Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Multidisciplinary Design Optimization (MDO) Methods: Their Synergy with Computer Technology in Design Process

The paper identifies speed, agility, human interface, generation of sensitivity information, task decomposition, and data transmission (including storage) as important attributes for a computer environment to have in order to support engineering design effectively. It is argued that when examined in terms of these attributes the presently available environment can be shown to be inadequate a radical improvement is needed, and it may be achieved by combining new methods that have recently emerged from multidisciplinary design optimization (MDO) with massively parallel processing computer technology. The caveat is that, for successful use of that technology in engineering computing, new paradigms for computing will have to be developed - specifically, innovative algorithms that are intrinsically parallel so that their performance scales up linearly with the number of processors. It may be speculated that the idea of simulating a complex behavior by interaction of a large number of very simple models may be an inspiration for the above algorithms, the cellular automata are an example. Because of the long lead time needed to develop and mature new paradigms, development should be now, even though the widespread availability of massively parallel processing is still a few years away.

Sobieszczanski-Sobieski, Jaroslaw↗

An Efficient Power Flexibility Aggregation Framework via Coordinate Transformation and Chebyshev Centering Optimization

The large-scale integration of distributed energy resources (DERs) converts the role of a distribution system from a customer to a prosumer. In this context, the controllable DERs are expected to provide capacity support for the transmission system, which can be considered as power flexibility aggregation. Specifically, it is a process of controlling the power output of DERs to fulfill the desired capacity or flexibility. However, the power output of DERs as control variables is redundant. That is, a power flexibility command can be realized by multiple dispatch alternatives, which may hinder efficient design of control rules and flexibility evaluation schemes. Therefore, this paper introduces a conception of the artificial power flexibility controller to avoid the redundancy issue, which is a converted control variable after reconstructing the DER power region. Through this reconstruction, the DERs can be indirectly controlled by the proposed artificial power flexibility controller. In addition, a Chebyshev centering optimization model is developed to approximate the power flexibility region. At last, the proposed method is verified on an artificially-designed network with multiple DERs.

Chebyshev centering optimization↗

Wireless Transmission of Monitoring Data out of an Underground Repository: Results of Field Demonstrations Performed at the HADES Underground Laboratory - 13589

As part of the European 7. framework project MoDeRn, Nuclear Research and Consultancy Group (NRG) performed experiments in order to demonstrate the feasibility of wireless data transmission through the subsurface over large distances by low frequency magnetic fields in the framework of the geological disposal of radioactive waste. The main objective of NRG's contribution is to characterize and optimize the energy use of this technique within the specific context of post-closure monitoring of a repository. For that, measurements have been performed in the HADES Underground Research Laboratory (URL) located at Mol, Belgium, at 225 m depth. The experimental set-up utilizes a loop antenna for the transmitter that has been matched to the existing infrastructure of the HADES. Between 2010 and 2012 NRG carried out several experiments at the HADES URL in order to test the technical set-up and to characterize the propagation behavior of the geological medium and the local background noise pattern. Transmission channels have been identified and data transmission has been demonstrated at several frequencies, with data rates up to 10 bit/s and bit error rates <1%. A mathematical model description that includes the most relevant characteristics of the transmitter, transmission path, and receiver has been developed and applied to analyze possible options to optimize the set-up. With respect to the energy-efficiency, results so far have shown that data transmission over larger distances through the subsurface is a feasible option. To support the conclusions on the energy need per bit of transmitted data, additional experiments are foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Arctic Deployment of a Fully Integrated Self-Powered Drifting Buoy Harvesting Wave Energy via a Triboelectric Nanogenerator

