Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Imaging of sub-wavelength structures radiating coherently near microspheres

Using a two-dimensional model, we show that the optical images of a sub-wavelength object depend strongly on the excitation of its electromagnetic modes. There exist modes that enable the resolution of the object features smaller than the classical diffraction limit, in particular, due to the destructive interference. We propose to use such modes for super-resolution of resonant structures such as coupled cavities, metal dimers, or bowties. A dielectric microsphere in contact with the object forms its magnified image in a wide range of the virtual image plane positions. It is also suggested that the resonances may significantly affect the resolution quantification in recent experimental studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New two-dimensional photon camera

A photon-sensitive camera, applicable to speckle imaging of astronomical sources, high-resolution spectroscopy of faint galaxies in a crossed-dispersion spectrograph, or narrow-band direct imaging of galaxies, is presented. The camera is shown to supply 8-bit by 8-bit photon positions (256 x 256 pixels) for as many as 10 to the 6th photons/sec with a maximum linear resolution of approximately 10 microns. The sequence of photon positions is recorded digitally with a VHS-format video tape recorder or formed into an immediate image via a microcomputer. The four basic elements of the camera are described in detail: a high-gain image intensifier with fast-decay output phosphor, a glass-prism optical-beam splitter, a set of Gray-coded masks, and a photomultiplier tube for each mask. The characteristics of the camera are compared to those of other photon cameras.

Papaliolios, C.↗

Simple and efficient relaxation methods for interfaces separating compressible fluids, cavitating flows and shocks in multiphase mixtures

Numerical approximation of the five-equation two-phase flow of Kapila et al. [A.K. Kapila, R. Menikoff, J.B. Bdzil, S.F. Son, D.S. Stewart, Two-phase modeling of deflagration-to-detonation transition in granular materials: reduced equations, Physics of Fluids 13(10) (2001) 3002-3024] is examined. This model has shown excellent capabilities for the numerical resolution of interfaces separating compressible fluids as well as wave propagation in compressible mixtures [A. Murrone, H. Guillard, A five equation reduced model for compressible two phase flow problems, Journal of Computational Physics 202(2) (2005) 664-698; R. Abgrall, V. Perrier, Asymptotic expansion of a multiscale numerical scheme for compressible multiphase flows, SIAM Journal of Multiscale and Modeling and Simulation (5) (2006) 84-115; F. Petitpas, E. Franquet, R. Saurel, O. Le Metayer, A relaxation-projection method for compressible flows. Part II. The artificial heat exchange for multiphase shocks, Journal of Computational Physics 225(2) (2007) 2214-2248]. However, its numerical approximation poses some serious difficulties. Among them, the non-monotonic behavior of the sound speed causes inaccuracies in wave's transmission across interfaces. Moreover, volume fraction variation across acoustic waves results in difficulties for the Riemann problem resolution, and in particular for the derivation of approximate solvers. Volume fraction positivity in the presence of shocks or strong expansion waves is another issue resulting in lack of robustness. To circumvent these difficulties, the pressure equilibrium assumption is relaxed and a pressure non-equilibrium model is developed. It results in a single velocity, non-conservative hyperbolic model with two energy equations involving relaxation terms. It fulfills the equation of state and energy conservation on both sides of interfaces and guarantees correct transmission of shocks across them. This formulation considerably simplifies numerical resolution. Following a strategy developed previously for another flow model [R. Saurel, R. Abgrall, A multiphase Godunov method for multifluid and multiphase flows, Journal of Computational Physics 150 (1999) 425-467], the hyperbolic part is first solved without relaxation terms with a simple, fast and robust algorithm, valid for unstructured meshes. Second, stiff relaxation terms are solved with a Newton method that also guarantees positivity and robustness. The algorithm and model are compared to exact solutions of the Euler equations as well as solutions of the five-equation model under extreme flow conditions, for interface computation and cavitating flows involving dynamics appearance of interfaces. In order to deal with correct dynamic of shock waves propagating through multiphase mixtures, the artificial heat exchange method of Petitpas et al. [F. Petitpas, E. Franquet, R. Saurel, O. Le Metayer, A relaxation-projection method for compressible flows. Part II. The artificial heat exchange for multiphase shocks, Journal of Computational Physics 225(2) (2007) 2214-2248] is adapted to the present formulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Offshore wind speed estimates from a high‐resolution rapidly updating numerical weather prediction model forecast dataset

