Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ∼ <#comment/> 1000 to ∼ <#comment/> 3500 c m − <#comment/> 1 but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

Doughty, Benjamin (ORCID:0000000164299329)↗

Predeployment progress of the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a summary of the surface sampling activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. One goal of this testing is to collect defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion cracking (CISCC) research. Another goal is to provide data for the validation of computational fluid dynamics (CFD) based deposition modeling. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed CFD modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about the thermal-hydraulic behavior of horizontal dry cask storage systems. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer detailed quantification and composition of the deposited particulates from a realistic storage environment. Discussions of a potential host site for the Canister Deposition Field Demonstration (CDFD) are ongoing. Until a host site is chosen, testing of key CDFD hardware components including the heater assemblies, power skid, and remote data acquisition system will continue. Functional testing of the finalized heater assemblies and test apparatus started this fiscal year. These initial heater tests have shown the assemblies are performing within design specifications. Staged surface sampling of a mockup of a canister outside the AHSM on a transfer skid was also performed. Refinements to the sampling procedures and techniques were captured from observation of these activities and lessons-learned debriefs. These updated sampling procedures and techniques are planned to be tested again in the field using the mockup in order to assure personnel are using the most accurate and repeatable methods possible prior to deployment for actual CDFD testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solar Technology Acceleration Center (SolarTAC): Solar Resource & Meteorological Assessment Project (SOLRMAP)

Located in Colorado, near Denver International Airport, Solar Technology Acceleration Center (SolarTAC) is a private, member-based, 74-acre outdoor facility where the solar industry tests, validates, and demonstrates advanced solar technologies. SolarTAC was launched in 2008 by a public-private consortium, including Midwest Research Institute (MRI). As a supporting member of SolarTAC, the U.S. Department of Energy National Renewable Energy Laboratory (NREL) has established a high quality solar and meteorological measurement station at this location. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar powered projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.

14 SOLAR ENERGY↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗

Embedded Data Acquisition Tools for Rotorcraft Diagnostic Sensors

Rotorcraft drive trains must withstand enormous pressure while operating continuously in extreme temperature and vibration environments. Captive components, such as planetary and spiral bevel gears, see enormous strain but are not accessible to fixed instrumentation, such as a piezoelectric transducer. Thus, it is difficult to directly monitor components that are most susceptible to damage. This innovation is a self-contained data processing unit within a specialized fixture that installs directly inside the rotating pinion gear in the gearbox. From this location, it detects and transmits high-resolution prognostic data to a fixed transceiver. The sensor is based on microelectromechanical systems (MEMS) technology and uses innovative circuit designs to capture high-bandwidth data and transmit it wirelessly from inside an operational helicopter transmission. With Ridgetop's advanced MEMS-based sensor, researchers have, for the first time, been able to extract high-resolution acoustic signatures wirelessly from sensors within the transmission that would otherwise be muffled by background gear noises. Ridgetop's innovative instrument will help researchers perform dynamic analysis of gear interaction and develop improved designs for gear components. In addition, data from this instrument can be used to validate new algorithms that detect and predict faults based on external acoustic signatures, for prognostic purposes. The result of this work will be an improvement in safety, performance, and cost for future generations of rotating components.

Wagoner, Robert↗

Residential retrofits at scale: opportunity identification, saving estimation, and personalized messaging based on communicating thermostat data

Basic insulation and heating system retrofits of existing homes could achieve annual energy savings of up to $4–5 billion in the USA. However, current US utility energy efficiency (EE) programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and on-line advertising that lack specificity about particular home retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments that can be inconvenient to homeowners, expensive, and of variable accuracy. Our paper discusses using communicating thermostat data to significantly increase the customer uptake of energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. We extended our previously developed gray-box building model to identify physical building parameters corresponding to the target retrofit opportunities, i.e., whole-home R value, air leakage characteristics, and heating system efficiency. Here, the estimated R values and air leakage characteristics compare favorably with the ground truth. The validated algorithms can calculate home-specific energy savings estimate for each ECM, and the algorithm outputs can be used by utility EE programs to formulate home-specific retrofit offers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery

A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.

Luo, Yu↗

Low power on-chip data transmission for wafer-scale monolithic active pixel sensors

Here, this paper details the implementation of the digital pulse shaping subsystem within the Backbone Transmission Line Encoding (BTLE) driver, a low-power, long-distance on-chip data transmission solution designed in a 65 nm CMOS process. Digital pulse shaping is critical for minimizing inter-symbol interference (ISI) caused by bandwidth limitations of on-chip interconnects, especially in wafer-scale monolithic active pixel sensors (MAPS). A duobinary encoder coupled with a parallelized polyphase finite impulse response (FIR) filter is used for efficient shaping of the transmitted signal spectrum. This reconfigurable architecture achieves reliable 160 Mb/s data transfer over a 10 cm on-chip link, as validated by simulations demonstrating low power consumption (FoM 37.3 fJ/bit/mm of transmission line length) and effective ISI mitigation.

