Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Operando synchrotron X-ray analysis of melt pool dynamics in an Al-Sn immiscible alloy

The melt flow in an Al-50vol.% Sn immiscible alloy, produced by single-track laser melting of Al and Sn elemental powders, was studied in real time. High-speed synchrotron X-ray imaging was used to track Al and Sn liquids’ movements, and also to examine elemental distributions in the laser tracks, complimented by electron microscopy after solidification. Key aspects, including melt pool geometry, keyhole instability, and flow dynamics (flow pattern and velocity), were examined using digital image analysis. Relatively deeper melt pools formed at 400 W and 300 mm/s exhibited greater stability, with smooth surfaces, consistent outward flow, and minor vortices near the keyhole. In contrast, shallower pools produced at higher scanning speeds (>500 mm/s) demonstrated greater instability with increased surface waviness, and stronger velocity fluctuations, leading to numerous micro-vortices and increased Al-Sn heterogeneity. Velocity scale estimations, supported by experimental observations, examined the roles of vapour pressure, Marangoni effect, buoyancy, inertial, and surface tension forces in the flow. The results revealed that vapour pressure and mechanical waves dominated at high scanning speeds (shallow pools), while Marangoni forces were equally significant in deep pools at lower speeds (300 mm/s). Buoyancy was found to have minimal impact in both cases. Furthermore, the interaction between inertial and surface tension forces played a critical role in determining the degree of waviness of the pools’ surfaces. These findings offer valuable insights into melt pool dynamics during laser processing of immiscible alloys and other metallic systems using elemental powders, and provide guidance for developing high-fidelity computational fluid dynamics models.

immiscible alloys↗

Spatial intratumoral heterogeneity of proliferation in immunohistochemical images of solid tumors

Purpose: The interactions of neoplastic cells with each other and the microenvironment are complex. To understand intratumoral heterogeneity, subtle differences should be quantified. Main factors contributing to heterogeneity include the gradient ischemic level within neoplasms, action of microenvironment, mechanisms of intercellular transfer of genetic information, and differential mechanisms of modifications of genetic material/proteins. This may reflect on the expression of biomarkers in the context of prognosis/stratification. Hence, a rigorous approach for assessing the spatial intratumoral heterogeneity of histological biomarker expression with accuracy and reproducibility is required, since patterns in immunohistochemical images can be challenging to identify and describe. Methods: A quantitative method that is useful for characterizing complex irregular structures is lacunarity; it is a multiscale technique that exhaustively samples the image, while the decay of its index as a function of window size follows characteristic patterns for different spatial arrangements. In histological images, lacunarity provides a useful measure for the spatial organization of a biomarker when a sampling scheme is employed and relevant features are computed. The proposed approach quantifies the segmented proliferative cells and not the textural content of the histological slide, thus providing a more realistic measure of heterogeneity within the sample space of the tumor region. The aim is to investigate in whole sections of primary pancreatic neuroendocrine neoplasms (pNENs), using whole-slide imaging and image analysis, the spatial intratumoral heterogeneity of Ki-67 immunostains. Unsupervised learning is employed to verify that the approach can partition the tissue sections according to distributional heterogeneity. Results: The architectural complexity of histological images has shown that single measurements are often insufficient. Inhomogeneity of distribution depends not only on percentage content of proliferation phase but also on how the phase fills the space. Lacunarity curves demonstrate variations in the sampled image sections. Since the spatial distribution of proliferation in each case is different, the width of the curves changes too. Image sections that have smaller numerical variations in the computed features correspond to neoplasms with spatially homogeneous proliferation, while larger variations correspond to cases where proliferation shows various degrees of clumping. Grade 1 (uniform/nonuniform: 74%/26%) and grade 3 (uniform: 100%) pNENs demonstrate a more homogeneous proliferation with grade 1 neoplasms being more variant, while grade 2 tumor regions render a more diverse landscape (50%/50%). Hence, some cases show an increased degree of spatial heterogeneity comparing to others with similar grade. Whether this is a sign of different tumor biology and an association with a more benign/malignant clinical course needs to be investigated further. The extent and range of spatial heterogeneity has the potential to be evaluated as a prognostic marker. Conclusions: The association with tumor grade as well as the rationale that the methodology reflects true tumor architecture supports the technical soundness of the method. This reflects a general approach which is relevant to other solid tumors and biomarkers. Drawing upon the merits of computational biomedicine, the approach uncovers salient features for use in future studies of clinical relevance.

