Supersonic Gas Injector for Plasma Fueling in the National Spherical Torus Experiment

A supersonic gas injector (SGI) has been developed for fueling and diagnostic applications on the National Spherical Torus Experiment (NSTX). It is comprised of a graphite converging-diverging Laval nozzle and a commercial piezoelectric gas valve mounted on a movable probe at a low-field-side midplane port location. Also mounted on the probe is a diagnostic package: a Langmuir probe, two thermocouples, and five pick-up coils for measuring toroidal, radial, vertical magnetic field components and magnetic fluctuations at the location of the SGI tip. The SGI flow rate is up to 33.25 Pa m 3 / (1.75 × 10 22 euterium particles/s), comparable to conventional NSTX gas injectors. The nozzle operates in a pulsed regime at room temperature and a reservoir gas pressure up to 665 kPa (5000 Torr). The deuterium jet Mach number of about 4 and the divergence half-angle of 5 to 25 deg have been measured in laboratory experiments simulating the NSTX environment. Reliable operation of the SGI and all mounted diagnostics at distances 0.01 to 0.20 m from the plasma separatrix has been demonstrated in NSTX experiments. The SGI has been used for fueling of ohmic and 2- to 4-MW neutral beam injection–heated L- and H-mode plasmas. Fueling efficiency in the range 0.1 to 0.3 has been obtained from the plasma electron inventory analysis. In conclusion, the SGI-fueling–based plasma discharge scenarios enabling better density control have been developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Hydraulics of Helium-Cooled Finger-Type Divertors at Higher Incident Heat Fluxes

Over the last decade, a number of studies at the Georgia Institute of Technology (GT) have evaluated the thermal hydraulics of the design of the helium-cooled modular divertor with multiple jets (HEMJ) originally developed at the Karlsruhe Institute of Technology. Using the GT helium loop, a test section of a single HEMJ finger heated by a radio-frequency (rf) induction heater was studied at near prototypical condition at pressures of ~10 MPa, maximum mass flow rates of 8 g/s, and maximum helium inlet temperatures Ti of 425°C. The area-averaged cooled surface temperature was estimated from embedded thermocouple measurements. This, together with the average incident heat flux q ‾ ′′ , was used to determine the average heat transfer coefficient and the corresponding Nusselt number N u ‾ over the cooled surface. The normalized pressure loss coefficient KL was determined from the pressure drop measured across the test section. The helium loop was modified last year by enclosing the test section and heater within an argon-filled stainless steel chamber to minimize oxidation of the tungsten-alloy test section. Initial results, when extrapolated to prototypical conditions, suggested that N u ‾ was about 20% higher than our previous results. However, the maximum heat flux for these results was less than 3 MW/m2 due to rf coupling with the steel chamber walls. The chamber was then recently upgraded to a glass–stainless steel enclosure with modified feedthroughs for the induction heater connections to minimize this coupling. With this upgrade, a maximum incident heat flux q ‾ ′′ = 8.1 MW/m 2 was achieved. This work presents experimental estimates and correlations for N u ‾ and K L at higher heat fluxes. These results provide greater confidence when estimating the maximum heat flux that can be accommodated by the HEMJ at fully prototypical conditions. Lastly, preliminary metrology results for the test section used to experimentally study the simplified flat design variant of the HEMJ are presented as part of an effort to resolve recently reported discrepancies between experimentally estimated and numerically simulated N u ‾ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CFD Simulation of Helium Flow Loop Test Section

