Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Evidence for B+ -> K*0bar K*+

We present measurements of the branching fraction and fraction of longitudinal polarization for the decay B{sup +} {yields} {bar K}*{sup 0} K*{sup +} with a sample of 467 {+-} 5 million B{bar B} pairs collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory. We obtain the branching fraction {Beta}(B{sup +} {yields} {bar K}*{sup 0} K*{sup +}) = (1.2 {+-} 0.5 {+-} 0.1) x 10{sup ?6} with a significance of 3.7 standard deviations including systematic uncertainties. We measure the fraction of longitudinal polarization f{sub L} = 0.75{sub -0.26}{sup +0.16} {+-} 0.03. The first error quoted is statistical and the second is systematic.

43 PARTICLE ACCELERATORS↗

LoCuSS: THE MASS DENSITY PROFILE OF MASSIVE GALAXY CLUSTERS AT z = 0.2 {sup ,}

We present a stacked weak-lensing analysis of an approximately mass-selected sample of 50 galaxy clusters at 0.15 < z < 0.3, based on observations with Suprime-Cam on the Subaru Telescope. We develop a new method for selecting lensed background galaxies from which we estimate that our sample of red background galaxies suffers just 1% contamination. We detect the stacked tangential shear signal from the full sample of 50 clusters, based on this red sample of background galaxies, at a total signal-to-noise ratio of 32.7. The Navarro-Frenk-White model is an excellent fit to the data, yielding sub-10% statistical precision on mass and concentration: M{sub vir}=7.19{sup +0.53}{sub -0.50} Multiplication-Sign 10{sup 14} h{sup -1} M{sub sun}, c{sub vir}=5.41{sup +0.49}{sub -0.45} (c{sub 200}=4.22{sup +0.40}{sub -0.36}). Tests of a range of possible systematic errors, including shear calibration and stacking-related issues, indicate that they are subdominant to the statistical errors. The concentration parameter obtained from stacking our approximately mass-selected cluster sample is broadly in line with theoretical predictions. Moreover, the uncertainty on our measurement is comparable with the differences between the different predictions in the literature. Overall, our results highlight the potential for stacked weak-lensing methods to probe the mean mass density profile of cluster-scale dark matter halos with upcoming surveys, including Hyper-Suprime-Cam, Dark Energy Survey, and KIDS.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-126: Influence of Six Dimensional Motions in Frameless Stereotactic Dosimetry Incorporating Rotational Shifts as Equivalent Translational Shifts: A Feasibility Study for Elekta-BrainLAB Stereotactic System

Purpose: Six dimensional positional shifts (translational and rotational) determined by a volumetric imaging system were mathematically combined and incorporated as simple translational shifts and the resultant impact on dose characteristics was studied. Methods: Thirty patients who underwent either single fraction (12 Gy) or five fractions (5 Gy per fraction) stereotactic treatments were included in this study. They were immobilized using a double layered thermoplastic mask from BrainLAB. Isocenter matching was done using infrared marker of ExacTrac. An initial cone beam CT (CBCT) gave positional shifts in 6-dimensions that were applied through 6-D motion enabled couch. A verification CBCT was done following corrections before treatment. These 6-D positional shifts determined at each imaging session from the first CBCT were mathematically combined to give three simple translational shifts. Doses were recalculated in the patient matrix with these positional errors present by moving the whole image dataset. Doses were also recalculated after second CBCT with only residual errors present. PTV dose statistics were compared. Results: For the approved plans V100%(PTV), V100%(GTV), D95%(PTV), D95%(GTV), D1%(PTV) and D1%(GTV) were 96.2±3.0%, 98.2±1.4%, 102%±1.7%, 103±1.2%, 107.9±8.9% and 109.3±7.5% of prescription dose respectively. With the positional errors present (after 1st CBCT) the corresponding values were 86.7±4.9%, 91.3±2.9%, 89.6±4.2%, 95.9±3.7%, 108.3±9.9% and 108.6±4.5%. Post-correction (after 2nd CBCT) with only residual errors present, values were 94.5±5.7%, 97.3±2.9%, 99.3%±3.2%, 102%±2.1%, 107.6±8.5% and 109.0±7.6% respectively. Significant and nominal OAR dose variation was observed between pre- and post-table corrections. Conclusion: Positional errors significantly affect PTV dose statistics. They need to be corrected before delivery of stereotactic treatments although the magnitude of dose changes can vary from patient-to-patient depending on the tumor location. As expected after the table corrections, residual errors result in insignificant dose deviations. For frameless stereotactic treatments having a six-dimensional motion enabled couch is highly recommended to reduce quantum of dose deviations.

