Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

The National Climate Database (NCDB): An Unbiased 100-Year Dataset for PV Modeling

In this study, we develop a statistical technique to downscale the future projection of solar irradiance for photovoltaics (PV) energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the downscaling method, a summary of the 100-year dataset from 2001-2100, and future extension of this research.

bias correction↗

Optimal binning of correlated measurements

Experimental measurements are commonly represented on a discrete grid, requiring a balance between granularity and statistical noise. Two strategies have traditionally been used to improve such representations: selecting an appropriate bin width to control discretization error and applying kernel-based smoothing to suppress fluctuations. Despite their shared goal, these approaches have largely developed independently, without a unified statistical description of how discretization and correlation jointly determine measurement precision. Here, we extend the discussion of optimal interval averaging to a correlation-aware setting by Gaussian process regression, which explicitly accounts for correlations among neighboring bins. Starting from first principles, we derive the mean-squared error of discretized measurements and obtain closed-form asymptotic expressions for the optimal bin width and correlation length. When recast in reduced variables, the theory reveals distinct universal scaling laws governing the error in the correlation-free and correlation-controlled regimes. Characterized by intrinsically smooth intensity profiles and counting-based statistics, neutron scattering measurements are well suited for demonstrating the enhanced error contraction enabled by inter-bin correlations. We show that such improvement is achievable over the experimentally accessible Q-range and across multiple instruments and material systems. These results show that explicitly accounting for correlations systematically reshapes the limits of precision in discretized, noise-limited measurements. More broadly, the framework provides a transferable statistical foundation for optimizing data representation, inference, and experimental design across the physical and data sciences.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

2D-3D registration for prostate radiation therapy based on a statistical model of transmission images

Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D-3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model-based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of 3 mm for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone-beam CT (CBCT) and kV projection radiographs of the phantom in the anterior-posterior (AP) view, registration accuracies were 0.42 mm (MLP), 0.29 mm (MLG), and 0.29 mm (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were 1.15 mm (MLP), 0.90 mm (MLG), and 0.69 mm (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eigenstate thermalization hypothesis and approximate quantum error correction

The eigenstate thermalization hypothesis (ETH) is a powerful conjecture for understanding how statistical mechanics emerges in a large class of many-body quantum systems. It has also been interpreted in a CFT context, and, in particular, holographic CFTs are expected to satisfy ETH. Recently, it was observed that the ETH condition corresponds to a necessary and sufficient condition for an approximate quantum error correcting code (AQECC), implying the presence of AQECCs in systems satisfying ETH. In this paper, we explore the properties of ETH as an error correcting code and show that there exists an explicit universal recovery channel for the code. Based on the analysis, we discuss a generalization that all chaotic theories contain error correcting codes. We then specialize to AdS/CFT to demonstrate the possibility of total bulk reconstruction in black holes with a well-defined macroscopic geometry. When combined with the existing AdS/CFT error correction story, this shows that black holes are enormously robust against erasure errors.

97 MATHEMATICS AND COMPUTING↗

Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p < 0.05). Mean intrafractional setup errors with use of the Body Pro-Lok system were as follows: X, 0.41 ± 0.46 mm; Y, 0.86 ± 0.80 mm; Z, 0.33 ± 0.44 mm; and roll, 0.12 ± 0.19°. Mean liver-induced respiratory motion determinations were as follows: (1) abdominal compression: X, 2.33 ± 1.22 mm; Y, 5.11 ± 2.05 mm; Z, 2.13 ± 1.05 mm; and 3D vector, 6.22 ± 1.94 mm; and (2) free breathing: X, 3.48 ± 1.14 mm; Y, 9.83 ± 3.00 mm; Z, 3.38 ± 1.59 mm; and 3D vector, 11.07 ± 3.16 mm. Between-group differences were statistically different in 4 directions (p < 0.05). Conclusions: The Body Pro-Lok system is capable of improving interfractional and intrafractional setup accuracy and minimizing tumor movement owing to respirations in patients with intrahepatic HCC during hypofractionated helical tomotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlated Statistical Uncertainties in Coded-Aperture Imaging

