Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Addiction circuitry in the human brain (*).

A major challenge in understanding substance-use disorders lies in uncovering why some individuals become addicted when exposed to drugs, whereas others do not. Although genetic, developmental, and environmental factors are recognized as major contributors to a person's risk of becoming addicted, the neurobiological processes that underlie this vulnerability are still poorly understood. Imaging studies suggest that individual variations in key dopamine-modulated brain circuits, including circuits involved in reward, memory, executive function, and motivation, contribute to some of the differences in addiction vulnerability. A better understanding of the main circuits affected by chronic drug use and the influence of social stressors, developmental trajectories, and genetic background on these circuits is bound to lead to a better understanding of addiction and to more effective strategies for the prevention and treatment of substance-use disorders.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerated Testing Validation

The DOE Fuel Cell technical team recommended ASTs were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. The quantitative correlation of the degradation rates will have to take into account the various stressors in the field including temperature, relative humidity, start/stops and voltage cycles.

08 HYDROGEN↗

An Assessment of Uncertainty in Remaining Life Estimation for Nuclear Structural Materials

In recent years, several operating US light-water nuclear power reactors (LWRs) have moved to extended-life operations (from 40 years to 60 years), and there is interest in the feasibility of extending plant life to 80 years. Operating experience suggests that material degradation of structural components in LWRs (such as the reactor pressure vessel) is expected to be the limiting factor for safe operation during extended life. Therefore, a need exists for assessing the condition of LWR structural components and determining its remaining useful life (RUL). The ability to estimate RUL of degraded structural components provides a basis for determining safety margins (i.e., whether safe operation over some pre-determined time horizon is possible), and scheduling degradation management activities (such as potentially modifying operating conditions to limit further degradation growth). A key issue in RUL estimation is calculation of uncertainty bounds, which are dependent on current material state, as well as past and future stressor levels (such as time-at-temperature, pressure, and irradiation). This paper presents a preliminary empirical investigation into the uncertainty of RUL estimates for nuclear structural materials.

Bayesian Prognostics↗

Physics-Based Multi-State Models of Passive Component Degradation for the R7 Reactor Simulation Environment

Abstract: The Next Generation Systems Analysis Code - referred to as R7 - is reactor systems simulation software being developed to support the Risk-Informed Safety Margin Characterization Pathway of the U.S. Department of Energy's Light Water Reactor Sustainability Program. It will provide an integrated multi-physics environment, implemented in an uncertainty quantification (UQ) framework that can produce risk and other performance insights on long-term reactor operations. An element of this simulation environment will be the performance of passive components and materials. Conventional models of component reliability are largely parametric, relying on plant service data to estimate component lifetimes and failure rates. This type of model has limited usefulness in the R7 environment where the intent is to explicitly determine the influence of physical stressors on component degradation. In this paper, we describe a new class of multi-state physics-based component models designed to be R7-compatible. These models capture the physics of materials degradation while also incorporating the effects of interventions and component rejuvenation. The models are implemented in a cumulative damage framework that allows the impact of an evolving physical environment to be addressed without recourse to resampling within the Monte Carlo-based UQ framework. The paper describes an application to stress corrosion cracking in dissimilar metal welds - a principal contributor to potential loss of coolant accidents. So while R7 will have the more conventional capability of reactor simulation codes to model the impact of degraded components and systems on plant performance, the methodology described here allows R7 to model the inverse effect; the impact of the physical environment on component degradation and performance.

PRA, passive components, stress corrosion cracking↗

COMPLIANCE STUDIES: WHAT ABOUT THE FISH?

