Search NASA⌕ Search

SEARCH · Search NASA

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SU-D-204-07: Comparison of AAPM TG150 Draft Image Receptor Tests with Vendor Automated QC Tests for Five Mobile DR Units

Purpose: To determine the consistency of digital detector (DR) tests recommended by AAPM TG150 and tests provided by commercially available DirectView Total Quality Tool (TQT). Methods: The DR tests recommended by the TG150 Detector Subgroup[1] were performed on 4 new Carestream DRX-Revolution and one Carestream DRX1C retrofit of a GE AMX-4 that had been in service for three years. After detector calibration, flat-field images plus images of two bar patterns oriented parallel and perpendicular to the A-C axis, were acquired at conditions recommended by TG150. Raw images were harvested and then analyzed using a MATLAB software previously validated[2,3,4]. Data were analyzed using ROIs of two different dimensions: 1) 128 x 128 ROIs matching the detector electronics; and 2) 256 x 256 ROIs, each including 4 adjacent smaller ROIs. TG150 metrics from 128 x 128 ROIs were compared to TQT metrics, which are also obtained from 128 x 128 ROIs[5]. Results: The results show that both TG150 and TQT measurements were consistent among these detectors. Differences between TG150 and TQT values appear systematic. Compared with 128 x 128 ROIs, noise and SNR non-uniformity were lower with 256 x 256 ROIs, although signal non-uniformity was similar, indicating detectors were appropriately calibrated for gain and offset. MTF of the retrofit unit remained essentially the same between 2012 and 2015, but was inferior to the new units. The older generator focal spot is smaller (0.75mm vs. 1.2mm), and the SID for acquisition is 182cm as well, so focal spot dimensions cannot explain the difference. The difference in MTF may be secondary to differences in generator X-ray spectrum or by unannounced changes in detector architecture. Further investigation is needed. Conclusion: The study shows that both TG150 and TQT tests are consistent. The numerical value of some metrics are dependent on ROI size.

60 APPLIED LIFE SCIENCES↗

Shepherding Metadata Through the Building Lifecycle

Many different digital representations of a building are produced over the course of its lifecycle. These representations contain the metadata required to support different stages of the building, from initial planning and design, to construction and commissioning, through operations, audits, retrofits and maintenance. However, because of differences in the semantics, structure and syntax of these representations, the metadata they contain is not interoperable. We present a novel method for leveraging these representations to create a unified, authoritative Brick metadata model for a building that can be continually maintained over the course of the building lifecycle. A simple synchronization protocol relays inferred Brick metadata from existing metadata sources such as gbXML, BuildingSync, Project Haystack and Modelica to a central integration server, which merges the metadata into a valid Brick model.

Fierro, Gabe↗

Commercial Building Energy Saver, API (CBES API) v2.0

The CBES API provides Application Programming Interface to a suite of functions to improve energy efficiency of buildings, including building energy benchmarking, preliminary retrofit analysis using a pre-simulation database DEEP, and detailed retrofit analysis using energy modeling with the EnergyPlus simulation engine. New capabilities in version 2.0 include renewable technologies (PV, storage), advanced HVAC systems, demand response measures, TDV (Time Dependent Valuation energy) metrics, as well as shading from adjacent buildings, trees or roof obstructions. The CBES API is used to power the LBNL CBES Web App. It can be used by third party developers and vendors.

Hong, Tianzhen↗

Wind turbine performance enhancement with minimal structural load penalty: A design philosophy

The performance benefits of using tip devices on wind turbines has been well-documented. However, previous studies show that adding blade tip devices such as winglets leads to a significant increase in blade root bending moment, potentially requiring structural reinforcement with cost and weight drawbacks. A new and unique design philosophy for retrofit blade tip devices for wind turbines is presented. By balancing generated aerodynamic and centrifugal loads, these devices offer an increase in power production without the need for structural reinforcement. Predicted performance and cost benefits of using retrofit blade tip devices on the National Renewable Energy Laboratory 5 MW reference wind turbine are shown. Finally, the addition of blade tip devices resulted in significant improvements in the coefficient of power (C p ) and annual energy production (AEP).