60 APPLIED LIFE SCIENCES↗

Phase I Final Technical Report: High-Resolution Gamma-ray Imaging and Spectroscopy for Special Nuclear Material Assay (GeGI-DNN)

The Phase I program focused on the development, implementation, and evaluation of spectral and spatial algorithms to improve the intrinsic image quality and efficiency of GeGI-DNN for count-starved (low activity) measurement scenarios. As a direct result of the Phase-I achievements, Pinhole imaging efficiency was dramatically improved, Compton imaging performance was improved by incorporating a statistical treatment of the Compton image, and quantitative image analysis routines were developed and implemented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nested-hierarchical scene models and image segmentation

An improved model of scenes for image analysis purposes, a nested-hierarchical approach which explicitly acknowledges multiple scales of objects or categories of objects, is presented. A multiple-pass, region-based segmentation algorithm improves the segmentation of images from scenes better modeled as a nested hierarchy. A multiple-pass approach allows slow and careful growth of regions while interregion distances are below a global threshold. Past the global threshold, a minimum region size parameter forces development of regions in areas of high local variance. Maximum and viable region size parameters limit the development of undesirably large regions. Application of the segmentation algorithm for forest stand delineation in TM imagery yields regions corresponding to identifiable features in the landscape. The use of a local variance, adaptive-window texture channel in conjunction with spectral bands improves the ability to define regions corresponding to sparsely stocked forest stands which have high internal variance.

Woodcock, C.↗

Convective Melting of Particles in Flow Under Microgravity Conditions

Study of melting of dispersed or packed solid particles in a fluid under gravity and microgravity conditions provides benchmark information for many engineering applications such as material processing, environmental assessment and protection and space fire protection. During such processes, packed or dispersed solid particles are interacting with fluid flow at above-melting temperatures. By unmasking the buoyancy effects in coupled flow, phase change and heat transport phenomena, a better understanding of melting rate in non-thermal equilibrium, convective conditions can be studied. A series of flight experiments were conducted onboard the NASA KC-135 Microgravity Research Airplane. The Particle Melting in Plow (PMF) module was designed to allow flow through the initially packed ice particles at controlled temperature and velocity. To achieve this, a close-loop flow system was designed. Video images were taken to record the visualization of the melting process, from which a time variation of packed particle thickness distribution at different times can be obtained by the image analysis method. The fluid temperature distribution within the melting zone is measured by thermocouples. An infrared camera was mounted from the top of the test section to record the ice-water thermal images at a given location. The results from thermal images yield local temperature variation between melting solid and liquid and local Stephan number. Typical results for a number of cases are presented. The mathematical model, describing mass, energy, and momentum balance equations for the liquid and solid phases, is presented. It is found that melting rate is influenced mainly by the ratio of Reynolds number (based on the initial particle diameter) to the Froud number, and Stephan number. At the absence of gravity, Froud number approaches zero, Reynolds number and Stephan number become dominant factors governing the melting rate. The numerically determined results are compared with the experimental ones. It is found that the discrepancy between the predicted and measured melting rate is largely due to the inaccuracy in the constitutive equations for effective thermal physical properties, such as effective thermal conductivity and diffusivity, and transport properties, such as particle interaction coefficient, and local heat transfer coefficient of particles.