The Arctic Ocean remains one of the most poorly sampled regions on Earth, where improved in situ environmental monitoring is vital for advancing oceanographic and atmospheric studies. However, data collection efforts are constrained by the short operational lifespans and high costs of conventional systems. Drifting buoys powered by pendulum-driven wave energy harvesters offer a cost-effective alternative, yet earlier designs have neither been optimized for real-world wave conditions nor validated in the Arctic. In this study, we develop a self-powered drifting buoy that integrates a pendulum-driven triboelectric nanogenerator (TENG) system with a mechanical motion rectifier, a high-gear-ratio transmission, and power management circuits. Through coupled buoy–pendulum dynamic simulations and laboratory testing using a motion simulator, we identify an optimal pendulum mass of 1.6 kg (12.7% of total buoy weight) that maximizes energy output while maintaining buoy stability. Laboratory experiments achieved average power outputs of 12.7 mW under Arctic-like wave and temperature conditions. The system was successfully deployed in the Bering Sea, where it generated 11 J of energy in 3.1 m waves, marking the first Arctic deployment of a TENG-based drifting buoy for sea surface temperature monitoring. This work establishes a cost-effective framework for designing self-powered Arctic monitoring platforms and advances the feasibility of long-term environmental observations in real Arctic waters.

marine enerby↗

A method for modeling discontinuities in a microwave coaxial transmission line

A method for modeling discontinuities in a coaxial transmission line is presented. The methodology involves the use of a nonlinear least-squares fit program to optimize the fit between theoretical data (from the model) and experimental data. When this method was applied to modeling discontinuities in a slightly damaged Galileo spacecraft S-band (2.295-GHz) antenna cable, excellent agreement between theory and experiment was obtained over a frequency range of 1.70-2.85 GHz. The same technique can be applied for diagnostics and locating unknown discontinuities in other types of microwave transmission lines, such as rectangular, circular, and beam waveguides.

Otoshi, T. Y.↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of microplasma discharge in a spark gap for high repetitive switching

The electrical breakdown in a spark gap for repetitive switching has been a long research interest. For this purpose, microplasma discharge is implemented in the spark gap which is further integrated inside a coaxial transmission line. This work addresses important physical properties and insights of the microplasma discharge, to be optimized, such as plasma generation in a spark channel, dielectric recovery process, and residual plasma in the postspark discharge period. Although understanding the microplasma discharge is the primary goal, considerable attention has been focused on an external circuit scheme to drive the discharge system at a high repetition rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical Cable Design for Urban Air Mobility Aircraft

