A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Widgets: Validated Systems Energy Savings and Utility Custom Incentive Program Systems Trends

Energy efficiency upgrades to buildings to date through avenues such as utility incentive programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Integrated building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings (Regnier et al. 2017) that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – energy savings assessments are inherently more complex and are not easily suited to the deemed measure model, and implementation of systems can be more disruptive. This paper presents the outcomes of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with ComEd, a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)), and Xcel Energy (CO, MN). Previous work described the potential for energy savings of these systems at the individual and market level, early test findings for the task-ambient lighting system, and described the work products to develop utility incentive programs (Regnier et al. 2016). This paper presents validated end use energy savings of all three systems showing energy savings of ~20% for automated shading combined with daylight dimming (does not include light fixture retrofit savings); 30-46% for task-ambient lighting systems combined with plug load occupancy controls, depending on technology package and office building size (no daylight dimming impacts); and ~94% in the south-façade daylit zone for workstation specific lighting systems with daylight dimming (including lighting retrofit and task tuning). Using a U.S. Department of Energy (DOE) reference building model (DOE 2018), this translates to whole building savings of 2-5% (large-medium commercial), 12-23% (large-small commercial), and 13-15% (medium-large commercial) for these systems respectively. Early findings from the utilities in deploying these systems through their incentive programs indicate that deployment methods such as direct install programs might be best suited for these integrated systems. Further, early findings from a scoping study across custom utility programs and federal retrofit programs indicate that component level retrofits are still prevalent even in these programs, pointing towards an opportunity for deeper energy savings deployment. High performance retrofit case studies demonstrate that deeper energy savings is possible through integrated approaches. Market stakeholder interviews indicate however that there is generally a low level of awareness of the potential for energy savings of these three integrated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solarize Fairbanks BRITE: Facilitating Efficient, Resilient Homes in Cold Climates

Solarize Fairbanks began an annual Solarize campaign in the Interior Alaska city in 2020, located in IECC climate zone 8, with a goal to increase the number of solar PV panels in the community. The campaign provides peer support, education, bulk purchase discounts, and simplified installation of solar PV technologies for homes, businesses, and nonprofits. In 2021, the campaign began offering energy audits to building and homeowners with a bulk discount; however, building owners were responsible for pursuing next steps on their own. In 2022, a diverse team of local, state, and federal partners formed a team to create a process to further facilitate energy efficiency improvements alongside solar PV technology. The resulting project, Solarize Fairbanks - Building Resilience for the Interior (BRITE) aims to build out an efficiency component over 3 years. If implemented, it will be the first efficiency add-on to a solarize campaign in Alaska. In year one, the team conducted energy audits of four nonprofits located in the cold climate of Interior Alaska and is providing technical assistance and fundraising for the nonprofits to pursue the recommended retrofits. These audits provided insights on the types of retrofits that could be expected to increase efficiency, comfort, and resiliency of buildings, including LED lighting retrofits, increased envelope insulation, improved building controls, and air source heat pump technology. A pre- and post-retrofit analysis will provide further insight on the energy savings and other benefits of the retrofits. It will also inform the offerings in the following years of the BRITE add-on to Solarize campaigns. In this presentation, program implementers will review the past campaigns of Solarize Fairbanks, summarize the energy efficiency and resiliency analyses of the nonprofit buildings, cover future plans for Solarize Fairbanks BRITE, and provide recommendations for other communities pursuing similar programs.

Alaska↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.

PNNL Lab Homes↗

The PNNL Lab Homes Experimental Plan, FY12-FY15

Retrofitting and renovating existing homes to save energy has become an increasingly important component of the Nation’s energy strategy. Recognizing the need to aggressively research and develop deep energy retrofit strategies for existing homes, the U.S. Department of Energy (DOE) is pursuing many innovative and impactful projects as part of its Building America (BA) program. One of these projects is providing partial support for two factory-built Lab Homes recently installed on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington, which allow for the validation, demonstration, and characterization of new, energy efficient and peak load shaving technologies. The experimental home is retrofit with an energy- or water-efficient or smart technology to demonstrate the performance of that technology, while the baseline home serves as the control for side-by-side comparison of performance in homes with and without the retrofit measure under identical occupancy rates and weather conditions. Together, they serve as a research platform for testing and comparing new ideas and approaches that are applicable to site-built and manufactured homes. As the Lab Homes steward, PNNL works with multiple clients and stakeholders to use the Lab Homes for experiments focused on reducing energy use, improving grid responsiveness, and shaving peak demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates

This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation. 1 - St. Louis Park house - St. Louis Park, MN 2 - Edina house - Edina, MN In this second study, the team wished to analyze the before and after air-tightness data from roof only ETMMS retrofits on 1.5-story homes in cold and very cold climates. To identify homes to analyze, we reached out to our national network of energy professionals, home performance contractors, and general contractors who had expressed interest in promoting roof-only External Thermal Moisture Management System (ETMMS) to clients. Five projects by three contractors were submitted for consideration as they were being done to mitigate severe ice dams for homeowners. Only two of the five projects followed a roof only ETMMS protocol. Data from the other three projects, however, were reviewed with the air-tightness data of 250 roof-only, interior-applied energy retrofits on 1.5-story homes provided by three NorthernSTAR industry partners. These data represent homes in the general market as well as homes that were part of the state of Minnesota weatherization program.

adhered applied membrane↗

Long-term carbon intensity reduction potential of K-12 school buildings in the United States

School buildings have a great potential for carbon emission reduction since their annual emission is about 72 million metric tons. Currently, more than 30% of school buildings were built before 1960 and are underperforming. To effectively reduce carbon emissions via school building retrofits, it is critical for policymakers to understand the carbon intensity reduction potential of retrofitting school buildings in different regions. Hence, this study develops a method to comprehensively assess the long-term carbon intensity reduction potential of aggregated commercial buildings on a county-by-county basis in the continental U.S. We apply this method to the K-12 school buildings including primary and secondary school buildings. Here, this paper predicts the carbon intensity reduction potential of K-12 school buildings with eight building retrofit measures from 2022 to 2050 in the continental U.S. The results reveal several interesting findings: (1) In the approximately 3,000 counties of the U.S. from 2022 to 2050, the carbon intensity reduction potential of retrofitting K-12 school buildings in each county ranges from 0.41 kg/m 2 to 40.00 kg/m 2 . (2) Even in the same climate zone, the trends of carbon intensity reduction potential from 2022 to 2050 are different depending on their electricity sources. For example, in a hot and humid climate zone, the carbon intensity reduction potential in Florida will decrease from 2044 to 2048. However, in Mississippi, the carbon intensity reduction potential from 2044 to 2046 will increase due to the termination of the nuclear energy usage. (3) Generally, reducing lighting power density leads to more carbon intensity reduction in most states, but it might not be applicable for states with high clean energy penetration, such as Washington.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plug Loads Conservation Measures

This software requires inputs of simple plug loads inventory information and calculates the energy and cost benefits of various retrofit opportunities. This tool includes energy conservation measures for: Vending Machine Misers, Delamp Vending Machine, Desktop to Laptop retrofit, CRT to LCD monitors retrofit, Computer Power Management Settings, and Energy Star Refrigerator retrofit. This tool calculates energy savings, demand reduction, cost savings, building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

Ian Metzger, JesseDean↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Technoeconomic Evaluation of MEA versus Mixed Amines for CO 2 Removal at Near-Commercial Scale at Duke Energy Gibson 3 Plant

Carbon emissions in the power sector remains an important goal for both US and Chinese decision makers and industrial leaders. In order to deeply reduce their greenhouse gas emissions, many utilities are considering carbon capture, utilization, and sequestration (CCUS). For the existing US and Chinese coal-burning fleets, post-combustion capture (PCC) is the only viable approach. While companies provide technology for PCC retrofits, typically solvent-based absorption systems involving amine solutions, the costs and performance of these systems remain largely untested in commercial settings. As such power generation companies have very few technical or economic data sets on which to base large capital decisions. In support of gaining this information, the world’s largest power company, Huaneng Power Group, has developed and deployed several PCC systems as retrofits to Chinese coal-fired power plants. Duke Energy Inc., North America’s largest power generator, is considering options for CCUS retrofits and has created a partnership with Huaneng to assess the viability of a retrofit project on one of its US plants. In support of this effort, and in partnership with Duke and Huaneng under the US-China Clean Energy Research Program (CERC), LLNL has evaluated the economics of a novel amine-solvent technology for removal of CO 2 from flue gas developed by Huaneng’s Clean Energy Research Institute (Huaneng CERI). This technology is being considered for implementation by Duke Energy at their Gibson-3 unit in Indiana.

01 COAL, LIGNITE, AND PEAT↗

Final Review of the Campbell Creek Demonstrations Showcased by Tennessee Valley Authority

The Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office funded and managed a showcase demonstration located in the suburbs of west Knox county, Tennessee. Work started March 2008 with the goal of documenting best practices for retrofitting existing homes and for building new high-efficiency homes. The Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) provided technical support. An analytical base was developed for helping homeowners, homebuyers, builders, practitioners and the TVA make informed economic decisions for the materials and incentives necessary to build a new high-efficiency home or retrofit an existing home. New approaches to more efficiently control active energy subsystems and information for selecting or upgrading to Energy Star appliances, changing all lights to 100% CFL s and upgrading windows to low-E gas filled glazing yields a 40% energy savings with neutral cash flow for the homeowner. Passive designs were reviewed and recommendations made for envelope construction that is durable and energy efficient. The Campbell Creek project complements the DOE Building Technologies Program strategic goal. Results of the project created technologies and design approaches that will yield affordable energy efficient homes. The 2010 DOE retrofit goals are to find retrofit packages that attain 30% whole house energy savings as documented by pre and post Home Energy rating scores (HERS). Campbell Creek met these goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency, Low Emission Refrigeration System

Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Engineering Design of a Post-Combustion CO 2 Capture (PCC) System for Duke Energy’s East Bend Station Using Membrane-Based Technology

The Electric Power Research Institute (EPRI) led a U.S. Department of Energy (DOE) funded study for a membrane-based post-combustion CO 2 capture (PCC) system retrofit to an existing U.S. coal power plant. EPRI teamed with technology suppliers, Membrane Technology and Research (MTR), engineering consultants Nexant, Trimeric Corporation and Bechtel Power Corporation, to develop a first-of-a-kind initial design and cost estimate for a PCC system at Duke Energy’s East Bend Station (EBS) in Kentucky. This project provides a comprehensive overview of the plant design proposed and develops estimated costs to within +/- 30% accuracy for retrofitting the existing EBS coal-fired power plant with the latest MTR’s second-generation Polaris™ membrane technology for CO 2 flue gas removal. The projects primary objective was to develop a design for Duke Energy that will require “minimally invasive surgery” on their existing 600-MWe coal-fired power plant, located on the Ohio River in Boone County, Kentucky. Unlike the current commercially available solvent-based capture systems that require a reliable source of steam to operate, the MTR membrane-based capture system is driven primarily by electric power. This direct, bolt-on approach to retrofitting carbon capture could potentially reduce the impact on the existing power plant, by minimal disruption of the existing facility’s infrastructure and operating procedures. This may also reduce the amount of retrofit downtime before the power plant can resume normal operations. A second objective was to reduce the cost of each ton of captured CO 2 while maintaining the existing 600 MW net output of the East Bend Station. With this aim in mind, various options to provide the necessary auxiliary power for the capture system were evaluated for the site. The full report describes in detail the overall design, layout and components of the entire EBS membrane capture system. The equipment and sizes, the capital cost estimate encompassing both engineering design and construction for the carbon capture process and balance of plant systems is presented. A detailed techno-economic analysis is also undertaken to examine the business case for capture.

01 COAL, LIGNITE, AND PEAT↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Analysis of Joist Masonry Moisture Content Monitoring

There are many existing buildings with load-bearing mass masonry walls, whose energy performance could be improved with the retrofit of insulation. However, adding insulation to the interior side of walls of such masonry buildings in cold (and wet) climates may cause performance and durability problems. Some concerns, such as condensation and freeze-thaw have known solutions. But wood members embedded in the masonry structure will be colder (and potentially wetter) after an interior insulation retrofit. Moisture content & relative humidity were monitored at joist ends in historic mass brick masonry walls retrofitted with interior insulation in a cold climate (Zone 5A); data were collected from 2012-2015. Eleven joist ends were monitored in all four orientations. One limitation of these results is that the renovation is still ongoing, with limited wintertime construction heating and no permanent occupancy to date. Measurements show that many joists ends remain at high moisture contents, especially at north- and east-facing orientations, with constant 100% RH conditions at the worst cases. These high moisture levels are not conducive for wood durability, but no evidence for actual structural damage has been observed. Insulated vs. non-insulated joist pockets do not show large differences. South facing joists have safe (10-15%) moisture contents. Given the uncertainty pointed out by research, definitive guidance on the vulnerability of embedded wood members is difficult to formulate. In high-risk situations, or when a very conservative approach is warranted, the embedded wood member condition can be eliminated entirely, supporting the joist ends outside of the masonry pocket.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. This paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic reliability assessment and case studies for predicted energy savings in residential buildings

This study aims to (1) investigate the key influential parameters (KIPs) in estimating the uncertainty of energy savings using a residential building energy simulation model and (2) perform uncertainty quantification for energy savings for several different scenarios. The proposed methodology was successfully applied to the calculation of uncertainties associated with residential energy retrofits using two test houses designed for pre- and post-retrofit cases. Uncertainties were determined using basic parameters that might be supplied to an energy model and then reevaluated based on an audit of the KIPs identified, resulting in substantially reduced uncertainty. Of four different scenarios, the most uncertain scenario estimated the annual energy savings from the retrofit would be between 18% and 51% at a 95% confidence level, and the least uncertain scenario estimated the annual savings would be between 26% and 40% at a 95% confidence level. The actual measured annual savings from the two test houses was 28%, which shows an agreement with the uncertainty analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