In nuclear security applications, coded-aperture imagers provide the opportu- nity for a wealth of information regarding the attributes of both the radioac- tive and non-radioactive components of the objects being imaged. However, for optimum benefit to the community, spatial attributes need to be deter- mined in a quantitative and statistically meaningful manner. To address the deficiency of quantifiable errors in coded-aperture imaging, we present uncer- tainty matrices containing covariance terms between image pixels for MURA mask patterns. We calculated these correlated uncertainties as functions of variation in mask rank, mask pattern over-sampling, and whether or not anti- mask data are included. Utilizing simulated point source data, we found that correlations (and inverse correlations) arose when two or more image pixels were summed. Furthermore, we found that the presence of correlations (and their inverses) was heightened by the process of over-sampling, while correla- tions were suppressed by the inclusion of anti-mask data and with increased mask rank. As an application of this result, we explore how statistics-based alarming in nuclear security is impacted.

Fleenor, Matthew C↗

Quantifying Errors in Effective Cluster Interactions of Lattice Gas Cluster Expansions

The promise of lattice gas (LG) cluster expansions (CEs) is that they can describe a given system property to any level of accuracy since the orthogonal “cluster basis functions” span the complete space of available configurations. Such an approach can be constructed to an arbitrarily large surface of a finite number of distinct adsorption sites. Unfortunately, this is only true for the case of an ideal, fixed lattice decorated with components at precise lattice points (the lattice “sites”) with no distortions or relaxations subsequently allowed. Since most systems, and surfaces specifically, do not conform to such an ideal set of constraints, errors in LG CEs must be expected or CE convergence severely hampered. Beyond this, numerical errors in the provided data can complicate the proper construction of a truly predictive and/or physically significant CE. In this work, we show here how reliance on typical statistical tools like confidence intervals cannot be expected to provide an accurate representation of the uncertainty of effective cluster interactions (ECIs) in the CE due to the nature of the target ab initio data and the nature of CEs themselves. We develop a method for estimating these errors that does not rely on statistical assumptions about the model or data. We then use these ECI errors to quantify fundamental consequences on the uncertainty of ECIs in CEs built from O/Fe(100) data whose surface and adsorbates have been allowed to relax in a typical manner and from O/Fe(100) data whose surface and adsorbates are fixed in ideal lattice positions. We also quantify the effect of using a different density functional theory exchange–correlation functional, using these ECI errors to assess the significance in any deviations. In both cases, our method is shown to have remarkable utility in the quantification of errors in the ECIs of CEs. While we stick to the lattice gas convention in this work, the method is equally applicable to the Ising convention or, in principle, any linear model of sufficient complexity.

08 HYDROGEN↗

Median statistics estimate of the galactic rotational velocity

We compile a complete collection of 18 recent (from 2000 to 2017) measurements of Θ 0 , the rotational velocity of the Milky Way at R 0 (the radial distance of the Sun from the Galactic center). These measurements use tracers that are believed to more accurately reflect the systematic rotation of the Milky Way. Unlike other recent compilations of Θ 0 , our collection includes only independent measurements. We find that these 18 measurements are distributed in a mildly non-Gaussian fashion and a median statistics estimate indicates Θ 0 = 220 ± 10 kms –1 (2σ error) as the most reliable summary, at R 0 = 8.0 ± 0.3 kpc (2σ error).

(cosmology:) cosmological parameters↗

Statistical Projections for Multi-resolution, Multi-dimensional Visual Data Exploration and Analysis

An ongoing challenge in visual exploration and analysis of large, multi-dimensional datasets is how to present useful, concise information to a user for some specific visualization tasks. Typical approaches to this problem have proposed either reduced-resolution versions of data, or projections of data, or both. These approaches still have some limitations such as consuming high computation or suffering from errors. In this work, we explore the use of a statistical metric as the basis for both projections and reduced-resolution versions of data, with a particular focus on preserving one key trait in data, namely variation. We use two different case studies to explore this idea, one that uses a synthetic dataset, and another that uses a large ensemble collection produced by an atmospheric modeling code to study long-term changes in global precipitation. The primary findings of our work are that in terms of preserving the variation signal inherent in data, that using a statistical measure more faithfully preserves this key characteristic across both multi-dimensional projections and multi-resolution representations than a methodology based upon averaging.