60 APPLIED LIFE SCIENCES↗

Self-calibration of photometric redshift scatter in weak-lensing surveys

Photo-z errors, especially catastrophic errors, are a major uncertainty for precision weak lensing cosmology. We find that the shear-(galaxy number) density and density-density cross correlation measurements between photo-z bins, available from the same lensing surveys, contain valuable information for self-calibration of the scattering probabilities between the true-z and photo-z bins. The self-calibration technique we propose does not rely on cosmological priors nor parameterization of the photo-z probability distribution function, and preserves all of the cosmological information available from shear-shear measurement. We estimate the calibration accuracy through the Fisher matrix formalism. We find that, for advanced lensing surveys such as the planned stage IV surveys, the rate of photo-z outliers can be determined with statistical uncertainties of 0.01-1% for z < 2 galaxies. Among the several sources of calibration error that we identify and investigate, the galaxy distribution bias is likely the most dominant systematic error, whereby photo-z outliers have different redshift distributions and/or bias than non-outliers from the same bin. This bias affects all photo-z calibration techniques based on correlation measurements. As a result, galaxy bias variations of O(0.1) produce biases in photo-z outlier rates similar to the statistical errors of our method, so this galaxy distribution bias may bias the reconstructed scatters at several-σ level, but is unlikely to completely invalidate the self-calibration technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon statistical limitations for daytime optical tracking

Tracking of interplanetary spacecraft equipped with optical communication systems by using astrometric instruments is being investigated by JPL. Existing instruments are designed to work at night and, for bright sources, are limited by tropospheric errors. To provide full coverage of the solar system, astrometric tracking instruments must either be capable of daytime operation or be space-based. The integration times necessary for the ground-based daytime photon statistical errors to reach a given accuracy level (5 to 50 nanoradians) were computed for an ideal astrometric instrument. The required photon statistical integration times are found to be shorter than the tropospheric integrations times for the ideal detector. Since the astrometric need not be limited by photon statistics even under daytime conditions, it may be fruitful to investigate instruments for daytime optical tracking.

Folkner, W. M.↗

Some statistical analysis techniques for the effect of systematic instrument errors on the results of measurements in a space experiment

Mathematical models of certain systematic telemetry signal errors arising during the passage of the signal through the recording and transmitting blocks of the physical instruments aboard the spacecraft are classified and constructed. Statistical analysis methods are used to determine the background function and relative sensitivity coefficients of the channels of a charged particle detector. Results are presented. A block diagram for a method taking into account the effect of distortions is given.

Kondakov, S. P.↗

TOMOGRAPHY OF THE FERMI -LAT γ -RAY DIFFUSE EXTRAGALACTIC SIGNAL VIA CROSS CORRELATIONS WITH GALAXY CATALOGS

Building on our previous cross-correlation analysis (Xia et al. 2011) between the isotropic γ-ray background (IGRB) and different tracers of the large-scale structure of the universe, we update our results using 60 months of data from the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope (Fermi). For this study, we perform a cross-correlation analysis both in configuration and spherical harmonics space between the IGRB and objects that may trace the astrophysical sources of the IGRB: QSOs in the Sloan Digital Sky Survey (SDSS) DR6, the SDSS DR8 Main Galaxy Sample, luminous red galaxies (LRGs) in the SDSS catalog, infrared-selected galaxies in the Two Micron All Sky Survey (2MASS), and radio galaxies in the NRAO VLA Sky Survey (NVSS). The benefit of correlating the Fermi-LAT signal with catalogs of objects at various redshifts is to provide tomographic information on the IGRB, which is crucial in separating the various contributions and clarifying its origin. The main result is that, unlike in our previous analysis, we now observe a significant (>3.5σ) cross-correlation signal on angular scales smaller than 1° in the NVSS, 2MASS, and QSO cases and, at lower statistical significance (~3.0σ), with SDSS galaxies. The signal is stronger in two energy bands, E > 0.5 GeV and E > 1 GeV, but it is also seen at E > 10 GeV. No cross-correlation signal is detected between Fermi data and the LRGs. These results are robust against the choice of the statistical estimator, estimate of errors, map cleaning procedure, and instrumental effects. Finally, we test the hypothesis that the IGRB observed by Fermi-LAT originates from the summed contributions of three types of unresolved extragalactic sources: BL Lacertae objects (BL Lacs), flat spectrum radio quasars (FSRQs), and star-forming galaxies (SFGs). Finally, we find that a model in which the IGRB is mainly produced by SFGs ($72_{-37}^{+23}$% with 2σ errors), with BL Lacs and FSRQs giving a minor contribution, provides a good fit to the data. We also consider a possible contribution from misaligned active galactic nuclei, and we find that, depending on the details of the model and its uncertainty, they can also provide a substantial contribution, partly degenerate with the SFG one.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the 29-km Eta Model: Objective Verification at Three Selected Stations - Part 1

