Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

How Small Can We Go? Evaluating Survival, Tag Retention, and Growth of Juvenile Chinook Salmon Implanted with a New Acoustic Microtag

Abstract Recently, an acoustic microtag, called the Eel–Lamprey Acoustic Tag (ELAT), was developed for use in juvenile American Eel Anguilla rostrata and Pacific Lamprey Entosphenus tridentatus. The ELAT (12.0 × 2.0 mm; 0.088 g in air) has the potential to be used to study other small-bodied fishes. In this pilot study, juvenile Chinook Salmon Oncorhynchus tshawytscha 52–99 mm fork length (FL) were surgically implanted with an ELAT (n = 99) or remained untagged (control; n = 101). Fish were held for 30 d to evaluate survival, tag retention, and growth. Survival did not differ significantly between control (n = 98 or 97.0%) and tagged fish (n = 95 or 95.9%). Logistic regression analysis suggested that survival was influenced by initial FL and tag burden. Mortalities only occurred in tagged fish with initial FLs of ≤65 mm (FL range = 57–65 mm; tag burdens = 3.8–5.9%). However, a tagged fish with an initial FL of 62 mm or an initial tag burden of 4.1% (FL range = 58–64 mm) was predicted to have a 90% chance of survival, and the smallest fish that survived the study was 54 mm FL (1.8 g; tag burden = 4.9%). Tag retention was high (99%), with only one fish expelling an ELAT during the study. Control fish grew slightly larger than the tagged individuals, but differences in final pooled FLs and weight gains were not significant. Our results demonstrate the successful surgical implantation of the ELAT into Chinook Salmon as small as 54 mm FL (1.8 g).

59 BASIC BIOLOGICAL SCIENCES↗

Rapid kVp switching dual-energy CT in the assessment of urolithiasis in patients with large body habitus: preliminary observations on image quality and stone characterization

Purpose: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. Materials and methods: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23–83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1–4) and characterization of stone composition (reference standard: crystallography). Results: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91–154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2–22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2–22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6–6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. Conclusion: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters <18 mm and 30 (26%) patients had one or more CIA diameters >18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs {>=}18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs {>=}18 mm (p = 0.232). One-year freedom from IRSI was 92% {+-} 3% and 84% {+-} 9% for the <18-mm and {>=}18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overexpression of Robo2 causes defects in the recruitment of metanephric mesenchymal cells and ureteric bud branching morphogenesis

Highlights: Black-Right-Pointing-Pointer Overexpression of Robo2 caused reduced UB branching and glomerular number. Black-Right-Pointing-Pointer Fewer MM cells surrounding the UB after overexpression of Robo2 in vitro. Black-Right-Pointing-Pointer No abnormal Epithelial Morphology of UB or apoptosis of mm cells in the kidney. Black-Right-Pointing-Pointer Overexpression of Robo2 affected MM cells migration and caused UB deficit. Black-Right-Pointing-Pointer The reduced glomerular number can also be caused by fewer MM cells. -- Abstract: Roundabout 2 (Robo2) is a member of the membrane protein receptor family. The chemorepulsive effect of Slit2-Robo2 signaling plays vital roles in nervous system development and neuron migration. Slit2-Robo2 signaling is also important for maintaining the normal morphogenesis of the kidney and urinary collecting system, especially for the branching of the ureteric bud (UB) at the proper site. Slit2 or Robo2 mouse mutants exhibit multilobular kidneys, multiple ureters, and dilatation of the ureter, renal pelvis, and collecting duct system, which lead to vesicoureteral reflux. To understand the effect of Robo2 on kidney development, we used microinjection and electroporation to overexpress GFP-Robo2 in an in vitro embryonic kidney model. Our results show reduced UB branching and decreased glomerular number after in vitro Robo2 overexpression in the embryonic kidneys. We found fewer metanephric mesenchymal (MM) cells surrounding the UB but no abnormal morphology in the branching epithelial UB. Meanwhile, no significant change in MM proliferation or apoptosis was observed. These findings indicate that Robo2 is involved in the development of embryonic kidneys and that the normal expression of Robo2 can help maintain proper UB branching and glomerular morphogenesis. Overexpression of Robo2 leads to reduced UB branching caused by fewer surrounding MM cells, but MM cell apoptosis is not involved in this effect. Our study demonstrates that overexpression of Robo2 by microinjection in embryonic kidneys is an effective approach to study the function of Robo2.

