Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Process for rapid detection of fratricidal defects on optics using Linescan Phase Differential Imaging

Phase-defects on optics used in high-power lasers can cause light intensification leading to laser-induced damage of downstream optics. We introduce Linescan Phase Differential Imaging (LPDI), a large-area dark-field imaging technique able to identify phase-defects in the bulk or surface of large-aperture optics with a 67 second scan-time. Potential phase-defects in the LPDI images are indentified by an image analysis code and measured with a Phase Shifting Diffraction Interferometer (PSDI). The PSDI data is used to calculate the defects potential for downstream damage using an empirical laser-damage model that incorporates a laser propagation code. A ray tracing model of LPDI was developed to enhance our understanding of its phase-defect detection mechanism and reveal limitations.

42 ENGINEERING↗

Single-shot optical recorder with sub-picosecond resolution and scalable record length on a semiconductor wafer

In this study, we demonstrate a novel, single-shot recording technology for transient optical signals. A resolution of 0.4 ps over a record length of 54 ps was demonstrated. Here, a pump pulse crossing through a signal samples a diagonal “slice” of space–time, enabling a camera to record spatially the time content of the signal. Unlike related X (2) -based cross-correlation techniques, here the signal is sampled through optically pumped carriers that modify the refractive index of a silicon wafer. Surrounding the wafer with birefringent retarders enables two time-staggered, orthogonally polarized signal copies to probe the wafer. Recombining the copies at a final crossed polarizer destructively interferes with them, except during the brief stagger window, where a differential phase shift is incurred. This enables the integrating response of the rapidly excited but persistent carriers to be optically differentiated. Lastly, this sampling mechanism has several advantages that enable scaling to long record lengths, including making use of large, inexpensive semiconductor wafers, eliminating the need for phase matching, broad insensitivity to the spectral and angular properties of the pump, and overall hardware simplicity.

42 ENGINEERING↗

Evidence for dispersing 1D Majorana channels in an iron-based superconductor

The possible realization of Majorana fermions as quasiparticle excitations in condensed-matter physics has created much excitement. Most studies have focused on Majorana bound states; however, propagating Majorana states with linear dispersion have also been predicted. Here, we report scanning tunneling spectroscopic measurements of crystalline domain walls (DWs) in FeSe 0.45 Te 0.55 . We located DWs across which the lattice structure shifts by half a unit cell. These DWs have a finite, flat density of states inside the superconducting gap, which is a hallmark of linearly dispersing modes in one dimension. This signature is absent in DWs in the related superconductor, FeSe, which is not in the topological phase. Our joint data are consistent with the observation of dispersing Majorana states at a π-phase shift DW in a proximitized topological material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase-sensitive two-dimensional neutron shearing interferometer and Hartmann sensor

A neutron imaging system detects both the phase shift and absorption of neutrons passing through an object. The neutron imaging system is based on either of two different neutron wavefront sensor techniques: 2-D shearing interferometry and Hartmann wavefront sensing. Both approaches measure an entire two-dimensional neutron complex field, including its amplitude and phase. Each measures the full-field, two-dimensional phase gradients and, concomitantly, the two-dimensional amplitude mapping, requiring only a single measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable 0–π Josephson junctions containing a ferromagnetic spin valve

Superconductivity and ferromagnetism are antagonistic forms of order, and rarely coexist. Many interesting new phenomena occur, however, in hybrid superconducting/ferromagnetic systems. For example, a Josephson junction containing a ferromagnetic material can exhibit an intrinsic phase shift of π in its ground state for certain thicknesses of the material. Such ‘π-junctions’ were first realized experimentally in 2001, and have been proposed as circuit elements for both high-speed classical superconducting computing and for quantum computing. Here we demonstrate experimentally that the phase state of a Josephson junction containing two ferromagnetic layers can be toggled between 0 and pi by changing the relative orientation of the two magnetizations. These controllable 0–π junctions have immediate applications in cryogenic memory, where they serve as a necessary component to an ultralow power superconducting computer. Such a fully superconducting computer is estimated to be orders of magnitude more energy-efficient than current semiconductor-based supercomputers. Here, phase-controllable junctions also open up new possibilities for superconducting circuit elements such as superconducting ‘programmable logic’, where they could function in superconducting analogues to field-programmable gate arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Biotic and abiotic pathways of phosphorus cycling in minerals and sediments: insights from oxygen isotopes in phosphate