Stewart, C.↗

Optical Depth Retrievals from HRSC Stereo Images

Mars Express is due to arrive in orbit around Mars during the last days of 2003. A primary task of its mission is to map Mars in stereo with the High Resolution Stereo Camera (HRSC) at a spatial resolution of up to 12 m. The Martian atmosphere contains large amounts of dust and other aerosols that scatter light and influence the images. Therefore, image analysis requires careful consideration of these atmospheric effects. An essential parameter to consider is the optical depth. It will be possible to map the optical depth of the Martian atmosphere from HRSC stereo images by analyzing contrast differences. Software to this purpose has been developed at the Max-Planck Institute for Aeronomy in Lindau Germany. We present examples of optical depth-retrievals from airborne HRSC-A images of a region in the French Alps.

N M Hoekzema↗

ESIAC: A data products system for ERTS imagery (time-lapse viewing and measuring)

An Electronic Satellite Image Analysis Console (ESIAC) has been developed for visual analysis and objective measurement of earth resources imagery. The system is being employed to process imagery for use by USGS investigators in several different disciplines studying dynamic hydrologic conditions. The ESIAC provides facilities for storing registered image sequences in a magnetic video disc memory for subsequent recall, enhancement, and animated display in monochrome or color. The unique feature of the system is the capability to time-lapse the ERTS imagery and/or analytic displays of the imagery. Data products have included quantitative measurements of distances and areas, brightness profiles, and movie loops of selected themes. The applications of these data products are identified and include such diverse problem areas as measurement of snowfield extent, sediment plumes from estuary dicharge, playa inventory, phreatophyte and other vegetation changes. A comparative ranking of the electronic system in terms of accuracy, cost effectiveness and data output shows it to be a viable means of data analysis.

Evans, W. E.↗

SU-F-J-153: ACR MRI Phantom Test On a 1.5T MR-Simulator with Flexible Coils Setting and Performance Comparison to Volumetric Head Coil Setting

Purpose: To accommodate head-and-neck (HN) RT simulation scan with immobilization, sub-optimized flexible radiofrequency coils have to be used on an MR-sim rather than a volumetric head coil for diagnostic radiological (DR) applications. In this study, we present and compare ACR MRI phantom test with flexible coils setting (RT-setting) and volumetric head coil setting (DR-setting). Methods: Two 8-channel array coils were wrapped close to an ACR MRI phantom placed on a flat couch-top in RT-setting for acquisition. ACR MRI phantom tests were conducted 10 times for each setting on a 1.5T MR-sim. Sagittal localizer (TE/TR=20/200ms), axial T1 (TE/TR=20/500ms) and T2 scans (2TEs/TR=20,80/2000ms) were acquired (NEX=1). Acqusition and image analysis were conducted following ACR guidelines. Extra 10 RT-setting acquisitions were obtained by enabling prescan normalization. Results: For RT-setting without prescan normalization, all tests passed the ACR recommended criteria but image intensity uniformity. Geometric accuracy was 147.8±0.3mm and 191.0±0.4mm. Spatial resolution was 0.9mm. Slice thickness was 5.2mm±0.1mm (T1) and 5.1±0.1mm (T2). Slice position accuracy was 1.4±0.6mm, −2.2±0.3mm (T1), and 1.5±0.2mm, −2.2±0.2mm (T2). Image uniformity was 80.6%±2.6% (T1) and 80.2%±3.1% (T2) (criteria: ≥87.5% for 1.5T). Ghosting ratio was 0.0006±0.0004. Low contrast detectability was 30.7±1.7 (T1) and 22.6±3.0 (T2). Image uniformity (91.4%±4.2% and 91.8%±4.3%) and low contrast detectability (36.5±1.4 and 31.6±2.2) of DR-setting were better than RT-setting. Prescan normalization substantially improved image uniformity to 93.4%±0.2% and 93.4%±0.3%, but slightly compromised ghosting (0.0033±0.0004) and spatial resolution (0.9mm or 1.0mm) for RT-setting. Conclusion: Flexible coils setting for HN-RT simulation scan could successfully pass ACR criteria (prescan normalization enabled) and generally achieve comparable performance to volumetric coil setting, although compromise on low contrast detectability was observed probably due to the lower signal-to-noise ratio of the flexible coils. Our results could also serve as a reference baseline of high-field MR-sim QA performance under ACR guideline.