Urban Air Mobility (UAM) describes a new type of aviation focused on efficient flight within urban areas for moving people and goods. There are many different configurations of UAM vehicles, but they generally use an electric motor driving a propeller or ducted fan powered by batteries or a hybrid electric power generation system. Transmission cables are used to move energy from the storage or generation system to the electric motors. Though terrestrial power transmission cables are well established technology, aviation applications bring a whole host of new design challenges that are not typical considerations in terrestrial applications. Aircraft power transmission cable designs must compromise between resistance-per-length, weight-per-length, volume constraints, and other essential qualities. In this paper we use a multidisciplinary design optimization to explore the sensitivity of these qualities to a representative tiltwing turboelectric UAM aircraft concept. This is performed by coupling propulsion and thermal models for a given mission criteria. Results presented indicate that decreasing cable weight at the expense of increasing cable volume or cooling demand is effective at minimizing maximum takeoff weight (MTO). These findings indicate that subsystem designers should update their modeling approach in order to contribute to system-level optimality for highly-coupled novel aircraft. Mobility (UAM) vehicles have the potential to change urban and intra-urban transport in new and interesting ways. In a series of two papers Johnson et al.1 and Silva et al.2 presented four reference vehicle configurations that could service different niches in the UAM aviation category. Of those, this paper focuses on the Vertical Take-off and Landing (VTOL) tiltwing configuration shown in Figure 1. This configuration uses a turboelectric power system, feeding power from a turbo-generator through a system of transmission cables to four motors spinning large propellers on the wings. Previous work on electric cable subsystems leaves much yet to be explored, especially in the realm of subsystem coupling. Several aircraft optimization studies1, 3, 4 only considered aircraft electrical cable weight and ignored thermal effects. Electric and hybrid-electric aircraft studies by Mueller et al.5 and Hoelzen et al.6 selected a cable material but did not investigate alternative materials. Advanced cable materials have been examined by a number of authors: Alvarenga7 examined carbon nanotube (CNT) conductors for low-power applications. De Groh8, 9 examined CNT conductors for motor winding applications. Behabtu et al.,10 and Zhao et al.11 examined CNT conductors for a general applications. There were some studies that examined the thermal effects of cables but they did not allow the cable material to change; El-Kady12 optimized ground-cable insulation and cooling subject constraints. Vratny13 selected cable material based on vehicle power demand, and required resulting cable heat to be dissipated by the Thermal Management System (TMS). None of these previous studies allowed for the selection of the cable material based on a system level optimization goal. Instead, they focused on sub-system optimality such as minimum weight, which comes at the expense of incurring additional costs for other subsystems. Dama14 selected overhead transmission line materials using a weighting function and thermal constraints. However, that work was not coupled with any aircraft subsystems like a TMS. The traditional aircraft design approach, which relies on assembling groups of optimal subsystems, breaks down when considering novel aircraft concepts like the tiltwing vehicle. In a large part, this is because novel concepts have a much higher degree of interaction or coupling between subsystems. For example, when a cable creates heat, this heat needs to be dissipated by the TMS, which needs power supplied by the turbine, and delivering the power creates more heat. The cable, the TMS, and the turbine are all coupled. A change to one subsystem will affect all the other subsystems, much to the consternation of subsystem design experts. Multidisciplinary optimization is the design approach that can address these challenges. However, to fully take advantage of this, we must change the way we think about subsystem design. Specifically, we must move away from point design, and focus on creating solution spaces. The work presented in this paper uses the multidisciplinary optimization approach with aircraft level models to study the system-level sensitivity of cable traits: weight-per-length and resistance-per-length. Additionally, we examined the effects of vehicle imposed volume constraints on these traits. This is useful for three purposes: (1) to demonstrate a framework that can perform a coupled analysis between the aircraft thermal and propulsion systems, (2) to provide a method by which future cable designs can be evaluated against each other given a system-level design goal, (3) to provide insight into what cable properties may be promising for future research. This last element is explored given the caveat that the models contained in this analysis do not represent high-fidelity systems. Thus, while we can demonstrate coupling in between systems, the exact system-level sensitivity to a given parameter may change if a subsystem model or the assumptions governing that model change. The organization of this paper is as follows, in Sec II we outline a method to combine the VTOL vehicle design and cable information in order to produce cables sensitivity studies. Results analysis and discussion are contained in Sec III. Conclusions are presented in Sec IV.

Aretskin-Hariton, Eliot D.↗

Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating

Purpose: To provide a rapid method to reduce the radiofrequency (RF) E-field coupling and consequent heating in long conductors in an interventional MRI (iMRI) setup. Methods: A driving function for device heating (W) was defined as the integration of the E-field along the direction of the wire and calculated through a quasistatic approximation. Based on this function, the phases of four independently controlled transmit channels were dynamically changed in a 1.5 T MRI scanner. During the different excitation configurations, the RF induced heating in a nitinol wire immersed in a saline phantom was measured by fiber-optic temperature sensing. Additionally, a minimization of W as a function of phase and amplitude values of the different channels and constrained by the homogeneity of the RF excitation field (B{sub 1}) over a region of interest was proposed and its results tested on the benchtop. To analyze the validity of the proposed method, using a model of the array and phantom setup tested in the scanner, RF fields and SAR maps were calculated through finite-difference time-domain (FDTD) simulations. In addition to phantom experiments, RF induced heating of an active guidewire inserted in a swine was also evaluated. Results: In the phantom experiment, heating at the tip of the device was reduced by 92% when replacing the body coil by an optimized parallel transmit excitation with same nominal flip angle. In the benchtop, up to 90% heating reduction was measured when implementing the constrained minimization algorithm with the additional degree of freedom given by independent amplitude control. The computation of the optimum phase and amplitude values was executed in just 12 s using a standard CPU. The results of the FDTD simulations showed similar trend of the local SAR at the tip of the wire and measured temperature as well as to a quadratic function of W, confirming the validity of the quasistatic approach for the presented problem at 64 MHz. Imaging and heating reduction of the guidewire were successfully performed in vivo with the proposed hardware and phase control. Conclusions: Phantom and in vivo data demonstrated that additional degrees of freedom in a parallel transmission system can be used to control RF induced heating in long conductors. A novel constrained optimization approach to reduce device heating was also presented that can be run in just few seconds and therefore could be added to an iMRI protocol to improve RF safety.

