At least 901 records · Page 50

In-flight gyro drift rate calibration on the Viking Orbiters

The drift rates of the attitude control gyros onboard the Viking Orbiters were calibrated several times during flight. The calibration was performed by engaging the gyro control of attitude for a six-hour period, recording the Viking Orbiter coordinates of the sun and the roll reference star as a function of time, and processing these data by a computer program. The computer program calculated drift rates for each data increment, and then smoothed the calculated rate versus the time function for all the data on the basis of a Gauss-Markov gyro-drift model. The effects of data noise were minimized by using a relatively long time constant in the Gauss-Markov model and by empirically determining a set of corrections for celestial inertial scale factor error differences. In this way the rms error of the data fit was lessened.

Breckenridge, W. G.↗

The simulated depth history of dust grains in the lunar regolith

Trajectories giving the individual depth variations of lunar dust grains with time are randomly generated by a Monte Carlo code, where the variables are the mass and speed distribution of meteorites at the lunar surface and the geometrical shape of impact craters. A statistical analysis of a great number of such trajectories is then used to define the 'average' depth history of lunar dust grains for two grain radii: 1 and 50 microns. This yields: (1) estimates for time constants involved during the dynamic evolution of the regolith, (2) a model for the layering of the regolith, and (3) a better understanding of the basic dust-grain mechanisms responsible for the formation of the most mature lunar soil samples. The validity of various soil models proposed for the dynamic evolution of the regolith is discussed in terms of experimental constraints on the models.

Duraud, J. P.↗

On-line parameter estimation using a high sensitivity estimator

An on-line parameter identification method is presented. The method is based on a recursive formulation of the maximum likelihood method, with a significant modification on the gains of the state estimator. In the conventional maximum likelihood method, the Kalman gains are used in the state estimator. This produces unbiased, minimum variance parameter estimates in the presence of process noise and measurement noise, but it also slows the convergence rate when the identification is done on-line. Here we suggest choosing the gains to maximize a measure of the sensitivities of the state estimates to parameter variations. One such criterion is to minimize the trace of the inverse information matrix. This increases the convergence rate significantly. After one or two time constants, the gains are switched to the Kalman values to assure unbiased, minimum-variance estimates. The state estimate will initially be nonoptimal, and may not be adequate for control purposes. In this case, a parallel Kalman filter which uses the identifier's parameter estimates can be used. This method is applied here for the identification of a simple first-order system, and for the identification of short-period stability derivatives of an F-8 aircraft from simulated data.

Mishne, D.↗

Radiometer at a frequency of 108-120 GHz for study of the earth's atmosphere

Calculated and experimental design and operating characteristics of a 108-120 GHz superheterodyne radiometer with intermediate frequency modulation and a second harmonic frequency converter are presented and discussed. With a 1 sec time constant, the radiometer fluctuation sensitivity threshold is 1 K, without degradation in 2 hours of operation. Graphs of frequency variations, calibration, conversion loss, rectified current, fixed bias voltage, and contact needle impedance are included.

Bordonskiy, G. S.↗

Evaluation of kinesthetic-tactual displays using a critical tracking task

The study sought to investigate the feasibility of applying the critical tracking task paradigm to the evaluation of kinesthetic-tactual displays. Four subjects attempted to control a first-order unstable system with a continuously decreasing time constant by using either visual or tactual unidimensional displays. Display aiding was introduced in both modalities in the form of velocity quickening. Visual tracking performance was better than tactual tracking, and velocity aiding improved the critical tracking scores for visual and tactual tracking about equally. The results suggest that the critical task methodology holds considerable promise for evaluating kinesthetic-tactual displays.

