Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Ultrasonic Testing (UT) Reference Standard for Additive Manufacturing Quality Control

Many additive manufacturing (AM) reference standards for build quality verification concentrate primarily on external features. In contrast, EPRI proposes a pair of AM reference blocks that feature only internal and embedded forms. This report presents, collates, and discusses quantitative nondestructive evaluation (NDE) results from various techniques, including visual testing (VT), radiographic testing (RT), conventional ultrasonic testing (UT), and full matrix capture/total focusing method (FMC/TFM) scanning. The blocks are intended, as part of a larger series of blocks, to evaluate build quality and the relative performance of different NDE techniques in detecting various features. The limits of detectability and the closeness of the as-built shape to the intended form for certain features are quantified, facilitating direct comparison. Upon analysis of the results of this testing, it was found that FMC/TFM was consistently superior in detection, followed by conventional UT, then VT, and lastly RT.

36 MATERIALS SCIENCE↗

Manufacture of particulate reference materials

Methods for forming particulates that are highly consistent with regard to shape, size, and content are described. Particulates are suitable for use as reference materials. Methods can incorporate actinides and/or lanthanides, e.g., uranium, and can be used for forming certified reference materials for use in the nuclear industry. Methods include formation of an aerosol from an oxalate salt solution, in-line diagnostics, and collection of particles of the aerosol either in a liquid impinger or on a solid surface.

Wellons, Matthew S.↗

Enraf reference level updates for high-level nuclear waste tanks at Hanford site - 15705

The United States Department of Energy Hanford Site Tank Farm has implemented a system for monitoring tank waste levels in all single-shell tanks (SST), double-shell tanks (DST) and miscellaneous catch tanks using Enraf Series 854 level gauges. To ensure an accurate computation of the tank waste levels, a precise calculation of the tank reference level must be kept up to date. A system was developed where accurate waste tank reference levels are kept consistent with each Enraf assembly in the Tank Farms to ensure the continuation of accurate waste level monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

230Th-234U Model-Ages of Some Uranium Standard Reference Materials

The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New SCALE Sensitivity/Uncertainty Capabilities Applied to Bias Estimation and to Design of MIRTE Reference Experiments

New TSUNAMI tools of SCALE 6, TSURFER and TSAR, are demonstrated to examine the bias effects of small-worth test materials, relative to reference experiments. TSURFER is a data adjustment bias and bias uncertainty assessment tool, and TSAR computes the sensitivity of the change in reactivity between two systems to the cross-section data common to their calculation. With TSURFER, it is possible to examine biases and bias uncertainties in fine detail. For replacement experiments, the application of TSAR to TSUNAMI-3D sensitivity data for pairs of experiments allows the isolation of sources of bias that could otherwise be obscured by materials with more worth in an individual experiment. The application of TSUNAMI techniques in the design of nine reference experiments for the MIRTE program will allow application of these advanced techniques to data acquired in the experimental series. The validation of all materials in a complex criticality safety application likely requires consolidating information from many different critical experiments. For certain materials, such as structural materials or fission products, only a limited number of critical experiments are available, and the fuel and moderator compositions of the experiments may differ significantly from those of the application. In these cases, it is desirable to extract the computational bias of a specific material from an integral keff measurement and use that information to quantify the bias due to the use of the same material in the application system. Traditional parametric and nonparametric methods are likely to prove poorly suited for such a consolidation of specific data components from a diverse set of experiments. An alternative choice for consolidating specific data from numerous sources is a data adjustment tool, like the ORNL tool TSURFER (Tool for Sensitivity/Uncertainty analysis of Response Functionals using Experimental Results) from SCALE 6.1 However, even with TSURFER, it may be difficult to examine a single experiment and differentiate bias due to a test material from bias due to other materials such as fuel and moderator. An alternative method is to perform two experiments on the same critical assembly, one with and one without the test material, and examine differences in the biases due to the introduction of the test material. Techniques to extract a computational bias from pairs of replacement experiments and project that bias, with an associated bias uncertainty, to an application system are described herein.

36 MATERIALS SCIENCE↗

ESTIMATION UNCERTAINTY IN THE DETERMINATION OF THE MASTER CURVE REFERENCE TEMPERATURE

The Master Curve Reference Temperature, T0, characterizes the fracture performance of structural steels in the ductile-to-brittle transition region. For a given material, this reference temperature is estimated via fracture toughness testing. A methodology is presented to compute the standard error of an estimated T0 value from a finite sample of toughness data, in a unified manner for both single temperature and multiple temperature test methods. Using the asymptotic properties of maximum likelihood estimators, closed-form expressions for the standard error of the estimate of T0 are presented for both test methods. This methodology includes statistically rigorous treatment of censored data, which represents an advance over the current ASTM E1921 methodology. Through Monte Carlo simulations of realistic single temperature and multiple temperature test plans, the recommended likelihood-based procedure is shown to provide better statistical performance than the methods in the ASTM E1921 standard.

