Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Terahertz-Driven Local Dipolar Correlation in a Quantum Paraelectric

Light-induced ferroelectricity in quantum paraelectrics is a new avenue of achieving dynamic stabilization of hidden orders in quantum materials. In this Letter, we explore the possibility of driving a transient ferroelectric phase in the quantum paraelectric KTaO 3 via intense terahertz excitation of the soft mode. We observe a long-lived relaxation in the terahertz-driven second harmonic generation (SHG) signal that lasts up to 20 ps at 10 K, which may be attributed to light-induced ferroelectricity. Through analyzing the terahertz-induced coherent soft-mode oscillation and finding its hardening with fluence well described by a single-well potential, we demonstrate that intense terahertz pulses up to 500 kV=cm cannot drive a global ferroelectric phase in KTaO 3 . Instead, we find the unusual long-lived relaxation of the SHG signal comes from a terahertz-driven moderate dipolar correlation between the defect-induced local polar structures. We discuss the impact of our findings on current investigations of the terahertz-induced ferroelectric phase in quantum paraelectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation of infrared spectra and phase transitions in annealed proton-exchanged MgO doped LiNbO{sub 3}

Infrared spectra of OH{sup −} groups in annealed proton-exchanged (APE) 5 mol. % MgO-doped LiNbO{sub 3} (MgO:LiNbO{sub 3}) crystals were studied using the Fourier transform infrared spectroscopy technique. Samples were prepared by benzoic acid proton-exchange followed with thermal annealing in oxygen. Evolutions of absorption peaks in APE MgO:LiNbO{sub 3} crystals were recorded and analyzed. Comparing with none-doped APE LiNbO{sub 3} crystals, a different phase transition behavior was found during thermal annealing. A periodically poled MgO:LiNbO{sub 3} slab waveguide was prepared using identical procedures, and the second harmonic generation (SHG) signals were measured. Comparing the obtained SHG results with the infrared spectra, relationships between the phase transitions and the recovery of second-order nonlinear coefficients during thermal annealing were investigated. Finally, a method for optimizing the performance of MgO:LiNbO{sub 3} waveguides was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lensing and the Warm-hot Intergalactic Medium

The correlation of weak lensing and Cosmic Microwave Anisotropy (CMB) data traces the pressure distribution of the hot, ionized gas and the underlying matter density field. The measured correlation is dominated by baryons residing in halos. Detecting the contribution from unbound gas by measuring the residual cross-correlation after masking all known halos requires a theoretical understanding of this correlation and its dependence with model parameters. Our model assumes that the gas in filaments is well described by a log-normal probability distribution function, with temperatures 10{sup 5–7} K and overdensities ξ ≤ 100. The lensing-Comptonization cross-correlation is dominated by gas with overdensities in the range ξ ≈ [3–33]; the signal is generated at redshifts z ≤ 1. If only 10% of the measured cross-correlation is due to unbound gas, then the most recent measurements set an upper limit of T-bar {sub e}≲10{sup 6} K on the mean temperature of the intergalactic Medium. The amplitude is proportional to the baryon fraction stored in filaments. The lensing-Comptonization power spectrum peaks at a different scale than the gas in halos, making it possible to distinguish both contributions. To trace the distribution of the low-density and low-temperature plasma on cosmological scales, the effect of halos will have to be subtracted from the data, requiring observations with larger signal-to-noise ratios than are currently available.

79 ASTRONOMY AND ASTROPHYSICS↗

A Fiber-Optic Borehole Seismic Vector Sensor System for Geothermal Site Characterization and Monitoring