ABSTRACT It is understood that operational and structural conditions at hydroelectric facilities along with environmental conditions of the migration corridors affect the passage conditions for fish. Hydropower fish survival assessments at the individual- and population-level have progressed over the past decade with development of turbine simulation software and improvements in telemetry systems, in particular, micro-transmitters, cabled and autonomous receivers, and advanced statistical designs that provide precise estimates of passage routes and dam-passage survival. However, these approaches often ignore fish condition as a variable in passage and survival analyses. To account for fish condition effects on survival results, compliance statistical models often require increased numbers of tagged fish. For example, prior to and during migration, fish encounter numerous stressors (e.g., disease, predation, contact with structures, decompression events), all of which can cause physical and physiological stress, altering the probability of survival after passage through a dam or a series of dams. In addition, the effects of surgical transmitter implantation process or the transmitter itself may cause physiological stress, alter behavior, and/or decrease survival. Careful physiological evaluations can augment survival model assumptions, resultant data, and predictive scenarios. To exemplify this, surgeons concurrently noted fish condition and surgical implantation during a multi-dam compliance study in 2011. The analyses indicted that surgeon observations on fish condition and surgical outcomes were related to 24 h holding mortalities and fish that never detected after release. Short reach and long reach survival were related to surgical outcomes and fish condition, respectively.

hydropower, hydrokinetics,↗

URBAN-NET: A Network-based Infrastructure Monitoring and Analysis System for Emergency Management and Public Safety

Abstract Critical Infrastructures (CIs) such as energy, water, and transportation are complex networks that are crucial for sustaining day-to-day commodity flows vital to national security, economic stability, and public safety. The nature of these CIs is such that failures caused by an extreme weather event or a man-made incident can trigger widespread cascading failures, sending ripple effects at regional or even national scales. To minimize such effects, it is critical for emergency responders to identify existing or potential vulnerabilities within CIs during such stressor events in a systematic and quantifiable manner and take appropriate mitigating actions. We present here a novel critical infrastructure monitoring and analysis system named URBAN-NET. The system includes a software stack and tools for monitoring CIs, pre-processing data, interconnecting multiple CI datasets as a heterogeneous network, identifying vulnerabilities through graph-based topological analysis, and predicting consequences based on what-if simulations along with visualization. As a proof-of-concept, we present several case studies to show the capabilities of our system. We also discuss remaining challenges and future work.

Lee, Sangkeun↗

Sensor Fish: an autonomous sensor package for characterizing complex flow fields and fish passage

Fish passing through dams or other hydraulic structures may be injured or killed despite advances in turbine design, project operations, and other fish bypass systems. The Sensor Fish (SF) device is an autonomous sensor package that characterizes the physical conditions and stressors to which fish are exposed during passage through hydro facilities. It was designed to move passively as a neutrally buoyant object through severe hydraulic environments, while collecting high-resolution sensor data. Since its first generation1, the SF device has been successfully deployed in many fish passage studies and has evolved to be a major tool for characterizing fish passage conditions during fish passage in the Columbia River Basin. To better accelerate hydropower development, the U.S. Department of Energy Water Power Program provided funding to develop a new generation (Gen 2 SF) to incorporate more capabilities and accommodate a wider range of users over a broader range of turbine designs and operating environments. The Gen 2 SF (Figure 1) is approximately the size and density of a yearling salmon smolt and is nearly neutrally buoyant. It contains three-dimensional (3D) rotation sensors, 3D linear acceleration sensors, a pressure sensor, a temperature sensor, a 3D orientation sensor, a radiofrequency (RF) transmitter, and a recovery module2. A low-power microcontroller collects data from the sensors and stores up to 5 min of data on internal flash memory at a sampling frequency of 2048 Hz. The recovery module makes the SF positively buoyant after a pre-programmed period of time, causing it to float to the surface for recovery.

