At least 901 records · Page 50

The Role of Platelet Factor 4 in Radiation-Induced Thrombocytopenia

Purpose: Factors affecting the severity of radiation-induced thrombocytopenia (RIT) are not well described. We address whether platelet factor 4 (PF4; a negative paracrine for megakaryopoiesis) affects platelet recovery postradiation. Methods and Materials: Using conditioned media from irradiated bone marrow (BM) cells from transgenic mice overexpressing human (h) PF4 (hPF4+), megakaryocyte colony formation was assessed in the presence of this conditioned media and PF4 blocking agents. In a model of radiation-induced thrombocytopenia, irradiated mice with varying PF4 expression levels were treated with anti-hPF4 and/or thrombopoietin (TPO), and platelet count recovery and survival were examined. Results: Conditioned media from irradiated BM from hPF4+ mice inhibited megakaryocyte colony formation, suggesting that PF4 is a negative paracrine released in RIT. Blocking with an anti-hPF4 antibody restored colony formation of BM grown in the presence of hPF4+ irradiated media, as did antibodies that block the megakaryocyte receptor for PF4, low-density lipoprotein receptor-related protein 1 (LRP1). Irradiated PF4 knockout mice had higher nadir platelet counts than irradiated hPF4+/knockout litter mates (651 vs. 328 x 106/mcL, p = 0.02) and recovered earlier (15 days vs. 22 days, respectively, p <0.02). When irradiated hPF4+ mice were treated with anti-hPF4 antibody and/or TPO, they showed less severe thrombocytopenia than untreated mice, with improved survival and time to platelet recovery, but no additive effect was seen. Conclusions: Our studies show that in RIT, damaged megakaryocytes release PF4 locally, inhibiting platelet recovery. Blocking PF4 enhances recovery while released PF4 from megakaryocytes limits TPO efficacy, potentially because of increased release of PF4 stimulated by TPO. The clinical value of blocking this negative paracrine pathway post-RIT remains to be determined.

60 APPLIED LIFE SCIENCES↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The influence of environmental microseismicity on detection and interpretation of small-magnitude events in a polar glacier setting

Glacial environments exhibit temporally variable microseismicity. To investigate how microseismicity influences event detection, we implement two noise-adaptive digital power detectors to process seismic data from Taylor Glacier, Antarctica. We add scaled icequake waveforms to the original data stream, run detectors on the hybrid data stream to estimate reliable detection magnitudes and compare analytical magnitudes predicted from an ice crack source model. We find that detection capability is influenced by environmental microseismicity for seismic events with source size comparable to thermal penetration depths. When event counts and minimum detectable event sizes change in the same direction (i.e. increase in event counts and minimum detectable event size), we interpret measured seismicity changes as ‘true’ seismicity changes rather than as changes in detection. Generally, one detector (two degree of freedom (2dof)) outperforms the other: it identifies more events, a more prominent summertime diurnal signal and maintains a higher detection capability. We conclude that real physical processes are responsible for the summertime diurnal inter-detector difference. One detector (3dof) identifies this process as environmental microseismicity; the other detector (2dof) identifies it as elevated waveform activity. Our analysis provides an example for minimizing detection biases and estimating source sizes when interpreting temporal seismicity patterns to better infer glacial seismogenic processes.

54 ENVIRONMENTAL SCIENCES↗

X-RAY OBSERVATIONS OF RADIO TRANSIENTS WITHOUT OPTICAL HOSTS

We present a 50 ks Chandra/ACIS-I X-ray observation of the Bower et al. Very Large Array archival field. The observations reach a limiting sensitivity of {approx}10{sup -4} counts s{sup -1}, corresponding to a flux of a few times 10{sup -15} erg s{sup -1} cm{sup -2} for the models we explore. The Chandra observations were undertaken to search for X-ray counterparts to the eight transient sources without optical counterparts, and the two transient sources with optical counterparts seen by Bower et al. Neither of the sources with optical counterparts was detected in X-rays. One of the eight optical non-detections is associated with a marginal (2.4{sigma}) X-ray detection in our Chandra image. A second optically undetected Bower et al. transient may be associated with a z = 1.29 X-ray-detected quasar or its host galaxy, or alternatively is undetected in X-rays and is a chance association with the nearby X-ray source. The X-ray flux upper limits, and the one marginal detection, are consistent with the interpretation of Ofek et al. that the optically undetected radio transients are flares from isolated old Galactic neutron stars. The marginal X-ray detection has a hardness ratio that implies a temperature too high for a simple one-temperature neutron star model, but plausible multi-component fits are not excluded, and in any case the marginal X-ray detection may be due to cosmic rays or particle background. The X-ray flux upper limits are also consistent with flare star progenitors at {approx}> 1 kpc (which would require the radio luminosity of the transient to be unusually high for such an object) or less extreme flares from brown dwarfs at distances of around 100 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

eDNAjoint: An R package for interpreting paired or semi‐paired environmental DNA and traditional survey data in a Bayesian framework

