Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Velocity map imaging of O-atom products from UV photodissociation of the CH{sub 2}OO Criegee intermediate

UV excitation of jet-cooled CH{sub 2}OO X{sup 1}A′ to the excited B{sup 1}A′ electronic states results in dissociation to two spin-allowed product channels: H{sub 2}CO X{sup 1}A{sub 1} + O {sup 1}D and H{sub 2}CO a{sup 3}A″ + O {sup 3}P. In this study, the higher energy H{sub 2}CO a{sup 3}A″ + O {sup 3}P channel is characterized by velocity map imaging and UV action spectroscopy, in both cases utilizing 2 + 1 resonance enhanced multiphoton ionization detection of O {sup 3}P products, which complements a prior experimental study on the lower energy H{sub 2}CO X{sup 1}A{sub 1} + O {sup 1}D channel [Lehman et al., J. Chem. Phys. 139, 141103 (2013)]. Anisotropic angular distributions indicative of rapid dissociation are obtained at 330 and 350 nm, along with broad and unstructured total kinetic energy distributions that provide insight into the internal excitation of the H{sub 2}CO a{sup 3}A″ co-fragment. A harmonic normal mode analysis points to significant vibrational excitation of the CH{sub 2} wag and C–O stretch modes of the H{sub 2}CO a{sup 3}A″ fragment upon dissociation. At each UV wavelength, the termination of the kinetic energy distribution reveals the energetic threshold for the H{sub 2}CO a{sup 3}A″ + O {sup 3}P product channel of ca. 76 kcal mol{sup −1} (378 nm) and also establishes the dissociation energy from CH{sub 2}OO X{sup 1}A′ to H{sub 2}CO X{sup 1}A{sub 1} + O{sup 1}D products of D{sub 0} ≤ 49.0 ± 0.3 kcal mol{sup −1}, which is in accord with prior theoretical studies. The threshold for the H{sub 2}CO a{sup 3}A″ + O {sup 3}P channel is also evident as a more rapid falloff on the long wavelength side of the O {sup 3}P action spectrum as compared to the previously reported UV absorption spectrum for jet-cooled CH{sub 2}OO [Beames et al., J. Am. Chem. Soc. 134, 20045 (2012)]. Modeling suggests that the O {sup 3}P yield increases uniformly from 378 to 300 nm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of full-wave simulations for mode conversion of waves in the ion cyclotron range of frequencies with phase contrast imaging in Alcator C-Mod

Mode conversion of fast waves in the ion cyclotron range of frequencies (ICRF) is known to result in current drive and flow drive under optimised conditions, which may be utilized to control plasma profiles and improve fusion plasma performance. To describe these processes accurately in a realistic toroidal geometry, numerical simulations are essential. Quantitative comparison of these simulations and the actual experimental measurements is important to validate their predictions and to evaluate their limitations. The phase contrast imaging (PCI) diagnostic has been used to directly detect the ICRF waves in the Alcator C-Mod tokamak. The measurements have been compared with full-wave simulations through a synthetic diagnostic technique. Recently, the frequency response of the PCI detector array on Alcator C-Mod was recalibrated, which greatly improved the comparison between the measurements and the simulations. In this study, mode converted waves for D-{sup 3}He and D-H plasmas with various ion species compositions were re-analyzed with the new calibration. For the minority heating cases, self-consistent electric fields and a minority ion distribution function were simulated by iterating a full-wave code and a Fokker-Planck code. The simulated mode converted wave intensity was in quite reasonable agreement with the measurements close to the antenna, but discrepancies remain for comparison at larger distances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging outside the box: Resolution enhancement in X-ray coherent diffraction imaging by extrapolation of diffraction patterns

Coherent diffraction imaging is a high-resolution imaging technique whose potential can be greatly enhanced by applying the extrapolation method presented here. We demonstrate the enhancement in resolution of a non-periodical object reconstructed from an experimental X-ray diffraction record which contains about 10% missing information, including the pixels in the center of the diffraction pattern. A diffraction pattern is extrapolated beyond the detector area and as a result, the object is reconstructed at an enhanced resolution and better agreement with experimental amplitudes is achieved. The optimal parameters for the iterative routine and the limits of the extrapolation procedure are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate [Comparison of implosion core shape observations, 10 ps dilation X-ray imager vs 100 ps gated microchannel plate]

The dilation x-ray imager (DIXI) is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10× improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method to improve the robustness of the DIXI data analysis. Furthermore, we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P 0 , P 2 and P 4 Legendre modes, and their temporal evolution/swings).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-nanosecond single line-of-sight (SLOS) x-ray imagers (invited)

A new generation of fast-gated x-ray framing cameras have been developed that are capable of capturing multiple frames along a single line-of-sight with 30 ps temporal resolution. The instruments are constructed by integrating pulse-dilation electron imaging with burst mode hybrid-complimentary metal-oxide-semiconductor sensors. Two such instruments have been developed, characterized, and fielded at the National Ignition Facility and the OMEGA laser. These instruments are particularly suited for advanced x-ray imaging applications in Inertial Confinement Fusion and High energy density experiments. Here, we discuss the system architecture and the techniques required for tuning the instruments to achieve optimal performance. Characterization results are also presented along with planned future improvements to the design.

