Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A high voltage pulse power supply for metal plasma immersion ion implantation and deposition

We describe the design and implementation of a high voltage pulse power supply (pulser) that supports the operation of a repetitively pulsed filtered vacuum arc plasma deposition facility in plasma immersion ion implantation and deposition (Mepiiid) mode. Negative pulses (micropulses) of up to 20 kV in magnitude and 20 A peak current are provided in gated pulse packets (macropulses) over a broad range of possible pulse width and duty cycle. Application of the system consisting of filtered vacuum arc and high voltage pulser is demonstrated by forming diamond-like carbon (DLC) thin films with and without substrate bias provided by the pulser. Significantly enhanced film/substrate adhesion is observed when the pulser is used to induce interface mixing between the DLC film and the underlying Si substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

True Zero Degree Incident Implants on VIISta3000

The deliberate use of channeling to control depth profiles has come of age in the application to CMOS imaging sensor device manufacturing. In order to enable the true zero implant application on VIISta3000, we have optimized beam incidence angle control, using beam optics models and experimental measurements. The experiment measurement and the beam optics analysis results agree, showing a variation of less than 0.03 deg. (1{sigma}) across the wafer and from wafer to wafer. Achieving this accuracy in a manufacturing environment requires careful calibration and tight control of the collimator magnet and the mechanical scan system. In this paper we discuss the root cause of beam incidence angle variation on VIISta3000 and explain the calibration and optimization used to insure the consistent minimized beam incidence angle. We show experimental data, including ThermaWave and SIMS profiles.

43 PARTICLE ACCELERATORS↗

Extending Ion Source Life on High Current Ion Implant Tools with In-Situ Chemical Cleaning

Ion source replacement is generally the most frequent maintenance activity on an ion implanter impacting both productivity and consumable costs. In this paper we review the different mechanisms responsible for ion source failure. We report on in-situ chemical cleaning tests conducted at Toshiba Oita, which have shown potential for significant extension in source life. Several factors impact the effectiveness of xenon difluoride including failure modes, cleaning time and flow rates.

42 ENGINEERING↗

Molecular Ion Beam Transportation for Low Energy Ion Implantation

A joint research and development of steady state intense boron ion sources for 100's of electron-volt ion implanters has been in progress for the past five years. Current density limitation associated with extracting and transporting low energy ion beams result in lower beam currents that in turn adversely affects the process throughput. The transport channel with electrostatic lenses for decaborane (B{sub 10}H{sub 14}) and carborane (C{sub 2}B{sub 10}H{sub 12}) ion beams transportation was developed and investigated. The significant increase of ion beam intensity at the beam transport channel output is demonstrated. The transport channel simulation, construction and experimental results of ion beam transportation are presented.

43 PARTICLE ACCELERATORS↗

In-Situ RBS Channelling Studies Of Ion Implanted Semiconductors And Insulators

The experimental set-up at the ion beam facility in Jena allows the performance of Rutherford backscattering spectrometry (RBS) in channeling configuration at any temperature between 15 K and room temperature without changing the environment or the temperature of the sample. Doing RBS channeling studies at 15 K increases the sensitivity to defects, because the influence of lattice vibrations is reduced. Thus, the very early processes of ion induced damage formation can be studied and the cross section of damage formation per ion in virgin material, P, can be determined. At 15 K ion-beam induced damage formation itself can be investigated, because the occurrence of thermal effects can be widely excluded. In AlAs, GaN, and ZnO the cross section P measured at 15 K can be used to estimate the displacement energy for the heavier component, which is in reasonable agreement with other experiments or theoretical calculations. For a given ion species (here Ar ions) the measured cross section P exhibits a quadratic dependence P{proportional_to}P{sub SRIM}{sup 2} with P{sub SRIM} being the value calculated with SRIM using established displacement energies from other sources. From these results the displacement energy of AlN can be estimated to about 40 eV. Applying the computer code DICADA to calculate the depth distribution of displaced lattice atoms from the channeling spectra, indirect information about the type of defects produced during ion implantation at 15 K can be obtained. In some materials like GaN or ZnO the results indicate the formation of extended defects most probably dislocation loops and thus suggest an athermal mobility of defect at 15 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation Of Ion Implantation Into Nuclear Materials And Comparison With Experiment