This paper describes an objective verification of the National Centers for Environmental Prediction (NCEP) 29-km eta model from May 1996 through January 1998. The evaluation was designed to assess the model's surface and upper-air point forecast accuracy at three selected locations during separate warm (May - August) and cool (October - January) season periods. In order to enhance sample sizes available for statistical calculations, the objective verification includes two consecutive warm and cool season periods. Systematic model deficiencies comprise the larger portion of the total error in most of the surface forecast variables that were evaluated. The error characteristics for both surface and upper-air forecasts vary widely by parameter, season, and station location. At upper levels, a few characteristic biases are identified. Overall however, the upper-level errors are more nonsystematic in nature and could be explained partly by observational measurement uncertainty. With a few exceptions, the upper-air results also indicate that 24-h model error growth is not statistically significant. In February and August 1997, NCEP implemented upgrades to the eta model's physical parameterizations that were designed to change some of the model's error characteristics near the surface. The results shown in this paper indicate that these upgrades led to identifiable and statistically significant changes in forecast accuracy for selected surface parameters. While some of the changes were expected, others were not consistent with the intent of the model updates and further emphasize the need for ongoing sensitivity studies and localized statistical verification efforts. Objective verification of point forecasts is a stringent measure of model performance, but when used alone, is not enough to quantify the overall value that model guidance may add to the forecast process. Therefore, results from a subjective verification of the meso-eta model over the Florida peninsula are discussed in the companion paper by Manobianco and Nutter. Overall verification results presented here and in part two should establish a reasonable benchmark from which model users and developers may pursue the ongoing eta model verification strategies in the future.

Nutter, Paul A.↗

Charm quark system at the physical point of 2+1 flavor lattice QCD

We investigate the charm quark system using the relativistic heavy quark action on 2+1 flavor PACS-CS configurations previously generated on 32{sup 3} x 64 lattice. The dynamical up, down, and strange quark masses are set to the physical values by using the technique of reweighting to shift the quark-hopping parameters from the values employed in the configuration generation. At the physical point, the lattice spacing equals a{sup -1} = 2.194(10) GeV and the spatial extent L = 2.88(1) fm. The charm quark mass is determined by the spin-averaged mass of the 1S charmonium state, from which we obtain m{sub charm}{sup M{bar S}} ({mu} = m{sub charm}{sup M{bar S}}) = 1.260(1)(6)(35) GeV, where the errors are due to our statistics, scale determination and renormalization factor. An additional systematic error from the heavy quark is of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}, which are estimated to be a percent level if the factor f(m{sub Q}a) analytic in m{sub Q}a is of order unity. Our results for the charmed and charmed-strange meson decay constants are f{sub D} = 226(6)(1)(5) MeV, f{sub D}{sub s} = 257(2)(1)(5) MeV, again up to the heavy quark errors of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}. Combined with the CLEO values for the leptonic decay widths, these values yield |V{sub cd}| = 0.205(6)(1)(5)(9), |V{sub cs}| = 1.00(1)(1)(3)(3), where the last error is because of the experimental uncertainty of the decay widths.