Abstract Environmental DNA (eDNA) sampling is increasingly used in surveys of species distribution as a potentially sensitive and efficient monitoring method. Yet access to modelling tools designed specifically for interpreting this new data type lags behind its ubiquity. While occupancy modelling software has dominated the analytical landscape for eDNA data analysis of single species, this type of model may not always be the most appropriate. The rate of eDNA detection often corresponds to species density, rather than just occupancy, and researchers often have access to observations from non‐genetic sampling methods at the same sites. To provide users access to a modelling framework designed to maximize the use of all available data, we developed an R package, eDNAjoint . The package provides an easy‐to‐use interface for fitting a ‘joint’ model that integrates data from paired or semi‐paired eDNA and traditional surveys in a Bayesian framework. The model can be used to estimate parameters like the probability of a false positive eDNA detection and mean catch rate at a site, and the package allows access to multiple model variations and Bayesian prior customization. Additional functionality can be used for model selection, summarising posteriors and comparing the relative sensitivities of the two survey methods. We demonstrate the use of eDNAjoint by fitting a variation of the model with site‐level covariates that scale the sensitivity of eDNA sampling relative to traditional sampling. The example workflow uses binary eDNA and seine count data for the endangered tidewater goby ( Eucyclogobius newberryi ) from a study by Schmelzle and Kinziger (2016). This use case includes a prior sensitivity analysis and an evaluation of the relationship between detection rates and environmental variables. eDNAjoint has the potential to greatly increase the range of users who will be able to rigorously analyse eDNA and traditional survey data in a Bayesian framework, understand if and how eDNA can improve monitoring practices, and gain confidence in the interpretability of eDNA data.

Keller, Abigail G. [Department of Environment Scie↗

Space-Time Block Preconditioning for Incompressible Flow

Parallel-in-time methods have become increasingly popular in the simulation of time-dependent numerical PDEs, allowing for the efficient use of additional message passing interface processes when spatial parallelism saturates. Most methods treat the solution and parallelism in space and time separately. In contrast, all-at-once methods solve the full space-time system directly, largely treating time as simply another spatial dimension. All-at-once methods offer a number of benefits over separate treatment of space and time, most notably significantly increased parallelism and faster time to solution (when applicable). However, the development of fast, scalable all-at-once methods has largely been limited to time-dependent (advection-)diffusion problems. This paper introduces the concept of space-time block preconditioning for the all-at-once solution of incompressible flow. By extending well-known concepts of spatial block preconditioning to the space-time setting, we develop a block preconditioner whose application requires the solution of a space-time (advection-)diffusion equation in the velocity block, coupled with a pressure Schur complement approximation consisting of independent spatial solves at each time-step, and a space-time matrix-vector multiplication. The new method is tested on four classical models in incompressible flow. Finally, the results indicate perfect scalability in refinement of spatial and temporal mesh spacing, perfect scalability in nonlinear Picard iteration count when applied to a nonlinear Navier--Stokes problem, and minimal overhead in terms of number of preconditioner applications compared with sequential time-stepping.

97 MATHEMATICS AND COMPUTING↗

Compact Cloud Condensation Nucleus Counter for Unmanned Aerial Systems (UAS) and Long-Term Monitoring Applications (Final Report)

Brechtel Manufacturing Incorporated (BMI) is developing a compact, modular suite of new aerosol measurement technologies optimized for use on Unmanned Aerial Vehicles (UAVs) and other applications where space, weight, power and cost are significant barriers to deployment. The project is focused on a cloud condensation nucleus counter that exposes sampled particles to a simulated cloud environment and counts how many of the particles grow to micron-sized droplets. The new development helps address the need for reduced uncertainties in climate model sensitivities to ambient aerosol properties by promoting the capability to perform aerosol measurements more often, in more locations, and at reduced cost. Applications of the new technology include long-term measurements of the aerosol effects on cloud radiation, microphysical and precipitation processes, weather prediction and modelling studies, and weather modification studies.