Seismic techniques are the dominant geophysical techniques for the characterization of subsurface structures and stratigraphy. The seismic techniques also dominate the monitoring and mapping of reservoir injection and production processes. Borehole seismology, of all the seismic techniques, despite its current shortcomings, has been shown to provide the highest resolution characterization and most precise monitoring results because it generates higher signal to noise ratio and higher frequency data than surface seismic techniques. The operational environments for borehole seismic instruments are however much more demanding than for surface seismic instruments making both the instruments and the installation much more expensive. The current state-of-the-art borehole seismic instruments have not been robust enough for long term monitoring compounding the problems with expensive instruments and installations. Furthermore, they have also not been able to record the large bandwidth data available in boreholes or having the sensitivity allowing them to record small high frequency micro seismic events with high vector fidelity. To reliably achieve high resolution characterization and long term monitoring of Enhanced Geothermal Systems (EGS) sites a new generation of borehole seismic instruments must therefore be developed and deployed. To address the critical site characterization and monitoring needs for EGS programs, US Department of Energy (DOE) funded Paulsson, Inc. in 2010 to develop a fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying up to one thousand 3C sensor pods suitable for deployment into ultra-high temperature and high pressure boreholes. Tests of the fiber optic seismic vector sensors developed on the DOE funding have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown that the system can record events at magnitudes much smaller than M-2.6 at frequencies up to 2,000 Hz. The sensors have also proved to be about 100 times more sensitive than the regular coil geophones that are used in borehole seismic systems today. The fiber optic seismic sensors have furthermore been qualified to operate at temperatures over 300°C (572°F). Simultaneously with the fiber optic based seismic 3C vector sensors we are using the lead-in fiber to acquire Distributed Acoustic Sensor (DAS) data from the surface to the bottom of the vector array. While the DAS data is of much lower quality than the vector sensor data it provides a 1 m spatial sampling of the downgoing wavefield which will be used to build the high resolution velocity model which is an essential component in high resolution imaging and monitoring.

15 GEOTHERMAL ENERGY↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Quantum primordial standard clocks

In this paper, we point out and study a generic type of signals existing in the primordial universe models, which can be used to model-independently distinguish the inflation scenario from alternatives. These signals are generated by massive fields that function as standard clocks. The role of massive fields as standard clocks has been realized in previous works. Although the existence of such massive fields is generic, the previous realizations require sharp features to classically excite the oscillations of the massive clock fields. Here, we point out that the quantum fluctuations of massive fields can actually serve the same purpose as the standard clocks. We show that they are also able to directly record the defining property of the scenario type, namely, the scale factor of the primordial universe as a function of time a(t), but through shape-dependent oscillatory features in non-Gaussianities. Since quantum fluctuating massive fields exist in any realistic primordial universe models, these quantum primordial standard clock signals are present in any inflation models, and should exist quite generally in alternative-to-inflation scenarios as well. However, the amplitude of such signals is very model-dependent.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

Can Vertical Profiles of Tropospheric Methane on Titan Be Derived from Radio-Occultation Soundings?

The intensity of the received signal at Earth in the radio occultations of Titan is attenuated both by refractive defocusing and pressure-induced absorption from N2-N2 and CH4-N2 pairs. Because the absorption strength is different for the two sets of pairs, matching the retrieved absorptivity profile can in principle yield the vertical variation in gaseous methane in the troposphere. There are two factors that make this difficult. The first is the propagation of noise in the phase and amplitude of the received signal in the absorption retrieval. The phase data is first inverted to retrieve vertical profiles of refractivity, from which the refractive defocusing is calculated. This is then subtracted from the observed. intensity attenuation of the received signal to generate a profile of atmospheric absorption. The second problem is the uncertainty in the pressure-induced absorption coefficients. Laboratory data at radio wavelengths is only available near room temperature (see, e.g., [1] for N2-N2), and the extrapolation to the low temperatures in Titan's troposphere is not well established. Ab initio calculations by Borysow et al. [2, 3] provide absorption coefficients at low temperatures and long wavelengths, but their accuracy has come into question. We present examples from Cassini radio occultations of Titan to illustrate the difficulties. For methane mole fractions in the lower troposphere comparable to that inferred from the Huygens probe (approximately 0.05), it will be difficult to separate the contributions of N2-N2 collisions from those of N2-CH4, collisions to the retrieved absorption. However, higher concentrations of CH4 and/or a higher signal-to-noise ratio from a future uplink experiment could result in a successful separation of the two components. However, key to this are highly accurate estimates of the absorption from a combination of laboratory measurements at love temperatures and long wavelengths, and possibly improved theoretical calculations.