Sensor Fish↗

Linking Adverse Outcome Pathways to Dynamic Energy Budgets: A Conceptual Model

Ecological risk assessment quantifies the likelihood of undesirable impacts of stressors, primarily at high levels of biological organization. Data used to inform ecological risk assessments come primarily from tests on individual organisms or from suborganismal studies, indicating a disconnect between primary data and protection goals. We know how to relate individual responses to population dynamics using individual-based models, and there are emerging ideas on how to make connections to ecosystem services. However, there is no established methodology to connect effects seen at higher levels of biological organization with suborganismal dynamics, despite progress made in identifying Adverse Outcome Pathways (AOPs) that link molecular initiating events to ecologically relevant key events. This chapter is a product of a working group at the National Center for Mathematical and Biological Synthesis (NIMBioS) that assessed the feasibility of using dynamic energy budget (DEB) models of individual organisms as a “pivot” connecting suborganismal processes to higher level ecological processes. AOP models quantify explicit molecular, cellular or organ-level processes, but do not offer a route to linking sub-organismal damage to adverse effects on individual growth, reproduction, and survival, which can be propagated to the population level through individual-based models. DEB models describe these processes, but use abstract variables with undetermined connections to suborganismal biology. We propose linking DEB and quantitative AOP models by interpreting AOP key events as measures of damage-inducing processes in a DEB model. Here, we present a conceptual model for linking AOPs to DEB models and review existing modeling tools available for both AOP and DEB.

Murphy, Cheryl↗

A Synopsis of Global Mapping of Freshwater Habitats and Biodiversity: Implications for Conservation

Accurately mapping freshwater habitats and biodiversity at high-resolutions across the globe is essential for assessing the vulnerability and threats to freshwater organisms and prioritizing conservation efforts. Since the 2000s, extensive efforts have been devoted to mapping global freshwater habitats (rivers, lakes, and wetlands), the spatial representation of which has changed dramatically over time with new geospatial data products and improved remote sensing technologies. Some of these mapping efforts, however, are still coarse representations of actual conditions. Likewise, the resolution and scope of global freshwater biodiversity compilation efforts have also increased, but are yet to mirror the spatial resolution and fidelity of mapped freshwater environments. In our synopsis, we find that efforts to map freshwater habitats have been conducted independently of those for freshwater biodiversity; subsequently, there is little congruence in the spatial representation and resolution of the two efforts. We suggest that global species distribution models are needed to fill this information gap; however, limiting data on habitat characteristics at scales that complement freshwater habitats has prohibited global high-resolution biogeography efforts. Emerging research trends, such as mapping habitat alteration in freshwater ecosystems and trait biogeography, show great promise in mechanistically linking global anthropogenic stressors to freshwater biodiversity decline and extinction risk.

Mcmanamay, Ryan↗

GaAs Solar Cells Grown on Unpolished, Spalled Ge Substrates: Preprint

Decreasing the cost of single-crystal substrates by wafer reuse techniques has long been sought for III-V solar cells. Controlled spalling of III-V devices is a possible pathway for epitaxial liftoff, which would help reduce costs, but chemo- mechanical polishing after liftoff tends to limit the potential cost savings. Growth on an unpolished spalled surface would be an additional step toward lower costs, but it is crucial to show high efficiency solar cell devices on these unprocessed substrates. In this study, we spalled 2-inch Ge wafers using a Ni stressor layer, and then grew GaAs solar cells by HVPE on the spalled Ge surface without any other surface treatment. We show a 12.8% efficient single-junction device, without anti-reflection coating, with quantum efficiency very close to identical devices grown by HVPE on non-spalled GaAs substrates. Demonstrating a high carrier collection on unpolished spalled wafers is a step toward reducing substrate-related liftoff and reuse costs.

14 SOLAR ENERGY↗

GaAs Solar Cells with High Carrier Collection Grown on Unpolished, Spalled Ge Substrates: Preprint

Decreasing the cost of single-crystal substrates has long been sought for III-V solar cells. Controlled spalling is a possible pathway for epitaxial liftoff, which would help reduce costs, but chemo-mechanical polishing after liftoff tends to limit the impact. Growth on an unpolished spalled surface would be an additional step toward lower costs, but it is crucial to show high efficiency solar cell devices on these unprocessed substrates. In this study, we spalled 2 inch Ge wafers using a Ni stressor layer, and GaAs solar cells are grown by HVPE on the spalled Ge surface without any other surface treatment. We show a 12.8% efficient device, without anti-reflection coating, with equivalent quantum efficiency as identical devices grown by HVPE on non-spalled GaAs substrates. Demonstrating a high carrier collection on unpolished spalled wafers is the first step toward reducing substrate-related liftoff and polishing costs.

