Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLAR PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Community Solar

Community solar, also known as shared solar or solar gardens, is a distributed solar energy deployment model that allows customers to buy or lease part of a larger, offsite shared solar photovoltaic (PV) system and receive benefits of their participation.

achetypes of ownership↗

Optimisation of buildings' solar irradiation availability

In order to improve the sustainability of new and existing urban settlements it is desirable to maximise the utilisation of the solar energy incident on the building envelope, whether by passive or active means. To this end we have coupled a multi-objective optimisation algorithm with the backwards ray tracing program RADIANCE which itself uses a cumulative sky model for the computation of incident irradiation (W h/m{sup 2}) in a single simulation. The parameters to optimise are geometric (the height of buildings up to their facade and the height and orientation of roofs), but with the constraint of maintaining an overall built volume, and the objective function is heating season solar irradiation offset by envelope heat losses. This methodology has been applied to a range of urban typologies and produces readily interpretable results. The focus of this work is on the design of new urban forms but the method could equally be applied to examine the relative efficiency of existing urban settlements, by comparison of existing forms with the calculated optima derived from relevant specifications of the building envelope. (author)

14 SOLAR ENERGY↗

Cost and Reliability Improvement for CIGS-Based PV on Flexible Substrate: May 24, 2006 -- July 31, 2010

Global Solar Energy rapidly advances the cost and performance of commercial thin-film CIGS products using roll-to-roll processing on steel foil substrate in compact, low cost deposition equipment, with in-situ sensors for real-time intelligent process control. Substantial increases in power module efficiency, which now exceed 13%, are evident at GSE factories in two countries with a combinedcapacity greater than 75 MW. During 2009 the average efficiency of cell strings (3780 cm2) was increased from 7% to over 11%, with champion results exceeding 13% Continued testing of module reliability in rigid product has reaffirmed extended life expectancy for standard glass product, and has qualified additional lower-cost methods and materials. Expected lifetime for PV in flexible packagescontinues to increase as failure mechanisms are elucidated, and resolved by better methods and materials. Cost reduction has been achieved through better materials utilization, enhanced vendor and material qualification and selection. The largest cost gains have come as a result of higher cell conversion efficiency and yields, higher processing rates, greater automation and improved control inall process steps. These improvements are integral to this thin film PV partnership program, and all realized with the 'Gen2' manufacturing plants, processes and equipment.

14 SOLAR ENERGY↗

Indirect Solar Water Heating in Single-Family, Zero Energy Ready Homes

Solar water heating systems are not new, but they have not become prevalent in most of the U.S. Most of the country is cold enough that indirect solar thermal systems are required for freeze protection, and average installed cost of these systems is $9,000 to $10,000 for typical systems on single-family homes. These costs can vary significantly in different markets and with different contractors, and federal and regional incentives can reduce these up-front costs by 50% or more. In western Massachusetts, an affordable housing developer built a community of 20 homes with a goal of approaching zero net energy consumption. In addition to excellent thermal envelopes and PV systems, the developer installed a solar domestic water heating system (SDHW) on each home. The Consortium for Advanced Residential Buildings (CARB), a research consortium funded by the U.S. Department of Energy Building America program, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Indirect Solar Water Heating Systems in Single-Family Homes, Greenfield, Massachusetts

Solar water heating systems are not new, but they have not become prevalent in most of the U.S. Most of the country is cold enough that indirect solar thermal systems are required for freeze protection, and average installed cost of these systems is $9,000 to $10,000 for typical systems on single-family homes. These costs can vary significantly in different markets and with different contractors, and federal and regional incentives can reduce these up-front costs by 50% or more. In western Massachusetts, an affordable housing developer built a community of 20 homes with a goal of approaching zero net energy consumption. In addition to excellent thermal envelopes and PV systems, the developer installed a solar domestic water heating system (SDHW) on each home. The Consortium for Advanced Residential Buildings (CARB), a research consortium funded by the U.S. Department of Energy Building America program, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optoelectronic transport properties in amorphous/crystalline silicon solar cell heterojunctions measured by frequency-domain photocarrier radiometry: Multi-parameter measurement reliability and precision studies

