Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

JWST/MIRI Coronagraphic Performances as Measured on-Sky

Context . Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope . MIRI, the mid-IR instrument, has the capability to provide unique spatially resolved photometric data points in a spectral range never before achieved for such objects. Aims . We aim to present the very first on-sky contrast measurements of the MIRI coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four-quadrant phase mask for the very first time in a space telescope. Methods . We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference-subtracted contrasts. Results . The MIRI coronagraphs achieve raw contrasts better than 10 −3 at the smallest angular separations (within 1″) and about 10 −5 farther out (beyond 5 ~ 6″). Subtracting the residual diffracted light left behind the coronagraph has the potential to bring the final contrast down to the background- and detector-limited noise floor at most angular separations (a few times 10 −5 at less than 1″). Conclusions . The MIRI coronagraphs behave as expected from simulations. In particular, the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained by subtracting reference stars also meet expectations and are fully demonstrated for two four-quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation in the phase aberrations at the primary mirror during the observations, and not an issue with the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.

High angular resolution instrumentation↗

Machine-Learning-Based Adaptive Thinning of CrIS Radiances to Improve Global Tropical Cyclone Analysis and Forecasts

This work is focused on optimizing the assimilation of hyperspectral infrared (IR) radiances from the Cross-track Infrared Sounder (CrIS) with the goal of improving the representation of tropical cyclones (TCs) in global analyses and forecasts. Current operational assimilation systems rely on subsampling IR radiances on a regular thinning grid. A new and improved adaptive methodology based on machine learning (ML) recognizes TCs from geostationary satellite imagery and is implemented in the Goddard Earth Observing System (GEOS) model and data assimilation framework. The ML methodology is extensively trained on existing TC data sets and creates for each TC a dynamic mask, based on the evolving shape and life cycle of that specific event. Once a TC mask is created, a switch is then activated in the data assimilation system to alter the thinning, ingesting more CrIS radiances within the moving mask, thus increasing the TC sampling. After the TC dissipates, the assimilation of CrIS radiances reverts to normal data density. Results of TC segmentation provided by a state-of-the-art generative machine learning model known as the Denoising Diffusion Probabilistic Model (DDPM) are compared to the previously used U-Net model. The new approach surpasses the performance of the previously developed one. The methodology is applied to both clear-sky and cloud-cleared radiances. Benefits from the latter methodology, particularly in improving the structure of TCs and the intensity forecasts, are presented.

Oreste Reale↗

Method to fabricate a tilted logpile photonic crystal

A method to fabricate a tilted logpile photonic crystal requires only two lithographic exposures and does not require mask repositioning between exposures. The mask and photoresist-coated substrate are spaced a fixed and constant distance apart using a spacer and the stack is clamped together. The stack is then tilted at a crystallographic symmetry angle (e.g., 45 degrees) relative to the X-ray beam and rotated about the surface normal until the mask is aligned with the X-ray beam. The stack is then rotated in plane by a small stitching angle and exposed to the X-ray beam to pattern the first half of the structure. The stack is then rotated by 180.degree. about the normal and a second exposure patterns the remaining half of the structure. The method can use commercially available DXRL scanner technology and LIGA processes to fabricate large-area, high-quality tilted logpile photonic crystals.

Williams, John D↗

Joint spatio-spectral based edge detection for multispectral infrared imagery.

Image segmentation is one of the most important and difficult tasks in digital image processing. It represents a key stage of automated image analysis and interpretation. Segmentation algorithms for gray-scale images utilize basic properties of intensity values such as discontinuity and similarity. However, it is possible to enhance edge-detection capability by means of using spectral information provided by multispectral (MS) or hyperspectral (HS) imagery. In this paper we consider image segmentation algorithms for multispectral images with particular emphasis on detection of multi-color or multispectral edges. More specifically, we report on an algorithm for joint spatio-spectral (JSS) edge detection. By joint we mean simultaneous utilization of spatial and spectral characteristics of a given MS or HS image. The JSS-based edge-detection approach, termed Spectral Ratio Contrast (SRC) edge-detection algorithm, utilizes the novel concept of matching edge signatures. The edge signature represents a combination of spectral ratios calculated using bands that enhance the spectral contrast between the two materials. In conjunction with a spatial mask, the edge signature give rise to a multispectral operator that can be viewed as a three-dimensional extension of the mask. In the extended mask, the third (spectral) dimension of each hyper-pixel can be chosen independently. The SRC is verified using MS and HS imagery from a quantum-dot in a well infrared (IR) focal plane array, and the Airborne Hyperspectral Imager.