47 OTHER INSTRUMENTATION↗

HIGH-RESOLUTION LABORATORY SPECTRA OF THE λ193 CHANNEL OF THE ATMOSPHERIC IMAGING ASSEMBLY INSTRUMENT ON BOARD SOLAR DYNAMICS OBSERVATORY

Extreme ultraviolet spectra of C, O, F, Ne, S, Ar, Fe, and Ni have been excited in an electron beam ion trap and studied with much higher resolution than available on the Solar Dynamics Observatory (SDO) in order to ascertain the spectral composition of the SDO/Atmospheric Imaging Assembly (AIA) observations. We present our findings in the wavelength range 182-200 Å, which, overall, corroborate the working models of how to interpret the SDO/AIA data. We find, however, that the inclusion of a number of additional lines might improve the data interpretation.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Six-year Image-subtraction Light Curve of SN 2010jl

SN 2010jl was a luminous Type IIn supernova (SN), detected in radio, optical, X-ray and hard X-rays. Here we report on its six-year R - and g -band light curves obtained using the Palomar Transient Factory. The light curve was generated using a pipeline based on the proper image-subtraction method and we discuss the algorithm performances. As noted before, the R -band light curve, up to about 300 days after maximum light is well described by a power-law decline with a power-law index of α ≈ -0.5. Between day 300 and day 2300 after maximum light, it is consistent with a power-law decline, with a power-law index of about α ≈ -3.4. Here, the longevity of the light curve suggests that the massive circumstellar material around the progenitor was ejected on timescales of at least tens of years prior to the progenitor explosion.

79 ASTRONOMY AND ASTROPHYSICS↗

DIRECT IMAGING OF QUASI-PERIODIC FAST PROPAGATING WAVES OF {approx}2000 km s{sup -1} IN THE LOW SOLAR CORONA BY THE SOLAR DYNAMICS OBSERVATORY ATMOSPHERIC IMAGING ASSEMBLY

Quasi-periodic propagating fast mode magnetosonic waves in the solar corona were difficult to observe in the past due to relatively low instrument cadences. We report here evidence of such waves directly imaged in EUV by the new Atmospheric Imaging Assembly instrument on board the Solar Dynamics Observatory. In the 2010 August 1 C3.2 flare/coronal mass ejection event, we find arc-shaped wave trains of 1%-5% intensity variations (lifetime {approx}200 s) that emanate near the flare kernel and propagate outward up to {approx}400 Mm along a funnel of coronal loops. Sinusoidal fits to a typical wave train indicate a phase velocity of 2200 {+-} 130 km s{sup -1}. Similar waves propagating in opposite directions are observed in closed loops between two flare ribbons. In the k-{omega} diagram of the Fourier wave power, we find a bright ridge that represents the dispersion relation and can be well fitted with a straight line passing through the origin. This k-{omega} ridge shows a broad frequency distribution with power peaks at 5.5, 14.5, and 25.1 mHz. The strongest signal at 5.5 mHz (period 181 s) temporally coincides with quasi-periodic pulsations of the flare, suggesting a common origin. The instantaneous wave energy flux of (0.1-2.6) x 10{sup 7} erg cm{sup -2} s{sup -1} estimated at the coronal base is comparable to the steady-state heating requirement of active region loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluctuation localization imaging-based fluorescence in situ hybridization (fliFISH) for accurate detection and counting of RNA copies in single cells

Here, quantitative gene expression analysis in intact single cells can be achieved using single molecule-based fluorescence in situ hybridization (smFISH). This approach relies on fluorescence intensity to distinguish between true signals, emitted from an RNA copy hybridized with multiple oligonucleotide probes, and background noise. Thus, the precision in smFISH is often compromised by partial or nonspecific probe binding and tissue autofluorescence, especially when only a small number of probes can be fitted to the target transcript. Here we provide an accurate approach for setting quantitative thresholds between true and false signals, which relies on on-off duty cycles of photoswitchable dyes. This fluctuation localization imaging-based FISH (fliFISH) uses on-time fractions (measured over a series of exposures) collected from transcripts bound to as low as 8 probes, which are distinct from on-time fractions collected from nonspecifically bound probes or autofluorescence. Using multicolor fliFISH, we identified radial gene expression patterns in mouse pancreatic islets for insulin, the transcription factor, NKX2-2 and their ratio ( Nkx2 - 2/Ins2 ). These radial patterns, showing higher values in β cells at the islet core and lower values in peripheral cells, were lost in diabetic mouse islets. In summary, fliFISH provides an accurate, quantitative approach for detecting and counting true RNA copies and rejecting false signals by their distinct on-time fractions, laying the foundation for reliable single-cell transcriptomics.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging of lateral spin valves with soft x-ray microscopy