A theoretical one-dimensional two-layer linear photocarrier radiometry (PCR) model including the presence of effective interface carrier traps was used to evaluate the transport parameters of p-type hydrogenated amorphous silicon (a-Si:H) and n-type crystalline silicon (c-Si) passivated by an intrinsic hydrogenated amorphous silicon (i-layer) nanolayer. Several crystalline Si heterojunction structures were examined to investigate the influence of the i-layer thickness and the doping concentration of the a-Si:H layer. The experimental data of a series of heterojunction structures with intrinsic thin layers were fitted to PCR theory to gain insight into the transport properties of these devices. The quantitative multi-parameter results were studied with regard to measurement reliability (uniqueness) and precision using two independent computational best-fit programs. The considerable influence on the transport properties of the entire structure of two key parameters that can limit the performance of amorphous thin film solar cells, namely, the doping concentration of the a-Si:H layer and the i-layer thickness was demonstrated. It was shown that PCR can be applied to the non-destructive characterization of a-Si:H/c-Si heterojunction solar cells yielding reliable measurements of the key parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soiling of building envelope surfaces and its effect on solar reflectance. Part I: Analysis of roofing product databases

The use of highly reflective “cool” roofing materials can decrease demand for air conditioning, mitigate the urban heat island effect, and potentially slow global warming. However, initially high roof solar reflectance can be degraded by natural soiling and weathering processes. We evaluated solar reflectance losses after three years of natural exposure reported in two separate databases: the Rated Products Directory of the US Cool Roof Rating Council (CRRC) and information reported by manufacturers to the US Environmental Protection Agency (EPA)’s ENERGY STAR® rating program. Many product ratings were culled because they were duplicative (within a database) or not measured. A second, site-resolved version of the CRRC dataset was created by transcribing from paper records the site-specific measurements of aged solar reflectance in Florida, Arizona and Ohio. Products with high initial solar reflectance tended to lose reflectance, while those with very low initial solar reflectance tended to become more reflective as they aged. Within the site-resolved CRRC database, absolute solar reflectance losses for samples of medium-to-high initial solar reflectance were 2 - 3 times greater in Florida (hot and humid) than in Arizona (hot and dry); losses in Ohio (temperate but polluted) were intermediate. Disaggregating results by product type, factory-applied coating, field-applied coating, metal, modified bitumen, shingle, singleply membrane and tile, revealed that absolute solar reflectance losses were largest for fieldapplied coating, modified bitumen and single-ply membrane products, and smallest for factoryapplied coating and metal products.The 2008 Title 24 provisional aged solar reflectance formula overpredicts the measured aged solar reflectance of 0% to 30% of each product type in the culled public CRRC database. The rate of overprediction was greatest for field-applied coating and single-ply membrane products and least for factory-applied coating, shingle, and metal products. New product-specific formulas can be used to estimate provisional aged solar reflectance from initial solar reflectance pending measurement of aged solar reflectance. The appropriate value of soiling resistance varies by product type and is selected to attain some desired overprediction rate for the formula. The correlations for shingle products presented in this paper should not be used to predict aged solar reflectance or estimate provisional aged solar reflectance because the data set is too small and too limited in range of initial solar reflectance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verified lifting of stencil computations

This paper demonstrates a novel combination of program synthesis and verification to lift stencil computations from low-level Fortran code to a high-level summary expressed using a predicate language. The technique is sound and mostly automated, and leverages counter-example guided inductive synthesis (CEGIS) to find provably correct translations. Lifting existing code to a high-performance description language has a number of benefits, including maintainability and performance portability. For example, our experiments show that the lifted summaries can enable domain specific compilers to do a better job of parallelization as compared to an off-the-shelf compiler working on the original code, and can even support fully automatic migration to hardware accelerators such as GPUs. We have implemented verified lifting in a system called STNG and have evaluated it using microbenchmarks, mini-apps, and real-world applications. Here, we demonstrate the benefits of verified lifting by first automatically summarizing Fortran source code into a high-level predicate language, and subsequently translating the lifted summaries into Halide, with the translated code achieving median performance speedups of 4.1X and up to 24X for non-trivial stencils as compared to the original implementation.