47 OTHER INSTRUMENTATION↗

TU-FG-209-07: Medical Physics 1.0 Versus Medical Physics 2.0: A Case Study

Purpose: To illustrate how performance analytics can identify performance decrement in digital radiography systems. Methods: Subsequent to a radiologist’s image quality complaint, four different advanced methods contributed to root cause analysis. Our system was a GE Revolution XQi digital radiography unit. Initially, we reviewed weekly GE Quality Assurance Procedures (QAP) results in a database dating from 2001. Next, we evaluated objective image quality metrics of individual PA Chest radiographs acquired. These images were anonymized, securely transferred, and analyzed by the Duke University Clinical Imaging Physics Group with software previously described{sup 1} and validated{sup 2}. Third, we compared the exposure-dependent SNR{sup 2} (NEQ) of the unit with previously established confidence limits{sup 3}. Finally, we explored our service database to reveal events that might affect detector performance. Results: QAP reported a decrease in CNR reflected in a significant increase in lung noise(Ln), mediastinum noise(Mn), and subdiaphragm-lung contrast(Slc) with a significant decrease in lung grey level(Lgl) after detector replacement. Most change occurred during week 1, before the QAP indicated one-half the ultimate decrease in CNR. After detector recalibration, QAP CNR improved, but was not restored to previous levels. Lgl and Slc were no longer significantly different from before, however Ln and Mn remained significantly different. Exposure-dependent SNR2 show the detector to be operating within limits in October 2006 but subsequently became miscalibrated sometime before acquisition of the 2011–2014 data. Service records revealed catastrophic failure of the Image Detection Controller that contained the 2007 calibration. Traditional metrics did not indicate that the system was performing outside of normal limits. Conclusion: Performance analytics are powerful tools whose proper application could allow early intervention in degraded system performance. The image-quality metrics appear to be highly sensitive to system performance and are reported with every acquisition rather than at arbitrary intervals. Confidence intervals may require customization for individual systems or detectors.

60 APPLIED LIFE SCIENCES↗

Standard Flow Liquid Chromatography for Shotgun Proteomics in Bioenergy Research

Over the past 10 years, the bioenergy field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular, the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuelproducing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min) for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 min gradients with standard flow chromatography, we were able to routinely identify nearly 800 proteins from E. coli samples; while for samples from Arabidopsis, over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge, this study represents the first attempt to validate the standard flow approach for shotgun proteomics.

09 BIOMASS FUELS↗

ROSAT investigation of flaring and activity on Prox Cen

The objective of this program was to investigate with high sensitivity the low-level flare activity which may underlie coronal heating. This was done. The ROSAT observations of Prox Cen were scheduled for 50 ks spread out from 26 Feb. - 10 Mar. 1992. Unfortunately because of spacecraft problems many of these pointings turned out to contain no useful data or extremely truncated valid data sets. Considerable time was spent trying to determine which of the data would be scientifically useful and which would not. Fortunately, several developments took place to augment the original data in such a way that the scientific goal of advancing the study of flaring and variability was able to be achieved after all. These are as follows: (1) a second round of ROSAT observations was carried out in Feb. 1993 which only came to the attention of the PI in Apr. 1993 when a new data tape arrived; (2) simultaneous IUE observations were requested and obtained; (3) data from the UK WFC are available via the collaboration with Dr. G. Bromage; and (4) the 'cleaned-up' original data set was found to include one major flare and 2 moderate flares. Because of the problems with the original data set, the unexpected acquisition of new data only two months ago, and the availability of IUE and WFC data, an article on Prox Cen for publication is not ready at this time. Such an article is being developed and can be completed as part of ongoing ROSAT research efforts on stellar coronae and flaring.

Haisch, Bernhard↗

A Microphone Phased Array for Launch Acoustics Application

A new, portable, phased array of microphones is built at NASA Ames Research Center specifically for the harsh environment encountered in launch pads of rocket vehicles. It uses 70 rugged, piezo-electric, dynamic pressure sensors optimally distributed on a 10.5ft diameter open frame dome structure. The open frame is light yet robust to sustain the high wind load of typical seaside launch pads, and the blast and acoustic loads from the launch. A 200-ft long cable bundle carries the microphone signals to a weather-protected electronic cabinet containing the data acquisition system, computers, and other equipment. The array is equipped with an infra-red camera and a visible wavelength camera for imaging the launch site. The beamformed noise maps will be superimposed on the video footages collected by the cameras for correct identification of the noise sources. The array is tested with very loud noise sources to determine the beamforming ability. Multiple mathematical models, such as the conventional beamforming, orthogonal-functional beamforming, spectral element method etc. are used to determine the minimum spatial resolution of the sound sources that can be measured at different frequencies. Additionally, the array hardware is being tested for different environmental conditions and electro-magnetic compliance. The goal is to use the array for NASA’s Artemis/SLS vehicle that will be launched from a newly built Mobile Launch platform and a modified launch pad. Data from a couple of validation tests will be presented in this paper. The first test involves an outdoor setup where the array was placed on a crane at several different heights and distances from a pair of very loud noise sources. The second test from the static firing of the RS25 engines in an outdoor test stand.