Flasar, F. Michael↗

Possible Explanation of the Geograv Detector Signal during the Explosion of SN 1987A in Modified Gravity Models

A change in the law of attraction in some regimes is predicted in the modified gravity models being actively developed at present. The set of up-to-date observational data leaves a wide range of admissible parameters for the theory. In this paper, we consider the possibility that the signal recorded by the Geograv resonant gravitational-wave detector in 1987 during the explosion of SN 1987A was produced by an abrupt change in the metric during the passage of a powerful neutrino flux through the detector. Such an impact on the detector is possible, in particular, in extended scalar–tensor theories in which the local matter density gradient affects the gravitational force. The first short neutrino pulse emitted at the initial stage of stellar core collapse before the onset of neutrino opacity could exert a major influence on the detector, because it could produce the detector response at the first resonance frequency. In contrast, the influence of the subsequent broad pulse (with a duration of several seconds) in the resonant detector is exponentially suppressed, despite the fact that the second pulse carries an order-of-magnitude more neutrino energy, and it could generate a signal in the LSD neutrino detector. This explains the time delay of 1.4 s between the Geograv and LSD signals. The consequences of this effect of modified gravity for future LIGO/Virgo observations are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Simulation of Infrasound Resonance in Underground Tunnel Structures

Remote observation of infrasound resonant signals emanating from underground tunnel structures could potentially allow the remote quantification of the geometry of the underground structures in which the signals were generated. However, the sensitivity of these observations to tunnel geometry and changes in that geometry are unknown. In this report we outline a numerical simulation study with the following three objectives: 1. Can we model infrasound resonance using numerical simulations? 2. What is the sensitivity of the modeled observations to changes in tunnel geometry or boundary conditions? And 3. Can we accurately model resonant observations of explosions occurring in Redmond Salt Mine in Central Utah. In this report we outline affirmative answers to the first two objectives, but we were unable to accurately model the Redmond Explosions due to numerical instability in the model of the complex structure of the mine. Recommendations for future work emphasize the need to acquire additional datasets and to explore a more data-based approach in which changes in data signatures are detected as a first step towards developing a method which inverts resonant infrasound signals for tunnel geometry.

47 OTHER INSTRUMENTATION↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital acoustic sensor performance across the infrasound range in non-isolated conditions

The next generation of acoustic sensors is emerging to supplement legacy sensors traditionally used in regional and global networks. These devices operate under similar principles as traditional sensors, without the need of a separate external digitizer. The calibration of these sensors against their predecessors is crucial to the modernization of conventional technologies. This work describes the characterization of the next-generation MB3 digital microbarometer and the iPrecision smartphone microphone in a non-isolated calibration room across the infrasound (i.e., 0.01–20 Hz) range. The intent is to evaluate nominal instrument performance before deployment. A portable rotary subwoofer is used as a controllable infrasound source to generate single-tone sinusoidal and broadband noise pressure waves in a room configured for calibration purposes. For each device, comparison measurements are made, from which the digital sensitivity and the parametric response is developed. The results provide insight into the performance of the sensors in non-isolated environments. By overlapping the responses of the test sensors, digital sensor performance across the infrasound range can be benchmarked. These responses may serve as a double-reference scheme in future pressure measurements and digital calibrations of acoustic sensors.