54 ENVIRONMENTAL SCIENCES↗

Polarimeter Development for an Electric Dipole Moment Search in a Storage Ring

The search for a charged particle EDM in a storage ring with the goal of a statistical sensitivity of 10 -29 ecenterdotcm/year requires a very sensitive polarimeter. Studies described here have shown that systematic error effects can be handled and corrected to a sensitivity better than the required 10 -6 level. The required statistical precision was shown to be attainable using a thick scattering target onto which the stored beam is slowly extracted. Models for geometric and rate systematic error effects describe the results well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Leveraging interpolation models and error bounds for verifiable scientific machine learning

Effective verification and validation techniques for modern scientific machine learning workflows are challenging to devise. Statistical methods are abundant and easily deployed, but often rely on speculative assumptions about the data and methods involved. Error bounds for classical interpolation techniques can provide mathematically rigorous estimates of accuracy, but often are difficult or impractical to determine computationally. Here, in this work, we present a best-of-both-worlds approach to verifiable scientific machine learning by demonstrating that (1) multiple standard interpolation techniques have informative error bounds that can be computed or estimated efficiently; (2) comparative performance among distinct interpolants can aid in validation goals; (3) deploying interpolation methods on latent spaces generated by deep learning techniques enables some interpretability for black-box models. We present a detailed case study of our approach for predicting lift-drag ratios from airfoil images. Code developed for this work is available in a public Github repository.

97 MATHEMATICS AND COMPUTING↗

Study of different filtering techniques applied to spectra from airborne gamma spectrometry

One of the features of spectra obtained by airborne gamma spectrometry is low counting statistics due to the short acquisition time (1 s) and the large source-detector distance (40 m). It leads to considerable uncertainty in radionuclide identification and determination of their respective activities from the windows method recommended by the IAEA, especially for low-level radioactivity. The present work compares the results obtained with filters in terms of errors of the filtered spectra with the window method and over the whole gamma energy range. The results are used to determine which filtering technique is the most suitable in combination with some method for total stripping of the spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the elements of Earth's radiative budget: Applying uncertainty quantification to the CESM

Understanding and characterizing sources of uncertainty in climate modeling is an important task. Because of the ever increasing sophistication and resolution of climate modeling it is increasing important to develop uncertainty quantification methods that minimize the computational cost that occurs when these methods are added to climate modeling. This research explores the application of sparse stochastic collocation with polynomial edge detection to characterize portions of the probability space associated with the Earth's radiative budget in the Community Earth System Model (CESM). Specifically, we develop surrogate models with error estimates for a range of acceptable input parameters that predict statistical values of the Earth's radiative budget as derived from the CESM simulation.

42 ENGINEERING↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Isovector Axial Charge and Form Factors of Nucleons from Lattice QCD

A survey of the calculations of the isovector axial vector form factor of the nucleon using lattice QCD is presented. Attention is paid to statistical and systematic uncertainties, in particular those due to excited state contributions. Based on a comparison of results from various collaborations, a case is made that lattice results are consistent within 10%. A similar level of uncertainty is in the axial charge gAu−d, the mean squared axial charge radius ⟨rA2⟩, the induced pseudoscalar charge gP∗, and the pion–nucleon coupling gπNN. Even with the current methodology, a significant reduction in errors is expected over the next few years with higher statistics data on more ensembles closer to the physical point. Lattice QCD results for the form factor GA(Q2) are compatible with those obtained from the recent MINERνA experiment but lie 2–3σ higher than the phenomenological extraction from the old ν–deuterium bubble chamber scattering data for Q2>0.3 GeV2. Current data show that the dipole ansatz does not have enough parameters to fit the form factor over the range 0≤Q2≤1 GeV2, whereas even a z2 truncation of the z expansion or a low order Padé are sufficient. Looking ahead, lattice QCD calculations will provide increasingly precise results over the range 0≤Q2≤1 GeV2, and MINERνA-like experiments will extend the range to Q2∼2 GeV2 or higher. Nevertheless, improvements in lattice methods to (i) further control excited state contributions and (ii) extend the range of Q2 are needed.

Astronomy & Astrophysics↗