A key question to address in the development of oxygen isotope ratios in phosphate (18Op) as a tracer of biogeochemical cycling of phosphorus in ancient and modern environments is the nature of isotopic signatures associated with uptake and cycling of mineral-bound phosphate by microorganisms. Here we present experimental results aimed at understanding the biotic and abiotic pathway of P cycling during biological uptake of phosphate sorbed to ferrihydrite and the selective uptake of specific sedimentary phosphate phases by Escherichia coli, Vibrio fischeri and Marinobacter aquaeolei. Results indicate that a significant fraction of ferrihydrite-bound phosphate is biologically available. The fraction of phosphate taken up by E. coli attained an equilibrium isotopic composition in a short time (<50 hrs) due to efficient O-isotope exchange between phosphate and water (biotic pathway). The difference in isotopic composition between newly equilibrated aqueous and residual sorbed phosphate promoted the exchange of intact phosphate radicals (abiotic pathway) so that this difference gradually became negligible. In sediment containing different P phases, E. coli and V. fischeri ‘extracted’ loosely sorbed phosphate first while M. aquaeolei preferred iron-oxide bound phosphate. Each bacterium imprinted a biotic isotopic signature on each P phase that it took up and cycled. For example, the 18Op value of the sorbed phosphate phase shifted gradually towards equilibrium isotopic composition and the value of Fe oxide-bound phosphate showed slight changes at first, but when new iron oxides were formed, co-precipitated/occluded phosphate retained 18O values of aqueous phosphate at that time. Concentrations and isotopic compositions of authigenic and detrital phosphates did not change, suggesting that these phosphate phases were not utilized by bacteria. These findings support burgeoning applications of 18Op as a tracer of phosphorus cycling in sediments, soils and aquatic environments and as an indicator of paleo- environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Grating-based x-ray differential phase contrast imaging with twin peaks in phase-stepping curves—phase retrieval and dewrapping

Purpose: X-ray differential phase contrast CT implemented with Talbot interferometry employs phase-stepping to extract information of x-ray attenuation, phase shift, and small-angle scattering. Since inaccuracy may exist in the absorption grating G{sub 2} due to an imperfect fabrication, the effective period of G{sub 2} can be as large as twice the nominal period, leading to a phenomenon of twin peaks that differ remarkably in their heights. In this work, the authors investigate how to retrieve and dewrap the phase signal from the phase-stepping curve (PSC) with the feature of twin peaks for x-ray phase contrast imaging. Methods: Based on the paraxial Fresnel–Kirchhoff theory, the analytical formulae to characterize the phenomenon of twin peaks in the PSC are derived. Then an approach to dewrap the retrieved phase signal by jointly using the phases of the first- and second-order Fourier components is proposed. Through an experimental investigation using a prototype x-ray phase contrast imaging system implemented with Talbot interferometry, the authors evaluate and verify the derived analytic formulae and the proposed approach for phase retrieval and dewrapping. Results: According to theoretical analysis, the twin-peak phenomenon in PSC is a consequence of combined effects, including the inaccuracy in absorption grating G{sub 2}, mismatch between phase grating and x-ray source spectrum, and finite size of x-ray tube’s focal spot. The proposed approach is experimentally evaluated by scanning a phantom consisting of organic materials and a lab mouse. The preliminary data show that compared to scanning G{sub 2} over only one single nominal period and correcting the measured phase signal with an intuitive phase dewrapping method that is being used in the field, stepping G{sub 2} over twice its nominal period and dewrapping the measured phase signal with the proposed approach can significantly improve the quality of x-ray differential phase contrast imaging in both radiograph and CT. Conclusions: Using the phase retrieval and dewrapping methods proposed to deal with the phenomenon of twin peaks in PSCs and phase wrapping, the performance of grating-based x-ray differential phase contrast radiography and CT can be significantly improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergence of higher order rotational symmetry in the hidden order phase of URu 2 Si 2