14 SOLAR ENERGY↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

For predicting the reliability and lifetime of Photovoltaic (PV) inverters, thermal cycling is considered the most important stressors in the inverter system. To realize this, a detailed electrothermal model of the PV inverter was developed along with the controllers. The model was verified by developing an in-house inverter, which was placed inside a thermal chamber to verify the losses and temperature rise within the system at various temperatures. After the verification of the model, a reduced order model of the inverter was implemented which can translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The estimated junction temperature data was used to identify the reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system was studied. Experiments show that lifetime and reliability of the inverter decreases as the operating power factor decreases from unity. The results are presented and discussed here.

14 SOLAR ENERGY↗

The effects of Suspended Sediment on Japanese Medaka (Oryzias latipes) and Mosquitofish (Gambusia affinis) Metabolism

Sedimentation is recognized as a significant environmental stressor in aquatic ecosystems and high amounts of suspended sediments (SS) in streams are known to negatively affect aquatic organisms. In particular, it has been hypothesized that many fish species may exhibit increased respiration rates when exposed to elevated SS. To evaluate this hypothesis, we evaluated the acute response (3 hour exposure) of two small, freshwater fish species exposed to high suspended sediment loads using experimental respirometry chambers which measure oxygen consumption as a proxy of metabolism. Our results indicate that Japanese Medaka (Oryzias latipes) did not exhibit a significantly greater oxygen consumption, as compared to control fish, when exposed to chamber sediment of 0.17 g/L (p-value of 0.41), though oxygen consumption was higher for sediment treatments. However, mosquitofish (Gambusia affinis) exposed to 0.17 g/L did exhibit noticeably greater oxygen consumption compared to fish in no-sediment control test, but not at statistically significant levels (p-value of 0.07). In this work, further study is needed with increased sample sizes and across SS levels to determine the threshold of increased metabolic rate among freshwater species exposed to SS.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Experimental Aging and Lifetime Prediction in Grid Applications for Large-Format Commercial Li-Ion Batteries

Due to the growth of electric vehicle and stationary energy storage markets, the production and use of lithium-ion batteries has grown exponentially in recent years. For many of these applications, large-format lithium-ion batteries are being utilized, as large cells have less inactive material relative to their energy capacity and require fewer electrical connections to assemble into packs. And especially for stationary energy storage systems, where energy delivered is the only revenue source, the economics of these battery systems is highly dependent on cell lifetime. However, testing of large-format lithium-ion batteries is time consuming and requires high current channels and large testing chambers, making information on the performance of commercial, large-format lithium-ion batteries hard to come by. Here, accelerated aging test data from four commercial large-format lithium-ion batteries is reported. These batteries span both NMC-Gr and LFP-Gr cell chemistries, pouch and prismatic formats, and a range of cell designs with varying power capabilities. Accelerated aging test results are analyzed to examine both cell performance, in terms of efficiency and thermal response under load, as well as cell lifetime. Cell thermal response is characterized by measuring temperature during cycle aging, which is used to calculated a normalized thermal resistance value that may help estimate both cell cooling needs or to help extrapolate aging test results to different thermal environments. Cell lifetime is evaluated qualitatively, considering simply the average calendar and cycle life across a range of conditions, as well as quantitatively, using statistical modeling and machine-learning methods to identify predictive aging models from the accelerated aging data. These predictive aging models are then used to investigate cell sensitivities to stressors, such as cycling temperature, voltage window, and C-rate, as well as to predict cell lifetime in various stationary storage applications. Results from this work show that cell lifetime and sensitivity to aging conditions varies substantially across commercial cells, necessitating testing for specific cell formats to make quantitative lifetime predictions. That being said, all commercial cells tested here are predicted to reach at least 10-year lifetimes for stationary storage applications. Based on the aging test results and modeling, some cells are expected to be relatively insensitive to temperature and use-case, making them suited for simple use cases with little or no thermal management and simple controls, while the lifetime of other cells could be extended to 20+ years if operated with thermal management and degradation-aware controls.

