Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Dynamical Decoupling of Crosstalk on Superconducting Qubit Devices

Current NISQ devices are prone to errors. In order to be used for practical applications or achieve fault-tolerant thresholds, strategies to suppress error rates will be needed to maximize the potential of noisy devices. Dynamical decoupling (DD) is one such strategy for suppressing — or at least alleviating — the effects of decoherence, in which sequences of pulses are applied to qubits to decouple their interaction with the environment. Through experimental runs performed on several Rigetti quantum computing units (QPUs), we first demonstrate that DD is capable of improving coherence times for isolated qubits, as well as suppressing errors caused by the ZZ coupling between pairs of qubits. Extending this framework to cycles containing2-qubit gates, we show that DD can be inserted to decouple qubits from crosstalk occurring during neighboring 2-qubit gates, and demonstrate the efficacy of this procedure on quantum approximate optimization algorithm (QAOA) circuits. We also explore the usage of tailored DD sequences for the suppression of characterized error channels. We are grateful for support from the NASA Ames Research Center and from the DARPA ONISQ program under interagency agreement IAA 8839,Annex 114. HYH is supported by the USRA Feynman QuantumAcademy funded by the NAMS R&D Student Program and a UCHellman Fellowship. JS, ZGI and ZW are supported by USRA NASAAcademic Mission Service (NNA16BD14C).

Dynamical decoupling↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deployable Fresnel Rings

Deployable Fresnel rings (DFRs) significantly enhance the realizable gain of an antenna. This innovation is intended to be used in combination with another antenna element, as the DFR itself acts as a focusing or microwave lens element for a primary antenna. This method is completely passive, and is also completely wireless in that it requires neither a cable, nor a connector from the antenna port of the primary antenna to the DFR. The technology improves upon the previous NASA technology called a Tri-Sector Deployable Array Antenna in at least three critical aspects. In contrast to the previous technology, this innovation requires no connector, cable, or other physical interface to the primary communication radio or sensor device. The achievable improvement in terms of antenna gain is significantly higher than has been achieved with the previous technology. Also, where previous embodiments of the Tri-Sector antenna have been constructed with combinations of conventional (e.g., printed circuit board) and conductive fabric materials, this innovation is realized using only conductive and non-conductive fabric (i.e., "e-textile") materials, with the possible exception of a spring-like deployment ring. Conceptually, a DFR operates by canceling the out-of-phase radiation at a plane by insertion of a conducting ring or rings of a specific size and distance from the source antenna, defined by Fresnel zones. Design of DFRs follow similar procedures to those outlined for conventional Fresnel zone rings. Gain enhancement using a single ring is verified experimentally and through computational simulation. The experimental test setup involves a microstrip patch antenna that is directly behind a single-ring DFR and is radiating towards a second microstrip patch antenna. The first patch antenna and DFR are shown. At 2.42 GHz, the DFR improves the transmit antenna gain by 8.6 dB, as shown in Figure 2, relative to the wireless link without the DFR. A figure illustrates the relative strength of power coupling between the first and second microstrip antennas with and without the DFR. Typically, a DFR is designed for use at a particular frequency; however, testing of a DFR indicated a relatively wide operational bandwidth of approximately 8.2%. Wider bandwidth operation and multi-band operation are anticipated by extending the known art of conventional Fresnel rings to the DFRs. Increasing the number of rings used to construct a DFR antenna increases the gain, with the upper bound limited often by the largest practical dimensions that can be tolerated for a given application. The maximum theoretical improvement in gain for a single ring is 9.5 dB. Experimental results are within 0.9 dB of this theoretical value. Adding rings increases gain, and theoretically, improvements of 10 to 13 dB above that of the primary antenna gain can be achieved with two- and three-ring versions.

