Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

PHELIX

The Precision, High-Energy density, Liner Implosion Experiment (PHELIX) pulsed power driver is currently under development at Los Alamos National Laboratory. When operational PHELIX will provide 0.5-1.0 MJ of capacitively stored energy into cm size liners that will reach implosion velocities of 1-4 km/s with approximately 10-20 microsecond implosion time. Peak load currents will be in the 5-10 megaamp range. To do this the machine employs a reusable, multi-turn primary, single-turn secondary transformer to couple the 100-120 kV Marx capacitor system to the load. The transformer has been designed toward a coupling coefficient of 0.9. PHELIX is designed to be portable with only an 8 x 25 ft{sup 2} footprint. This will allow the machine to be taken to the experiment designer's diagnostic of choice. The first such diagnostic will be the LANL proton-radiography facility. There the multi-frame, high-resolution, imaging capability will be used to study hydrodynamic and material phenomena.

43 PARTICLE ACCELERATORS↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

A microwave-pumped slab CO{sub 2} laser

The radiation parameters of a diffusion-cooled compact slab CO{sub 2} laser pumped by microwave discharge at a frequency of 2.45 GHz are studied. A magnetron from a domestic microwave oven is used as the pump source. An average output power of 25 W and an efficiency of {approx}13% are obtained at a wavelength 10.6 {mu}m. A peak output power of 580 W is achieved for 20-{mu}s pulses emitted at a pulse repetition rate of 400 Hz. The dependence of parameters of the CO{sub 2} laser on the input pulse power in the range 0.8-8 kW, the composition and pressure of the working mixture and the pump pulse duration and repetition rate are studied experimentally. Optimal relations between these parameters are determined for the given design of the laser. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft x-ray power diagnostics for fusion experiments at NIF, Omega, and Z facilities

Here, in this Review Article, we discuss a range of soft x-ray power diagnostics at inertial confinement fusion (ICF) and pulsed-power fusion facilities. This Review Article describes current hardware and analysis approaches and covers the following methods: x-ray diode arrays, bolometers, transmission grating spectrometers, and associated crystal spectrometers. These systems are fundamental for the diagnosis of ICF experiments, providing a wide range of critical parameters for the evaluation of fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical interferometry of high-energy nanosecond pin-to-pin discharges in atmospheric air

This paper describes the construction and application of an optical-frequency Michelson interferometer for measuring electron number density within high-energy, high-power nanosecond pin-to-pin discharges (>10 mJ pulse energy, >1 MW pulse power). A 21 mJ, 11 ns spark across a 3 mm pin-to-pin electrode gap was analyzed at 7 ns into the discharge to demonstrate the operation of the interferometer. A peak electron density of 2.3 × 10 17 cm −3 was observed at these conditions, and it was consistent with estimates of plasma channel resistance based on V–I measurements. This initial work paves the way for a larger parametric study of the spatial and temporal dynamics of electron number density in nanosecond pin-do-pin discharges under various conditions.

electron number density↗

A new controller for battery-powered electric vehicles

This paper describes the development, under a NASA/DOE contract, of a new concept for efficient and reliable control of battery-powered vehicles. It avoids the detrimental effects of pulsed-power controllers like the SCR 'chopper' by using rotating machines to meter continuous currents to the traction motor. The concept is validated in a proof-of-principle demonstration system and a complete vehicle is simulated on an analog computer. Test results show exceptional promise for a full-scale system. Optimum control strategies to minimize controller weight are developed by means of the simulated vehicle. The design for an Engineering Model is then prepared in the form of a practical, compact two-bearing package with forced air cooling. Predicted performance is outstanding, with controller efficiency of over 90% at high speed.

Belsterling, C. A.↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Overview of Space Technology developed during 1980s ~ present

Early 1980s, a science team of NASA Langley Research has developed various space power systems, especially directly solar-pumped iodine laser (DSPIL), wireless power transmission technology, concepts of solar thermal propulsion, pulse-power for direct-energy weapons (DEW) applications, soft X-ray lithography and to name a few. This presentation will briefly overview these NASA-Langley developed space technology for future applications.

