superplastic grade aluminum alloy (AA5083-O). The requirement of high temperature usually results in microstructural defects during forming process. In this paper, finite element modeling was adopted to investigate the superplastic-like forming process using the non-isothermal heating system. In the simulation, two phases (mechanical pre-forming and gas blow for ming) of the process were conducted under different temperatures, where the material was mechanically drawn into the die cavity at 200 deg. C in the first phase, and it formed with gas pressure applied at a global temperature increasing from 400 deg. C to 500 deg. C. Because of the non-isothermal heating of material, it was found that it had enough ductility to flow more easily in the specific zones (die corners and radius). Additionally, FEM results showed that a better formed part can be obtained by the increasing temperature forming, compared to the stable temperature phase.

36 MATERIALS SCIENCE↗

Portable linear-focused solar thermal energy collecting system

A solar heat collection system is provided by utilizing a line-focusing device that is effectively a cylindrically curved concentrator within a protected environment formed by a transparent inflatable casing. A target, such as a fluid or gas carrying conduit is positioned within or near the casing containing the concentrator, at the line focus of the concentrator. The casing can be inflated at the site of use by a low pressure air supply to form a unitary light weight structure. The collector, including casing, concentrator and target, is readily transportable and can be used either at ground level or on rooftops. The inflatable concentrator can be replaced with a rigid metal or other concentrator while maintaining the novel advantages of the whole solar heat collection system.