99 GENERAL AND MISCELLANEOUS↗

Effect of Unburned Methyl Esters on the NOx Conversion of Fe-Zeolite SCR Catalyst

Engine and flow reactor experiments were conducted to determine the impact of biodiesel relative to ultra-low-sulfur diesel (ULSD) on inhibition of the selective catalytic reduction (SCR) reaction over an Fe-zeolite catalyst. Fe-zeolite SCR catalysts have the ability to adsorb and store unburned hydrocarbons (HC) at temperatures below 300 C. These stored HCs inhibit or block NO{sub x}-ammonia reaction sites at low temperatures. Although biodiesel is not a hydrocarbon, similar effects are anticipated for unburned biodiesel and its organic combustion products. Flow reactor experiments indicate that in the absence of exposure to HC or B100, NO{sub x} conversion begins at between 100 and 200 C. When exposure to unburned fuel occurs at higher temperatures (250-400 C), the catalyst is able to adsorb a greater mass of biodiesel than of ULSD. Experiments show that when the catalyst is masked with ULSD, NO{sub x} conversion is inhibited until it is heated to 400 C. However, when masked with biodiesel, NO{sub x} conversion is observed to begin at temperatures as low as 200 C. Engine test results also show low-temperature recovery from HC storage. Engine tests indicate that, overall, the SCR system has a faster recovery from HC masking with biodiesel. This is at least partially due to a reduction in exhaust HCs, and thus total HC exposure with biodiesel.

09 BIOMASS FUELS↗

Apparatus and method to achieve high-resolution microscopy with non-diffracting or refracting radiation

An imaging system employing a coded aperture mask having multiple pinholes is provided. The coded aperture mask is placed at a radiation source to pass the radiation through. The radiation impinges on, and passes through an object, which alters the radiation by absorption and/or scattering. Upon passing through the object, the radiation is detected at a detector plane to form an encoded image, which includes information on the absorption and/or scattering caused by the material and structural attributes of the object. The encoded image is decoded to provide a reconstructed image of the object. Because the coded aperture mask includes multiple pinholes, the radiation intensity is greater than a comparable system employing a single pinhole, thereby enabling a higher resolution. Further, the decoding of the encoded image can be performed to generate multiple images of the object at different distances from the detector plane. Methods and programs for operating the imaging system are also disclosed.

47 OTHER INSTRUMENTATION↗

Zone routing in a torus network

A system for routing data in a network comprising a network logic device at a sending node for determining a path between the sending node and a receiving node, wherein the network logic device sets one or more selection bits and one or more hint bits within the data packet, a control register for storing one or more masks, wherein the network logic device uses the one or more selection bits to select a mask from the control register and the network logic device applies the selected mask to the hint bits to restrict routing of the data packet to one or more routing directions for the data packet within the network and selects one of the restricted routing directions from the one or more routing directions and sends the data packet along a link in the selected routing direction toward the receiving node.

97 MATHEMATICS AND COMPUTING↗

Methods of fabrication of graphene nanoribbons

Methods of fabricating graphene nanoribbons include depositing a catalyst layer on a substrate. A masking layer is deposited on the catalyst layer. The masking layer and the catalyst layer are etched to form a structure on the substrate, the structure comprising a portion of the catalyst layer and a portion of the masking layer disposed on the catalyst layer, with sidewalls of the catalyst layer being exposed. A graphene layer is formed on a sidewall of the catalyst layer with a carbon-containing gas.

36 MATERIALS SCIENCE↗

Thermal and Electrical Effects of Partial Shade in Monolithic Thin-Film Photovoltaic Modules: Preprint

Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature and current density compared to masks covering entire cells.

14 SOLAR ENERGY↗

Methods of removing a ceramic coating from a substrate

A method for removing a ceramic coating from a substrate is presented. The method includes contacting the ceramic coating with a composition including a fluoride source and nitric acid. A method of forming a component having a variation in saturation magnetization is presented. The method includes masking selected portions of a surface of a metallic component using a ceramic coating to form a masked metallic component; selectively diffusing nitrogen into the metallic component by exposing the masked metallic component to a nitrogen-rich atmosphere; and removing the ceramic coating from the surface of the metallic component by contacting the ceramic coating with a composition including the fluoride source and nitric acid.

36 MATERIALS SCIENCE↗

Compressive scanning spectroscopy

Mask-modulated spectra are incident to a sensor and are summed during a frame time. After the frame time, a compressed spectrum is read out based on the sum and decompressed to obtain spectra for some or all specimen locations. The mask-modulated spectrum that are summed are associated with different modulations produced by a common mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods of making a component with variable magnetization and related components

A method of forming a component having a variation in saturation magnetization is presented. The method includes selectively diffusing nitrogen into a metallic component of a masked metallic component by exposing the masked metallic component to a nitrogen-rich atmosphere. The masked metallic component includes a patterned oxide layer formed on a surface of the metallic component, and the patterned oxide layer includes an oxide of a metal present in the metallic component. A related component is also presented.

