Search NASA⌕ Search

SEARCH · Search NASA

Results for “Markov process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗

MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.

60 APPLIED LIFE SCIENCES↗

SU-F-R-44: Modeling Lung SBRT Tumor Response Using Bayesian Network Averaging

Purpose: The prediction of tumor control after a patient receives lung SBRT (stereotactic body radiation therapy) has proven to be challenging, due to the complex interactions between an individual’s biology and dose-volume metrics. Many of these variables have predictive power when combined, a feature that we exploit using a graph modeling approach based on Bayesian networks. This provides a probabilistic framework that allows for accurate and visually intuitive predictive modeling. The aim of this study is to uncover possible interactions between an individual patient’s characteristics and generate a robust model capable of predicting said patient’s treatment outcome. Methods: We investigated a cohort of 32 prospective patients from multiple institutions whom had received curative SBRT to the lung. The number of patients exhibiting tumor failure was observed to be 7 (event rate of 22%). The serum concentration of 5 biomarkers previously associated with NSCLC (non-small cell lung cancer) was measured pre-treatment. A total of 21 variables were analyzed including: dose-volume metrics with BED (biologically effective dose) correction and clinical variables. A Markov Chain Monte Carlo technique estimated the posterior probability distribution of the potential graphical structures. The probability of tumor failure was then estimated by averaging the top 100 graphs and applying Baye’s rule. Results: The optimal Bayesian model generated throughout this study incorporated the PTV volume, the serum concentration of the biomarker EGFR (epidermal growth factor receptor) and prescription BED. This predictive model recorded an area under the receiver operating characteristic curve of 0.94(1), providing better performance compared to competing methods in other literature. Conclusion: The use of biomarkers in conjunction with dose-volume metrics allows for the generation of a robust predictive model. The preliminary results of this report demonstrate that it is possible to accurately model the prognosis of an individual lung SBRT patient’s treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-116: Predicting IQ and the Risk of Hearing Loss Following Proton Versus Photon Radiotherapy for Pediatric Brain Tumor Patients

Purpose: The increased sparing of normal tissues in intensity modulated proton therapy (IMPT) compared to photon intensity modulated radiotherapy (IMRT) in brain tumor treatments should translate into improved neurocognitive outcomes. Models were used to estimate the intelligence quotient (IQ) and the risk of hearing loss 5 years post radiotherapy and to compare outcomes of proton against photon in pediatric brain tumors. Methods: Patients who had received radical IMRT were randomly selected from our retrospective database: 10 cases each of craniopharyngioma, ependymoma and medulloblastoma, and 20 cases of glioma. The existing planning CT and contours were used to generate IMPT plans. The RBE-corrected dose to brain structures and cochleas were calculated for both IMPT and IMRT. A model was applied to estimate IQ using a Markov chain Monte Carlo technique. The reported incidence of hearing loss as a function of cochlear dose was used to estimate the rate of occurrence. Results: The average brain dose was less in all IMPT plans compared to IMRT: ranging from a 6.7% reduction (P=0.003) in the case of medulloblastoma to 38% (P=0.007) for craniopharyngioma. This dose reduction translated into a gain in IQ of 1.9 points on average for protons vs photons for the whole cohort at 5 years post-treatment (P=0.011). In terms of specific diseases, the gains in IQ ranged from 0.8 points for medulloblastoma, to 2.7 points for craniopharyngioma. Hearing loss probability was evaluated on a per-ear-basis and was found to be systematically less for proton versus photon: overall 2.9% versus 7.2% (P < 0.001). Conclusion: A novel method was developed to predict neurocognitive outcomes in pediatric brain tumor patients on a case-by-case basis. A modest gain in IQ was systematically observed for proton in all patients. Given the uncertainties within the model used and our reinterpretation, these gains may be underestimated.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-03: Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field