2+1↗

Charm quark system at the physical point of 2+1 flavor lattice QCD

We investigate the charm quark system using the relativistic heavy quark action on 2+1 flavor PACS-CS configurations previously generated on 32{sup 3}x64 lattice. The dynamical up, down, and strange quark masses are set to the physical values by using the technique of reweighting to shift the quark-hopping parameters from the values employed in the configuration generation. At the physical point, the lattice spacing equals a{sup -1}=2.194(10) GeV and the spatial extent L=2.88(1) fm. The charm quark mass is determined by the spin-averaged mass of the 1S charmonium state, from which we obtain m{sub charm}{sup MS}({mu}=m{sub charm}{sup MS})=1.260(1)(6)(35) GeV, where the errors are due to our statistics, scale determination and renormalization factor. An additional systematic error from the heavy quark is of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}, which are estimated to be a percent level if the factor f(m{sub Q}a) analytic in m{sub Q}a is of order unity. Our results for the charmed and charmed-strange meson decay constants are f{sub D}=226(6)(1)(5) MeV, f{sub D{sub s}}=257(2)(1)(5) MeV, again up to the heavy quark errors of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}. Combined with the CLEO values for the leptonic decay widths, these values yield |V{sub cd}|=0.205(6)(1)(5)(9), |V{sub cs}|=1.00(1)(1)(3)(3), where the last error is because of the experimental uncertainty of the decay widths.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error Representation in Time For Compressible Flow Calculations

Time plays an essential role in most real world fluid mechanics problems, e.g. turbulence, combustion, acoustic noise, moving geometries, blast waves, etc. Time dependent calculations now dominate the computational landscape at the various NASA Research Centers but the accuracy of these computations is often not well understood. In this presentation, we investigate error representation (and error control) for time-periodic problems as a prelude to the investigation of feasibility of error control for stationary statistics and space-time averages. o These statistics and averages (e.g. time-averaged lift and drag forces) are often the output quantities sought by engineers. o For systems such as the Navier-Stokes equations, pointwise error estimates deteriorate rapidly which increasing Reynolds number while statistics and averages may remain well behaved.

Barth, Timothy J.↗

Type Ia Supernova Growth-rate Measurement with LSST Simulations: Intrinsic Scatter Systematics

Measurement of the growth rate of structures (fσ 8 ) with Type Ia supernovae (SNe Ia) will improve our understanding of the nature of dark energy and enable tests of general relativity. In this paper, we generate simulations of the 10 yr SN Ia data set of the Rubin-LSST survey, including a correlated velocity field from an N-body simulation and realistic models of SNe Ia properties and their correlations with host-galaxy properties. We find, similar to SN Ia analyses that constrain the dark energy equation-of-state parameters w 0 w a , that constraints on fσ 8 can be biased depending on the intrinsic scatter of SNe Ia. While for the majority of intrinsic scatter models we recover fσ 8 with a precision of ∼13%–14%, for the most realistic dust-based model, we find that the presence of non-Gaussianities in Hubble diagram residuals leads to a bias on fσ 8 of ∼ −20%. When trying to correct for the dust-based intrinsic scatter, we find that the propagation of the uncertainty on the model parameters does not significantly increase the error on fσ 8 . We also find that while the main component of the error budget of fσ 8 is the statistical uncertainty (>75% of the total error budget), the systematic error budget is dominated by the uncertainty on the damping parameter, σ u , that gives an empirical description of the effect of redshift space distortions on the velocity power spectrum. Our results motivate a search for new methods to correct for the non-Gaussian distribution of the Hubble diagram residuals, as well as an improved modeling of the damping parameter.

Carreres, Bastien [Duke Univ., Durham, NC (United ↗

Application of Statistical Filter Theory to the Optimal Estimation of Position and Velocity on Board a Circumlunar Vehicle

Concepts from statistical filter theory are applied to the problem of in-flight determination of the position and velocity of a space vehicle for the purposes of midcourse guidance. The source of information is assumed to be an arbitrary sequence of measurements of any desired set of "observables" (e.g., space angles), the measurements being corrupted by additive errors so that the position and velocity are never known perfectly. A state transition approach is employed which leads naturally to a computational scheme that is readily implemented by a digital computer. The scheme can be regarded as a dynamical time-varying filter which weights the incoming observations in an optimal sense for use in producing an up-to-date optimal estimate of position and velocity. The advantages of the scheme are (1) it provides the best possible estimate (minimum error) based upon ensemble statistics of injection conditions and measurement errors; (2) it is extremely versatile, not requiring adherence to a predetermined observation schedule or reference trajectory; and (3) the computations are sufficiently simple to be practical in an on-board computer. A digital computer simulation of the proposed system is employed to demonstrate the feasibility of an all on-board system and to illustrate the performance attainable in a hypothetical physical situation.

SPACE VEHICLE↗

A Markov model for NASA's Ground Communications Facility

A 'natural' way of constructing finite-state Markov chains (FSMC) is presented for those noise burst channels that can be modeled by them. In particular, a five-state Markov chain is given as a model of errors occurring at the Ground Communications Facility (GCF). A maximum likelihood procedure applicable to any FSMC is developed for estimating all the model parameters starting from the data of error runs. A few of the statistics important for estimating the performance of error control strategies on the channel are provided.