Jagacinski, R. J.↗

Analysis of the passive stabilization of the long duration exposure facility

The nominal Long Duration Exposure Facility (LDEF) configurations and the anticipated orbit parameters are presented. A linear steady state analysis was performed using these parameters. The effects of orbit eccentricity, solar pressure, aerodynamic pressure, magnetic dipole, and the magnetically anchored rate damper were evaluated to determine the configuration sensitivity to variations in these parameters. The worst case conditions for steady state errors were identified, and the performance capability calculated. Garber instability bounds were evaluated for the range of configuration and damping coefficients under consideration. The transient damping capabilities of the damper were examined, and the time constant as a function of damping coefficient and spacecraft moment of inertia determined. The capture capabilities of the damper were calculated, and the results combined with steady state, transient, and Garber instability analyses to select damper design parameters.

Siegel, S. H.↗

INTELSAT 4 in orbit liquid slosh tests and problems in the theoretical analysis of the data

The destabilizing effect of the liquid on attitude nutation stability was determined from an extensive series of inorbit tests. The liquid slosh driving frequency ratio (rotor nutation frequency/rotor spin rate) was varied over the range of 0.58 to 0.70 for the tests by rotating the spacecraft antenna platform at different rates in inertial space. A rotor mounted accelerometer sensed the spacecraft nutation. The observed time constant for the nutation angle increase or decrease was corrected for the stabilizing contribution of the platform mounted pendulum dampers to yield the net destabilizing dedamping contribution from the liquid slosh. The in orbit tests show two unexpected maxima in the dedamping contribution at driving frequency ratios that vary with the propellant loading. The rotor nutation frequency at the maxima was about one-third of the lowest mode liquid slosh frequency given by ground test data for unspun tanks, and thus did not correspond to a simple resonance of the liquid. Ground tests with spinning systems produced the same maxima, but the phenomenon is not yet understood.

Slabinski, V. J.↗

Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

Source record↗

Indoor test for thermal performance of the GE TC-100 liquid solar collector eight- and ten-tube configuration

The thermal performance of a liquid solar collector was tested in eight- and ten-tube configurations under simulated conditions. A time constant test and an incident angle modifier test were also conducted to determine the transient and incident angle effects on the collector. Performance loss with accessory covers is demonstrated. The gross collector area is about 17.4 ft sq without manifold and 19.1 ft sq with manifold. The collector weight is approximately 60 pounds empty and 75 pounds with manifold.

Source record↗

Infrared detector performance in the Shuttle Infrared Telescope Facility /SIRTF/

The limitations imposed on infrared detectors for SIRTF are quite different from those imposed on ground-based, balloon-borne, or aircraft-borne systems. The paper examines the limitations and provides performance predictions corresponding to SIRTF conditions. Detector parameters typical of an infrared camera are used. The detector size is taken to be of the order of the diffraction-limited spot, frequency response is taken to correspond to a fraction of a second or less time constant, and spectral definition is provided by multilayer dielectric filters, inductive or capacitive grids, intrinsic absorption, or a combination of these. A nominal 10-micron bandwidth is assumed. The discussion covers atmospheric absorption and emission, zodiacal dust radiance, Shuttle contaminants, telescope self-emission, charged particle radiation, clear environment detector performance, and trapped radiation effects. It is concluded that the SIRTF design and operating conditions will allow current and near-term state-of-the-art detectors to reach their performance limits with SIRTF at a temperature of 10-12 K.

Mccarthy, S. G.↗

Measurement in multiphase reacting flows

A survey is presented of diagnostic techniques and measurements made in multiphase reacting flows. The special problems encountered by the presence of liquid droplets, soot and solid particles in high temperature chemically reacting turbulent environments are outlined. The principal measurement techniques that have been tested in spray flames are spark photography, laser anemometry, thermocouples and suction probes. Spark photography provides measurement of drop size, drop size distribution, drop velocity, and angle of flight. Photographs are analysed automatically by image analysers. Photographic techniques are reliable, inexpensive and proved. Laser anemometers have been developed for simultaneous measurement of velocity and size of individual particles in sprays under conditions of vaporization and combustion. Particle/gas velocity differentials, particle Reynolds numbers, local drag coefficients and direct measurement of vaporization rates can be made by laser anemometry. Gas temperature in sprays is determined by direct in situ measurement of time constants immediately prior to measurement with compensation and signal analysis by micro-processors. Gas concentration is measured by suction probes and gas phase chromatography. Measurements of particle size, particle velocity, gas temperature, and gas concentration made in airblast and pressure atomised liquid spray flames are presented.