plasma devices↗

RISE/FALL TIME ENHANCEMENT OF THE SPALLATION NEUTRON SOURCE LINAC LEBT CHOPPER SYSTEM

The Spallation Neutron Source (SNS) Linac Low Energy Beam Transport (LEBT) chopper system provides fast chopping of the H- ion beam in the LEBT structure. Four identical pulsed power supplies (pulsers) create a series of 2.5 kV pulses to the four deflection electrodes floating on the focusing voltage of -50 kV. Each pulser is connected to the electrode through the network which consists of high voltage (HV) cables, a blocking capacitor, HV feed-through connectors, current-limiting resistors and transient voltage suppressors. Effective beam chopping requires minimal rise/fall time of the rectangular HV pulses on the load. In the present configuration these values are approximately 100 ns. Methods of reducing rise/fall time on the LEBT electrodes are discussed. Results of simulation and comparative measurements of the original and upgraded system on the test stand are presented. Furthermore, the effect of these changes on reliability degradation caused by arcing in the LEBT structure is discussed.

LEBT chopper↗

Thermal analysis of Test Divertor Unit Scraper Element for Wendelstein 7-X

The Wendelstein-7X stellarator will go through three operational phases, with successively more energy as more complex divertors are installed. The first operational phase operated without a divertor, instead using five limiters (one in each of the five field periods), the second phase uses ten uncooled test divertor units (TDU), and the third will include an actively cooled divertor. Simulations of plasma operation have shown that the evolution of a toroidal current can lead to significant heat fluxes sweeping across sensitive regions in the divertor, possibly exceeding their qualified limit. A “Scraper Element” (SE) has been proposed to protect these sensitive divertor regions. To examine the effectiveness of this high heat-flux SE, a TDU Scraper Element (TDU-SE) is scheduled to operate with the TDU. A thermal analysis has been performed to correlate to measurements to be obtained during operation to evaluate the location and intensity of the convective plasma flux. The analysis will give an understanding of what is occurring at the plasma edge. As a result, it will also allow for a quick evaluation of the safety margin during initial, low power pulses so that the experiment can nimbly move to higher power operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Schlieren Visualization of the Energy Addition by Multi Laser Pulse in Hypersonic Flow

The experimental results of the energy addition by multi laser pulse in Mach 7 hypersonic flow are presented. Two high power pulsed CO{sub 2} TEA lasers (TEA1 5.5 J, TEA2 3.9 J) were assembled sharing the same optical cavity to generate the plasma upstream of a hemispherical model installed in the tunnel test section. The lasers can be triggered with a selectable time delay and in the present report the results obtained with delay between 30 {mu}s and 80 {mu}s are shown. The schlieren technique associated with a high speed camera was used to accomplish the influence of the energy addition in the mitigation of the shock wave formed on the model surface by the hypersonic flow. A piezoelectric pressure transducer was used to obtain the time history of the impact pressure at stagnation point of the model and the pressure reduction could be measured. The total recovery of the shock wave between pulses as well as the prolonged effect of the mitigation without recovery was observed by changing the delay.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma parameters of pulsed-dc discharges in methane used to deposit diamondlike carbon films

Here we approximate the plasma kinetics responsible for diamondlike carbon (DLC) depositions that result from pulsed-dc discharges. The DLC films were deposited at room temperature by plasma-enhanced chemical vapor deposition (PECVD) in a methane (CH{sub 4}) atmosphere at 10 Pa. We compared the plasma characteristics of asymmetric bipolar pulsed-dc discharges at 100 kHz to those produced by a radio frequency (rf) source. The electrical discharges were monitored by a computer-controlled Langmuir probe operating in time-resolved mode. The acquisition system provided the intensity-voltage (I-V) characteristics with a time resolution of 1 mus. This facilitated the discussion of the variation in plasma parameters within a pulse cycle as a function of the pulse waveform and the peak voltage. The electron distribution was clearly divided into high- and low-energy Maxwellian populations of electrons (a bi-Maxwellian population) at the beginning of the negative voltage region of the pulse. We ascribe this to intense stochastic heating due to the rapid advancing of the sheath edge. The hot population had an electron temperature T{sub e}{sup hot} of over 10 eV and an initial low density n{sub e}{sup hot} which decreased to zero. Cold electrons of temperature T{sub e}{sup cold}approx1 eV represented the majority of each discharge. The density of cold electrons n{sub e}{sup cold} showed a monotonic increase over time within the negative pulse, peaking at almost 7x10{sup 10} cm{sup -3}, corresponding to the cooling of the hot electrons. The plasma potential V{sub p} of approx30 V underwent a smooth increase during the pulse and fell at the end of the negative region. Different rates of CH{sub 4} conversion were calculated from the DLC deposition rate. These were explained in terms of the specific activation energy E{sub a} and the conversion factor x{sub dep} associated with the plasma processes. The work deepens our understanding of the advantages of using pulsed power supplies for the PECVD of hard metallic and protective coatings for industrial applications (optics, biomedicine, and electronics).

