SEARCH · Search NASA
Results for “Portable”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Solid State Ionics - the key to the discovery, introduction and domination of lithium batteries for portable energy storage
2017 is the 50th anniversary of the discovery of fast ion transport in β-alumina. This discovery led to a revolution in the study of solid materials that might exhibit ionic motion as fast as that found in liquids. The need for materials with both fast ionic and electronic conductivity and a wide stoichiometry range to measure the ionic conductivity of beta alumina led to the intercalation concept for rechargeable alkali metal batteries. These discoveries and the resulting development of the lithium battery are described in this paper.
Fundamental Insight into Humid CO 2 Uptake in Direct Air Capture Nanocomposites Using Fluorescence and Portable NMR Relaxometry
Not Available
in situU(VI) Bioremediation with a Field-Portable Microarray Analysis System
Explore the source record for details and available documents.
Identification and Confirmation of Fentanyls on Paper using Portable Surface Enhanced Raman Spectroscopy and Paper Spray Ionization Mass Spectrometry
Not provided.
To Exascale and Beyond—The Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM), a Performance Portable Global Atmosphere Model for Cloud-Resolving Scales
The new generation of heterogeneous CPU/GPU computer systems offer much greater computational performance but are not yet widely used for climate modeling. One reason for this is that traditional climate models were written before GPUs were available and would require an extensive overhaul to run on these new machines. In addition, even conventional “high–resolution” simulations don't currently provide enough parallel work to keep GPUs busy, so the benefits of such overhaul would be limited for the types of simulations climate scientists are accustomed to. The vision of the Simple Cloud-Resolving Energy Exascale Earth System (E3SM) Atmosphere Model (SCREAM) project is to create a global atmospheric model with the architecture to efficiently use GPUs and horizontal resolution sufficient to fully take advantage of GPU parallelism. After 5 years of model development, SCREAM is finally ready for use. In this paper, we describe the design of this new code, its performance on both CPU and heterogeneous machines, and its ability to simulate real-world climate via a set of four 40 day simulations covering all 4 seasons of the year.
Characterizing the portability of phage-encoded homologous recombination proteins
Not provided.
Development of a portable high-T c spherical neutron polarimetry device at the Oak Ridge National Laboratory
Spherical neutron polarimetry is a powerful polarized neutron scattering technique used to determine complex magnetic structures which are only partly accessible by other methods. This technique measures the full neutron polarization change upon scattering from a sample by fully decoupling the incoming and outgoing neutron polarization with a zero-field chamber placed at the sample position. Recent advancements and testing are presented for a new spherical neutron polarimetry device utilizing high-T c superconducting YBCO films, PHiTPAD, at the High Flux Isotope Reactor at Oak Ridge National Laboratory. Furthermore, we introduce a conceptual design that utilizes wavelength-independent adiabatic transitions to adapt spherical neutron polarimetry for use with pulsed neutron sources, thereby expanding its potential applications in neutron scattering research.
Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope
Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.
Ultrasensitive multi-species detection of CRISPR-Cas9 by a portable centrifugal microfluidic platform
The discovery of the RNA-guided DNA nuclease CRISPR-Cas9 has enabled the targeted editing of genomes from diverse organisms, but the permanent and inheritable nature of genome modification also poses immense risks. The potential for accidental exposure, malicious use, or undesirable persistence of Cas9 therapeutics and off-target genome effects highlight the need for detection assays. Here we report a centrifugal microfluidic platform for the measurement of both Cas9 protein levels and nuclease activity. Because Cas9 from many bacterial species have been adapted for biotechnology applications, we developed the capability to detect Cas9 from the widely-used S. pyogenes, as well as S. aureus, N. meningitidis, and S. thermophilus using commercially-available antibodies. Further, we show that the phage-derived anti-CRISPR protein AcrIIC1, which binds to Cas9 from several species, can be used as a capture reagent to broaden the species range of detection. Finally, as genome modification generally requires Cas9 nuclease activity, a fluorescence-based sedimentation nuclease assay was also incorporated to allow the sensitive and simultaneous measurement of both Cas9 protein and activity in a single biological sample.