17 WIND ENERGY↗

Dual-Fuel Ammonia Equivalence Ratio Sweep Data

Ammonia (NH3) has garnered significant interest as an alternative fuel for meeting international emissions reduction mandates in sectors with high weight and distance requirements, such as shipping. Technical barriers and unanswered questions remain on the combustion strategies that can maximize ammonia utilization and minimize emissions. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep compared the use of early (E-pilot) and late (L-pilot) single diesel injections. The experiments were conducted at 1200 RPM and 12.8 ± 0.2 bar (75 % load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90 % ammonia energy substitution level. A diesel injection timing sweep was conducted for both the injection strategies at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2,eq and thermal efficiency benefits both E-pilot and L-pilot injection strategy cases compared with CDC at a λ of 1.4. The indicated nitrogen-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for L-pilot, but no apparent trend emerged for the E-pilot injection strategy at the tested boundary conditions. This dataset includes the raw experimental data and documentation of the experiment conditions and methods.

30 DIRECT ENERGY CONVERSION↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗

Modeling City Building Stock for Large-Scale Energy Efficiency Improvements using CityBES

Buildings in San Francisco consumed 52% of total primary energy. Improving building energy efficiency is one of the key strategies cities are adopting towards their energy and climate goals. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures for investment and to design effective incentive and rebate programs. This paper introduces methods to develop a standardized dataset of city building stock, and it demonstrates the use of a UBEM tool, City Building Energy Saver (CityBES), for an urban-scale energy retrofit analysis of building stock in the city of San Francisco. CityBES is an open web-based data and computing platform providing city-scale building energy modeling and performance visualization and benchmarking. CityBES utilizes an international standard CityGML to represent the three-dimensional building stock in cities. As an application example, 940 office and retail buildings in six districts of northeast San Francisco were modeled and analyzed with CityBES to evaluate energy savings for five selected measures. The analysis found that replacing existing lighting with LED and adding an air economizer to HVAC systems are cost-effective measures with combined savings per building between 17% to 31%. The CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or building energy models, which helps overcome barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting the undetected: Dealing with non-routine events using advanced M&V meter-based savings approaches

In a rapidly evolving energy industry, utilities are dealing with new challenges like integrating distributed energy resources and market saturation for advanced lighting retrofits. Demand-side management programs require new approaches to meet aggressive carbon reduction goals. Advanced measurement & verification (M&V) is an energy data analysis method using smart meter data in combination with analytics to quantify energy efficiency project savings. Advanced M&V shows great promise for supporting next generation commercial programs including retro commissioning, multi-measure retrofits, and behavior change programs. Advanced M&V captures real project impacts at the meter, but sometimes non-project events can also impact consumption (so-called “non-routine events” [NREs]). Accurately detecting and accounting for NREs is important for reducing uncertainty of savings estimates and helps manage investment risk for different stakeholders (e.g., utilities, building owners, ESCOs). Recent research has shown promise in establishing data-driven techniques to identify and adjust for NREs, but fundamental questions still remain, such as: how can you distinguish NREs from acceptable noise in energy consumption profiles? What is the frequency and magnitude of NREs? Can their detection and adjustment be automated and streamlined? This paper documents the state of the art in NRE quantification and analysis. The results of research to quantify the frequency, nature and direction of NREs, and methods and metrics for determining a trigger threshold for taking action on NREs are presented. The paper also documents the latest technical guidance on application of NRE detection and adjustment methods.

Fernandes, Samuel↗

Decarbonization of the Iron and Steel Sector: Challenges and Opportunities

The iron and steel industry is one of the largest contributors to industrial emissions in the United States (U.S.). As this industry represents an impactful opportunity for industrial decarbonization, this paper presents the techno-economics of retrofitting iron/steel plants in the U.S. with post-combustion carbon dioxide (CO2) capture technology. For a representative base plant, this analysis considers an integrated steel mill, including a blast furnace (BF) and basic oxygen furnace (BOF), and evaluates CO2 capture as applied to the three largest and highest concentration emission sources of these facilities. A levelized cost of CO2 captured (LCOC) of $80.3/tonne CO2 and $80.7/tonne CO2 was estimated for a retrofit site with 99 and 90 percent capture, respectively.