97 MATHEMATICS AND COMPUTING↗

DEVELOPMENT OF A SOFTWARE DESIGN TOOL FOR HYBRID SOLAR-GEOTHERMAL HEAT PUMP SYSTEMS IN HEATING- AND COOLING-DOMINATED BUILDINGS

This project provides an easy-to-use, menu-driven, software tool for designing hybrid solar-geothermal heat pump systems (GHP) for both heating- and cooling-dominated buildings. No such design tool currently exists. In heating-dominated buildings, the design approach takes advantage of glazed solar collectors to effectively balance the annual thermal loads on the ground with renewable solar energy. In cooling-dominated climates, the design approach takes advantage of relatively low-cost, unglazed solar collectors as the heat rejecting component. The primary benefit of hybrid GHPs is the reduced initial cost of the ground heat exchanger (GHX). Furthermore, solar thermal collectors can be used to balance the ground loads over the annual cycle, thus making the GHX fully sustainable; in heating-dominated buildings, the hybrid energy source (i.e., solar) is renewable, in contrast to a typical fossil fuel boiler or electric resistance as the hybrid component; in cooling-dominated buildings, use of unglazed solar collectors as a heat rejecter allows for passive heat rejection, in contrast to a cooling tower that consumes a significant amount of energy to operate, and hybrid GHPs can expand the market by allowing reduced GHX footprint in both heating- and cooling-dominated climates. The design tool allows for the straight-forward design of innovative GHP systems that currently pose a significant design challenge. The project lays the foundations for proper and reliable design of hybrid GHP systems, overcoming a series of difficult and cumbersome steps without the use of a system simulation approach, and without an automated optimization scheme. As new technologies and design concepts emerge, sophisticated design tools and methodologies must accompany them and be made usable for practitioners. Lack of reliable design tools results in reluctance of practitioners to implement more complex systems. A menu-driven software tool for the design of hybrid solar GHP systems is provided that is based on mathematically robust, validated models. An automated optimization tool is used to balance ground loads and incorporated into the simulation engine. With knowledge of the building loads, thermal properties of the ground, the borehole heat exchanger configuration, the heat pump peak hourly and seasonal COP for heating and cooling, the critical heat pump design entering fluid temperature, and the thermal performance of a solar collector, the total GHX length can be calculated along with the area of a supplemental solar collector array and the corresponding reduced GHX length. An economic analysis module allows for the calculation of the lowest capital cost combination of solar collector area and GHX length. ACKNOWLEDGMENTS This project was funded by the United States Department of Energy DOE-DE-FOA-0000116, Recovery Act Geothermal Technologies Program: Ground Source Heat Pumps. The lead contractor, The University of Hartford, was supported by The University of Dayton, and the Oak Ridge National Laboratories. All funding and support for this project as well as contributions of graduate and undergraduate students from the contributing institutions are gratefully acknowledged.

14 SOLAR ENERGY↗

Intersections of Disadvantaged Communities and Renewable Energy Potential: Analyses to Inform Equitable Investment Prioritization

Renewable energy development can bolster local economies through job creation, local tax revenues, and reduced energy costs; however, communities most in need of economic development and employment opportunities often see lower levels of renewable energy deployment. We sought to identify areas where indicators of disadvantaged communities intersect with high generation potential from cost- effective renewable energy opportunities. This presentation highlights the geospatial intersection of the technical potential and levelized cost of energy for three renewable technologies (residential solar, utility solar, and land-based wind) and three sociodemographic metrics (energy burden, unemployment, and employment in mining, quarrying, and oil and gas extraction). This research and the associated county-level data set are intended to inform national- and state-level energy-related assistance programs, economic development efforts, and infrastructure programs seeking to prioritize investments in disadvantaged communities.

disadvantaged communities↗

Quantifying the sensitivity of ephemeral streams to land disturbance activities in arid ecosystems at the watershed scale