A helium flow loop is being assembled at Oak Ridge National Laboratory to analyze heat transfer enhancement for systems such as blanket and divertor components. To efficiently identify optimum geometries for heat transfer enhancement in these applications, simulation work is performed to optimize test section designs that are built and tested in the helium flow loop that operates at 4 MPa and a mass flow rate of 100 g/s. Different ribbed geometries that examine rib shape, rib height, rib orientation, rib spacing, and three dimensional orientation are modeled and simulated in STAR-CCM+ to compare their ability to remove heat and mitigate pressure drop. Following the simulations, models are selected and manufactured for the helium flow loop tests. Simulations initially focus on a hydrodynamic study to determine the appropriate mesh and physics models and then add a heat flux to analyze the heat transfer abilities of the models. The simulations are run in steady state and use a Reynolds-averaged Navier-Stokes k-ε turbulence model. The helium is modeled as an ideal gas. The simulation explores models of geometries that enhance the heat transfer and decrease pressure drop with an overall goal of increasing fluid collision with the wall. Enhanced geometries are simulated to select appropriate designs for manufacturing, and preliminary experimental results are used to validate the simulations. Furthermore, the factors that are being analyzed in the comparison between the experimental and the simulated results include matching thermocouple temperatures, pressure drop, roughness, and fluid velocity.

42 ENGINEERING↗

Thermo-Mechanical Distortion of Tungsten-Coated Steel During High Heat Flux Testing Using Plasma Arc Lamps

An experimental setup and a test section were designed and fabricated for high heat flux testing (HHFT) of neutron-irradiated specimens using water-wall plasma arc lamps. Because of the radiological considerations and limitations of reactor irradiation, the size of the test articles was limited to disks less than 10 mm in diameter. The specimen was clamped onto an actively cooled block, and clamping allowed the insertion of several thermocouples on the back surface of the specimen through a copper (Cu) block. Five vacuum plasma sprayed tungsten (W)–coated F82H steel specimens were subjected to HHFT. Surface profilometry measurements, which were conducted after HHFT, revealed central bowing of the top W surface. This type of residual distortion occurred for all of the specimens, and the larger the specimens were, the larger was the distortion.In an attempt to understand specimen distortion and address the science questions related to the testing of subsize specimens during HHFT, a simplified thermo-mechanical model was developed. By using a measured temperature in the Cu as an isothermal boundary condition, the model eliminated the need for coupling cooling fluid flow models with stress models, greatly simplifying the analysis. The main variable in the proposed model is hC, i.e., the thermal contact conductance between the F82H and the Cu washer. Inelastic properties, including hardening properties, were considered for F82H steel and Cu. Numerical simulation results demonstrated a buildup of residual deformation during HHFT and a very complex state of stress and deformation during typical heat flux (HF) cycling. Additionally, hoop stress evolution during a high heat flux cycle reveals that F82H at an interface with W would be mainly in compression during HF application and experienced a transition to a tension state during cooldown. Also, specimen distortion evolves during each HF cycle, as the specimen bows downward during HF application and upward during the cooldown period between HF cycles. The final specimen distortion, i.e., upward bowing of the specimen center, was qualitatively predicted for hC values of 4000 to 5000 W/(m 2 ·K). This hC range of values, for which bulging is obtained, is at the lower spectrum of the range of values for hC, consistent with the low thermal contact conductance expected from the unpolished F82H surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ measurement of phase transformations and residual stress evolution during welding using spatially distributed fiber-optic strain sensors

Welding of high-strength steels can result in large tensile strains as the base metal and filler material cool from their molten state. To combat these large tensile strains, low-transformation-temperature (LTT) metal fillers have been proposed. These fillers undergo a martensitic phase transformation at a lower temperature which can ultimately reduce the tensile strain or can even introduce compressive strain adjacent to the weld metal. However, the process for optimizing the composition of the LTT material, as well as various weld parameters for each unique weld geometry, can be quite expensive, especially if the acceptance criterion requires using neutrons, x-ray beams, or destructive techniques to characterize residual stresses. This work describes a simple, low-cost method for quantifying residual stresses and phase transformations in situ during welding. Spatially distributed fiber-optic sensors were bonded to a cast iron plate, along with tack-welded thermocouples, to measure temperature and strain during multiple passes with LTT filler metals. Results show that the fiber-optic sensors can successfully resolve compressive strain adjacent to the weld region caused by the martensitic phase transformations in the LTT filler material.