A new many-body potential is proposed for pure molybdenum that consists of using ab initio and atomistic MD simulation methods verified against existing surface erosion experimental data. Mo is an important material for metallic U-Mo alloys for using them in low-enriched fuels. Several new Xe-Mo potentials were also parameterized by comparing the calculated sputtering yield of a Mo-surface bombarded with Xe ions with experimental data. Calculated results were also compared with defect distributions in CeO{sub 2} crystals obtained from experiments by 500 keV Xe implantation at the doses of 1x10{sup 17} ions/cm{sup 2} at several temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface damage on diamond membranes fabricated by ion implantation and lift-off

Thin membranes with excellent optical properties are essential elements in diamond based photonic systems. Due to the chemical inertness of diamond, ion beam processing must be employed to carve photonic structures. One method to realize such membranes is ion-implantation graphitization followed by chemical removal of the sacrificial graphite. The interface revealed when the sacrificial layer is removed has interesting properties. To investigate this interface, we employed the surface sensitive technique of grazing angle channeled Rutherford backscattering spectroscopy. Even after high temperature annealing and chemical etching a thin layer of damaged diamond remains, however, it is removed by hydrogen plasma exposure.

36 MATERIALS SCIENCE↗

Rhenium ion beam for implantation into semiconductors

At the ion source test bench in Institute for Theoretical and Experimental Physics the program of ion source development for semiconductor industry is in progress. In framework of the program the Metal Vapor Vacuum Arc ion source for germanium and rhenium ion beam generation was developed and investigated. It was shown that at special conditions of ion beam implantation it is possible to fabricate not only homogenous layers of rhenium silicides solid solutions but also clusters of this compound with properties of quantum dots. At the present moment the compound is very interesting for semiconductor industry, especially for nanoelectronics and nanophotonics, but there is no very developed technology for production of nanostructures (for example quantum sized structures) with required parameters. The results of materials synthesis and exploration are presented.

36 MATERIALS SCIENCE↗

Formation of NiSi{sub 2} nanoclusters by Ni ion implantation into Si(100) and the effect of preinjection of Si{sub 2}{sup +} ions

Cluster ions can produce surface craters and amorphous ion tracks in semiconductors. This process in combination with defect mediated diffusion can be applied to fabricate buried nanowires. 1.4 MeV Si{sub 2}{sup +} ions at low fluences and 400 keV Ni{sup +} ions at high fluence are implanted into Si(100) and annealed at 600 deg. C. NiSi{sub 2} nanoclusters are formed and TEM measurements show surface craters of around 30 nm diameter which are followed by amorphous tracks of diameter 15 nm caused by the Si{sub 2}{sup +} ions in Si substrate. 50 nm long finger like buried vertical nanowires from the silicide clusters are formed along the amorphous track which is due to diffusion of Nickel atoms towards the surface mediated by the defects in the track. It is a step closer to the fabrication of buried nanowires.

36 MATERIALS SCIENCE↗

Empirical modeling of the cross section of damage formation in ion implanted III-V semiconductors

In this letter, the cross section of damage formation per individual ion is measured for III-V compound semiconductors ion implanted at 15 K, applying Rutherford backscattering spectrometry. An empirical model is proposed that explains the measured cross sections in terms of quantities representing the primary energies deposited in the displacement of lattice atoms and in electronic interactions. The resulting formula allows the prediction of damage formation for low temperatures and low ion fluences in these materials and can be taken as a starting point for further quantitative modeling of damage formation including secondary effects such as temperature and ion flux.

36 MATERIALS SCIENCE↗

Enhanced x-ray imaging for a thin film cochlear implant with metal artefacts using phase retrieval tomography

Phase retrieval tomography has been successfully used to enhance imaging in systems that exhibit poor absorption contrast. However, when highly absorbing regions are present in a sample, so-called metal artefacts can appear in the tomographic reconstruction. We demonstrate that straightforward approaches for metal artefact reconstruction, developed in absorption contrast tomography, can be applied when using phase retrieval. Using a prototype thin film cochlear implant that has high and low absorption components made from iridium (or platinum) and plastic, respectively, we show that segmentation of the various components is possible and hence measurement of the electrode geometry and relative location to other regions of interest can be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoporosity induced by ion implantation in deposited amorphous Ge thin films