36 MATERIALS SCIENCE↗

Feasibility studies to establish at the Kazakhstan Ulba metallurgical plant the manufacturing capability to produce low-enriched uranium certified reference materials

One of the salient features of the transition plan that the United States Department of Energy/National Nuclear Security Administration (DOE/NNSA) is presently implementing in the Former Soviet Union countries is the availability of uranium certified reference materials for calibration of nondestructive assay (NDA) measurement equipment. To address this challenge, DOE/NNSA and U.S. national laboratories have focused their cooperative efforts on establishing a reliable source for manufacturing, certifying, and supplying of such standards. The Ulba Metallurgical Plant (UMP), Kazakhstan, which processes large quantities of low-enriched uranium to produce ceramic fuel pellets for nuclear-powered reactors, is well situated to become a key supplier of low-enriched uranium certified reference materials for the country and Central Asia region. We have recently completed Phase I of a feasibility study to establish at UMP capabilities of manufacturing these standards. In this paper we will discuss details of a proposed methodology for uranium down-blending, material selection and characterization, and a proposed methodology of measurement by destructive (DA) and non-destructive (NDA) analysis to form a database for material certification by the competent State authorities in the Republic of Kazakhstan. In addition, we will discuss the prospect for manufacturing of such standards at UMP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reference Architecture Discussion [Slides]

NREL is developing reference architectures - industry-validated and verified models - to provide a common operational view and emulation environment for analyzing risk to the energy sector. In this presentation, we overview our work in developing these architectures.

97 MATHEMATICS AND COMPUTING↗

Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg∙m -3 to 180 kg∙m -3 , and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ, T) = α 0 + α 1 ρ +α 2 T + α 3 T 3 +α 4 e - ($\frac{T-a_{5}}{a_{6}}$) 2 = where λ(ρ,T) is the predicted thermal conductivity (W∙m -1 ∙K -1 ), ρ is the bulk density (kg∙m -3 ), T is the mean temperature (K) and $a_i$ (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ, T) = α 0 + α 1 ρ +α 2 T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

regression analysis↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Ka-band (8.4/32 GHz) has been constructed using fifty-one 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec in a cos delta and 290 micro-arcsec in delta. There is evidence for zonal errors at the 100 micro-arcsec level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

reference systems catalog↗

Use of Reference Frames for Interplanetary Navigation at JPL

Navigation of interplanetary spacecraft is typically based on range, Doppler, and differential interferometric measurements made by ground-based telescopes. Acquisition and interpretation of these observations requires accurate knowledge of the terrestrial reference frame and its orientation with respect to the celestial frame. Work is underway at JPL to reprocess historical VLBI and GPS data to improve realizations of the terrestrial and celestial frames. Improvements include minimal constraint alignment, improved tropospheric modeling, better orbit determination, and corrections for antenna phase center patterns.

International Celestial Reference Frame (ICRF)↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Kaband (8.4/32 GHz) has been constructed using fiftyone 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec ( mu as) in alpha cos delta and 290 mu as in delta. There is evidence for zonal errors at the 100 mu as level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

interferometry↗

Jupiter Global Reference Atmospheric Model (Jupiter-GRAM): User Guide

This Technical Memorandum (TM) presents the Jupiter Global Reference Atmospheric Model (Jupiter-GRAM) and the updated features of the GRAMs. Jupiter-GRAM is an engineering-oriented atmospheric model that estimates mean values of atmospheric properties for Jupiter. This TM summarizes the atmospheric data model in Jupiter-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Jupiter-GRAM input and output files and how to interpret Jupiter-GRAM results are also provided.

atmospheric models↗

Earth Global Reference Atmospheric Model (Earth-GRAM): User Guide

This Technical Memorandum (TM) presents the Earth Global Reference Atmospheric Model (Earth-GRAM) and the updated features of the GRAMs. Earth-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Earth. This TM summarizes the atmospheric data model in Earth-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Earth-GRAM input and output files and how to interpret Earth-GRAM results are also provided.

Atmospheric Models↗

Venus Global Reference Atmospheric Model (Venus-GRAM): User Guide

This Technical Memorandum (TM) presents the Venus Global Reference Atmospheric Model (Venus-GRAM) and the updated features of the GRAMs. Venus-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Venus. This TM summarizes the atmospheric data model in Venus-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Venus-GRAM input and output files and how to interpret Venus-GRAM results are also provided.

atmospheric models↗

Mars Global Reference Atmospheric Model (Mars-GRAM): User Guide

This Technical Memorandum (TM) presents the Mars Global Reference Atmospheric Model (Mars-GRAM) and the updated features of the GRAMs. Mars-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Mars. This TM summarizes the atmospheric data model in Mars-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Mars-GRAM input and output files and how to interpret Mars-GRAM results are also provided.

atmospheric models↗

Mars Global Reference Atmospheric Model (Mars-GRAM) 2024: User Guide

This Technical Memorandum (TM) presents the Mars Global Reference Atmospheric Model (Mars-GRAM) 2024 and its updated features. Mars-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Mars. This TM summarizes the atmospheric data model in Mars-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Mars-GRAM input and output files and how to interpret Mars-GRAM results are also provided.

atmospheric density↗