36 MATERIALS SCIENCE↗

System and method for sub micron additive manufacturing

An apparatus is disclosed for performing an additive manufacturing operation to form a structure by processing a photopolymer resist material. The apparatus may incorporate a laser for generating a laser beam, and a tunable mask for receiving the laser beam which has an optically dispersive element. The mask splits the laser beam into a plurality of emergent beams each having a subplurality of beamlets of varying or identical intensity, with each beamlet emerging from a unique subsection of illuminated regions of the mask. A collimator collimates at least one of the emergent beams to form a collimated beam. One or more focusing elements focuses the collimated beam into a focused beam which is projected as a focused image plane on or within the resist material. The focused beam simultaneously illuminates a layer of the resist material to process an entire layer in a parallel fashion.

Saha, Sourabh Kumar↗

GaN vertical-channel junction field-effect transistors with regrown p-GaN by metal organic chemical vapor deposition (MOCVD)

Fabricating a vertical-channel junction field-effect transistor includes forming an unintentionally doped GaN layer on a bulk GaN layer by metalorganic chemical vapor deposition, forming a Cr/SiO 2 hard mask on the unintentionally doped GaN layer, patterning a fin by electron beam lithography, defining the Cr and SiO 2 hard masks by reactive ion etching, improving a regrowth surface with inductively coupled plasma etching, removing hard mask residuals, regrowing a p-GaN layer, selectively etching the p-GaN layer, forming gate electrodes by electron beam evaporation, and forming source and drain electrodes by electron beam evaporation. The resulting vertical-channel junction field-effect transistor includes a doped GaN layer, an unintentionally doped GaN layer on the doped GaN layer, and a p-GaN regrowth layer on the unintentionally doped GaN layer. Portions of the p-GaN regrowth layer are separated by a vertical channel of the unintentionally doped GaN layer.

Zhao, Yuji↗

Using Radiochromic Films to Characterize the Dispersion of ZrO{sub 2} Nano-sized Grain Clusters in Protective Polymer Composites

Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic film commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Improving the performance of the actinic inspection tool with an optimized alignment procedure

Extreme ultraviolet (EUV) microscopy is an important tool for the investigation of the performance of EUV masks, for detecting the presence and the characteristics of defects, and for evaluating the effectiveness of defect repair techniques. Aerial image measurement bypasses the difficulties inherent to photoresist imaging and enables high data collection speed and flexibility. It provides reliable and quick feedback for the development of masks and lithography system modeling methods. We operate the SEMATECH Berkeley Actinic Inspection Tool (AIT), a EUV microscope installed at the Advanced Light Source at Lawrence Berkeley National Laboratory. The AIT is equipped with several high-magnification Fresnel zoneplate lenses, with various numerical aperture values, that enable it image the reflective mask surface with various resolution and magnification settings. Although the AIT has undergone significant recent improvements in terms of imaging resolution and illumination uniformity, there is still room for improvement. In the AIT, an off-axis zoneplate lens collects the light coming from the sample and an image of the sample is projected onto an EUV-sensitive CCD camera. The simplicity of the optical system is particularly helpful considering that the AIT alignment has to be performed every time that a sample or a zoneplate is replaced. The alignment is sensitive to several parameters such as the lens position and orientation, the illumination direction and the sample characteristics. Since the AIT works in high vacuum, there is no direct access to the optics or to the sample during the alignment and the measurements. For all these reasons the alignment procedures and feedback can be complex, and in some cases can reduce the overall data throughput of the system. In this paper we review the main strategies and procedures that have been developed for quick and reliable alignments, and we describe the performance improvements we have achieved, in terms of aberration magnitude reduction.

36 MATERIALS SCIENCE↗

Pushing EUV lithography development beyond 22-nm half pitch

Microfield exposure tools (METs) have and continue to play a dominant role in the development of extreme ultraviolet (EUV) resists and masks. One of these tools is the SEMATECH Berkeley 0.3 numerical aperture (NA) MET. Here we investigate the possibilities and limitations of using the 0.3-NA MET for sub-22-nm half-pitch development. We consider mask resolution limitations and present a method unique to the centrally obscured MET allowing these mask limitations to be overcome. We also explore projection optics resolution limits and describe various illumination schemes allowing resolution enhancement. At 0.3-NA, the 0.5 k1 factor resolution limit is 22.5 nm meaning that conventional illumination is of limited utility for sub-22-nm development. In general resolution enhancing illumination encompasses increased coherence. We study the effect of this increased coherence on line-edge roughness, which along with resolution is another crucial factor in sub-22-nm resist development.

36 MATERIALS SCIENCE↗