60 APPLIED LIFE SCIENCES↗

A new generation of intelligent trainable tools for analyzing large scientific image databases

The focus of this paper is on the detection of natural, as opposed to human-made, objects. The distinction is important because, in the context of image analysis, natural objects tend to possess much greater variability in appearance than human-made objects. Hence, we shall focus primarily on the use of algorithms that 'learn by example' as the basis for image exploration. The 'learn by example' approach is potentially more generally applicable compared to model-based vision methods since domain scientists find it relatively easier to provide examples of what they are searching for versus describing a model.

Fayyad, Usama M.↗

Method and system for assigning a confidence metric for automated determination of optic disc location

A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TASLIMAGE System #2 Technical Equivalence Evaluation

In early 2017, a second TASLIMAGE system (TASL 2) was procured from Track Analysis Systems, Ltd. The new device is intended to complement the first system (TASL 1) and to provide redundancy to the original system which was acquired in 2009. The new system functions primarily the same as the earlier system, though with different X-Y stage hardware and a USB link from the camera to the host computer, both of which contribute to a reduction in CR-39 foil imaging time. The camera and image analysis software are identical between the two systems. Neutron dose calculations are performed externally and independent of the imaging system used to collect track data, relying only on the measured recoil proton track density per cm 2 for a set of known-dose CR-39 foils processed in each etch.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative Particle Analysis of Neptunium-237 Oxides: Optimization of MAMA Analysis for Modified Direct Denitration Products

The production of plutonium-238 through irradiation of neptunium-237 ( 237 Np) target materials for the use in radioisotope thermoelectric generators is paramount for continued deep space exploration. This work employs scanning electron microscopy to analyze 237 Np materials coupled with a well-developed image analysis framework (Morphological Analysis for Material Attribution, or MAMA) to determine the degree of micron-scale homogeneity in the materials. This work demonstrated how the quantification of particle characteristics can validate production materials and affirm the qualitative similarities observed in micrographs. The 237 Np oxide particle analysis determined that the materials from five production runs were quantitatively homogenous (significant at α = 0.05) in particle area, circularity, equivalent circular diameter, and ellipse aspect ratio, with two of the sampling dates having statistically significant different means for one of the four characteristics. Furthermore, these metrics not only confirm general homogeneity of the material but also expand the application of MAMA workflows to 237 Np materials, demonstrating the utility of MAMA analysis for a wider breadth of nuclear materials than previously reported. In the open literature, this study is the first time that these microanalytical techniques were applied to 237 Np materials to this degree.

MAMA↗

SU-F-R-32: Evaluation of MRI Acquisition Parameter Variations On Texture Feature Extraction Using ACR Phantom

Purpose: To investigate the sensitivity of classic texture features to variations of MRI acquisition parameters. Methods: This study was performed on American College of Radiology (ACR) MRI Accreditation Program Phantom. MR imaging was acquired on a GE 750 3T scanner with XRM explain gradient, employing a T1-weighted images (TR/TE=500/20ms) with the following parameters as the reference standard: number of signal average (NEX) = 1, matrix size = 256×256, flip angle = 90°, slice thickness = 5mm. The effect of the acquisition parameters on texture features with and without non-uniformity correction were investigated respectively, while all the other parameters were kept as reference standard. Protocol parameters were set as follows: (a). NEX = 0.5, 2 and 4; (b).Phase encoding steps = 128, 160 and 192; (c). Matrix size = 128×128, 192×192 and 512×512. 32 classic texture features were generated using the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from each image data set. Normalized range ((maximum-minimum)/mean) was calculated to determine variation among the scans with different protocol parameters. Results: For different NEX, 31 out of 32 texture features’ range are within 10%. For different phase encoding steps, 31 out of 32 texture features’ range are within 10%. For different acquisition matrix size without non-uniformity correction, 14 out of 32 texture features’ range are within 10%; for different acquisition matrix size with non-uniformity correction, 16 out of 32 texture features’ range are within 10%. Conclusion: Initial results indicated that those texture features that range within 10% are less sensitive to variations in T1-weighted MRI acquisition parameters. This might suggest that certain texture features might be more reliable to be used as potential biomarkers in MR quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

