Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Numerical parameter optimizations of the Ignition and Growth model for a HMX plastic bonded explosive

We present here a novel method for optimizing parameters of the Ignition and Growth (I&G) reactive flow model for high explosives. The I&G model predicts the shock initiation response of explosives subjected to dynamic loading. However, calibrating the model is a time-consuming process because it has several parameters, typically requires multiple data sets, and there are no direct correlations between parameters and data. In this study, we couple a scalable optimization algorithm to simulations of shock initiation experiments in the multi-physics code ALE3D. We develop four I&G model parameter sets for the HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazocane)-based explosive LX-07 [90 wt. % HMX, 10 wt. % Viton A] based on minimizing the difference between calculations and measurements at the embedded pressure gauges in 1D gun shock experiments. Our study shows that a cost function based on both shock time of arrival and pressure pulse shape demonstrates the best agreement with experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Here, the 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multisite event discrimination for the majorana demonstrator

The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay($0\nu\beta\beta$) in 76 Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the $0\nu\beta\beta$ region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE , is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 ± 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228 Th calibration source data. In conclusion, the efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0\nu\beta\beta$ events, established using simulations.

59 ≤ A ≤ 89↗

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C3F8 scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c-2 and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c-2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility’s historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Qualification of 3-D Printed Mortar With Electrical Conductivity Measurements

Additive manufacturing (AM) or 3D printing of concrete allows for construction of arbitrary shape structures without a mold. Since reproducibility of 3D printed concrete is lower than that of conventional fabrication, each 3D printed structure should be monitored for proper curing. Conventional qualification of concrete is based on several tests, including destructive compressive strength measurements. Because a structure is 3-D printed layer-by-layer, the surfaces of AM concrete structures have significant surface roughness. This limits the applicability of conventional nondestructive testing methods. We investigated qualification of 3D printed mortar by monitoring curing with nondestructive electrical conductivity measurements. Bulk resistance of concrete was extracted from electrochemical impedance spectroscopy (EIS measurements made using custom flexible self-adhesive electrodes, which contour to rough surfaces. We show that bulk resistivity of concrete increases linearly with time. This allows for developing a calibration curve for compressive strength lookup from nondestructive electrical conductivity measurements. Conductivity measurements also allow for estimation of formation factor, which is an indicator of mortar permeability.

36 MATERIALS SCIENCE↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a {+-}2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as a detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lateral Gene Transfer Dynamics in the Ancient Bacterial Genus Streptomyces

Lateral gene transfer (LGT) profoundly shapes the evolution of bacterial lineages. LGT across disparate phylogenetic groups and genome content diversity between related organisms suggest a model of bacterial evolution that views LGT as rampant and promiscuous. It has even driven the argument that species concepts and tree-based phylogenetics cannot be applied to bacteria. For this paper, we show that acquisition and retention of genes through LGT are surprisingly rare in the ubiquitous and biomedically important bacterial genus Streptomyces . Using a molecular clock, we estimate that the Streptomyces bacteria are ~380 million years old, indicating that this bacterial genus is as ancient as land vertebrates. Calibrating LGT rate to this geologic time span, we find that on average only 10 genes per million years were acquired and subsequently maintained. Over that same time span, Streptomyces accumulated thousands of point mutations. By explicitly incorporating evolutionary timescale into our analyses, we provide a dramatically different view on the dynamics of LGT and its impact on bacterial evolution.Tree-based phylogenetics and the use of species as units of diversity lie at the foundation of modern biology. In bacteria, these pillars of evolutionary theory have been called into question due to the observation of thousands of lateral gene transfer (LGT) events within and between lineages. Here, we show that acquisition and retention of genes through LGT are exceedingly rare in the bacterial genus Streptomyces , with merely one gene acquired in Streptomyces lineages every 100,000 years. These findings stand in contrast to the current assumption of rampant genetic exchange, which has become the dominant hypothesis used to explain bacterial diversity. Our results support a more nuanced understanding of genetic exchange, with LGT impacting evolution over short timescales but playing a significant role over long timescales. Deeper understanding of LGT provides new insight into the evolutionary history of life on Earth, as the vast majority of this history is microbial.

59 BASIC BIOLOGICAL SCIENCES↗

CaliQEC: In-situ Qubit Calibration for Surface Code Quantum Error Correction

Quantum Error Correction (QEC) is essential for fault-tolerant, large-scale quantum computation. However, error drift in qubits undermines QEC performance during long computations, necessitating frequent calibration. Conventional calibration methods disrupt quantum states, requiring system downtime and rendering in situ calibration impractical. To address this challenge, we propose QECali, a novel framework that enables in situ calibration for surface codes. Our evaluation demonstrates that QECali introduces modest qubit overhead and negligible increases in execution time, offering the first practical solution for in situ calibration in surface code based quantum computation.

Fang, Xiang [University of California, Santa Barba↗

ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu

This study reports the accuracy and applications of an attenuated total reflectance–surface-enhanced infrared absorption spectroscopy (ATR–SEIRAS) technique to indirectly measure the interfacial pH of the electrolyte within 10 nm of the electrocatalyst surface. This technique can be used in situ to study aqueous electrochemical reactions with a calibration range from pH 1–13, time resolution down to 4 s, and an average 95% confidence interval of 14% that varies depending on the pH region (acidic, neutral, or basic). The method is applied here to electrochemical nitrate reduction at a copper cathode to demonstrate its capabilities, but is broadly applicable to any aqueous electrochemical reaction (such as hydrogen evolution, carbon dioxide reduction, or oxygen evolution) and the electrocatalyst may be any SEIRAS-active thin film (e.g., silver, gold, or copper). The time-resolved results show a dramatic increase in the interfacial pH from pH 2–7 in the first minute of operation during both constant current and pulsed current experiments where the bulk pH is unchanged. Attempts to control the pH polarization at the surface by altering the electrochemical operating conditions—lowering the current or increasing the pulse frequency—showed no significant change, demonstrating the challenge of controlling the interfacial pH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

Evaluation of the Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication.

Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.

99 GENERAL AND MISCELLANEOUS↗

Mixing and CP violation in the B$0\atop{s}$ meson system at CDF; Mélange et violation de CP dans le système des mésons B$0\atop{s}$ à CDF

The two analyses presented in the thesis, the B$0\atop{s}$ mixing analysis and the B$0\atop{s}$ → J/ψφ angular analysis, share most of the technical implementations and features. Thus, my choice was to pursue in parallel the common aspects of the analyses, avoiding, whenever possible, repetitions. Each Chapter is split in two parts, the first one dedicated to the B$0\atop{s}$ mixing analysis and the second one describing the angular analysis on the B$0\atop{s}$ → J/ψφ decay mode. They are organized as follows. In Chapter 1 we present the theoretical framework of the B$0\atop{s}$ neutral mesons system. After a general introduction on the Standard Model, we focus on the quantities which are relevant to the Δms measurement and the CP violation phenomena, underlying the details concerning the study of pseudo-scalar to vector vector decays, P → VV, which allow to carry out an angular analysis. A discussion on the implication of the measurements performed in the search of physics beyond the Standard Model is presented. The accelerator facilities and the CDF-II detector are reported in Chapter 2. While describing the detector, more emphasis is given to the components fundamental to perform B physics analyses at CDF. The Chapter 3 is focused on the reconstruction and selection of the data samples. The Chapter starts with a description of the on-line trigger requirements, according to the B$0\atop{s}$ sample considered, followed by the offline selection criteria implemented to reconstruct B$0\atop{s}$ semileptonic and hadronic decays, fully and partially reconstructed, for the B$0\atop{s}$ mixing analysis, as well as the B$0\atop{s}$ → J/ψφ decay mode for the angular analysis. The subsequent Chapter 4 is dedicated to the revision of the technical ingredients needed in the final analyses. The B$0\atop{s}$ mixing elements are firstly described. The methodology historically used in the oscillation searches, the 'amplitude scan', is here introduced together with the calibration of the proper-decay-time resolution and the flavor tagging algorithms, in particular a closer examination of the same-side tagger performances is given. The B$0\atop{s}$ → J/ψφ angular analysis elements description then follows, focusing on the performances and the eventual differences with respect to the B$0\atop{s}$ oscillation search. The final results of the analyses are obtained with the use of an un-binned likelihood fitting framework: Chapter 5 presents the general principles behind this methodology and a description of both the maximum likelihood fitters employed. Chapter 6 contains the conclusive results on the B$0\atop{s}$ analyses. They are presented in an historical fashion: the measurement of the B$0\atop{s}$ oscillation frequency is followed by the first flavor tagged ΔΓs and βs measurements. The impact and the constraints on the parameters of the flavor model is part of the discussion in the Chapter. As cross-check of the B$0\atop{s}$ angular analysis, the B$0\atop{s}$ → J/ψK*0 decay mode has been additionally studied. Its angular analysis shows a competitive sensitivity with the B factories in measuring the parameters which define the decay. Not only this contributes to enforce the reliability of the entire framework, but it constitutes an excellent result by itself. Thus, we devote the entire Chapter 7 to the sole discussion of the angular analysis of the B$0\atop{s}$ → J/ψK*0 decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MultiPEM Toolbox: User Manual [Rev. 2]

This document explains use of the Multi-Phenomenology Explosion Monitoring (Multi PEM) Toolbox, a collection of R scripts for estimating the unknown device parameters of a new event with uncertainty quantification. The methodology and application used for illustration in this user manual are fully documented in a Los Alamos National Laboratory technical report hereafter designated “WPA” for reference. Additional details on the application are found in a recent journal article. Two assessment types are available: rapid and complete. Rapid assessments are conducted in two stages, as described in Section 2. In the first stage, calibration data are used to estimate forward and error model parameters (WPA, §5.1) and (if relevant) errors-in-variables yield values for calibration sources (WPA, §3, Equation (3)). In the second stage, new event data are used to estimate the unknown new event device parameters (WPA, §5.2) with uncertainty quantification. Two options for treating the inferred first stage parameters in second stage Bayesian analysis are available: fixing them at their maximum likelihood estimate (default), or multiple imputation. Multiple imputation involves utilizing several posterior samples (imputations) of the first stage parameters as fixed values in the second stage posterior sampling of the new event device parameters. Second stage sampling is conducted across imputations in parallel to improve computational efficiency. This method produces improved uncertainty quantification of the new event device parameters compared with the default treatment of the first stage parameters, at the expense of additional computation. Complete assessments are conducted in a single stage, as described in Section 3. Calibration and (if relevant) new event data are used simultaneously to estimate all forward model, error model, and (if relevant) new event device parameters with uncertainty quantification on the latter. As the name suggests, rapid assessments generally run substantially faster than complete assessments (even with multiple imputation), because the results of first stage analysis can be stored and incorporated into estimating a relatively low-dimensional space of new event device parameters whenever relevant new event data becomes available. On the other hand, complete assessments must be run on the full set of model and device parameters with calibration and new event data every time the latter becomes available.

97 MATHEMATICS AND COMPUTING↗