Henry, Samuel [NETL Site Support Contractor, Natio↗

Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

Thermal losses and gains from ductwork installed in unconditioned spaces—such as attics, crawl spaces, and garages—can contribute significantly to the overall heating and cooling loads of single-family residential buildings, with estimated duct losses ranging from 10%–45 %. The impact is particularly severe in hot climates where air conditioning dominates and extensive duct systems are typically located in hot attics. The duct system inefficiencies are greatest at peak demand conditions when the attic is hottest and run times are the highest. The thermal losses and gains at the three single-story houses in Florida monitored in this study accounted for 15%–35% of the annual pre-retrofit heating and cooling energy use and 6%–25% of the total pre-retrofit annual utility bill. Even though a number of existing methods can effectively move ducts into the conditioned space, they are not currently being widely implemented. Physically locating the ducts within the conditioned space is most often applicable only to new construction projects and requires planning during design. Attics can be insulated at the roof deck with closed-cell polyurethane foam (ccSPF) to reduce duct losses and infiltration rates, but this method has high up-front costs and the potential to increase loads on the building enclosure. In hot-dry climates, attic duct systems can be buried under loose-fill insulation at a significantly lower cost to reduce thermal loads. In hot-humid climates, however, condensation on the duct jacket can occur when the humidity in the attic is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verifying a Simplified Fuel Oil Flow Field Measurement Protocol

The Better Buildings program is a U.S. Department of Energy program funding energy efficiency retrofits in buildings nationwide. The program is in need of an inexpensive method for measuring fuel oil consumption that can be used in evaluating the impact that retrofits have in existing properties with oil heat. This project developed and verified a fuel oil flow field measurement protocol that is cost effective and can be performed with little training for use by the Better Buildings program as well as other programs and researchers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Building America Technology and Energy Savings Analysis of Two 2,721 ft 2 Homes in a Mixed Humid Climate

The ZEBRAlliance is an opportunity to accelerate progress toward DOE’s goal of maximizing cost-effective energy efficiency by investing in a highly leveraged, focused effort to test new high-efficiency components emerging from Oak Ridge National Laboratory’s (ORNL) Cooperative Research and Development Agreement (CRADA) partners and others. The Alliance integrated efficient components into the construction of four research houses that will be used as test markets to gauge the success of the components and houses. These four research houses are expected to be the first houses used to field-test several newly emerging products such as the ClimateMaster ground-source integrated heat pump. When these new components are proven, they will become available to serve regional and national homebuilding markets. Some of these products will impact existing housing retrofit markets as well as new construction. These four houses demonstrate different strategies for saving energy, but all are about 55-60% more efficient than traditional new construction (based on third party certified HERS evaluations). After the research period, the houses will be sold to interested home buyers. The outcome will contribute to efforts by TVA to defer 1,400 MW of new electricity generation and reduce growth in energy consumption by 4.3 million MWh per year by 2012, and in the longer term, to transform how homes are built and retrofitted for improved energy efficiency in the Tennessee Valley.

Jackson, Roderick K.↗

Moisture Durability of Vapor Permeable Insulating Sheathing [Fact Sheet]

In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor permeable insulation on retrofit walls with vapor permeable cavity insulation. Retrofit strategies are a key factor in reducing exterior building stock consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Town Energy Program (STEP) (Final Report revised)

University Park, Maryland (“UP”) is a small town of 2,540 residents, 919 homes, 2 churches, 1 school, 1 town hall, and 1 breakthrough community energy efficiency initiative: the Small Town Energy Program (“STEP”). STEP was developed with a mission to “create a model community energy transformation program that serves as a roadmap for other small towns across the U.S.” STEP first launched in January 2011 in UP and expanded in July 2012 to the neighboring communities of Hyattsville, Riverdale Park, and College Heights Estates, MD. STEP, which concluded in July 2013, was generously supported by a grant from the U.S. Department of Energy (DOE). The STEP model was designed for replication in other resource-constrained small towns similar to University Park - a sector largely neglected to date in federal and state energy efficiency programs. STEP provided a full suite of activities for replication, including: energy audits and retrofits for residential buildings, financial incentives, a community-based social marketing backbone and local community delivery partners. STEP also included the highly innovative use of an “Energy Coach” who worked one-on-one with clients throughout the program. Please see www.smalltownenergy.org for more information. In less than three years, STEP achieved the following results in University Park: • 30% of community households participated voluntarily in STEP; • 25% of homes received a Home Performance with ENERGY STAR assessment; • 16% of households made energy efficiency improvements to their home; • 64% of households proceeded with an upgrade after their assessment; • 9 Full Time Equivalent jobs were created or retained, and 39 contractors worked on STEP over the course of the project. Estimated Energy Savings - Program Totals kWh Electricity 204,407 Therms Natural Gas 24,800 Gallons of Oil 2,581 Total Estimated MMBTU Saved (Source Energy) 5,474 Total Estimated Annual Energy Cost Savings $\$61,343$ STEP clients who had a home energy upgrade invested on average $\$4,500$, resulting in a 13% reduction in annual energy use and utility bill savings of $325. Rebates and incentives covered 40%-50% of retrofit cost, resulting in an average simple payback of about 7 years. STEP has created a handbook in which are assembled all the key elements that went into the design and delivery of STEP. The target audiences for the handbook include interested citizens, elected officials and municipal staff who want to establish and run their own efficiency program within a small community or neighborhood, using elements, materials and lessons from STEP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Better Buildings Neighborhood Program: BetterBuildings Lowell (Final Report)