Purpose: Cone beam X-ray luminescence computed tomography (CB-XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. However, the inverse problem of CB-XLCT is seriously ill-conditioned, hindering us to achieve good image quality. In this work, a novel reconstruction method based on Bayesian theory is proposed to tackle this problem Methods: Bayesian theory provides a natural framework for utilizing various kinds of available prior information to improve the reconstruction image quality. A generalized Gaussian Markov random field (GGMRF) model is proposed here to construct the prior model of the Bayesian theory. The most important feature of GGMRF model is the adjustable shape parameter p, which can be continuously adjusted from 1 to 2. The reconstruction image tends to have more edge-preserving property when p is slide to 1, while having more noise tolerance property when p is slide to 2, just like the behavior of L1 and L2 regularization methods, respectively. The proposed method provides a flexible regularization framework to adapt to a wide range of applications. Results: Numerical simulations were implemented to test the performance of the proposed method. The Digimouse atlas were employed to construct a three-dimensional mouse model, and two small cylinders were placed inside to serve as the targets. Reconstruction results show that the proposed method tends to obtain better spatial resolution with a smaller shape parameter, while better signal-to-noise image with a larger shape parameter. Quantitative indexes, contrast-to-noise ratio (CNR) and full-width at half-maximum (FWHM), were used to assess the performance of the proposed method, and confirmed its effectiveness in CB-XLCT reconstruction. Conclusion: A novel reconstruction method for CB-XLCT is proposed based on GGMRF model, which enables an adjustable performance tradeoff between L1 and L2 regularization methods. Numerical simulations were conducted to demonstrate its performance.

60 APPLIED LIFE SCIENCES↗

TU-AB-202-11: Tumor Segmentation by Fusion of Multi-Tracer PET Images Using Copula Based Statistical Methods

Purpose: Multi-tracer PET imaging is getting more attention in radiotherapy by providing additional tumor volume information such as glucose and oxygenation. However, automatic PET-based tumor segmentation is still a very challenging problem. We propose a statistical fusion approach to joint segment the sub-area of tumors from the two tracers FDG and FMISO PET images. Methods: Non-standardized Gamma distributions are convenient to model intensity distributions in PET. As a serious correlation exists in multi-tracer PET images, we proposed a new fusion method based on copula which is capable to represent dependency between different tracers. The Hidden Markov Field (HMF) model is used to represent spatial relationship between PET image voxels and statistical dynamics of intensities for each modality. Real PET images of five patients with FDG and FMISO are used to evaluate quantitatively and qualitatively our method. A comparison between individual and multi-tracer segmentations was conducted to show advantages of the proposed fusion method. Results: The segmentation results show that fusion with Gaussian copula can receive high Dice coefficient of 0.84 compared to that of 0.54 and 0.3 of monomodal segmentation results based on individual segmentation of FDG and FMISO PET images. In addition, high correlation coefficients (0.75 to 0.91) for the Gaussian copula for all five testing patients indicates the dependency between tumor regions in the multi-tracer PET images. Conclusion: This study shows that using multi-tracer PET imaging can efficiently improve the segmentation of tumor region where hypoxia and glucidic consumption are present at the same time. Introduction of copulas for modeling the dependency between two tracers can simultaneously take into account information from both tracers and deal with two pathological phenomena. Future work will be to consider other families of copula such as spherical and archimedian copulas, and to eliminate partial volume effect by considering dependency between neighboring voxels.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-02: A Bayesian Network Approach for Joint Prediction of Tumor Control and Radiation Pneumonitis (RP) in Non-Small-Cell Lung Cancer (NSCLC)