Electrical resistivity measurements were performed in this paper as functions of temperature, magnetic field, and angle θ between the magnetic field and the c-axis of a URu 2 Si 2 single crystal. The resistivity exhibits a two-fold oscillation as a function of θ at high temperatures, which undergoes a 180°-phase shift (sign change) with decreasing temperature at around 35 K. The hidden order transition is manifested as a minimum in the magnetoresistance and amplitude of the two-fold oscillation. Interestingly, the resistivity also showed four-fold, six-fold, and eight-fold symmetries at the hidden order transition. These higher order symmetries were also detected at low temperatures, which could be a sign of the formation of another pseudogap phase above the superconducting transition, consistent with recent evidence for a pseudogap from point-contact spectroscopy measurements and NMR. Measurements of the magnetisation of single crystalline URu 2 Si 2 with the magnetic field applied parallel and perpendicular to the crystallographic c-axis revealed regions with linear temperature dependencies between the hidden order transition temperature and about 25 K. Finally, this T-linear behaviour of the magnetisation may be associated with the formation of a precursor phase or ‘pseudogap’ in the density of states in the vicinity of 30–35 K.

36 MATERIALS SCIENCE↗

Interference in nonlinear Compton scattering using a Schrödinger-equation approach

The interference between Compton scattering and nonlinear Compton scattering from a two-color field in the X-ray regime is theoretically examined for bound electrons. Here, the underlying phase shifts are analyzed using a perturbative approach in the incoming classical field. The perturbative approach is bench marked with a non-perturbative approach in the classical field. The interference for different combinations of linear polarization of the two fields is examined when the Compton and the nonlinear Compton scattered waves have the same wave vector and polarization. Only two cases exhibit interference. When there is interference, the calculations reveal an intrinsic phase difference between the Compton scattered wave function and the nonlinear Compton scattered wave function of either 0 or pi depending on the scattering angle.

74 ATOMIC AND MOLECULAR PHYSICS↗

Size dependent lattice pseudosymmetry for frustrated decahedral nanoparticles

Geometric frustration—where geometry prevents simultaneous satisfaction of local interactions—generates pseudosymmetry and emergent behaviors across physical and biological systems. At the nanoscale, pseudosymmetric features in crystalline materials manifest as local strain and distortion, but how they depend on particle size and control structural stability remains unclear. Here, we report the first study of a size-dependent crossover in pseudosymmetry in multi-twinned gold nanoparticles (NPs), combining four-dimensional scanning transmission electron microscopy with nanoscale strain mapping grounded in continuum solid mechanics. Analysis of more than 20 decahedral NPs (20–55 nm) reveals pronounced heterogeneity in multiple modes of in-plane strain and displacement field in small NPs as five tetrahedral grains close the geometric gap, without extended defects. With increasing particle size, strain fields homogenize across grains and local phases shift from predominantly low-symmetry body-centered tetragonal motifs at small sizes to face-centered cubic character approaching the bulk limit. We identify a crossover particle size of ~35 nm, well below bulk, correlating with a transition from modified-Wulff shapes to pentagonal bipyramids, consistent with finite element predictions. This quantitative framework for mapping size-dependent strain and pseudosymmetry enables precise design and control of functional crystalline solids and phase transformation for catalysis, photonics, electronics, and energy storage.