The City of Lowell set four goals at the beginning of the Better Buildings Neighborhood Program: 1. Improve the Downtown Historic Park District’s Carbon Footprint 2. Develop a sustainable and replicable model for energy efficiency in historic buildings 3. Create and retain jobs 4. Promote multi-stakeholder partnerships. The City of Lowell, MA was awarded $5 million in May 2010 to conduct energy efficiency retrofits within the downtown National Historical Park (NHP). The City’s target was to complete retrofits in 200,000 square feet of commercial space and create 280 jobs, while adhering to the strict historical preservation regulations that govern the NHP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Hampshire Better Buildings (Final Interim Report)

With $10 million in funding from the U.S. Department of Energy's (DOE) Better Buildings Neighborhood Program, the NH Better Buildings program was established as an initiative that initially empowered the three “Beacon Communities” of Berlin, Nashua and Plymouth to achieve transformative energy savings and reductions in fossil fuel use and greenhouse gases through deep energy retrofits and complementary sustainable energy solutions. The program also enabled those Communities to provide leadership to other communities around the state as “beacons” of energy efficiency. The goal of the program was to reduce energy use by a minimum of 15% through energy efficiency upgrades in residential and commercial buildings in the communities. The program expanded statewide in April 2012 by issuing a competitive solicitation for additional commercial projects non-profit, and municipal energy efficiency projects from any community in the state, and a partnership with the state’s utility-run, ratepayer-funded residential Home Performance with ENERGY STAR ® (HPwES) program. The NH Better Buildings program was administered by the New Hampshire Office of Energy and Planning (OEP) and managed by the NH Community Development Finance Authority (CDFA). The program started in July 2010 and the last projects funded with American Reinvestment and Recovery Act (ARRA) funds were completed in August 2013. The program will continue after the American Recovery and Reinvestment Act program period as a Revolving Loan Fund, enabling low-interest financing for deep energy retrofits into the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Safety, Operations, Security, and Safeguards (ISOSS) into the design of small modular reactors : a handbook.

The existing regulatory environment for nuclear reactors impacts both the facility design and the cost of operations once the facility is built. Delaying the consideration of regulatory requirements until late in the facility design - or worse, until after construction has begun - can result in costly retrofitting as well as increased operational costs to fulfill safety, security, safeguards, and emergency readiness requirements. Considering the scale and scope, as well as the latest design trends in the next generation of nuclear facilities, there is an opportunity to evaluate the regulatory requirements and optimize the design process for Small Modular Reactors (SMRs), as compared to current Light Water Reactors (LWRs). To this end, Sandia has embarked on an initiative to evaluate the interactions of regulations and operations as an approach to optimizing the design of SMR facilities, supporting operational efficiencies, as well as regulatory requirements. The early stages of this initiative consider two focus areas. The first focus area, reported by LaChance, et al. (2007), identifies the regulatory requirements established for the current fleet of LWR facilities regarding Safety, Security, Operations, Safeguards, and Emergency Planning, and evaluates the technical bases for these requirements. The second focus area, developed in this report, documents the foundations for an innovative approach that supports a design framework for SMR facilities that incorporates the regulatory environment, as well as the continued operation of the facility, into the early design stages, eliminating the need for costly retrofitting and additional operating personnel to fulfill regulatory requirements. The work considers a technique known as Integrated Safety, Operations, Security and Safeguards (ISOSS) (Darby, et al., 2007). In coordination with the best practices of industrial operations, the goal of this effort is to develop a design framework that outlines how ISOSS requirements can be incorporated into the pre-conceptual through early facility design stages, seeking a cost-effective design that meets both operational efficiencies and the regulatory environment. The larger scope of the project, i.e., in future stages, includes the identification of potentially conflicting requirements identified by the ISOSS framework, including an analysis of how regulatory requirements may be changed to account for the intrinsic features of SMRs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

2014 Building America House Simulation Protocols

As BA has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