Purpose: NSCLC radiotherapy treatment is a trade-off between controlling the tumor while limiting radiation-induced toxicities. Here we identify hierarchical biophysical relationships that could simultaneously influence both local control (LC) and RP by using an integrated Bayesian Networks (BN) approach. Methods: We studied 79 NSCLC patients treated on prospective protocol with 56 cases of LC and 21 events of RP. Beyond dosimetric information, each patient had 193 features including 12 clinical factors, 60 circulating blood cytokines before and during radiotherapy, 62 microRNAs, and 59 single-nucleotide polymorphisms (SNPs). The most relevant biophysical predictors for both LC and RP were identified using a Markov blanket local discovery algorithm and the corresponding BN was constructed using a score-learning algorithm. The area under the free-response receiver operating characteristics (AU-FROC) was used for performance evaluation. Cross-validation was employed to guard against overfitting pitfalls. Results: A BN revealing the biophysical interrelationships jointly in terms of LC and RP was developed and evaluated. The integrated BN included two SNPs, one microRNA, one clinical factor, three pre-treatment cytokines, relative changes of two cytokines between pre and during-treatment, and gEUDs of the GTV (a=-20) and lung (a=1). On cross-validation, the AUC prediction of independent LC was 0.85 (95% CI: 0.75–0.95) and RP was 0.83 (0.73–0.92). The AU-FROC of the integrated BN to predict both LC/RP was 0.81 (0.71–0.90) based on 2000 stratified bootstrap, indicating minimal loss in joint prediction power. Conclusions: We developed a new approach for multiple outcome utility application in radiotherapy based on integrated BN techniques. The BN developed from large-scale retrospective data is able to simultaneously predict LC and RP in NSCLC treatments based on individual patient characteristics. The joint prediction is only slightly compromised compared to independent predictions. Our approach shows promise for use in clinical decision support system for personalized radiotherapy subject to multiple endpoints. These studies were supported by a grant from the NCI/NIH P01-CA59827.

60 APPLIED LIFE SCIENCES↗

Electron diffraction study of the structural features of kaolinites

The structural variations of kaolinites have been investigated based on oblique-texture electron diffraction patterns. The features of manifestation of the 2D lattice of kaolinite layers in the geometry of the 20l and 13l reflections have been revealed. The manifestation of violations in the regular alternation of layers in kaolinites in the diffraction patterns has been analyzed using a numerical simulation of the diffraction profiles along the first (02l, 11l) and second (20l, 13l) ellipses of oblique-texture electron diffraction patterns. The simulation was performed for finite sequences of ten layers using the statistical Markov model in the quasihomogeneous approximation. It is shown that oblique-texture electron diffraction patterns can be used to reveal the coexistence of two phases with different structural perfections and particle morphologies in kaolinite samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stacking faults in lizardites 1T from electron diffraction data and modeling of diffraction effects

Stacking faults in lizardites 1T (polytype group A) have been studied by analyzing the oblique-texture electron diffraction patterns in combination with a numerical simulation of diffraction patterns. The simulation of diffraction profiles was performed for finite (10-layer) sequences using the statistical Markov model in the quasi-homogeneous approximation. Diffraction criteria are revealed, which indicate the presence of defects in lizardite 1T; these defects are related to the change in the layer orientation by 180 Degree-Sign and displacements of adjacent layers by a/3. It is shown that in the case of the statistical distribution of defects, along with pairs of adjacent layers with layer packing features typical of polytype groups D and B, there are also sequences of layers 1T(A), correspondingly rotated by 180 Degree-Sign or displaced by a/3 and 2a/3 with respect to the layers in the 1T matrix. The data obtained give deeper insight into the variations in layer packing in lizardites 1T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of non-Markovian effects on the fission rate and time

The impact of non-Markovian effects on the fission rate and time is studied on the basis of a generalized one-dimensional Langevin equation. Relevant calculations were performed under the assumption of an exponentially correlated random force appearing in Langevin equations and a constant correlation time. An increase in the fission rate and a decrease in the mean fission time with increasing random-force correlation time were revealed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The alpha and omega of the scientific work of Academician Moisei Aleksandrovich Markov

A brief survey of the scientific, scientific-administrative, and public activity of M. A. Markov is given in regard with his centenary (May 13, 1908–October 1, 1994). The outstanding contribution of Moisei Aleksandrovich to the theory of elementary particle physics, gravitation, and cosmology is pointed out.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Supersymmetry in superspace: 35 years of the research activity in LTP