Chigier, N. A.↗

Ammonia photolysis and the greenhouse effect in the primordial atmosphere of the earth

Photochemical calculations indicate that in the prebiotic atmosphere of earth ammonia would have been irreversibly converted to N2 in less than 40 years if the ammonia surface mixing ratio were no more than 0.0001. However, if a continuous outgassing of ammonia were maintained, radiative-equilibrium calculations indicate that a surface mixing ratio of ammonia of 0.0001 or greater would provide a sufficient greenhouse effect to keep the surface temperature above freezing. With a 0.0001 mixing ratio of ammonia, 60% to 70% of the present-day solar luminosity would be adequate to maintain surface temperatures above freezing. A lower limit to the time constant for accumulation of an amount of nitrogen equivalent to the present day value is 10 my if the outgassing were such as to provide a continuous surface mixing ratio of ammonia of at least 0.00001.

Kuhn, W. R.↗

A comparison of kinesthetic-tactual and visual displays via a critical tracking task

The feasibility of using the critical tracking task to evaluate kinesthetic-tactual displays was examined. The test subjects were asked to control a first-order unstable system with a continuously decreasing time constant by using either visual or tactual unidimensional displays. The results indicate that the critical tracking task is both a feasible and a reliable methodology for assessing tactual tracking. Further, that the critical tracking methodology is as sensitive and valid a measure of tactual tracking as visual tracking is demonstrated by the approximately equal effects of quickening for the tactual and visual displays.

Jagacinski, R. J.↗

Spatially resolved infrared observations of Saturn. III - 10- and 20-micron disk scans at B prime = -11.8 deg

Disk scans of Saturn at 10 and 20 microns were obtained when the Saturnicentric solar declination B prime was -11.8 deg. The scans show little change from scans obtained when B prime was -16.3 deg. This could result from the long radiative time constant of the Saturnian atmosphere. The observations at 20 microns, in the H2 continuum, show positively that the temperature inversion at the south pole has a higher temperature than at any other point on the disk. In addition, the 12.1- and 20-micron scans indicate that the temperature of the inversion region is higher at the equator compared to the temperate zone. The data also suggest that enhanced 20-micron emission is correlated with the strength of the ultraviolet absorption.

Tokunaga, A. T.↗

Continuous control of phase-locked-loop bandwidth

Tracking loop filter with continuous bandwidth control smooths transition from wide to narrow band. Circuit was designed for Space Shuttle where bandwidth varied between 320 Hz for acquisition and 20 Hz for tracking. Field-effect transitor (FET) acts as voltage controlled variable resistance, changing time constant of filter between phase detector and voltage-controlled oscillator in phase-locked loop.

Motal, G. W.↗

Indoor tests of the concentric-tube solar collector

Report describes performance tests on 12-tube, liquid-filled collector. Thermal efficiency, change in efficiency with sun position, and time constant for temperature drop after solar flux is cut are described.

Source record↗

Evacuated-tube solar collector--performance evaluation

Report gives thermal performance test procedures and results for commercially produced, water-filled, 8-tube collectors. Tests include efficiency, time constant for temperature drop after solar flux is cut, change in efficiency as function of sun angle, and test to see if tubes break when filled with hot water.

Source record↗

Glycol/water evacuated-tube solar collector

Report describes performance of 8 tube and 10 tube commercially produced solar collectors. Tests include thermal efficiency, time constant for temperature drop after solar flux is cut, change in efficiency with Sun angle, and temperature rise if circulation is stopped.

Source record↗