Kennedy, Timothy F.↗

EPID-guided 3D dose verification of lung SBRT

Purpose: To investigate the feasibility of utilizing tumor tracks from electronic portal imaging device (EPID) images taken during treatment to verify the delivered dose. Methods: The proposed method is based on a computation of the delivered fluence by utilizing the planned fluence and the tumor motion track for each field. A phantom study was designed to assess the feasibility of the method. The CIRS dynamic thorax phantom was utilized with a realistic soft resin tumor, modeled after a real patient tumor. The dose calculated with the proposed method was compared to direct measurements taken with 15 metal oxide semiconductor field effect transistors (MOSFETs) inserted in small fissures made in the tumor model. The phantom was irradiated with the tumor static and moved with different range of motions and setup errors. EPID images were recorded throughout all deliveries and the tumor model was tracked post-treatment with in-house developed software. The planned fluence for each field was convolved with the tumor motion tracks to obtain the delivered fluence. Utilizing the delivered fluence from each field, the delivered dose was calculated. The estimated delivered dose was compared to the dose directly measured with the MOSFETs. The feasibility of the proposed method was also demonstrated on a real lung cancer patient, treated with stereotactic body radiotherapy. Results: The calculation of delivered dose with the delivered fluence method was in good agreement with the MOSFET measurements, with average differences ranging from 0.8% to 8.3% depending on the proximity of a dose gradient. For the patient treatment, the planned and delivered dose volume histograms were compared and verified the overall good coverage of the target volume. Conclusions: The delivered fluence method was applied successfully on phantom and clinical data and its accuracy was evaluated. Verifying each treatment fraction may enable correction strategies that can be applied during the course of treatment to ensure the desired dose coverage.

60 APPLIED LIFE SCIENCES↗

SU-G-206-07: Dual-Energy CT Inter- and Intra-Scanner Variability Within One Make and Model

Purpose: It can be logistically quite difficult to scan patients on the same exact device for their repeat visits in multi-scanner facilities. The reliability between dual-energy CT scanners’ quantitative results is not known, nor is their individual repeatability. Therefore, we evaluated inter- and intra-scanner variability with respect to several key clinical quantitative metrics specific to dual-energy CT. Methods: Eleven identical GE HD-750 CT scanners in a busy clinical environment were used to perform dual-energy (DE) CT scans of a large elliptical quality control (QC) phantom (Gammex, Inc.; Middleton, WI) which contains many standard insert materials. The DE-QC phantom was scanned bi-weekly during 2016; 3 to 4 scans were obtained from each scanner (a total of 35 data sets were used for analysis). Iodine accuracy for the 2mg/ml, 5mg/ml and 15mg/ml rods (from the Iodine(Water) image set) and soft tissue HU (40 HU based on NIST constants) from the 50keV data set were used to assess inter- and intra-scanner variability (standard deviation). Results: Intra-scanner variability average for 2mg/ml Iodine was 0.10 mg/ml (range 0.05–0.15 mg/ml), for 5mg/ml Iodine was 0.12 mg/ml (range 0.07–0.16 mg/ml), for 15 mg/ml Iodine was 0.25 mg/ml (range 0.16–0.37 mg/ml), and for the soft tissue inserts was 2.1 HU (range 1.8–2.6 HU). Inter-scanner variability average for 2mg/ml Iodine was 0.16 mg/ml (range 0.11–0.19 mg/ml), for 5mg/ml Iodine was 0.18 mg/ml (range 0.11–0.22 mg/ml), for 15 mg/ml Iodine was 0.35 mg/ml (range 0.23–0.44 mg/ml), and for the soft tissue inserts was 3.8 HU (range 3.1–4.5 HU). Conclusion: Intra-scanner variability for the iodine and soft tissue inserts averaged 3.1% and 5.2% respectively, and inter-scanner variability for these regions analyzed averaged 5.0% and 9.5%, respectively. Future work will include determination of smallest measurable change and acceptable limits for DE-CT scanner variability over longer time intervals. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Active Hydrazine Vapor Sampler (AHVS)

The Active Hydrazine Vapor Sampler (AHVS) was developed to detect vapors of hydrazine (HZ) and monomethylhydrazine (MMH) in air at parts-per-billion (ppb) concentration levels. The sampler consists of a commercial personal pump that draws ambient air through paper tape treated with vanillin (4-hydroxy-3-methoxybenzaldehyde). The paper tape is sandwiched in a thin cardboard housing inserted in one of the two specially designed holders to facilitate sampling. Contaminated air reacts with vanillin to develop a yellow color. The density of the color is proportional to the concentration of HZ or MMH. The AHVS can detect 10 ppb in less than 5 minutes. The sampler is easy to use, low cost, and intrinsically safe and contains no toxic material. It is most beneficial for use in locations with no laboratory capabilities for instrumentation calibration. This paper reviews the development, laboratory test, and field test of the device.