Lin, Oliver [University of Illinois at Urbana-Cham↗

Cooper minima in high-Z atoms: effects of correlation and relativity on np photoionization

Abstract Photoionization dipole transition matrix elements pass through a zero or attain a minimum that leaves imprints on photoionization parameters like the cross-section, angular distribution asymmetry parameter, phase shift, and photoionization time delay. This minimum is commonly known as the ‘Cooper minimum’ (CM). The CM, in general, is strongly affected by relativistic and correlation effects. Previous works investigated CM in the 6pand 5psubshell photoionization up toZ= 100 using the single-particle Dirac-Slater (DS) method. The present work extends the earlier work toZup to 120 using more accurate methods; Dirac–Hartree–Fock (DHF) which includes the relativistic effects and exchange correlations, and the relativistic random phase approximation (RRPA) which includes both initial and final state electron-electron correlations along with relativistic effects. In addition to the study of photoionization from the 6pand 5psubshells, the 4psubshell has also been investigated in the present work. To demonstrate the prominent effects in the high-Z atoms, Rn (Z= 86), Ra (Z= 88), No (Z= 102), Cn (Z = 112), Og (Z= 118), and Ubn (Z= 120) are investigated.

Optics↗

Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

Abstract In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Fast Ferroelectric L-Band Tuner for ILC Cavities

Design, analysis, and low-power tests are described on a 1.3 GHz ferroelectric tuner that could find application in the International Linear Collider or in Project X at Fermi National Accelerator Laboratory. The tuner configuration utilizes a three-deck sandwich imbedded in a WR-650 waveguide, in which ferroelectric bars are clamped between conducting plates that allow the tuning bias voltage to be applied. Use of a reduced one-third structure allowed tests of critical parameters of the configuration, including phase shift, loss, and switching speed. Issues that were revealed that require improvement include reducing loss tangent in the ferroelectric material, development of a reliable means of brazing ferroelectric elements to copper parts of the tuner, and simplification of the mechanical design of the configuration.

43 PARTICLE ACCELERATORS↗

TESS Observations of the WASP-121 b Phase Curve

We study the red-optical photometry of the ultrahot Jupiter WASP-121 b as observed by the Transiting Exoplanet Survey Satellite (TESS) and model its atmosphere through a radiative transfer simulation. Given its short orbital period of ∼1.275 days, inflated state, and bright host star, WASP-121 b is exceptionally favorable for detailed atmospheric characterization. Toward this purpose, we use allesfitter to characterize its full red-optical phase curve, including the planetary phase modulation and secondary eclipse. We measure the day- and nightside brightness temperatures in the TESS passband as 3012{sub −42}{sup +40} and 2022{sub −602}{sup +254} K, respectively, and do not find a statistically significant phase shift between the brightest and substellar points. This is consistent with inefficient heat recirculation on the planet. We then perform an atmospheric retrieval analysis to infer the dayside atmospheric properties of WASP-121 b, such as its bulk composition, albedo, and heat recirculation. We confirm the temperature inversion in the atmosphere and suggest H{sup −}, TiO, and VO as potential causes of the inversion, absorbing heat at optical wavelengths at low pressures. Future Hubble Space Telescope and James Webb Space Telescope observations of WASP-121 b will benefit from its first full phase curve measured by TESS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guided Self-Assembly and Control of Vortices in Ensembles of Active Magnetic Rollers

Active magnetic colloids are capable of rich collective behavior and complex self-organization. The interplay between short- and long-range interactions taking place away from equilibrium often results in a spontaneous formation of localized dynamic microstructures. Here we report a method for guided self-assembly and control of self-organized colloidal vortices emerging in a ferromagnetic particle ensemble energized by a uniaxial alternating (ac) magnetic field. The structure of a vortex composed of rolling magnetic particles can be stabilized and manipulated by means of an additional strongly localized alternating magnetic field provided by a minicoil. By tuning the parameters of the localized field, we effectively control the dimensions and particle number density in the vortex. We find that the roller vortex self-organization is assisted by field-induced magnetic "steering" rather than magnetic field gradients and is only possible while the system is in the active (magnetic rollers) state. In this work, we demonstrate that parameters of the emergent vortex are efficiently tuned by a phase shift between alternating magnetic fields. Overall, the method for assisted self-organization of rolling magnetic colloids into a vortex with on-demand characteristics suggests a new tool for active matter control and manipulation that may lead to a development of new approaches toward the guided microscopic transport in active particle systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