Abstract In association with the Department of Energy–funded Position of Offshore Wind Energy Resources (POWER) project, we present results from compositing a 3‐year dataset of 80‐m (above ground level) wind forecasts from the 3‐km High‐Resolution Rapid Refresh (HRRR) model over offshore regions for the contiguous United States. The HRRR numerical weather prediction system runs once an hour and features hourly data assimilation, providing a key advantage over previous model‐based offshore wind datasets. On the basis of 1‐hour forecasts from the HRRR model, we highlight the different climatological regimes of the nearshore environment, characterizing the mean 80‐m wind speed as well as the frequency of exceeding 4, 12, and 25 m s −1 for east and west coast, Gulf of Mexico, and Great Lake locations. Preliminary verification against buoy measurements demonstrates good agreement with observations. This dataset can inform the placement of targeted measurement systems in support of improving resource assessments and wind forecasts to advance offshore wind energy goals both in New England and other coastal regions of the United States.

James, Eric P.↗

Five degree-of-freedom control of an ultra-precision magnetically-suspended linear bearing

The authors constructed a high precision linear bearing. A 10.7 kg platen measuring 125 mm by 125 mm by 350 mm is suspended and controlled in five degrees of freedom by seven electromagnets. The position of the platen is measured by five capacitive probes which have nanometer resolution. The suspension acts as a linear bearing, allowing linear travel of 50 mm in the sixth degree of freedom. In the laboratory, this bearing system has demonstrated position stability of 5 nm peak-to-peak. This is believed to be the highest position stability yet demonstrated in a magnetic suspension system. Performance at this level confirms that magnetic suspensions can address motion control requirements at the nanometer level. The experimental effort associated with this linear bearing system is described. Major topics are the development of models for the suspension, implementation of control algorithms, and measurement of the actual bearing performance. Suggestions for the future improvement of the bearing system are given.

Trumper, David L.↗

Obtaining One-Degree Accuracy With Shaft Encoders

Circuit converts output of 1-pulse-per-revolution shaft encoder to precise 360-pulses-per-revolution output. Circuit allows shaft angular position to be measured with 1-degree accuracy. With simple modifications, circuit provides higher or lower resolution from single- or multiple-pulse-perrevolution sources. Circuit used to synchronize aircraft beacon transponder-based plan-position indicator (PPI) display to remote host interrogator search antenna. Constructed using standard, commercially available components.

Franke, J. M.↗

Subpixel Resolution In Depth Perceived Via 3-D Television

Report describes experiment in which two black vertical bars on featureless white background placed near intersection of optical axes of two charge-coupled-device video cameras positioned to give stereoscopic views. Trained human observers found to perceive depths at subpixel resolutions in stereoscopic television images. This finding significant for remote stereoscopic monitoring, expecially during precise maneuvers of remotely controlled manipulators. Also significant for research in processing of visual information by human brain.

Diner, Daniel B.↗

Evolutionary determination of experimental parameters for ptychographical imaging

The Ptychographical Iterative Engine (PIE) algorithm is a recently developed novel method of Coherent Diffractive Imaging (CDI) that uses multiple overlapping diffraction patterns to reconstruct an image. This method has successfully produced high quality reconstructions at both optical and X-ray wavelengths but the need for accurate knowledge of the probe positions is currently a limiting factor in the production of high resolution reconstructions at electron wavelengths. This paper examines the shape of the search landscape for producing optimal image reconstructions in the specific case of electron microscopy and then shows how evolutionary search methods can be used to reliably determine experimental parameters in the electron microscopy case (such as the spherical aberration in the probe and the probe positions).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry

Transient signal responses for ablated samples as a function of particle size and laser parameters are characterized. Data are acquired with time resolution of 5 or 6 ms per data point. Large positive spikes in signal are observed and increase in both amplitude and frequency with increasing particle size. Particle sizes are selected using a differential mobility analyzer. Spikes in the signal also increase with decreasing laser rastering rates. A comparison of lasers with pulse widths of 370 fs and 5 ns shows that shortening the pulse width significantly reduces the frequency and amplitude of positive spikes in signal. These large positive spikes are attributed to the vaporization, atomization, and ionization of individual large intact particles, which are considered to be a major cause of fractionation in laser ablation ICP-MS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras

Purpose: The authors investigated how the characteristics of the detectors used in a three-stage Compton camera (CC) affect the CC's ability to accurately measure the emission distribution and energy spectrum of prompt gammas (PG) emitted by nuclear de-excitations during proton therapy. The detector characteristics they studied included the material (high-purity germanium [HPGe] and cadmium zinc telluride [CZT]), Doppler broadening (DB), and resolution (lateral, depth, and energy). Methods: The authors simulated three-stage HPGe and CZT CCs of various configurations, detecting gammas from point sources with energies ranging from 0.511 to 7.12 MeV. They also simulated a proton pencil beam irradiating a tissue target to study how the detector characteristics affect the PG data measured by CCs in a clinical proton therapy setting. They used three figures of merit: the distance of closest approach (DCA) and the point of closest approach (PCA) between the measured and actual position of the PG emission origin, and the calculated energy resolution. Results: For CCs with HPGe detectors, DB caused the DCA to be greater than 3 mm for 14% of the 6.13 MeV gammas and 20% of the 0.511 MeV gammas. For CCs with CZT detectors, DB caused the DCA to be greater than 3 mm for 18% of the 6.13 MeV gammas and 25% of the 0.511 MeV gammas. The full width at half maximum (FWHM) of the PCA in the z-caret direction for HPGe and CZT detectors ranged from 1.3 to 0.4 mm for gammas with incident energy ranging from 0.511 to 7.12 MeV. For CCs composed of HPGe detectors, the resolution of incident gamma energy calculated by the CC ranged from 6% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For CCs composed of CZT detectors, the resolution of gamma energy calculated by the CC ranged from 10% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For HPGe and CZT CCs in which all detector effect were included, the DCA was less than 3 mm for 75% and 68% of the detected gammas, respectively, and restricting gammas to those having energy greater than 2.0 MeV increased these percentages to 83% and 77% for HPGe and CZT, respectively. Distributions of the true gamma origins and the PCA after detector characteristics had been included showed good agreement on beam range and some loss of resolution for the lateral profile of the PG emission. Characteristic energy lines were evident in the calculated gamma energy spectrum. Conclusions: The authors found the following: (1) DB is the dominant source of spatial and energy resolution loss in the CCs at all energy levels; (2) the largest difference in the spatial resolution of HPGe and CZT CCs is that the spatial resolution distributions of CZT have broader tails. The differences in the FWHM of these distributions are small; (3) the energy resolution of both HPGe and CZT three-stage CCs is adequate for PG spectroscopy; and (4) restricting the gammas to those having energy greater than 2.0 MeV can improve the achievable image resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative validation of Ames IR intensity and new line lists for (32/33/34)S(16)O2, (32)S(18)O2 and (16)O(32)S(18)O

The quality of Ames-296K SO2 Infrared (IR) line list intensities is first validated by quantitative exploration of several dipole moment surfaces (DMSs) and partition sum convergence. The DMSs are computed with several of Dunning’s correlation-consistent basis sets and their vibrational dependence are compared to the empirical model derived from Stark effect experiments reported by D. Patel, D. Margolese, and T.R. Dykea [J.Chem.Phys. 70, 2740 (1979)]. The effective dipole deviations from the DMS adopted in the Ames IR lists is 0.2-0.4% for vibrational states up to 3v3. The vibrational dependence of the dipole moment is also in good agreement, except for nv1. Partition sum convergence at 296K is confirmed by new calculations with rotational quantum number J up to 150 and upper state E’ up to 8000 cm-1. The isotopologue consistency of the Ames IR line lists is superior relative to the regular Effective Hamiltonian (EH) models and Effective Dipole Moment (EDM) models. The v1+v2 and v2+v3 intensity consistency check reveals the recently reported experimental intensities need significant improvement or re-analysis. After the accuracy, convergence, and isotopologue consistency have been confirmed, the theoretical Ames-296K intensities are combined with the experimental line positions or EH models that experimental spectroscopists published after 2009. Three high-resolution IR line sets are reported for the (32/33/34)S(16)O2, (32)S(18)O2 and (16)O(32)S(18)O isotopologues: (1) the “New Lines Sets” include experimentally measured line positions; (2) the “Expanded Line Sets” include possible transitions among new rovibrational levels assigned in experiments and ground state (GS) levels predicted by reliable EH models; (3) the “Ames + MARVEL Sets” include possible transitions among all those levels reported in a recent MARVEL analysis. [Tóbiás et al, JQSRT 208, 152 (2018)]. Compared to the limited data in High-resolution TRANsmission molecular absorption database (HITRAN), these line sets have significantly improved the data coverage up to 4000 cm-1. Some missing bands can be traced to the unpublished experimental data. The isotopologue consistency of these line sets will help identify the uncertainties and defects in the experimental EH and EDM models. These line sets are good candidates for the next HITRAN update, if line shape parameters are available. The line sets can be downloaded from supplementary files or from the Ames Molecular Spectroscopic Database at http://huang.seti.org.