60 APPLIED LIFE SCIENCES↗

Expression profile and function of Wnt signaling mechanisms in malignant mesothelioma cells

Highlights: •Expression profile of Wnt pathway related genes in mesothelioma cells. •Differential expression of key Wnt pathway molecules and regulators. •Wnt3a stimulated mesothelioma growth whereas sFRP4 was inhibitory. •Targeting β-Catenin can sensitise mesothelioma cells to cytotoxic drugs. -- Abstract: Malignant mesothelioma (MM) is an uncommon and particularly aggressive cancer associated with asbestos exposure, which currently presents an intractable clinical challenge. Wnt signaling has been reported to play a role in the neoplastic properties of mesothelioma cells but has not been investigated in detail in this cancer. We surveyed expression of Wnts, their receptors, and other key molecules in this pathway in well established in vitro mesothelioma models in comparison with primary mesothelial cultures. We also tested the biological response of MM cell lines to exogenous Wnt and secreted regulators, as well as targeting β-catenin. We detected frequent expression of Wnt3 and Wnt5a, as well as Fzd 2, 4 and 6. The mRNA of Wnt4, Fzd3, sFRP4, APC and axin2 were downregulated in MM relative to mesothelial cells while LEF1 was overexpressed in MM. Functionally, we observed that Wnt3a stimulated MM proliferation while sFRP4 was inhibitory. Furthermore, directly targeting β-catenin expression could sensitise MM cells to cytotoxic drugs. These results provide evidence for altered expression of a number of Wnt/Fzd signaling molecules in MM. Modulation of Wnt signaling in MM may prove a means of targeting proliferation and drug resistance in this cancer.

60 APPLIED LIFE SCIENCES↗

Differential concentration-specific effects of caffeine on cell viability, oxidative stress, and cell cycle in pulmonary oxygen toxicity in vitro

Highlights: • Caffeine at 0.05 mM decreases oxidative stress in hyperoxia. • Caffeine at 1 mM decreases cell viability, increases oxidative stress in hyperoxia. • Caffeine at 1 but not 0.05 mM, abrogates hyperoxia-induced G2/M arrest. - Abstract: Caffeine is used to prevent bronchopulmonary dysplasia (BPD) in premature neonates. Hyperoxia contributes to the development of BPD, inhibits cell proliferation and decreases cell survival. The mechanisms responsible for the protective effect of caffeine in pulmonary oxygen toxicity remain largely unknown. A549 and MLE 12 pulmonary epithelial cells were exposed to hyperoxia or maintained in room air, in the presence of different concentrations (0, 0.05, 0.1 and 1 mM) of caffeine. Caffeine had a differential concentration-specific effect on cell cycle progression, oxidative stress and viability, with 1 mM concentration being deleterious and 0.05 mM being protective. Reactive oxygen species (ROS) generation during hyperoxia was modulated by caffeine in a similar concentration-specific manner. Caffeine at 1 mM, but not at the 0.05 mM concentration decreased the G2 arrest in these cells. Taken together this study shows the novel funding that caffeine has a concentration-specific effect on cell cycle regulation, ROS generation, and cell survival in hyperoxic conditions.

60 APPLIED LIFE SCIENCES↗

Characterization of γδ regulatory T cells from peripheral blood in patients with multiple myeloma

γδ regulatory T cells are able to inhibit the activation and function of T cells involved in antigen-specific immune responses. This study aimed to investigate the potential role of γδ regulatory T cells in inhibiting anti-tumor immune responses in patients diagnosed as multiple myeloma (MM). We measured the levels of γδ T cells, the distribution and clonally amplified TCR Vγ and VδT cells in peripheral blood of healthy donors, patients recently diagnosed with MM, and MM patients in remission cohorts. In addition, we evaluated the ability of γδ regulatory T cells to inhibit the proliferation of CD4+CD25- T cells and detected the expression of immunoregulatory-associated molecules. We found that the levels of γδ regulatory T cells from the peripheral blood in patients of MM were significantly higher than those in healthy donors. Comparison of γδT regulatory cells function in MM and healthy donors showed similarly inhibitory effects on the proliferation of T cells. Additionally, TLR8 expression level increased significantly in MM patients compared to healthy donors, while the expression levels of Foxp3, CD25, CTLA4, GITR, GATA3 and Tbet in MM patients and healthy donors showed no significant difference. Taken together, our study reveals the potential role of γδ regulatory T cells in inhibiting anti-tumor immune responses in MM patients.