47 OTHER INSTRUMENTATION↗

Error fields in the Wendelstein 7-X stellarator

The role of error fields in stellarators is explored in this work through simulations of, and experiments performed on, the Wendelstein 7-X (W7-X) stellarator. Previous experimental results, based on limiter plasmas in W7-X, suggest that error fields are small in the experiment based on limiter plasmas. In this work, we document results from the first divertor campaign on W7-X with a focus on error fields resonant with the edge island divertor structure. Measurements obtained using divertor thermocouples corroborate earlier limiter results that the error fields are small and correctable, requiring only 5% of the total rated current of the trim coil system. The effect of these error fields on magnetic geometry and topology are investigated using the flux surface measurement technique. The resulting divertor thermal load asymmetry is modeled via field line diffusion and compared to experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of heat flux measurement techniques during the DIII-D metal ring campaign

The heat fluxes expected in the ITER divertor raise concerns about the damage tolerances of tungsten, especially due to thermal transients caused by edge localized modes (ELMs) as well as frequent temperature cycling from high to low extremes. Thus we are motivated to understand the heat flux conditions that can cause not only enhanced erosion but also bulk thermo-mechanical damage to a tungsten divertor. For the metal ring campaign in DIII-D, tungsten-coated TZM tile inserts were installed making two toroidal arrays of metal tile inserts in the lower divertor. This study examines the deposited heat flux on these rings with embedded thermocouples (TCs) sampling at 10 kHz and compares them to Langmuir probe (LP) and infrared thermography (IRTV) heat flux measurements. We see agreement of the TC, LP, and IRTV data within 20% of the heat flux averaged over the entire discharge, and that all three diagnostics suggest parallel heat flux at the OSP location increases linearly with input heating power. The TC and LP heat flux time traces during the discharge trend together during large changes to the average heat flux. By subtracting the LP measured inter-ELM heat flux from TC data, using a rectangular ELM energy pulse shape, and taking the relative size and duration of each ELM from ${{D}}_{\alpha }$ measurements, we extract the ELM heat fluxes from TC data. This over-estimates the IRTV measured ELM heat fluxes by a factor of 1.9, and could be due to the simplicity of the TC heat flux model and the assumed ELM energy pulse shape. ELM heat fluxes deposited on the inserts are used to model tungsten erosion in this campaign. These TC ELM heat flux estimates are used in addition to IRTV, especially in cases where the IRTV view to the metal ring is obstructed. We observe that some metal inserts were deformed due to exposed leading edges. The thermal conditions on these inserts are investigated with the thermal modeling code ABAQUS using our heat flux measurements when these edges were exposed. We report on how the thermal cycling on the ends of the inserts caused this deformation.

42 ENGINEERING↗

Surface heat flux feedback controlled impurity seeding experiments with Alcator C-Mod's high-Z vertical target plate divertor: performance, limitations and implications for fusion power reactors

The Alcator C-Mod team has recently developed a feedback system to measure and control surface heat flux in real-time. The system uses real-time measurements of surface heat flux from surface thermocouples and a pulse-width modulated piezo valve to inject low-Z impurities (typically N 2 ) into the private flux region. It has been used in C-Mod to mitigate peak surface heat fluxes >40 MW m -2 down to <10 MW m -2 while maintaining excellent core confinement, H 98 > 1. While the system works quite well under relatively steady conditions, use of it during transients has revealed important limitations on feedback control of impurity seeding in conventional vertical target plate divertors. In some cases, the system is unable to avoid plasma reattachment to the divertor plate or the formation of a confinement-damaging x-point MARFE. This is due to the small operational window for mitigated heat flux in the parameters of incident plasma heat flux, plasma density, and impurity density as well as the relatively slow response of the impurity gas injection system compared to plasma transients. Given the severe consequences for failure of such a system to operate reliably in a reactor, there is substantial risk that the conventional vertical target plate divertor will not provide an adequately controllable system in reactor-class devices. Finally, these considerations motivate the need to develop passively stable, highly compliant divertor configurations and experimental facilities that can test such possible solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of error field correction coils on W7-X limiter loads