Xinchuan Huang↗

Resolution of the Electron Microscope at the Atomic Scale

The importance of atomic-resolution electron microscopy as a tool for structure analysis lies in its ability to produce images in which each peak corresponds to the position of an atom (or atomic column) within the specimen. Being able to distinguish between atoms (or columns) that appear close together when projected in the chosen viewing direction depends on the resolution of the microscope. Knowledge of the resolution of any particular electron microscope is crucial to judge if its resolution is appropriate for the specimen. In addition, resolution quality will determine the precision of measured atom positions.

A-OK↗

Stabilization of ZnMnO3 Phase from Sol-gel Synthesized Nitrate Precursors

The stabilization and analysis of pure ZnMnO3 spinel phase may help to understand the solubility limits of Mn in ZnO in wurtzite and spinel cubic structures. In this report, synthesis and characterization of stable ZnMnO3 phase is discussed which is extracted from sol-gel synthesis of zinc and manganese nitrate precursors. The reflections at higher diffraction angles for this known cubic system with space group Fd3m were calculated with the help of JADE 8.0 program. High resolution X-ray photoelectron spectroscopy measurements of Mn3p position of ZnMnO3 compared with ZnMn2O4 showed a higher binding energy shift ~0.85 eV indicating Mn4+ valence state in ZnMnO3.

36 MATERIALS SCIENCE↗

The differnces between bond lengths in biogenic and geologocal calcite.

We used high-resolution neutron powder diffraction to accurately measure the atomic positions and bond lengths in biogenic and geological calcite. A special procedure for data analysis was developed in order to take into account the considerable amounts of magnesium present in all the investigated samples. As a result, in biogenic calcite we found some atomic bonds to have significantly different lengths as compared to those in geological calcite, after the contribution of magnesium is accounted for. The maximum effect (elongation up to 0.7%) was found for the C-O bonds. We also analyzed changes in frequencies and spectral widths of normal vibrations of carbonate groups in biogenic calcite (as compared to geological calcite) measured by Raman and Fourier transform IR techniques. Surprisingly, the frequency shifts after subtracting the magnesium contribution are close to zero. At the same time, substantial spectral broadening (up to 1.2%) in biogenic calcite as compared to geological samples was detected. Possible explanations for the experimental findings are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray reduction imaging of inclined reflective masks at critical angles

We have proposed and simulated optical schemes for producing reduced images by X-ray lasers or harmonic generators at a wavelength of ∼14 nm. The mask in this case is placed at a small angle to the optical axis, corresponding to the angle of total external reflection of the material. We have determined the optimal position of the detector (resist) and the corresponding spatial resolution. The results can be used to solve problems in nanotechnology and nanostructuring of surfaces. (x-ray optics)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A HIGH-RESOLUTION MASS MAP OF GALAXY CLUSTER SUBSTRUCTURE: LensPerfect ANALYSIS OF A1689

We present a strong lensing (SL) mass model of A1689 which resolves substructures an estimated 25 kpc across within the central {approx}400 kpc diameter. We achieve this resolution by perfectly reproducing the observed (strongly lensed) input positions of 168 multiple images of 55 knots residing within 135 images of 42 galaxies. Our model makes no assumptions about light tracing mass, yet we reproduce the brightest visible structures with some slight deviations. A1689 remains one of the strongest known lenses on the sky, with an Einstein radius of R{sub E} = 47.''0 {+-} 1.''2 (143{sup +3}{sub -4} kpc) for a lensed source at z{sub s} = 2. We find that a single Navarro-Frenk-White (NFW) or Sersic profile yields a good fit simultaneously (with only slight tension) to both our SL mass model and published weak lensing (WL) measurements at larger radius (out to the virial radius). According to this NFW fit, A1689 has a mass of M{sub vir} = 2.0{sup +0.5}{sub -0.3} x 10{sup 15} M{sub sun} h {sup -1}{sub 70} (M{sub 200} = 1.8{sup +0.4}{sub -0.3} x 10{sup 15} M{sub sun} h {sup -1}{sub 70}) within the virial radius r{sub vir} = 3.0 {+-} 0.2 Mpc h {sup -1}{sub 70} (r{sub 200} = 2.4{sup +0.1}{sub -0.2} Mpc h {sup -1}{sub 70}), and a central concentration c{sub vir} = 11.5{sup +1.5}{sub -1.4} (c{sub 200} = 9.2 {+-} 1.2). Our SL model prefers slightly higher concentrations than previous SL models, bringing our SL + WL constraints in line with other recent derivations. Our results support those of previous studies which find A1689 has either an anomalously large concentration or significant extra mass along the line of sight (perhaps in part due to triaxiality). If clusters are generally found to have higher concentrations than realized in simulations, this could indicate that they formed earlier, perhaps as a result of early dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