Adeyemi, O.↗

A technique for evaluating the application of the pin-level stuck-at fault model to VLSI circuits

Accurate fault models are required to conduct the experiments defined in validation methodologies for highly reliable fault-tolerant computers (e.g., computers with a probability of failure of 10 to the -9 for a 10-hour mission). Described is a technique by which a researcher can evaluate the capability of the pin-level stuck-at fault model to simulate true error behavior symptoms in very large scale integrated (VLSI) digital circuits. The technique is based on a statistical comparison of the error behavior resulting from faults applied at the pin-level of and internal to a VLSI circuit. As an example of an application of the technique, the error behavior of a microprocessor simulation subjected to internal stuck-at faults is compared with the error behavior which results from pin-level stuck-at faults. The error behavior is characterized by the time between errors and the duration of errors. Based on this example data, the pin-level stuck-at fault model is found to deliver less than ideal performance. However, with respect to the class of faults which cause a system crash, the pin-level, stuck-at fault model is found to provide a good modeling capability.

Palumbo, Daniel L.↗

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs

Effective and efficient health management of sensing channels and instrumentation supports reliable and accurate process monitoring capacities in any industry. Current practice in the nuclear industry relies on periodic calibration assessment and correction activities. This time based maintenance technique consists of three steps: i) removal of sensor to a test environment, ii) testing and recalibration, and iii) reinstallation of sensor into its working environment. This procedure is highly labor intensive, adds to the outage cost and timeline, and contributes to worker radiation exposure and ALARA requirements. Furthermore, the human element contributes to error factors in all stages of the procedure. The effectiveness of this calibration procedure after sensors are returned to working environmental variables also raises concerns, and the practicability of this periodic approach is uncertain for future reactor designs with longer operating cycles between refueling outages. Studies indicate that periodic calibration assessment find only 10% of sensing instrumentations with calibration issues during a single outage (18- 24 months), meaning at least 90% of sensors are undergoing unnecessary maintenance actions. This provides an opportunity to maintain the current levels of safety and functional integrity with fewer, more targeted maintenance actions and lower economic burden. Performance-based maintenance planning shows much promise over current periodic maintenance approaches. Specifically, online monitoring (OLM) utilizes the continually collected process data to non-intrusively monitor the calibration status of process instrumentation and detect the onset of de-calibration, thereby minimizing the number of recalibration procedures required. Ultimately, this can lead to termination of time based recalibration at NPPs. OLM utilizes the process measurements made for process monitoring and control to evaluate the calibration status of the sensors and instrumentation making the measurements. OLM can detect and differentiate sensor faults and process anomalies, thus providing a valuable tool to suit the industry's and regulatory body's requirements. Though supported by more than a decade of research, OLM for sensor calibration assessment is yet to be implemented in the US fleet due to regulatory requirements and constraints. As shown in Figure 1, OLM utilizes process data to train statistical models that predict normal, error-free process behavior. Measured process values are compared with error-corrected predictions to ascertain the presence of faults. The reliability of OLM is dependent on the quality of its predictions, measured in part by the uncertainty in these predictions. This research develops a framework to accurately quantify the prediction uncertainty based on Bayesian inference techniques to provide the required confidence levels for OLM systems. The expected outcomes include signal validation by high-accuracy, high-confidence uncertainty quantification for variable sensor types and operating ranges. Furthermore, the framework will facilitate fault detection capacities and so-called virtual sensors, a capability to replace faulty sensor measurements with error-corrected values when a sensor fault is detected. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-eddy simulation of heavy particle dispersion in wall-bounded turbulent flows

Capabilities and accuracy issues in Lagrangian tracking of heavy particles in velocity fields obtained from large-eddy simulations (LES) of wall-bounded turbulent flows are reviewed. In particular, it is shown that, if no subgrid scale (SGS) model is added to the particle motion equations, particle preferential concentration and near-wall accumulation are significantly underestimated. Results obtained with SGS modeling for the particle motion equations based on approximate deconvolution are briefly recalled. Then, the error purely due to filtering in particle tracking in LES flow fields is singled out and analyzed. The statistical properties of filtering errors are characterized in turbulent channel flow both from an Eulerian and a Lagrangian viewpoint. Implications for stochastic SGS modeling in particle motion equations are briefly outlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