Acoustics↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REVEAL: Software Documentation and Platform Migration

The Research Environment for Vehicle Embedded Analysis on Linux (REVEAL) is reconfigurable data acquisition software designed for network-distributed test and measurement applications. In development since 2001, it has been successfully demonstrated in support of a number of actual missions within NASA s Suborbital Science Program. Improvements to software configuration control were needed to properly support both an ongoing transition to operational status and continued evolution of REVEAL capabilities. For this reason the project described in this report targets REVEAL software source documentation and deployment of the software on a small set of hardware platforms different from what is currently used in the baseline system implementation. This report specifically describes the actions taken over a ten week period by two undergraduate student interns and serves as a final report for that internship. The topics discussed include: the documentation of REVEAL source code; the migration of REVEAL to other platforms; and an end-to-end field test that successfully validates the efforts.

Wilson, Michael A.↗

SU-G-BRA-02: Development of a Learning Based Block Matching Algorithm for Ultrasound Tracking in Radiotherapy

Purpose: To develop an ultrasound learning-based tracking algorithm with the potential to provide real-time motion traces of anatomy-based fiducials that may aid in the effective delivery of external beam radiation. Methods: The algorithm was developed in Matlab R2015a and consists of two main stages: reference frame selection, and localized block matching. Immediately following frame acquisition, a normalized cross-correlation (NCC) similarity metric is used to determine a reference frame most similar to the current frame from a series of training set images that were acquired during a pretreatment scan. Segmented features in the reference frame provide the basis for the localized block matching to determine the feature locations in the current frame. The boundary points of the reference frame segmentation are used as the initial locations for the block matching and NCC is used to find the most similar block in the current frame. The best matched block locations in the current frame comprise the updated feature boundary. The algorithm was tested using five features from two sets of ultrasound patient data obtained from MICCAI 2014 CLUST. Due to the lack of a training set associated with the image sequences, the first 200 frames of the image sets were considered a valid training set for preliminary testing, and tracking was performed over the remaining frames. Results: Tracking of the five vessel features resulted in an average tracking error of 1.21 mm relative to predefined annotations. The average analysis rate was 15.7 FPS with analysis for one of the two patients reaching real-time speeds. Computations were performed on an i5-3230M at 2.60 GHz. Conclusion: Preliminary tests show tracking errors comparable with similar algorithms at close to real-time speeds. Extension of the work onto a GPU platform has the potential to achieve real-time performance, making tracking for therapy applications a feasible option. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

A Status of the Advanced Space Transportation Program from Planning to Action

A Technology Plan for Enabling Commercial Space Business was presented at the 48th International Astronautical Congress in Turin, Italy. This paper presents a status of the program's accomplishments. Technology demonstrations have progressed in each of the four elements of the program; (1) Low Cost Technology, (2) Advanced Reusable Technology, (3) Space Transfer Technology and (4) Space Transportation Research. The Low Cost Technology program element is primarily focused at reducing development and acquisition costs of aerospace hardware using a "design to cost" philosophy with robust margins, adapting commercial manufacturing processes and commercial off-the-shelf hardware. The attributes of this philosophy for small payload launch are being demonstrated at the component, sub-system, and system level. The X-34 "Fastrac" engine has progressed through major component and subsystem demonstrations. A propulsion system test bed has been implemented for system-level demonstration of component and subsystem technologies; including propellant tankage and feedlines, controls, pressurization, and engine systems. Low cost turbopump designs, commercial valves and a controller are demonstrating the potential for a ten-fold reduction in engine and propulsion system costs. The Advanced Reusable Technology program element is focused on increasing life through high strength-to-weight structures and propulsion components, highly integrated propellant tanks, automated checkout and health management and increased propulsion system performance. The validation of rocket based combined cycle (RBCC) propulsion is pro,-,ressing through component and subsystem testing. RBCC propulsion has the potential to provide performance margin over an all rocket system that could result in lower gross liftoff weight, a lower propellant mass fraction or a higher payload mass fraction. The Space Transfer Technology element of the program is pursuing technology that can improve performance and dramatically reduce the propellant and structural mass of orbit transfer and deep space systems. Flight demonstration of ion propulsion is progressing towards launch. Ion propulsion is the primary propulsion for Deep Space 1; a flyby of comet West-kohoutek-lkemura and asteroid 3352 McAuliffe. Testing of critical solar-thermal propulsion subsystems have been accomplished and planning is continuing for the flight demonstration of an electrodynamic tether orbit transfer system. The forth and final element of the program, Space Transportation Research, has progressed in several areas of propulsion research. This element of the program is focused at long-term (25 years) breakthrough concepts that could bring launch costs to a factor of one hundred below today's cost or dramatically expand planetary travel and enable interstellar travel.

Lyles, Garry↗