Search NASA⌕ Search

SEARCH · Search NASA

Results for “UTILITY SOLAR PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

887 records · Page 50

Physics based Reliability Models for Supercritical CO 2 Turbomachinery Components

CSP plants using sCO 2 power cycle can potentially achieve high thermal conversion efficiency at low capital cost due to compact turbo-machinery and other components. An sCO 2 expander and improved heat exchanger is expected to provide a major stepping stone for achieving CSP power at 0.06/kW-hr LCOE, energy conversion efficiency > 50 % ,and total power block cost< $1,200/kW installed. Hybrid gas bearings (HGB) and Dry gas seals (DGS) are two key components that are critical for robust and efficient operation of future sCO 2 power cycles. From a system perspective, HGBs can provide substantial benefits (~3 to 5%) to the modular CSP operation, while use of DGSs limits the leakage losses as well as the windage losses in the generator and can increase overall generator efficiency by ~ 8%. The life limiting mechanisms of HGBs and DGSs in high pressure, high temperature sCO 2 environment were not well understood and hence this program aims at developing physics-based performance prediction and life prediction models for these two components. The output of the performance models serves as input to the life models. The performance models were validated using experimental data and using data from literature. DGS and HGB models have shed light on some risks associated with its operation in sCO 2 expander and will guide more robust designs tailored towards sCO 2 cycle applications. A DGS was tested in 1MWe sCO 2 turbo expander to study its performance and validate the performance models. To understand the effect of high pressures, high temperatures and sCO 2 environment on crack initiation, crack propagation and LCF/HCF life of these components, a novel experimental setup was developed. The LCF test data was used to calibrate and validate the life prediction models. The effect of sCO 2 corrosion on the life of Ni-based super-alloys is quantified using long duration experiments. Advanced microstructure and spectroscopic analyses conducted shed light on some key differences between IN718 and IN617 in terms of oxidation morphology, chemical species diffusion and trapping, the formation of protective corrosion resistant layers and changes in surface properties. A novel crack initiation model was developed which takes into account strain distribution, temperature, hold times and activation energy at the gas-metal interface and predicts the number of cycles to initiate the crack in the Inconel alloy. An advanced 3D fracture mechanics-based crack propagation model was also developed which takes into account the transient loading mission of the component and predict how fast the crack will grow and what will be its final shape and size. High energy X-Ray tomography measurements were conducted to study and validate 3D morphology of crack growth inside the specimen. These two models along with chemical kinetics models obtained from corrosion tests can be combined to predict the total life of the component under given long term operating conditions. A Bayesian Hybrid Modeling (BHM) probabilistic framework was developed to quantify uncertainty in physics-based performance models and in crack initiation and crack propagation models, to calibrate the models and to validate the models with statistical confidence. Advanced coupled physics multi-phase flow models were developed to study condensation, boiling and phase change behavior of CO 2 under various sCO 2 turbomachinery and heat exchanger conditions. A novel experimental setup was also designed to observe phase change of CO 2 during its transition across liquid-gas-supercritical state lines.

14 SOLAR ENERGY↗

USU Alternative and Unconventional Energy Research and Development

The purpose and rationale of this project has been to develop enduring research capabilities at Utah State University (USU) and the Utah State University Research Foundation (USURF) in a number of energy efficient and renewable energy areas including primarily a) algae energy systems, b) solar lighting, c) intuitive buildings, d) electric transportation, 3) unconventional energy environmental monitoring and beneficial reuse technologies (water and CO 2 ), f) wind energy profiling, and g) land use impacts. The long-term goal of this initiative has been to create high-wage jobs in Utah and a platform for sustained faculty and student engagement in energy research. The program’s objective has been to provide a balanced portfolio of R&D conducted by faculty, students, and permanent staff. This objective has been met. While some of the project’s tasks met with more success than others, as with any research project of this scope, overall the research has contributed valuable technical insight and broader understanding in key energy related areas. The algae energy systems research resulted in a highly productive workforce development enterprise as it graduated a large number of well prepared students entering alternative energy development fields and scholarship. Moreover, research in this area has demonstrated both the technological and economic limitations and tremendous potential of algae feedstock-based energy and co-products. Research conducted in electric transportation, specifically in both stationary and dynamic wireless inductive coupling charging technologies, has resulted in impactful advances. The project initiated the annual Conference on Electric Roads and Vehicles (http://www.cervconference.org/), which is growing and attracts more than 100 industry experts and scholars. As a direct result of the research, the USU/USURF spin-out startup, WAVE (Wireless Advanced Vehicle Electrification), continues work in wirelessly charged bus transit systems and is poised to quickly become a multi-million dollar company with clients around the globe. Moreover, USU students and researchers alike are now on the leading edge of the electrified transportation workforce. Finally, the legacy of this DOE investment in electric transportation is continuing at USU with the formation in progress of an industry sponsored research center built around the Electric Roadway and Vehicle (EVR) research facility and test track (http://evr.usu.edu). The research conducted in unconventional energy environmental monitoring and beneficial reuse technologies experienced broad success developing experimental and modeling tools and implementing those tools to better understand environmental impacts of industrial processes used in unconventional energy development in the Utah’s Uintah Basin. Before this project began the USU Uintah Basin branch campus had minimal capability to perform this regionally critical environmental research. This research investment enabled monitoring and modeling equipment and expertise to assess impacts of energy development to all aspects of environmental quality. Laboratory capability for environmental analysis has been developed and engaged along with field testing at multiple locations. Successful campaigns to measure greenhouse gas and hydrocarbon emissions from produced water surface impoundments and leakage from subsurface oil and gas infrastructure were executed. A computer model of meteorological conditions during winter inversion episodes was created, and commercialization efforts are underway for those models. Finally, in the past 24 months, nearly $2 million in non- DOE external funding from state, local, federal and private entities has been awarded to USU Uintah Basin to continue and add to work and capability established by this task. The preceding examples represent a few highlights resulting from the USU Alternative and Unconventional Energy Research and Development project. The following report provides further detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Storage Capacity Low Cost Iron Flow Battery