Comparison of machine learning techniques to optimize the analysis of plutonium surrogate material via a portable LIBS device
The utilization of machine learning techniques has become commonplace in the analysis of optical emission spectra. These methods are often limited to variants of principal components analysis (PCA), partial-least squares (PLS), and artificial neural networks (ANNs). A plethora of other techniques exist and are well established in the world of data science, yet are seldom investigated for their use in spectroscopic problems. In this study, machine learning techniques were used to analyze optical emission spectra of laser-induced plasma from ceria pellets doped with silicon in order to predict silicon content. Additionally, a boosted regression ensemble model was created, and its predictive accuracy was compared to that of traditional PCA, PLS, and ANN regression models. Boosted regression tree ensembles yielded fits with R-squared (R2) values as high as 0.964 and mean-squared errors of prediction (MSEPs) as low as 0.074, providing the most accurate predictive model. Neural networks performed with slightly lower R2 values and higher MSEPs compared to the ensemble methods, thus indicating susceptibility to overfitting.
A new portable random number generator wrapper library
Random number generator is an important component of many scientific projects. Many projects are written using programming models (like OpenMP and SYCL) to target different architectures. However, some programming models do not provide a random number generator. In this work, we introduce our random number generator wrapper. It is a header-only library that supports three distributions of random numbers: uniform, normal, and poisson. On the GPU backend, it wraps the cuRAND and rocRAND library, and supports various random number engines. It also wraps random123, a counterbased random number generator, on both CPU and GPU. With this library, we can generate random numbers with a few lines of code and target both GPU and multi-thread CPU with the same code. We also investigate the performance and scalability of this wrapper on different architectures with different engines and the number of cores.
Portable x-ray fluorescence spectrometer for coating thickness measurement
A handheld x-ray spectrometer has been realized and tested. The purpose of the device is to measure the thickness of coated samples in the range of 1-1500 nm in an industrial environment. Accuracy of {approx}3% has been achieved in this range with a measurement time of 1 min. Automated software has been implemented to allow utilization by a nonspecialist operator. An automated calibration procedure, based on measurements of reference samples, is used.
Portable laser-heating stand for synchrotron applications
A compact, double-sided laser-heating system for diamond-cell synchrotron applications is described. The optical table, containing laser, spectrometer, and all optics for visual observation and measuring temperatures and pressures has an area of less than (1/2) m{sup 2} and weighs less than 20 kg. All components can be remotely controlled at micron levels with simple dc motors and pneumatic drives. The design allows quick alignment of the laser-heated hot spot with the x-ray beam and the spectrometer. The prealigned system can be set up at most synchrotron beamlines within about 1 h. We carried out measurements on a variety of materials above one megabar and up to over 4000 K at both the x-ray diffraction beamline ID 27 and the x-ray absorption beamline ID 24 at the European Synchrotron Facility. A new measurement of the melting temperature of iron by x-ray absorption spectroscopy is presented.
Contributed Review: The feasibility of a fully miniaturized magneto-optical trap for portable ultracold quantum technology
Experiments using laser cooled atoms and ions show real promise for practical applications in quantum-enhanced metrology, timing, navigation, and sensing as well as exotic roles in quantum computing, networking, and simulation. The heart of many of these experiments has been translated to microfabricated platforms known as atom chips whose construction readily lend themselves to integration with larger systems and future mass production. To truly make the jump from laboratory demonstrations to practical, rugged devices, the complex surrounding infrastructure (including vacuum systems, optics, and lasers) also needs to be miniaturized and integrated. In this paper we explore the feasibility of applying this approach to the Magneto-Optical Trap; incorporating the vacuum system, atom source and optical geometry into a permanently sealed micro-litre system capable of maintaining 10{sup −10} mbar for more than 1000 days of operation with passive pumping alone. We demonstrate such an engineering challenge is achievable using recent advances in semiconductor microfabrication techniques and materials.
Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines
A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.