We investigated Co/Cu lateral spin valves by means of high-resolution transmission soft x-ray microscopy with magnetic contrast that utilizes x-ray magnetic circular dichroism (XMCD). No magnetic XMCD contrast was observed at the Cu L{sub 3} absorption edge, which should directly image the spin accumulation in Cu. Although electrical transport measurements in a non-local geometry clearly detected the spin accumulation in Cu, which remained unchanged during illumination with circular polarized x-rays at the Co and Cu L{sub 3} absorption edges.

36 MATERIALS SCIENCE↗

A direct-method for imaging elemental distribution profiles with long-period x-ray standing waves.

A model-independent Fourier-inversion method for imaging elemental profiles from multilayer and total-external reflection x-ray standing wave (XSW) data is developed for the purpose of understanding the assembly of atoms, ions, and molecules at well-defined interfaces in complex environments. The direct-method formalism is derived for the case of a long-period XSW generated by low-angle specular reflection in an attenuating overlayer medium. It is validated through comparison with simulated and experimental data to directly obtain an elemental distribution contained within the overlayer. We demonstrate this formalism by extracting the one-dimensional profile of Ti normal to the surface for a TiO{sub 2}/Si/Mo trilayer deposited on a Si substrate using the Ti K{alpha} fluorescence yield measured in air and under an aqueous electrolyte. The model-independent results demonstrate reduced coherent fractions for the in situ results associated with an incoherency of the x-ray beam (which are attributed to fluorescence excitation by diffusely or incoherently scattered x-rays). The uniqueness and limitations of the approach are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive Imaging of Coherent Nuclear Motion in Isolated Molecules

Observing the motion of the nuclear wave packets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wave packet in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full width at half maximum. The method is not only sensitive to the position but also the shape of the nuclear wave packet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution extension by image summing in serial femtosecond crystallography of two-dimensional membrane-protein crystals

Previous proof-of-concept measurements on single-layer two-dimensional membrane-protein crystals performed at X-ray free-electron lasers (FELs) have demonstrated that the collection of meaningful diffraction patterns, which is not possible at synchrotrons because of radiation-damage issues, is feasible. Here, the results obtained from the analysis of a thousand single-shot, roomtemperature X-ray FEL diffraction images from two-dimensional crystals of a bacteriorhodopsin mutant are reported in detail. The high redundancy in the measurements boosts the intensity signal-to-noise ratio, so that the values of the diffracted intensities can be reliably determined down to the detector-edge resolution of 4 A ° . The results show that two-dimensional serial crystallography at X-ray FELs is a suitable method to study membrane proteins to near-atomic length scales at ambient temperature. The method presented here can be extended to pump–probe studies of optically triggered structural changes on submillisecond timescales in two-dimensional crystals, which allow functionally relevant large-scale motions that may be quenched in three-dimensional crystals.

serial crystallography, free-electron lasers, memb↗

ON THE VERIFICATION AND VALIDATION OF GEOSPATIAL IMAGE ANALYSIS ALGORITHMS

Verification and validation (V&V) of geospatial image analysis algorithms is a difficult task and is becoming increasingly important. While there are many types of image analysis algorithms, we focus on developing V&V methodologies for algorithms designed to provide textual descriptions of geospatial imagery. In this paper, we present a novel methodological basis for V&V that employs a domain-specific ontology, which provides a naming convention for a domain-bounded set of objects and a set of named relationship between these objects. We describe a validation process that proceeds through objectively comparing benchmark imagery, produced using the ontology, with algorithm results. As an example, we describe how the proposed V&V methodology would be applied to algorithms designed to provide textual descriptions of facilities

99 GENERAL AND MISCELLANEOUS↗

Use of Mass spectrometry for imaging metabolites in plants

We discuss and illustrate recent advances that have been made to image the distribution of metabolites among cells and tissues of plants using different mass spectrometry technologies. These technologies include matrix-assisted laser desorption ionization, desorption electrospray ionization, and secondary ion mass spectrometry. These are relatively new technological applications of mass spectrometry and they are providing highly spatially resolved data concerning the cellular distribution of metabolites. We discuss the advantages and limitations of each of these mass spectrometric methods, and provide a description of the technical barriers that are currently limiting the technology to the level of single-cell resolution. However, we anticipate that advances in the next few years will increase the resolving power of the technology to provide unprecedented data on the distribution of metabolites at the subcellular level, which will increase our ability to decipher new knowledge concerning the spatial organization of metabolic processes in plants.

36 MATERIALS SCIENCE↗