This is an overview of the all-years research activity in supersymmetry in the Markov-Ogievetsky group at the Bogoliubov Laboratory of Theoretical Physics. It started shortly after the discovery of supersymmetry and is lasting for more than 30 years. In this survey the main emphasis is made on the superspace geometric approaches and unconstrained superfield formulations. Alongside such milestones as the geometric formulation of supergravity and the harmonic superspace approach to extended supersymmetry, some other developments largely contributed by the Dubna theorists are briefly accounted for.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-consistent description of e{sup −} e{sup +}γ{sup −} plasma created from the vacuum in a strong electric laser field

In the present work a closed system of kinetic equations is obtained for the description of the vacuum creation of an electron-positron plasma and secondary photons due to a strong laser field. An estimate for the photon energy distribution is obtained. In the Markovian approximation the photon distribution has a 1/ k spectrum (flicker noise).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gauge fields, nonlinear realizations, supersymmetry

This is a brief survey of the all-years research activity in the Sector “Supersymmetry” (the former Markov Group) at the Bogoliubov Laboratory of Theoretical Physics. The focus is on the issues related to gauge fields, spontaneously broken symmetries in the nonlinear realizations approach, and diverse aspects of supersymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cyclotomic Shuffles

Analogues of 1-shuffle elements for complex reflection groups of type G(m,1,n) are introduced. A geometric interpretation for G(m,1,n) in terms of rotational permutations of polygonal cards is given. We compute the eigenvalues, and their multiplicities, of the 1-shuffle element in the algebra of the group G(m,1,n). Considering shuffling as a random walk on the group G(m,1,n), we estimate the rate of convergence to randomness of the corresponding Markov chain. We report on the spectrum of the 1-shuffle analogue in the cyclotomic Hecke algebra H(m,1,n) for m=2 and small n.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of mixing length estimates and effects of toroidicity in a fluid model for turbulent transport in tokamaks

Basic aspects of turbulent transport in toroidal magnetized plasmas are discussed. In particular the fluid closure has strong effects on zonal flows which are needed to create an absorbing boundary for long wave lengths and also to obtain the Dimits nonlinear upshift. The fluid resonance in the energy equation is found to be instrumental for generating the L–H transition, the spin-up of poloidal rotation in internal transport barriers, as well as the nonlinear Dimits upshift. The difference between the linearly fastest growing mode number and the corresponding longer nonlinear correlation length is also addressed. It is found that the Kadomtsev mixing length result is consistent with the non-Markovian diagonal limit of the transport at the nonlinearly obtained correlation length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetotransport in a 2D system with strong scatterers: Renormalization of Hall coefficient caused by non-Markovian effects

We show that a sharp dependence of the Hall coefficient R on the magnetic field B arises in two-dimensional electron systems with strong scatterers. The phenomenon is due to classical memory effects. We calculate analytically the dependence of R on B for the case of scattering by antidots (modeled by hard disks of radius a), randomly distributed with concentration n{sub 0} << 1/a{sup 2}. We demonstrate that in very weak magnetic fields ({omega}{sub c}{tau}{sub tr} {<=} n{sub 0}a{sup 2}), memory effects lead to a considerable renormalization of the Boltzmann value of the Hall coefficient: {delta}R/R {approx} 1. With increasing magnetic field, the relative correction to R decreases, then changes sign, and saturates at the value {delta}R/R {approx} -n{sub 0}a{sup 2}. We also discuss the effect of the smooth disorder on the dependence of R on B.

36 MATERIALS SCIENCE↗

Quantum Dynamics of a Domain Wall in the Presence of Dephasing

We compare quantum dynamics in the presence of Markovian dephasing for a particle hopping on a chain and for an Ising domain wall whose motion leaves behind a string of flipped spins. Exact solutions show that on an infinite chain, the transport responses of the models are nearly identical. However, on finitelength chains, the broadening of discrete spectral lines is much more noticeable in the case of a domain wall.

97 MATHEMATICS AND COMPUTING↗