Young, Rebecca C.↗

Correlation Between Material Properties of Ferroelectric Thin Films and Design Parameters for Microwave Device Applications: Modeling Examples and Experimental Verification

The application of thin ferroelectric films for frequency and phase agile components is the topic of interest of many research groups worldwide. Consequently, proof-of-concepts (POC) of different tunable microwave components using either (HTS, metal)/ferroelectric thin film/dielectric heterostructures or (thick, thin) film "flip-chip" technology have been reported. Either as ferroelectric thin film characterization tools or from the point of view of circuit implementation approach, both configurations have their respective advantages and limitations. However, we believe that because of the progress made so far using the heterostructure (i.e., multilayer) approach, and due to its intrinsic features such as planar configuration and monolithic integration, a study on the correlation of circuit geometry aspects and ferroelectric material properties could accelerate the insertion of this technology into working systems. In this paper, we will discuss our study performed on circuits based on microstrip lines at frequencies above 10 GHz, where the multilayer configuration offers greater ease of insertion due to circuit's size reduction. Modeled results of relevant circuit parameters such as the characteristic impedance, effective dielectric constant, and attenuation as a function of ferroelectric film's dielectric constant, tans, and thickness, will be presented for SrTiO3 and Ba(x)Sr(1-x)TiO3 ferroelectric films. A comparison between the modeled and experimental data for some of these parameters will be presented.

Miranda, Felix A.↗

Pluto Hop, Skip, and Jump

This is the Final Report from Global Aerospace Corporation on this NIAC effort (Grant Nos.: NNX17AJ71G and 80NSSC18K0062) to develop the Pluto Hop, Skip, and Jump mission concept. We sought out to establish the feasibility of using a large inflatable drag device to decelerate and land on Pluto from interplanetary speed (~14 km/s) using only the Pluto atmosphere and just a few kilograms of propellant. The design and analysis efforts in Phase I indicated that this is feasible. Aerodynamic heating and loads were found to be orders of magnitude less than typical planetary entries due to the ultra-low ballistic coefficient craft and the low density and large scale height of the Pluto atmosphere. The deceleration system is capable of delivering a 200-kg lander-hopper to the surface or inserting an orbiter of a similar mass using aerocapture. Mission analysis work led to a reference mission with Earth launch in 2029, Jupiter assist in 2030, and Pluto arrival in 2040.

Goldman, Benjamin↗

Carbon Nanotube Switches for Communication and Memory Applications

Lateral CNT Switches: a) dc CNT switches were demonstrated to operate at low voltages, low powers and high speeds. b) RF simulations of switch in series configuration with metallized tube yielded good RF performance 1) Isolation simulated to be approx. 20 dB at 100 GHz. 2) Insertion loss simulated to be < 0.5 dB at 100 GHz. Vertical CNT Switches: a) Thermal CVD was used to mechanically constrain tubes in nanopockets; tubes not self-supporting. b) Demonstrated growth of vertically aligned arrays and single-few MWNTs using dc PECVD with Ni catalyst using optical lithography.

memory devices↗

Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for batch fabrication of cold cathode vacuum switch tubes

Methods are disclosed for batch fabrication of vacuum switch tubes that reduce manufacturing costs and improve tube to tube uniformity. The disclosed methods comprise creating a stacked assembly of layers containing a plurality of adjacently spaced switch tube sub-assemblies aligned and registered through common layers. The layers include trigger electrode layer, cathode layer including a metallic support/contact with graphite cathode inserts, trigger probe sub-assembly layer, ceramic (e.g. tube body) insulator layer, and metallic anode sub-assembly layer. Braze alloy layers are incorporated into the stacked assembly of layers, and can include active metal braze alloys or direct braze alloys, to eliminate costs associated with traditional metallization of the ceramic insulator layers. The entire stacked assembly is then heated to braze/join/bond the stack-up into a cohesive body, after which individual switch tubes are singulated by methods such as sawing. The inventive methods provide for simultaneously fabricating a plurality of devices as opposed to traditional methods that rely on skilled craftsman to essentially hand build individual devices.