A new flow battery was proposed that utilizes low cost materials: iron as the only active element, cheap aqueous electrolytes, and inexpensive separators. During charging, ferrous iron (Fe 2+ ) is oxidized to ferric iron (Fe 3+ ) at the positive electrode while it (Fe 2+ ) is reduced to form iron metal (Fe 0 ) at the negative electrode. Because iron is plated at the negative electrode during charging, conventional electrode structures couple the energy storage capacity and the power rating of the battery. In order to decouple the energy and power ratings and regain the economic advantages of a flow battery, a slurry electrode design was proposed for use as the negative electrode. The slurry electrode is made by flowing electrically conductive particles in an electrolyte containing the dissolved iron species. On charging, iron is plated onto the particles. The particles can then carry the iron metal out of the cell to be stored in external reservoirs. This project looked to develop a slurry for the negative electrode of the all-iron flow battery that can operate at 200 mA/cm 2 with <100 mV overpotential, be pumped with parasitic energy costs < 10%, and promote plating on the particles. A scalable and stackable cell design of 1100 cm 2 was developed. The project was initially under contract in mid-January 2013. The project was converted from a one-year proof of concept seedling to an additional two-year program, then extended with an 18-month plus-up, and finally with an additional 6-month approved cost-overrun. During the seeding project, the concept of plating on carbon particles in a slurry was demonstrated. However, this was accomplished with high-cost multi-walled carbon nanotubes as the slurry material. The following two-year program discovered several low-cost carbon blacks that could also be used in this application. These findings were supported by an analysis that demonstrated the effectiveness of the carbon that takes into account not just the effective electronic conductivity of the slurry, but also the surface area per volume of the slurry. It was demonstrated that stable, flowable slurries could be created with these carbons, even when the carbons where fully loaded with iron during charging. During the two-year program, laboratory-scale 50 cm 2 single-cells demonstrated charge-discharge cycling at current densities of 150 mA/cm 2 and energy efficiencies of >50%. Meanwhile, cost modeling continued to show promise for this energy storage approach. Following the conversion period, the overall objective of the nominally 18-month plus up period was to close the technical gap of a 25X scale-up and reduce risk to enable commercial investment required to develop a slurry iron flow battery product. A specific objective was to demonstrate 150 cycles of performance exceeding 70% energy efficiency with a 10-cell stack of 1156 cm 2 cells operating at 100 mA/cm 2 . The 10-cell short stack was designed to have a power delivery rating of approximately 1 kW, which represents a size commensurate with the requirements of our commercialization partner at that time. A complete battery support system for the full-size cell was designed, fabricated, and tested. This includes pumps (multiple types were considered, and constant volume hose pumps were found to be acceptable for performance and cost), electrolyte rebalance reactor, and sensors and control systems. The support system proved to be well-behaved and worked well. A new low-cost membrane was developed for this system based on a microporous polymer support with a layer of hydrogel polymer. The membrane had low resistivity, and significantly reduced pressure driven fluid flow across the membrane (as compared to the un-coated microporous support). This membrane approach was scaled-up in conjunction with a commercial toll coating company, and a large amount of membrane was manufactured to support large cell and stack testing. A new concept for an electrolyte rebalance reactor to react hydrogen gas from the negative electrolyte (from plating inefficiency) with excess ferric ion in the positive electrolyte was developed. This design was very simple, low cost, and effective. The full scale 1156 cm 2 single-cell was designed, modeled, fabricated and tested. Modeling showed that uniform flow-distribution should be obtained with the designed flow distributor. The design took into consideration the need to stack the cells, and components were fabricated for a ten-cell stack. Testing of the cell for charge and discharge demonstrated current densities of 50 mA/cm 2 with efficiencies of 50%. However, optimization and long cycling could not be accomplished because the slurry electrode would plug within the cell and block the flow. This would shut down the cell after several charge-discharge cycles. Various approaches were pursued to address this problem with some progress. However, there was not adequate time to find solutions to the problem although several promising approaches were identified for future work. The final deliverable for this proposed 18-month effort was to be a 1 kW, 6 kWh slurry flow battery, with complete balance of plant, ready for testing at an ARPA-E ‘Charges’ site with an estimated capital cost less than $\$ $45/kWh for a six-hour system (excluding power electronics). The deliverable milestone was not achieved for reasons mentioned above related to the slurry plugging. At the completion of this project, it was determined that the cost targets are achievable. The cost estimate for a 1 MW system with a one-hour capacity was estimated at $\$ $140/kWh (including power electronics) and for a six-hour system was estimated at $\$ $40/kWh (including power electronics). These costs include the battery, the balance of plant, the power conditioning and a concrete pad. This program resulted in three patents including the slurry-based iron flow battery, the rebalance reactor, and the membrane separator. At the time of this report, slurry-based iron flow battery patents have been issued in the US, China, Japan, Korea, and Europe. The other patent applications were under various stages of examination. A licensee was identified and the company initiated a scale-up and development program to take this technology to the marketplace, and CWRU staff have transferred their know-how and knowledge base to the company. This technology will enhance the economic and energy security of the United States by enabling the use of intermittent renewable energy technology, such as wind and solar power, as dispatchable resources. This report summarizes the results of this research and development program.

25 ENERGY STORAGE↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