Image segmentation by iterative parallel region growing and splitting

The spatially constrained clustering (SCC) iterative parallel region-growing technique is applied to image analysis. The SCC algorithm is implemented on the massively parallel processor at NASA Goddard. Most previous region-growing approaches have the drawback that the segmentation produced depends on the order in which portions of the image are processed. The ideal solution to this problem (merging only the single most similar pair of spatially adjacent regions in the image in each iteration) becomes impractical except for very small images, even on a massively parallel computer. The SCC algorithm overcomes these problems by performing, in parallel, the best merge within each of a set of local, possibly overlapping, subimages. A region-splitting stage is also incorporated into the algorithm, but experiments show that region splitting generally does not improve segmentation results. The SCC algorithm has been tested on various imagery data, and test results for a Landsat TM image are summarized.

Tilton, James C.↗

Airborne reconnaissance XIII; Proceedings of the Meeting, San Diego, CA, Aug. 7-9, 1989

The present conference on airborne reconnaissance discusses topics in imagery exploitation, reconsystem modeling and analysis, and reconnaissance optics and electronics configurations. Attention is given to airborne minefield detection, the optimization of an IR linescanner for RPV operations, real-time display of IR linescanner data for RPVs, three-dimensional model-guided site recognition, the AMIDARS high-performance real-time display, and MMW sensor image analysis. Also discussed are reconnaissance concepts for the 3-5 micron spectral window, sensor concept development for hazard detection, a stabilization system for a large aperture camera, three-axis image stabilization with a two-axis mirror, the results of performance tests on the TOW target collimator design, and the replacement of film by electrooptic media in advanced tactical airborne reconnaissance.

Henkel, Paul A.↗

An arc control and protection system for the JET lower hybrid antenna based on an imaging system

Arcs are the potentially most dangerous events related to Lower Hybrid (LH) antenna operation. If left uncontrolled they can produce damage and cause plasma disruption by impurity influx. To address this issue an arc real time control and protection imaging system for the Joint European Torus (JET) LH antenna has been implemented. The LH system is one of the additional heating systems at JET. It comprises 24 microwave generators (klystrons, operating at 3.7 GHz) providing up to 5 MW of heating and current drive to the JET plasma. This is done through an antenna composed of an array of waveguides facing the plasma. The protection system presented here is based primarily on an imaging arc detection and real time control system. It has adapted the ITER like wall hotspot protection system using an identical CCD camera and real time image processing unit. A filter has been installed to avoid saturation and spurious system triggers caused by ionization light. The antenna is divided in 24 Regions Of Interest (ROIs) each one corresponding to one klystron. If an arc precursor is detected in a ROI, power is reduced locally with subsequent potential damage and plasma disruption avoided. The power is subsequently reinstated if, during a defined interval of time, arcing is confirmed not to be present by image analysis. This system was successfully commissioned during the restart phase and beginning of the 2013 scientific campaign. Since its installation and commissioning, arcs and related phenomena have been prevented. In this contribution we briefly describe the camera, image processing, and real time control systems. Most importantly, we demonstrate that an LH antenna arc protection system based on CCD camera imaging systems works. Examples of both controlled and uncontrolled LH arc events and their consequences are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