47 OTHER INSTRUMENTATION↗

Stellar Mass Black Hole Formation and Multimessenger Signals from Three-dimensional Rotating Core-collapse Supernova Simulations

We present self-consistent 3D core-collapse supernova simulations of a 40 ${M}_{\odot }$ progenitor model using the isotropic diffusion source approximation for neutrino transport and an effective general relativistic potential up to `0.9 s postbounce. We consider three different rotational speeds with initial angular velocities of ${{\rm{\Omega }}}_{0}=0$, 0.5, and 1 rad s -1 and investigate the impact of rotation on shock dynamics, black hole (BH) formation, and gravitational wave (GW) signals. The rapidly rotating model undergoes an early explosion at ~250 ms postbounce and shows signs of the low $T/| W| $ instability. We do not find BH formation in this model within ~460 ms postbounce. In contrast, we find BH formation at 776 ms postbounce and 936 ms postbounce for the nonrotating and slowly rotating models, respectively. The slowly rotating model explodes at ~650 ms postbounce, and the subsequent fallback accretion onto the proto–neutron star (PNS) results in BH formation. In addition, the standing accretion shock instability induces rotation of the PNS in the model that started with a nonrotating progenitor. Assuming conservation of specific angular momentum during BH formation, this corresponds to a BH spin parameter of a = J/M = 0.046. However, if no explosion sets in, all the angular momentum will eventually be accreted by the BH, resulting in a nonspinning BH. The successful explosion of the slowly rotating model drastically slows down the accretion onto the PNS, allowing continued cooling and contraction that results in an extremely high GW frequency (f ~ 3000 Hz) at BH formation, while the nonrotating model generates GW signals similar to our corresponding 2D simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma diagnostic method using intermodulation frequencies in a Langmuir probe

A plasma diagnostic method using intermodulation frequencies is developed. When dual-frequency (ω{sub 1},ω{sub 2}) voltage signals are applied to a probe, the intermodulation frequencies (ω{sub 2}±ω{sub 1}, ω{sub 2}±2ω{sub 1}) between the signals are generated due to the nonlinearity of the sheath. From the analysis of the intermodulation frequencies, the plasma parameters, such as the electron temperature and the plasma density, can be obtained. The measured plasma parameters from this method are compared to the results from the measured electron energy distribution function, and they are in good agreement. Because the intermodulation currents originated from the plasma not from the stray component of the measurement system, an accurate measurement of the plasma parameters is achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preface: Special Topic on Multidimensional Spectroscopy

Multidimensional signals are generated by subjecting molecules to sequences of short optical pulses and recording correlation plots related to the various controlled delay periods. These techniques which span all the way from the THz to the x-ray regimes provide qualitatively new structural and dynamical molecular information not available from conventional one-dimensional techniques. This issue surveys the recent experimental and theoretical progresses in this rapidly developing 20 year old field which illustrates the novel insights provided by multidimensional techniques into electronic and nuclear motions. It should serve as a valuable source for experts in the field and help introduce newcomers to this exciting and challenging branch of nonlinear spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modulation calorimetry in diamond anvil cells. II. Joule-heating design and prototypes

Here, Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz–10 MHz), opening up the possibility of new methods to detect and characterize transformations at high-pressure such as the glass transitions, melting, magnetic orderings, and the onset of superconductivity. Here, we test the possibility outlined in Part I, using prototypes and detailed numerical models. First, a coupled electrical-thermal numerical model shows that specific heat of metals inside diamond cells can be measured directly using ~1 MHz frequency, with <10% accuracy. Second, we test physical models of high-pressure experiments, i.e., diamond-cell mock-ups. Metal foils of 2–6 μm-thickness are clamped between glass insulation inside diamond anvil cells. Fitting data from 10 Hz to ~30 kHz, we infer the specific heat capacities of Fe, Pt, and Ni with ±20%–30% accuracy. The electrical test equipment generates -80 dBc spurious harmonics, which overwhelm the thermally induced harmonics at higher frequencies, disallowing the high precision expected from numerical models. An alternative Joule-heating calorimetry experiment, on the other hand, does allow absolute measurements with < 10% accuracy, despite the -80 dBc spurious harmonics: the measurement of thermal effusivity, $ \sqrt{ρck}$ (ρ, c , and k being density, specific heat, and thermal conductivity), of the insulation surrounding a thin-film heater. Using a ~50 nm-thick Pt heater surrounded by glass and 10 Hz–300 kHz frequency, we measure thermal effusivity with ±6% accuracy inside the sample chamber of a diamond anvil cell.

42 ENGINEERING↗