60 APPLIED LIFE SCIENCES↗

Fiber orientation and porosity in large-format extrusion process: The role of processing parameters

Controlling fiber orientation and porosity in short-fiber thermoplastic composites is important for enhancing mechanical, electrical and thermal properties in large-format additive manufacturing. This study employs a factorial design of experiments (DoE) to assess the effects of nozzle diameter (5.08 mm–10.16 mm), temperature (230–250 °C), and extruder screw speed (150–280 rpm) on flow rate, shear rate, porosity, fiber orientation, fiber length and tensile strength in 20 % carbon fiber-filled acrylonitrile butadiene styrene. ANOVA results show that screw speed significantly impacts flow rate, while nozzle diameter and temperature have lesser effects. Shear rate increases with smaller nozzles and higher speeds. Porosity decreases from 5.58 % with a 10.16 mm nozzle to 3.11 % with a 5.08 mm nozzle at 150 rpm due to increased shear rates, which induce shear thinning, reducing viscosity and facilitating gas escape. Larger nozzles (10.16 mm) produce larger, more heterogeneous pores, while smaller nozzles (5.08 mm) yield smaller, uniform pores. Beads produced with the 5.08 mm nozzle exhibit longer fiber lengths due to reduced residence time, lower shear stress, and better alignment. Fiber orientation improves with smaller nozzles due to higher shear rates but decreases with higher screw speeds (280 rpm) due to shorter residence times. The highest fiber alignment (A xx ∼ 0.65) and low porosity (∼3%) were achieved with a 5.08 mm nozzle at 150 rpm, while equivalent additive manufacturing-compression molding samples exhibited better tensile strength (∼93 MPa) under these conditions. In conclusion, these findings emphasize the importance of optimizing processing parameters to enhance fiber alignment and reduce porosity for improved mechanical performance.

Design of experiments↗

Quantification of Prostate and Seminal Vesicle Interfraction Variation During IMRT

Purpose: To quantify the interfraction variability in prostate and seminal vesicle (SV) positions during a course of intensity-modulated radiotherapy (IMRT) using an integrated computed tomography (CT)-linear accelerator system and to assess the impact of rectal and bladder volume changes. Methods and Materials: We studied 15 patients who had undergone IMRT for prostate carcinoma. Patients had one pretreatment planning CT scan followed by three in-room CT scans per week using a CT-on-rails system. The prostate, bladder, rectum, and pelvic bony anatomy were contoured in 369 CT scans. Using the planning CT scan as a reference, the volumetric and positional changes were analyzed in the subsequent CT scans. Results: For all 15 patients, the mean systematic internal prostate and SV variation was 0.1 {+-} 4.1 mm and 1.2 {+-} 7.3 mm in the anteroposterior axis, -0.5 {+-} 2.9 mm and -0.7 {+-} 4.5 mm in the superoinferior axis, and 0.2 {+-} 0.9 mm and -0.9 {+-} 1.9 mm in the lateral axis, respectively. The mean magnitude of the three-dimensional displacement vector was 4.6 {+-} 3.5 mm for the prostate and 7.6 {+-} 4.7 mm for the SVs. The rectal and bladder volume changes during treatment correlated with the anterior and superior displacement of the prostate and SVs. Conclusion: The dominant prostate and SV variations occurred in the anteroposterior and superoinferior directions. The systematic prostate and SV variation between the treatment planning CT and daily therapy as a result of the rectal and bladder volume changes emphasizes the need for daily directed target localization and/or immobilization techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four-Dimensional Cone Beam CT Guidance