47 OTHER INSTRUMENTATION↗

Galaxy Evolution in the Radio Band: The Role of Star-forming Galaxies and Active Galactic Nuclei

We investigate the astrophysics of radio-emitting star-forming galaxies and active galactic nuclei (AGNs) and elucidate their statistical properties in the radio band, including luminosity functions, redshift distributions, and number counts at sub-mJy flux levels, which will be crucially probed by next-generation radio continuum surveys. Specifically, we exploit the model-independent approach by Mancuso et al. to compute the star formation rate functions, the AGN duty cycles, and the conditional probability of a star-forming galaxy to host an AGN with given bolometric luminosity. Coupling these ingredients with the radio emission properties associated with star formation and nuclear activity, we compute relevant statistics at different radio frequencies and disentangle the relative contribution of star-forming galaxies and AGNs in different radio luminosity, radio flux, and redshift ranges. Finally, we highlight that radio-emitting star-forming galaxies and AGNs are expected to host supermassive black holes accreting with different Eddington ratio distributions and to occupy different loci in the galaxy main-sequence diagrams. These specific predictions are consistent with current data sets but need to be tested with larger statistics via future radio data with multiband coverage on wide areas, as will become routinely achievable with the advent of the Square Kilometre Array and its precursors.

79 ASTRONOMY AND ASTROPHYSICS↗

rain (a1)

A rain gauge (RAIN) gathers and measures the amount of liquid precipitation over a set period of time. ARM uses many types of rain gauges at its climate research facilities. The tipping bucket rain gauge consists of a funnel that collects and directs precipitation into a seesaw container that tips after a pre-set amount of liquid enters. When the seesaw tips, it sends an electrical signal that is counted by a recording device. The weighing precipitation gauge consists of a storage container, which is weighted to record the mass of precipitation. Some models measure the mass of precipitation using a pen on a rotating drum or by using a vibrating wire attached to a data logger. The advantage of this type of rain gauge is that it can measure all forms of precipitation. Disdrometers are used with rain gauges to add details about the precipitation being gathered. They are capable of measuring the velocity and size distribution of precipitation, measurements important for studying the evolution of water droplets.

54 ENVIRONMENTAL SCIENCES↗

rain (b1)

A rain gauge (RAIN) gathers and measures the amount of liquid precipitation over a set period of time. ARM uses many types of rain gauges at its climate research facilities. The tipping bucket rain gauge consists of a funnel that collects and directs precipitation into a seesaw container that tips after a pre-set amount of liquid enters. When the seesaw tips, it sends an electrical signal that is counted by a recording device. The weighing precipitation gauge consists of a storage container, which is weighted to record the mass of precipitation. Some models measure the mass of precipitation using a pen on a rotating drum or by using a vibrating wire attached to a data logger. The advantage of this type of rain gauge is that it can measure all forms of precipitation. Disdrometers are used with rain gauges to add details about the precipitation being gathered. They are capable of measuring the velocity and size distribution of precipitation, measurements important for studying the evolution of water droplets.

54 ENVIRONMENTAL SCIENCES↗

On Deciding between Conservative and Optimistic Approaches on Massively Parallel Platforms

Over 5000 publications on parallel discrete event simulation (PDES) have appeared in the literature to date. Nevertheless, few articles have focused on empirical studies of PDES performance on large supercomputer-based systems. This gap is bridged here, by undertaking a parameterized performance study on thousands of processor cores of a Blue Gene supercomputing system. In contrast to theoretical insights from analytical studies, our study is based on actual implementation in software, incurring the actual messaging and computational overheads for both conservative and optimistic synchronization approaches of PDES. Complex and counter-intuitive effects are uncovered and analyzed, with different event timestamp distributions and available levels of concurrency in the synthetic benchmark models. The results are intended to provide guidance to the PDES community in terms of how the synchronization protocols behave at high processor core counts using a state-of-the-art supercomputing systems.

97 MATHEMATICS AND COMPUTING↗

Passive Neutron Non-Destructive Assay for Remediation of Radiological Waste at Hanford Burial Grounds- 13189