60 APPLIED LIFE SCIENCES↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I -- National Study

The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Thanks to advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India's RE targets and identify actions that may be favorable for integration. Our primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU's anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD $920 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment - from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India's 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanocluster production for solar cell applications

This research focuses on the fabrication and characterization of silver (Ag) and silicon (Si) nanoclusters that might be used for solar cell applications. Silver and silicon nanoclusters have been synthesized by means of dc magnetron sputtering and inert gas condensation inside an ultra-high vacuum compatible system. We have found that nanocluster size distributions can be tuned by various source parameters, such as the sputtering discharge power, flow rate of argon inert gas, and aggregation length. Quadrupole mass filter and transmission electron microscopy were used to evaluate the size distribution of Ag and Si nanoclusters. Ag nanoclusters with average size in the range of 3.6–8.3 nm were synthesized (herein size refers to the nanocluster diameter), whereas Si nanoclusters' average size was controlled to range between 2.9 and 7.4 nm by controlling the source parameters. This work illustrates the ability of controlling the Si and Ag nanoclusters' sizes by proper optimization of the operation conditions. By controlling nanoclusters' sizes, one can alter their surface properties to suit the need to enhance solar cell efficiency. Herein, Ag nanoclusters were deposited on commercial polycrystalline solar cells. Short circuit current (I{sub SC}), open circuit voltage (V{sub OC}), fill factor, and efficiency (η) were obtained under light source with an intensity of 30 mW/cm{sup 2}. A 22.7% enhancement in solar cell efficiency could be measured after deposition of Ag nanoclusters, which demonstrates that Ag nanoclusters generated in this work are useful to enhance solar cell efficiency.

36 MATERIALS SCIENCE↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India’s Electric Grid, Vol. 1. National Study

The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Using advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India’s RE targets and identify actions that may be favorable for integration. Our primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (Berkeley Lab), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU’s anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD 980 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment—from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India’s 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable algorithms for power system analysis in the presence of data uncertainties

A robust and reliable power flow analysis represents an essential requirement for many power systems applications as far as network optimization, voltage control, state estimation, and service restoration are concerned. The most common power flow approach, referred to here as a deterministic power flow (PLF), requires precise or 'crisp' values chosen by the analyst for each input variable. The solution provides precise network voltages and flows through each line. The specified values rest upon assumptions about the operating condition derived from historical measurements or predictions about future conditions and thus, cannot be considered accurate. Even in the case where the inputs are based on measurements, inaccuracies arise from time-skew problems, three-phase unbalance, static modeling approximations of dynamic components (e.g., transformer tap changers), variations in line parameters, and so on. The advent of deregulation and competitive power markets will only exacerbate this problem as well-known generation patterns change, loading becomes less predictable and the transmission paths grow more diverse. Conventional methodologies proposed in literature address tolerance analysis of power flow solution by means of detailed probabilistic methods, accounting for the variability and stochastic nature of the input data, and sampling based approaches. In particular uncertainty propagation using sampling based methods, such as the Monte Carlo, requires several model runs that sample various combinations of input values. Since the number of model runs can sometimes be very large, the required computer resources can sometimes be prohibitively expensive resulting in substantial computational demands. As far as probabilistic methods are concerned, they represent a useful tool, especially for planning studies, but, as evidenced by the many discussions reported in literature, they could reveal some shortcomings principally arising from: (1) the non-normal distribution and the statistical dependence of the input data; and (2) the difficulty arising in accurately identifying probability distributions for some input data, such as the power generated by wind or photovoltaic generators. All these could result in time consuming computations with several limitations in practical applications especially in power flow analysis of complex power networks. In order to try and overcome some of these limitations, obtaining thereby comprehensive power flow solution tolerance analysis at adequate computational costs, self validated computation could play a crucial role. Armed with such a vision, this chapter will analyze two advanced techniques for power flow analysis in the presence of data uncertainty namely the boundary power flow and the affine arithmetic power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolytic Renewable Fuel Production Optimal Operation Investigation - H2@Scale: Cooperative Research and Development Final Report, CRADA Number CRD-19-00818