36 MATERIALS SCIENCE↗

Human Flight to Lunar and Beyond - Re-Learning Operations Paradigms

For the first time since the Apollo era, NASA is planning on sending astronauts on flights beyond LEO. The Human Space Flight (HSF) program started with a successful initial flight in Earth orbit, in December 2014. The program will continue with two Exploration Missions (EM): EM-1 will be unmanned and EM-2, carrying astronauts, will follow. NASA established a multi-center team to address the communications, and related tacking/navigation needs. This paper will focus on the lessons learned by the team designing the architecture and operations for the missions. Many of these Beyond Earth Orbit lessons had to be re-learned, as the HSF program has operated for many years in Earth orbit. Unlike the Apollo missions that were largely tracked by a dedicated ground network, the HSF planned missions will be tracked (at distances beyond GEO) by the DSN, a network that mostly serves robotic missions. There have been surprising challenges to the DSN as unique modern human spaceflight needs stretch the experience base beyond that of tracking robotic missions in deep space. Close interaction between the DSN and the HSF community to understand the unique needs (e.g. 2-way voice) resulted in a Concept of Operations (ConOps) that leverages both the deep space robotic and the Human LEO experiences. Several examples will be used to highlight the unique challenges the team faced in establishing the communications and tracking capabilities for HSF missions beyond Earth Orbit, including: Navigation. At LEO, HSF missions can rely on GPS devices for orbit determination. For Lunar-and-beyond HSF missions, techniques such as precision 2-way and 3-way Doppler and ranging, Delta-Difference-of-range, and eventually possibly on-board navigation will be used. At the same time, HSF presents a challenge to navigators, beyond those presented by robotic missions - navigating a dynamic/"noisy" spacecraft. Impact of latency - the delay associated with Round-Trip-Light-Time (RTLT). Imagine trying to have a 2-way discussion (audio or video) with an astronaut, with a 2-3 sec or more delay inserted (for lunar distances) or 20 minutes delay (for Mars distances). Balanced communications link. For robotic missions, there has been a heavy emphasis on higher downlink data rates, e.g. bringing back science data. Higher uplink data rates were of secondary importance, as uplink was used only to send commands (and occasionally small files) to the spacecraft. The ratio of downlink-to-uplink data rates was often 10:1 or more. For HSF, a continuous forward link is established and rates for uplink and downlink are more similar.

Kenny, Edward (Ted)↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

Racetrack resonator as a loss measurement platform for photonic components

This work represents the first complete analysis of the use of a racetrack resonator to measure the insertion loss of efficient, compact photonic components. Beginning with an in-depth analysis of potential error sources and a discussion of the calibration procedure, the technique is used to estimate the insertion loss of waveguide width tapers of varying geometry with a resulting 95% confidence interval of 0.007 dB. Furthermore, the work concludes with a performance comparison of the analyzed tapers with results presented for four taper profiles and three taper lengths.

47 OTHER INSTRUMENTATION↗

Mercury ion thruster research, 1978

The effects of 8 cm thruster main and neutralizer cathode operating conditions on cathode orifice plate temperatures were studied. The effects of cathode operating conditions on insert temperature profiles and keeper voltages are presented for three different types of inserts. The bulk of the emission current is generally observed to come from the downstream end of the insert rather than from the cathode orifice plate. Results of a test in which the screen grid plasma sheath of a thruster was probed as the beam current was varied are shown. Grid performance obtained with a grid machined from glass ceramic is discussed. The effects of copper and nitrogen impurities on the sputtering rates of thruster materials are measured experimentally and a model describing the rate of nitrogen chemisorption on materials in either the beam or the discharge chamber is presented. The results of optimization of a radial field thruster design are presented. Performance of this device is shown to be comparable to that of a divergent field thruster and efficient operation with the screen grid biased to floating potential, where its susceptibility to sputter erosion damage is reduced, is demonstrated.

Wilbur, P. J.↗

The fast reciprocating magnetic probe system on the J-TEXT tokamak

The fast reciprocating magnetic probe (FRMP) system is newly developed on the Joint Texas Experimental Tokamak (J-TEXT) to measure the local magnetic fluctuations at the plasma edge. The magnetic probe array in the FRMP consists of four 2-dimensional magnetic probes arranged at different radial locations to detect local poloidal and radial magnetic fields. These probes are protected by a graphite and boron nitride casing to improve the frequency response of each probe; they are mounted on the head of a movable rod, which is oriented along radial direction at the top of the torus. In the experiments, multiple core diagnostics show that the insertion of the FRMP has little impact on the equilibrium of the plasma. Local magnetic fluctuations inside the last closed flux surface are successfully measured by the FRMP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report

AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump to more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TDRS Ku band gateway

The Wideband Transport Frame Formatter (WTFF) is the tracking and data relay satellite (TDRS) ku-band return link gateway. The WTFF system is a multiplexing device developed to process and downlink the high rate data generated by a wide variety of users. The WTFF is designed to frame and format high data rate user channels into transport frames and multiplex according to a predefined schedule into two bit streams that are compatible with TDRS Ku I and Q band service. The combined data rate will be 300 Mbps. The WTFF will service up to eight input channels generating data in the range of 10 to 150 Mbps. In addition to these input channels, audio data will be accepted by the WTFF system and inserted in the downlink. A second function of the WTFF is to provide telecommunication coding as assigned to each virtual channel to ensure a given quality of service.

Collins, Cynthia↗