36 MATERIALS SCIENCE↗

Measuring Magnetic Fields in Collisionless Experiments

Magnetic field and electron density diagnostics are critical tools in the characterization of high energy density laboratory plasmas. These plasma environments are complex and the magnetic fields and electron densities often exhibit significant spatial and temporal variation leading to significant challenges in these measurements. Even the most promising technique, Zeeman splitting, faces challenges under plasma conditions where broadening due to high density and temperature is greater than the Zeeman splitting. Here we propose and describe a diagnostic based on Zeeman broadening. The Zeeman broadening diagnostic relies on measuring the widths of multiplet components simultaneously. The method does not depend on resolved lines, but rather on measuring the difference in the widths of multiplet lines. Experiments were performed at the University of Nevada, Reno, Nevada Terawatt Facility (NTF). The Zeeman broadening diagnostic gathered visible broadened multiplet spectra from laser produced plasmas, and plasmas generated from wire-arrays driven by the Zebra z-pinch pulsed power apparatus. The laser produced plasma, created by the Leopard pulsed laser (I>1014 W/cm 2 ), evolved in an external magnetic field (B<40T) generated by current driven through a solid electrode by the Zebra current pulse. For laser produced plasmas, observation of the magnetic field radial profile showed that the external field completely diffuses into the plasma after approximately 100 ns. Further, as the plasma continues to evolve, the field profiles within the plasma develop modulations that do not map the external field profile. For the wire array experiments, radial electron density, and magnetic field, profiles were measured. Here the Zeeman splitting was not resolved and the magnetic fields were determined from the difference between the widths of the multiplet line profiles. Thus, it has been demonstrated that Zeeman broadening may be used as a magnetic field diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy stores and switches for rail-launcher systems

An overview of existing switch and power supply technology applicable to space launch, a new candidate pulsed power supply for Earth-to-space rail launcher duty, the inverse railgun flux compressor, and a set of switching experiments to study further the feasibility of Earth-to-space launch are discussed.

Weldon, W. F.↗

SENSITIVITY STUDIES OF HEATER ROD DESIGN FOR TRANSIENT CRITICAL HEAT FLUX EXPERIMENTS IN TREAT

An important area of reactor safety is the cladding-to-coolant heat transfer under fast transient conditions. These conditions can occur during events such as a reactivity-initiated accident (RIA). In this paper we present the work performed under a laboratory directed research and development (LDRD) project, headed by Idaho National Laboratory (INL). The goal was to develop a test matrix to inform on the design of a borated steel heater rod that will induce critical heat flux (CHF) within an experimental capsule filled with water, using the TREAT facility, when submitted to a power pulse. The energy deposition in the rod and occurrence of CHF were identified as the most important key Figures of Merit (FoMs) used in the design process. Energy deposition was varied by using different pulse characteristics and various boron concentrations in the rod. A power coupling factor (PCF) was determined for each boron concentration. A sensitivity study determined the lowest limiting PCF needed to induce CHF in water with different degrees of subcooling while keeping pressure constant. Boron concentrations between 0.1-1.54 wt.% were considered. Additionally, the value of CHF is also known to increase during a rapid transient. A CHF multiplier sensitivity study focused on an example case concluded that CHF is no longer exceeded when the value is between 2.6- and 2.9-times higher. Lastly, a self-shielding study was performed to determine whether a borated tube could be used in place of a solid borated rod. The study determined that the inner 1mm of the rod can essentially be excluded or instrumented without heat generation penalties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Power Picosecond Laser Pulse Recirculation

We demonstrate a nonlinear crystal-based short pulse recirculation cavity for trapping the second harmonic of an incident high power laser pulse. This scheme aims to increase the efficiency and flux of Compton-scattering based light sources. We demonstrate up to 36x average power enhancement of frequency doubled sub-millijoule picosecond pulses, and 17x average power enhancement of 177 mJ, 10 ps, 10 Hz pulses.

42 ENGINEERING↗