Large areas of public lands administered by the Bureau of Land Management and located in arid regions of the southwestern United States are being considered for the development of utility-scale solar energy facilities. Land-disturbing activities in these desert, alluvium-filled valleys have the potential to adversely affect the hydrologic and ecologic functions of ephemeral streams. Regulation and management of ephemeral streams typically falls under a spectrum of federal, state, and local programs, but scientifically based guidelines for protecting ephemeral streams with respect to land-development activities are largely nonexistent. This study developed an assessment approach for quantifying the sensitivity to land disturbance of ephemeral stream reaches located in proposed solar energy zones (SEZs). The ephemeral stream assessment approach used publicly-available geospatial data on hydrology, topography, surficial geology, and soil characteristics, as well as highresolution aerial imagery. These datasets were used to inform a professional judgment-based score index of potential land disturbance impacts on selected critical functions of ephemeral streams, including flow and sediment conveyance, ecological habitat value, and groundwater recharge. The total sensitivity scores (sum of scores for the critical stream functions of flow and sediment conveyance, ecological habitats, and groundwater recharge) were used to identify highly sensitive stream reaches to inform decisions on developable areas in SEZs. Total sensitivity scores typically reflected the scores of the individual stream functions; some exceptions pertain to groundwater recharge and ecological habitats. The primary limitations of this assessment approach were the lack of high-resolution identification of ephemeral stream channels in the existing National Hydrography Dataset, and the lack of mechanistic processes describing potential impacts on ephemeral stream functions at the watershed scale.The primary strength of this assessment approach is that it allows watershed-scale planning for low-impact development in arid ecosystems; the qualitative scoring of potential impacts can also be adjusted to accommodate new geospatial data, and to allow for expert and stakeholder input into decisions regarding the identification and potential avoidance of highly sensitive stream reaches.

Arid ecosystems↗

REopt Lite Overview & Training Exercise

This training exercise provides users with an introduction to and hands-on, interactive exploration of REopt Lite's capabilities. REopt Lite is a free, publicly available techno-economic optimization web tool for distributed energy systems, developed at the National Renewable Energy Laboratory (NREL). REopt Lite helps organizations evaluate the economic viability of grid-connected solar photovoltaics (PV), wind turbines, and battery storage; identify system sizes and battery dispatch strategies to minimize energy costs; and estimate how long a system can sustain critical load during a grid outage. The model is formulated as a mixed-integer linear program based in an underlying application programming interface (API) that is also free and publicly available. This training activity is structured as a group exercise. Participants split into eight groups and each group is assigned a different hypothetical site to model and assess the opportunity for solar PV + battery storage. Groups work together to develop results for their site and then re-convene to compare and discuss results, inputs/drivers of the analysis, and other factors impacting the decision-making process for behind-the-meter solar PV and battery storage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Privacy-Preserving Aggregation of Controllable Loads to Compensate Fluctuations in Solar Power

Cybersecurity and privacy are of the utmost importance for safe, reliable operation of the electric grid. It is well known that the increased connectivity/interoperability between all stakeholders (e.g., utilities, suppliers, and consumers) will enable personal information collection. Significant advanced metering infrastructure (AMI) deployment and demand response (DR) programs across the country, while enable enhanced automation, also generate energy data on individual consumers that can potentially be used for exploiting privacy. Inspired by existing works which consider DR, battery-based perturbation, and differential privacy noise adding, we novelly consider the aggregator (cluster) level privacy issue in the DR framework of solar photovoltaic (PV) generation following. Different from most of the existing works which mainly rely on the charging/discharging scheduling of rechargeable batteries, we utilize controllable building loads to serve as virtual storage devices to absorb a large portion of the PV genertaion while delicately keeping desired noisy terms to satisfy the differential privacy for the raw load profiles at the aggregator level. This not only ensures differential privacy, but also improves the DR efficiency in load following since part of the noisy signal in solar PV generation has been filtered out. In particular, a mixed integer quadratic optimization problem is formulated to optimally dispatch a population of on/off controllable loads to achieve this privacy-preserving DR service.

Dong, Jin↗

Modeling the direct sun component in buildings using matrix algebraic approaches: Methods and validation