The formation of a nano-porous structure in amorphous Ge thin film (sputter-deposited on SiO{sub 2}) during ion irradiation at room temperature with 300 keV Ge{sup +} has been observed. The porous film showed a sponge-like structure substantially different from the columnar structure reported for ion implanted bulk Ge. The voids size and structure resulted to be strongly affected by the material preparation, while the volume expansion turned out to be determined only by the nuclear deposition energy. In SiGe alloys, the swelling occurs only if the Ge concentration is above 90%. These findings rely on peculiar characteristics related to the mechanism of voids nucleation and growth, but they are crucial for future applications of active nanostructured layers such as low cost chemical and biochemical sensing devices or electrodes in batteries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear radiation detectors based on a matrix of ion-implanted p-i-n diodes on undoped GaAs epilayers

Samples of nuclear detectors which represent matrices of p-i-n diodes were fabricated based on undoped gallium arsenide epitaxial layers by ion implantation technology. The detectors have a size of the active area of 0.4 Multiplication-Sign 0.4 and 0.9 Multiplication-Sign 0.9 cm{sup 2}. Electrical characteristics of fabricated detectors and results of measurements of fast neutrons spectra of {sup 241}Am-Be source by the recoil protons method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of an RF plasma ion source for ion implantation

A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

43 PARTICLE ACCELERATORS↗

Optical absorption in silicon layers in the presence of charge inversion/accumulation or ion implantation

We determine the optical losses in gate-induced charge accumulation/inversion layers at a Si/SiO{sub 2} interface. Comparison between gate-induced charge layers and ion-implanted thin silicon films having an identical sheet resistance shows that optical losses can be significantly lower for gate-induced layers. For a given sheet resistance, holes produce higher optical loss than electrons. Measurements have been performed at λ = 1550 nm.

36 MATERIALS SCIENCE↗

Supersaturating silicon with transition metals by ion implantation and pulsed laser melting

We investigate the possibility of creating an intermediate band semiconductor by supersaturating Si with a range of transition metals (Au, Co, Cr, Cu, Fe, Pd, Pt, W, and Zn) using ion implantation followed by pulsed laser melting (PLM). Structural characterization shows evidence of either surface segregation or cellular breakdown in all transition metals investigated, preventing the formation of high supersaturations. However, concentration-depth profiling reveals that regions of Si supersaturated with Au and Zn are formed below the regions of cellular breakdown. Fits to the concentration-depth profile are used to estimate the diffusive speeds, v{sub D,} of Au and Zn, and put lower bounds on v{sub D} of the other metals ranging from 10{sup 2} to 10{sup 4} m/s. Knowledge of v{sub D} is used to tailor the irradiation conditions and synthesize single-crystal Si supersaturated with 10{sup 19} Au/cm{sup 3} without cellular breakdown. Values of v{sub D} are compared to those for other elements in Si. Two independent thermophysical properties, the solute diffusivity at the melting temperature, D{sub s}(T{sub m}), and the equilibrium partition coefficient, k{sub e}, are shown to simultaneously affect v{sub D}. We demonstrate a correlation between v{sub D} and the ratio D{sub s}(T{sub m})/k{sub e}{sup 0.67}, which is exhibited for Group III, IV, and V solutes but not for the transition metals investigated. Nevertheless, comparison with experimental results suggests that D{sub s}(T{sub m})/k{sub e}{sup 0.67} might serve as a metric for evaluating the potential to supersaturate Si with transition metals by PLM.

36 MATERIALS SCIENCE↗

Note: An ion source for alkali metal implantation beneath graphene and hexagonal boron nitride monolayers on transition metals

The construction of an alkali-metal ion source is presented. It allows the acceleration of rubidium ions to an energy that enables the penetration through monolayers of graphene and hexagonal boron nitride. Rb atoms are sublimated from an alkali-metal dispenser. The ionization is obtained by surface ionization and desorption from a hot high work function surface. The ion current is easily controlled by the temperature of ionizer. Scanning Tunneling Microscopy measurements confirm ion implantation.

36 MATERIALS SCIENCE↗

Electrical properties and electronic structure of Si-implanted hexagonal boron nitride films

Si ion implantation with a set of ion energies and ion doses was carried out to dope hexagonal boron nitride (hBN) thin films synthesized by radio-frequency magnetron sputtering. Hall effect measurements revealed n-type conduction with a low resistivity of 0.5 Ω cm at room temperature, corresponding to an electron concentration of 2.0 × 10{sup 19} cm{sup −3} and a mobility of 0.6 cm{sup 2}/V s. Temperature-dependent resistivity measurements in a wide temperature range from 50 to 800 K demonstrated two shallow donor levels in the hBN band gap induced by Si doping, which was in consistence with the theoretical calculation by density function theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