battery↗

Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuisance Odors: Is there a Concern - 12340

Nuisance odors are generally thought of as just being annoying or unpleasant and not causing any physiological harm to our internal organs or other biologic systems. Yet during an excavation of buried animal remains, field workers experienced a multitude of symptoms that are associated with exposures to toxic materials. An examination of the decomposition process revealed that there is a potential off-gassing of a number of common, yet harmful chemicals including ammonia, mercaptans, hydrogen sulfide, butyric acid and phenol. In addition, other compounds, that have limited information such as established health data and occupational exposure limits, were also potential contaminants-of-concern. While a variety of monitoring and sampling techniques were used to assess worker exposures, all results indicated non-detectable airborne concentrations. Nevertheless, workers were experiencing such symptoms as nausea and headaches. As such, protective measures were necessary for field personnel to continue work while having confidence that the project was instituting sincere steps to ensure their health and safety. Researching the possible reasons for the causes of workers exhibiting adverse health effects from nuisance odors revealed that such exposures initiate electrochemical pathways, starting from the olfactory bulb to the brain, followed by a transfer of information to such biologic systems as the hypothalamus and pituitary gland. These systems, in turn, secrete hormones that cause a number of involuntary reactions; many of which are observed as typical adverse health effects, when in fact, they are merely reactions caused by the brain's memory; most likely created from previous experiences to unpleasant odors. The concern then focuses of how the Occupational Safety and Health community shall respond to such workplace exposures. Future work in this area may need to focus on the viability of current occupational exposure limits and the possibility of revising these standards. Another area of consideration would be whether nuisance odors will need separate and distinct criteria with regards to hazard identification and control. While evidence suggests that odorants do not cause direct toxicological effects to the various biologic systems, they can be influential by initiating symptoms that are associated with known toxins. The difference between the classic toxic systemic reactions and those initiated by nuisance odors can be summarized as one causing a dysfunction of a target organ or system as opposed to triggering a message to the brain which causes a physical reaction. While strong odors may exist at HAZWOPER work sites, their particular risk of pathogenic disease has yet to be established. This leaves many unanswered questions; the most obvious being, 'can an odorous chemical that can result in headaches, nausea, changes in blood pressure, body temperature, etc., be considered a toxin even if biological systems remain unaffected and sampling/monitoring protocol negative stimuli, thereby causing symptomatic experiences; will such disciplines as psychology need to be considered as part of the expertise within the field a environmental and occupational health? In the classic text, 'The Fundamentals of Industrial Hygiene' industrial hygiene has been defined as 'that science and art devoted to the anticipation, recognition, evaluation, and control of those environmental factors or stressors arising in or from the workplace that may cause sickness, impaired health and well-being, or significant discomfort among workers or among the citizens of the community'. Based on this definition, it is indeed the responsibility of the occupational health professional to move forward and to provide an effective program to 'anticipate, recognize, evaluate, and control' such airborne contaminants that may not be adequately controlled based on current knowledge and technology. The question is, 'Is the industrial hygiene community equipped to carry out this responsibility?' 'Are new assessment methods and tools necessary? Are alternate exposure limits needed and can they be adequately implemented? As more of the non-traditional health hazards become recognized, it appears that it shall be essential for more sophisticated methods to be part of the standard practice used to assess human health. Whether that means more sensitive equipment that has greater detection capabilities, or the development of new technologies designed specifically for these hazards, at present can only be left to speculation. While the occupational health community may wrestle with these questions, the responsibility of the safety and health community must maintain its diligence. As such, persons within the discipline of environmental and occupational health must continue to communicate the hazards and controls to the work force. Through such efforts, the workforce shall become engaged in the process of hazard identification, assessment and control, which, in turn, will create a greater appreciation and acceptance for field assessment methods as well as the processes by which workplace controls are designed to protect them. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