The Hanford burial grounds contains a broad spectrum of low activity radioactive wastes, transuranic (TRU) wastes, and hazardous wastes including fission products, byproduct material (thorium and uranium), plutonium and laboratory chemicals. A passive neutron non-destructive assay technique has been developed for characterization of shielded concreted drums exhumed from the burial grounds. This method facilitates the separation of low activity radiological waste containers from TRU waste containers exhumed from the burial grounds. Two identical total neutron counting systems have been deployed, each consisting of He-3 detectors surrounded by a polyethylene moderator. The counts are processed through a statistical filter that removes outliers in order to suppress cosmic spallation events and electronic noise. Upon completion of processing, a 'GO / NO GO' signal is provided to the operator based on a threshold level equivalent to 0.5 grams of weapons grade plutonium in the container being evaluated. This approach allows instantaneous decisions to be made on how to proceed with the waste. The counting systems have been set up using initial on-site measurements (neutron emitting standards loaded into surrogate waste containers) combined with Monte Carlo modeling techniques. The benefit of this approach is to allow the systems to extend their measurement ranges, in terms of applicable matrix types and container sizes, with minimal interruption to the operations at the burial grounds. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical error bars and RSD for neutron multiplicity counting

This article derives the standard deviation of the moments of neutron multiplicity distributions for both random and (shift register) triggered counting gates by propagating the multinomial distribution of errors in the counting distribution. Exact and approximate analytical formulas for the singles, doubles, and triples error bars are given along with the corresponding RSD (relative standard deviation). These analytical formulas provide a simple way to analyze and predict error bars without needing empirical data or simulations. The comparison of these analytical error bars to actual measurement errors can reveal systematic errors that are not being accounted for in the modeling of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVOLUTION OF X-RAY SPECTRA AND LIGHT CURVES OF V1494 AQUILAE

We present six Chandra X-ray spectra and light curves obtained for the nova V1494 Aql (1999 No. 2) in outburst. The first three observations were taken with the Advanced CCD Imaging Spectrometer (ACIS-I) on days 134, 187, and 248 after outburst. The count rates were 1.00, 0.69, and 0.53 counts s{sup -1}, respectively. We found no significant periodicity in the ACIS light curves. The X-ray spectra show continuum emission and lines originating from N and O. We found acceptable spectral fits using isothermal APEC models with significantly increased elemental abundances of O and N for all observations. On day 248 after outburst a bright soft component appeared in addition to the fading emission lines. The Chandra observations on days 300, 304, and 727 were carried out with the High Resolution Camera/Low Energy Transmission Grating Spectrometer (LETGS). The spectra consist of continuum emission plus strong emission lines of O and N, implying a high abundance of these elements. On day 300, a flare occurred and periodic oscillations were detected in the light curves taken on days 300 and 304. This flare must have originated deep in the outflowing material since it was variable on short timescales. The spectra extracted immediately before and after the flare are remarkably similar, implying that the flare was an extremely isolated event. Our attempts to fit blackbody, cloudy, or APEC models to the LETGS spectra failed, owing to the difficulty in disentangling continuum and emission-line components. The spectrum extracted during the flare shows a significant increase in the strengths of many of the lines and the appearance of several previously undetected lines. In addition, some of the lines seen before and after the flare are not present during the flare. On day 727 only the count rate from the zeroth order could be derived, and the source was too faint for the extraction of a light curve or spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

Zero-truncated Poisson regression for sparse multiway count data corrupted by false zeros

Abstract We propose a novel statistical inference methodology for multiway count data that is corrupted by false zeros that are indistinguishable from true zero counts. Our approach consists of zero-truncating the Poisson distribution to neglect all zero values. This simple truncated approach dispenses with the need to distinguish between true and false zero counts and reduces the amount of data to be processed. Inference is accomplished via tensor completion that imposes low-rank tensor structure on the Poisson parameter space. Our main result shows that an $N$-way rank-$R$ parametric tensor $\boldsymbol{\mathscr{M}}\in (0,\infty )^{I\times \cdots \times I}$ generating Poisson observations can be accurately estimated by zero-truncated Poisson regression from approximately $IR^2\log _2^2(I)$ non-zero counts under the nonnegative canonical polyadic decomposition. Our result also quantifies the error made by zero-truncating the Poisson distribution when the parameter is uniformly bounded from below. Therefore, under a low-rank multiparameter model, we propose an implementable approach guaranteed to achieve accurate regression in under-determined scenarios with substantial corruption by false zeros. Several numerical experiments are presented to explore the theoretical results.

97 MATHEMATICS AND COMPUTING↗

Neutron Coincidence Counting Studies

The efficiency comparison for measured and simulated responses of a 10 B-lined proportional counter and a 3 He proportional counter in a close, symmetrical geometry are presented. The measurement geometry was modeled in MCNPX to validate the methods used for simulating the response of both the 3 He and 10 B-lined tubes. The MCNPX models agree within 1% with the 3 He tube measurements and within 3% for the 10 B-lined tubes when a 0.75-µm boron-metal lining is used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