In the first campaign Wendelstein 7-X was operated with five poloidal graphite limiters installed stellarator symmetrically. In an ideal situation the power losses would be equally distributed between the limiters. The limiter shape was designed to smoothly distribute the heat flux over two strike lines. Vertically the strike lines are not uniform because of different connection lengths. In this paper it is demonstrated both numerically and experimentally that the heat flux distribution can be significantly changed by non-resonant $n=1$ perturbation field of the order of $10^{-4}$ . Numerical studies are performed with field line tracing. In experiments perturbation fields are excited with five error field trim coils. The limiters are diagnosed with infrared cameras, neutral gas pressure gauges, thermocouples and spectroscopic diagnostics. Experimental results are qualitatively consistent with the simulations. With a suitable choice of the phase and amplitude of the perturbation a more symmetric plasma-limiter interaction can be potentially achieved. Finally, these results are also of interest for the later W7-X divertor operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Space Nuclear Power Autonomous Control Algorithm and Control Element Test Bed

Nuclear thermal rockets are currently NASA’s preferred option for use in a manned mission to Mars in the 2040s. The communication delay between an Earth ground station and a spacecraft heading toward Mars can be up to 20 min. Therefore, controlling the nuclear rocket engine would require either a full-time reactor operator on the mission or an autonomous control system for the reactor. The latter idea of making space nuclear reactors fully autonomous has drawn more interest from stakeholders, but such an autonomous control system must be rigorously tested and validated before it is certified for human use. The cost of a full ground test for a space nuclear reactor is tremendous, so a nonnuclear mock reactor test bed was created to test and validate control elements and control algorithms for space nuclear reactors. The test bed consists of control element hardware that inputs physical measurement data into a reactor emulator to produce the reactor’s performance under steady-state, transient, and fault conditions. The control element hardware consists of six full-sized control drums equipped with servo drives and motors and is instrumented with optical encoders, resolvers, and torque sensors for drum movement characterization. In addition to the drums, a two-phase flow loop was designed and built to mimic the valves and turbomachinery associated with the propellant flow through a nuclear thermal rocket engine; components such as pressure sensors, flow meters, thermocouples, and tachometers are instrumented throughout the loop to characterize the fluid flow, valve, and turbomachinery behavior of the system. The data from the physical hardware (e.g., drum position, propellant flow rates) are input to a nuclear reactor simulator to determine the actual nuclear reactor parameters, and the data are sent back to a control algorithm to complete the control loop. The ability to conduct numerous tests of the control systems and autonomous algorithms can help validate the instrumentation and control aspects for a space nuclear reactor for every possible fault situation.

Wilson, Brandon↗

Development and Validation of Resistance-Capacitance Model for Phase Change Material Embedded in Porous Media

A simple and effective way to enhance PCM thermal conductivity is by embedding porous materials with high thermal conductivities. In this work, CFD was used to evaluate the melting of PCM embedded in metal foam supplied with constant heat flux. Good agreement between experimental and numerical results has been found with a mean PCM local temperature deviation of 1.62K and 2.97K in two locations. The CFD simulation time was 56 hours for 6.5 hours of flow time. A computationally efficient resistance capacitance-based model (RCM) was developed to improve simulation speed. The proposed RCM exhibited mean local temperature deviations of 1.86K and 2.96K when compared against the experimental data for two thermocouple positions, however, it was approximately 2.5x10 5 times faster than CFD. The charging time deviation was less than 1% compared to CFD, and no significant change in thermal energy stored was observed since the temperature differences were small enough to result in insignificant sensible heat deviation. A simulation cost-effectiveness index (CEI) considering accuracy and computational affordability was introduced; the CEI of the RCM solver is 10 3 times better compared to CFD for the prediction of local PCM temperature.

25 ENERGY STORAGE↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