Simulation tools that enable annual energy performance analysis of optically-complex fenestration systems have been widely adopted by the building industry for use in building design, code development, and the development of rating and certification programs for commercially-available shading and daylighting products. The tools rely on a three-phase matrix operation to compute solar heat gains, using as input low-resolution bidirectional scattering distribution function (BSDF) data (10–15° angular resolution; BSDF data define the angle-dependent behavior of light-scattering materials and systems). Measurement standards and product libraries for BSDF data are undergoing development to support solar heat gain calculations. Simulation of other metrics such as discomfort glare, annual solar exposure, and potentially thermal discomfort, however, require algorithms and BSDF input data that more accurately model the spatial distribution of transmitted and reflected irradiance or illuminance from the sun (0.5° resolution). This study describes such algorithms and input data, then validates the tools (i.e., an interpolation tool for measured BSDF data and the five-phase method) through comparisons with ray-tracing simulations and field monitored data from a full-scale testbed. Simulations of daylight-redirecting films, a micro-louvered screen, and venetian blinds using variable resolution, tensor tree BSDF input data derived from interpolated scanning goniophotometer measurements were shown to agree with field monitored data to within 20% for greater than 75% of the measurement period for illuminance-based performance parameters. The three-phase method delivered significantly less accurate results. We discuss the ramifications of these findings on industry and provide recommendations to increase end user awareness of the current limitations of existing software tools and BSDF product libraries.

14 SOLAR ENERGY↗

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

Advanced Ultrasupercritical (AUSC) Materials Thick-Walled Cycling Header Development for ComTest-AUSC (Final Report)

Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE) recently completed “Advanced Ultrasupercritical (AUSC) Materials Thick-Walled Cycling Header Development for ComTest-AUSC” under Award No. DE-FE0026183 for the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). This project developed a design for testing of a high temperature nickel-based superalloy thick-walled header to simulate cycling and flexible plant operation in new and existing plants. The objective was to simulate the expected thermal stresses of a new AUSC plant or a retrofit header in an existing plant to improve flexible dynamic operation while maintaining component integrity and overall power plant reliability. The high performance superalloy materials that enable higher operating temperatures and pressures can support future transformational power technologies including new AUSC plants at 4250-5000 psi, 730°C/760°C or will serve as a replacement component in a repowered or retrofit USC coal powered cycling plant at 3600 psi, 600°C. These alloys can also enable supercritical CO2 cycles, nuclear power, solar power and more efficient natural gas combined cycle units as targeted by the U.S. DOE/NETL Cross-Cutting Research Technology Program Plan. Recently developed advanced nickel alloys such as Inconel 740H (740H) and Haynes 282 (H282) have been successfully tested on a pilot scale for fireside corrosion using steam loop tubing at AUSC temperatures of 760°C in actual operating coal fired boiler. These high strength materials have been demonstrated their adequacy for use in other high temperature boiler components such as superheater tubes. Thick-walled superheater outlet headers which operate at high temperatures and pressure under severe cycling condition are considered as one of the most critical component in the AUSC coal fired boiler. Over the design life of a plant, these headers are exposed to the most severe fatigue and creep damage accumulation and need to be properly designed for the expected cycling in an AUSC plant with flexible operation. These materials need to demonstrate adequate design life of 20 to 30 years for creep and fatigue conditions. The following tasks were performed: 1. A conceptual design was developed of a thick-walled component representative of typical headers with several tube connections and proper flow rates (~100,000 lbs/hr) suitable for Phase II test at 760°C operation. This was based on a process analysis of expected full scale new and component retrofit designs for AUSC; 2. A multi-physics flow and heat transfer computational fluid dynamics (CFD) analysis of the component for proper layout of the header configuration, number and geometry (size) of tubes required for bypass flow, flow rates through the tubing, and sectional pressure drops was performed. Steam to header metal heat transfer film coefficients in the header section and the tubes during the two stages (half load and full load) of the cycling operation were evaluated and used in the stress analysis; 3. Detailed analytical evaluation of the thick-walled pipe and tube connections for mechanical integrity under cycling conditions was performed. This included transient thermal stress analysis and fatigue usage estimation including the tube-to-pipe weld geometries and weld materials; 4. A layout and design of the thick-walled test component was developed and instrumentation required for a test was identified; 5. Continuum Damage Mechanics (CDM) creep prediction models were extended to 740H and H282 and validated with public data on 740H and H282 for use in creep analysis. In addition, detailed creep analyses were performed separately for the design life of the conceptual AUSC superheater outlet header using these General Electric (GE) creep constitutive models. GE was the prime contractor for the project, which was directed by Principal Investigator Robert Schrecengost and Lead Scientist Dr. B. Reddy Ganta. Other collaborative participants in this project included GE Global Research, GE Boiler Engineering, and a Technical Consultant from EPRI.

01 COAL, LIGNITE, AND PEAT↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