This work explored the optimal design and operation of electrolytic hydrogen production from renewable power. While there are many financial incentives for renewable hydrogen, this work investigated the effects of Low Carbon Fuel Standards (LCFS) on the hydrogen breakeven cost. To this end, this project developed optimized operational strategies for electrolytic hydrogen facilities in the California. Four specific model projects were used as the basis for the analysis. Three model projects will be located in California and one in Texas or the Midwest to be determined during the project. All projects include interconnection to the natural gas grid as a method of transport for the product fuel and the hydrogen cases will also consider alternative modes of transport. The operational optimization will maximize project return through fuel production and grid services based on future scenarios for the value of each. The effort will rely on modeling tools developed by NREL and the UCI for grid modeling as well as the integrated resource planning tool (IRP), RESOLVE, which is the official IRP tool used by the California Public Utility Commission (CPUC). The development of this project can help to inform future hydrogen deployment, policy and regulation makers, research and development decisions, and private and public investment.

08 HYDROGEN↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear-Reaction-Based Radiation Source For Explosives-And SNM-Detection In Massive Cargo

An automatic, nuclear-reaction-based, few-view transmission radiography method and system concept is presented, that will simultaneously detect small, operationally-relevant quantities of chemical explosives and special nuclear materials (SNM) in objects up to the size of LD-3 aviation containers. Detection of all threat materials is performed via the {sup 11}B(d,n+{gamma}) reaction on thick, isotopically-enriched targets; SNM are primarily detected via Dual Discrete-Energy Radiography (DDER), using 15.11 MeV and 4.43 MeV {sup 12}C{gamma}-rays, whereas explosives are primarily detected via Fast Neutron Resonance Radiography (FNRR), employing the broad-energy neutron spectra produced in a thick {sup 11}B-target. To achieve a reasonable throughput of {approx}20 containers per hour, ns-pulsed deuteron beam of the order of 0.5 mA intensity at energies of 5-7 MeV is required. As a first step towards optimizing parameters and sensitivities of an operational system, the 0 deg. spectra and yields of both {gamma}-rays and neutrons in this reaction have been measured up to E{sub d} = 6.65 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance assessment of 3D printed multi-material energy absorber for automotive bumper: pedestrian lower extremity protection

Designing an energy absorber for automotive bumpers involves balancing low-speed and high-speed impacts to ensure safety, reduce repair costs, and meet regulatory standards. Here, this study explores a novel design using multi-material 3D printing and structural optimization to fabricate a lightweight and cost-efficient energy absorber. The design effectively dissipates energy in low-speed collisions and minimizes force transmission in high-speed pedestrain impacts, helping to meet both safety and performance requirements. The energy absorber design combines 20% carbon fiber-reinforced acrylonitrile butadiene styrene (CF-ABS) and thermoplastic polyurethane (TPU) for optimal stiffness and flexibility. It uses 3D-printed lattice structures optimized through finite element simulations to help meet both low-speed and high-speed impact requirements. Full-scale energy absorbers were 3D-printed using optimized CF-ABS/TPU blends and tested under high-speed impact using the Flexible Pedestrian Legform Impactor (Flex-PLI). For fair comparison, a baseline bumper with a traditional triangular lattice structure, also 3D-printed from the same CF-ABS/TPU materials, was similarly tested. Interestingly, both the optimized and baseline 3D-printed energy absorbers showed nearly identical performance, successfully meeting injury limits. Their performances were also benchmarked against an injection-molded energy absorber. While both 3D-printed and injection-molded designs met injury limits, the 3D-printed absorber exhibited a higher tibia bending moment, indicating an opportunity for further optimization. A Techno-Economic Analysis compared the costs of producing energy absorbers using traditional manufacturing and 3D printing. The analysis highlighted that 3D printing offers cost benefits for low to medium production volumes, with the total cost per energy absorber at ∼ $\$$74, compared to traditional methods that become economical beyond 2000 units.

Additive manufacturing↗