Purpose: To quantify the localization accuracy and intrafraction stability of lung cancer patients treated with frameless, four-dimensional (4D) cone beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) and to calculate and validate planning target volume (PTV) margins to account for the residual geometric uncertainties. Materials and Methods: Sixty-five patients with small peripheral lung tumors were treated with SBRT without a body frame to 54 Gy in three fractions. For each fraction, three 4D-CBCT scans were acquired: before treatment to measure and correct the time-weighted mean tumor position, after correction to validate the correction applied, and after treatment to estimate the intrafraction stability. Patient-specific PTV margins were computed and subsequently validated using Monte Carlo error simulations. Results: Systematic tumor localization inaccuracies (1 SD) were 0.8, 0.8, and 0.9 mm for the left-right, craniocaudal, and anteroposterior direction, respectively. Random localization inaccuracies were 1.1, 1.1, and 1.4 mm. Baseline variations were 1.8, 2.9, and 3.0 mm (systematic) and 1.1, 1.5, and 2.0 mm (random), indicating the importance of image guidance. Intrafraction stability of the target was 1.2, 1.2, and 1.8 mm (systematic) and 1.3, 1.5, and 1.8 mm (random). Monte Carlo error simulations showed that patient-specific PTV margins (5.8-10.5 mm) were adequate for 94% of the evaluated cases (2-28 mm peak-to-peak breathing amplitude). Conclusions: Frameless SBRT can be safely administered using 4D-CBCT guidance. Even with considerable breathing motion, the PTV margins can safely be kept small, allowing patients with larger tumors to benefit from the advantages of SBRT. In case bony anatomy would be used as a surrogate for tumor position, considerably larger PTV margins would be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Analysis of Extracapsular Extension of Metastatic Lymph Nodes and its Significance in Radiotherapy Planning in Head and Neck Squamous Cell Carcinoma

Purpose: We performed a histopathologic analysis to assess the extent of the extracapsular extension (ECE) beyond the capsule of metastatic lymph nodes (LN) in head and neck cancer to determine appropriate clinical target volume (CTV) expansions. Methods and Materials: All tumor-positive LN of 98 patients who underwent a neck dissection with evidence of ECE in at least one LN were analyzed by a single pathologist. The largest diameters of all LN, and in the case of ECE, the maximal linear distance, from the capsule to the farthest extent of tumor or tumoral reaction were recorded. Results: A total of 231 LN with ECE and 200 tumor-positive LN without ECE were analyzed. The incidence of ECE was associated with larger LN size (p < 0.001). Of all tumor-positive LN with a diameter of < 10 mm or < 5 mm, 105/220 (48%) nodes or 17/59 (29%) nodes, respectively, showed evidence of ECE. The mean and median extent values of ECE were 2 and 1 mm (range, 1-10 mm) and the ECE was <= 5 mm in 97% and <= 3 mm in 91% of the LN, respectively. Overall, the extent of ECE was significantly correlated with larger LN size (Spearman's correlation coefficient = 0.21; p = 0.001). Conclusions: The incidence of ECE is associated with larger LN size. However, ECE is found in a substantial number of LN with a diameter of < 10 mm. The use of 10-mm CTV margins around the gross tumor volume seems appropriate to account for ECE in radiotherapy planning of head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility Study for Markerless Tracking of Lung Tumors in Stereotactic Body Radiotherapy

Purpose: To evaluate the feasibility and accuracy of a method for markerless tracking of lung tumors in electronic portal imaging device (EPID) movies and to analyze intra- and interfractional variations in tumor motion. Methods and Materials: EPID movies were acquired during stereotactic body radiotherapy (SBRT) given to 40 patients with 49 pulmonary targets and retrospectively analyzed. Tumor visibility and tracking accuracy were determined by three observers. Tumor motion of 30 targets was analyzed in detail via four-dimensional computed tomography (4DCT) and EPID in the superior-inferior direction for intra- and interfractional variations. Results: Tumor visibility was sufficient for markerless tracking in 47% of the EPID movies. Tumor size and visibility in the DRR were correlated with visibility in the EPID images. The difference between automatic and manual tracking was a maximum of 2 mm for 98.3% in the x direction and 89.4% in the y direction. Motion amplitudes in 4DCT images (range, 0.7-17.9 mm; median, 4.9 mm) were closely correlated with amplitudes in the EPID movies. Intrafractional and interfractional variability of tumor motion amplitude were of similar magnitude: 1 mm on average to a maximum of 4 mm. A change in moving average of more than {+-}1 mm, {+-}2 mm, and {+-}4 mm were observed in 47.1%, 17.1%, and 4.5% of treatment time for all trajectories, respectively. Mean tumor velocity was 3.4 mm/sec, to a maximum 61 mm/sec. Conclusions: Tracking of pulmonary tumors in EPID images without implanted markers was feasible in 47% of all treatment beams. 4DCT is representative of the evaluation of mean breathing motion on average, but larger deviations occurred in target motion between treatment planning and delivery effort a monitoring during delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer

Purpose: The aim of this study was to characterize the levels of artifacts and distortions of titanium applicators on 3.0-Tesla magnetic resonance imaging (MRI). Methods and Materials: Fletcher-Suit-Delclos-style tandem and ovoids (T and O) and tandem and ring applicator (T and R) were examined. The quality assurance (QA) phantoms for each applicator were designed and filled with copper sulphate solution (1.5 g/l). The artifacts were quantified with the registration of corresponding computed tomography (CT) images. A favorable MR sequence was searched in terms of artifacts. Using the sequence, the artifacts were determined. The geometric distortions induced by the applicators were quantified through each registration of CT and MRI without applicators. The artifacts of T and O were also evaluated on in vivo MRI datasets of 5 patients. Results: T1-weighted MRI with 1-mm slice thickness was found as a favorable MR sequence. Applying the sequence, the artifacts at the tandem tip of T and O and T and R were determined as 1.5 {+-} 0.5 mm in a superior direction in phantom studies. In the ovoids of T and O, we found artifacts less than 1.5 {+-} 0.5 mm. The artifacts of a T and O tandem in vivo were found as less than 2.6 {+-} 1.3 mm on T1-weighted MRI, whereas less than 6.9 {+-} 3.4 mm on T2-weighted MRI. No more than 1.2 {+-} 0.6 mm (3.0 {+-} 1.5 mm) of distortions, due to a titanium applicator, were measured on T1-weighted MRI (T2-). Conclusion: In 3.0-Tesla MRI, we found the artifact widths at the tip of tandem were less than 1.5 {+-} 0.5 mm for both T and O and T and R when using T1-weighted MRI in phantom studies. However, exclusive 3.0-Tesla MRI-guided brachytherapy planning with a titanium applicator should be cautiously implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 {+-} 1.8 mm, 0.1 {+-} 1.9 mm, and 0.01 {+-} 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 {+-} 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior-posterior direction, with systematic ( N-Ary-Summation ) and random ({sigma}) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%{+-}19.8% of treatment time. Real-time tracking reduced prostate motion to N-Ary-Summation =0.01 mm and {sigma} = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%{+-}4.6% and 99.7%{+-}0.4% of the time, respectively. Without real-time tracking, pass rates based on a {gamma} index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images

Purpose: To verify the geometric accuracy of gated RapidArc treatment using kV images acquired during dose delivery. Methods and Materials: Twenty patients were treated using the gated RapidArc technique with a Varian TrueBeam STx linear accelerator. One to 7 metallic fiducial markers were implanted inside or near the tumor target before treatment simulation. For patient setup and treatment verification purposes, the internal target volume (ITV) was created, corresponding to each implanted marker. The gating signal was generated from the Real-time Position Management (RPM) system. At the beginning of each fraction, individualized respiratory gating amplitude thresholds were set based on fluoroscopic image guidance. During the treatment, we acquired kV images immediately before MV beam-on at every breathing cycle, using the on-board imaging system. After the treatment, all implanted markers were detected, and their 3-dimensional (3D) positions in the patient were estimated using software developed in-house. The distance from the marker to the corresponding ITV was calculated for each patient by averaging over all markers and all fractions. Results: The average 3D distance between the markers and their ITVs was 0.8 {+-} 0.5 mm (range, 0-1.7 mm) and was 2.1 {+-} 1.2 mm at the 95th percentile (range, 0-3.8 mm). On average, a left-right margin of 0.6 mm, an anterior-posterior margin of 0.8 mm, and a superior-inferior margin of 1.5 mm is required to account for 95% of the intrafraction uncertainty in RPM-based RapidArc gating. Conclusion: To our knowledge, this is the first clinical report of intrafraction verification of respiration-gated RapidArc treatment in stereotactic ablative radiation therapy. For some patients, the markers deviated significantly from the ITV by more than 2 mm at the beginning of the MV beam-on. This emphasizes the need for gating techniques with beam-on/-off controlled directly by the actual position of the tumor target instead of external surrogates such as RPM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