Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

TH-C-17A-09: Direct Visualization and Monitoring of Medical Radiation Beams in Air

Purpose: Radiation therapy errors are rare but potentially catastrophic. Recent fatal incidents could have been avoided by utilizing real-time methods of monitoring delivery of radiation during treatment. However, few existing methods are practical enough to be used routinely. The study presents the first experimental demonstration of a novel non-perturbing method of monitoring radiation therapy through the phenomena of air scintillation. Methods: Monitoring of radiation delivery was devised by leveraging the phenomena of nitrogen excitation in air by ionizing radiation. The excitation induced weak luminescence in the 300–400 nm range, a process called air scintillation. An electron-multiplication charge-coupled device camera (f/0.95 lens; 440 nm shortpass) was set-up in a clinical treatment vault and was used to capture air scintillation images of kilovoltage and megavoltage beams. Monte Carlo simulations were performed to determine the correlation of radiation dose to air scintillation. Results: Megavoltage beams from a Varian Clinac 21EX and kilovoltage beams from an orthovoltage unit (50 kVp, 30 mA) were visualized with a relatively short exposure time (10 s). Cherenkov luminescence produced in a plastic transparent phantom did not interfere with detection of air scintillation. The image intensity displayed an inverse intensity falloff (r{sup 2} = 0.89) along the central axis and was proportional to dose rate (r{sup 2} = 0.9998). As beam energy increased, the divergence of the imaged beam decreased. Last, air scintillation was visualized during a simulated total skin irradiation electron treatment. Conclusion: Air scintillation can be clinically detected to monitor a radiation beam in an inexpensive and non-perturbing manner. This new method is advantageous in monitoring for gross delivery and uniquely capable of wide area in a single acquisition, such as the case for online verification of total body / skin / lymphoid irradiation treatments.

60 APPLIED LIFE SCIENCES↗

The plasma environment during particle beam injection into space plasmas. I - Electron beams. II - Charge-neutral beams

A realistic electrostatic simulation model is used to investigate the plasma environment in the near vicinity of a spacecraft during the injection of electon beams from the spacecraft. The model is described, and the cases of injection into vacuum and into a low-density plasma are addressed. The relationship of the two-dimensional results to the purely field-aligned one-dimensional simulations is discussed. The dependence of the results on the ambient plasma density is investigated. Then, the properties of a charge-neutral beam and the plasma response are examined for the case where the beam has nonzero velocity components parallel and perpendicular to the magnetic field. The parameters used in the simulation are described, and the properties of the beam injection into the vacuum and in the case where a plasma is present are given.

Pritchett, P. L.↗

MO-A-BRD-07: Feasibility of X-Ray Acoustic Computed Tomography as a Tool for Calibration and In Vivo Dosimetry of Radiotherapy Electron and Photon Beams

Purpose: This work simulates radiation-induced acoustic waves to assess the feasibility of x-ray acoustic computed tomography (XACT) as a dosimeter. XACT exploits the phenomenon that acoustic waves with amplitude proportional to the dose deposited are induced following a radiation pulse. After detecting these acoustic waves with an ultrasound transducer, an image of the dose distribution can be reconstructed in realtime. Methods: Monte Carlo was used to simulate the dose distribution for monoenergetic 6 MeV photon and 9 MeV electron beams incident on a water tank. The dose distribution for a prostate patient planned with a photon 4-field box technique was calculated using clinical treatment planning software. All three dose distributions were converted into initial pressure distributions, and transportation of the induced acoustic waves was simulated using an open-source toolkit. Ideal transducers were placed around the circumference of the target to detect the acoustic waves, and a time reversal reconstruction algorithm was used to obtain an XACT image of the dose for each radiation pulse. Results: For the photon water tank relative dosimetry case, it was found that the normalized acoustic signal amplitude agreed with the normalized dose at depths from 0 cm to 10 cm, with an average percent difference of 0.5%. For the reconstructed in-plane dose distribution of an electron water tank irradiation, all pixels passed a 3%–3 mm 2D gamma test. The reconstructed prostate dose distribution closely resembled the plan, with 89% of pixels passing a 3%–3 mm 2D gamma test. For all situations, the amplitude of the induced acoustic waves ranged from 0.01 Pa to 1 Pa. Conclusion: Based on the amplitude of the radiation-induced acoustic waves and accuracy of the reconstructed dose distributions, XACT is a feasible technique for dosimetry in both calibration and in vivo environments for photon and electron beams and merits further investigation. Funding from NSERC, CIHR and McGill University. SH acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora

The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/c charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm 0.6$% and 84.1$\pm 0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.

43 PARTICLE ACCELERATORS↗

Magnetic field extraction of trap-based electron beams using a high-permeability grid

A method to form high quality electrostatically guided lepton beams is explored. Test electron beams are extracted from tailored plasmas confined in a Penning-Malmberg trap. The particles are then extracted from the confining axial magnetic field by passing them through a high magnetic permeability grid with radial tines (a so-called “magnetic spider”). An Einzel lens is used to focus and analyze the beam properties. Numerical simulations are used to model non-adiabatic effects due to the spider, and the predictions are compared with the experimental results. Improvements in beam quality are discussed relative to the use of a hole in a high permeability shield (i.e., in lieu of the spider), and areas for further improvement are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral atomic oxygen beam produced by ion charge exchange for Low Earth Orbital (LEO) simulation

A low energy neutral atomic oxygen beam system was designed and is currently being assembled at the Lewis Research Center. The system utilizes a 15 cm diameter Kaufman ion source to produce positive oxygen ions which are charge exchange neutralized to produce low energy (variable from 5 to 150 eV) oxygen atoms at a flux simulating real time low Earth orbital conditions. An electromagnet is used to direct only the singly charged oxygen ions from the ion source into the charge exchange cell. A retarding potential grid is used to slow down the oxygen ions to desired energies prior to their charge exchange. Cryogenically cooled diatomic oxygen gas in the charge exchange cell is then used to transfer charge to the oxygen ions to produce a neutral atomic oxygen beam. Remaining non-charge exchanged oxygen ions are then swept from the beam by electromagnetic or electrostatic deflection depending upon the desired experiment configuration. The resulting neutral oxygen beam of 5 to 10 cm in diameter impinges upon target materials within a sample holder fixture that can also provide for simultaneous heating and UV exposure during the atomic oxygen bombardment.

Banks, Bruce↗

Simulation of Current Filamentation Instability for an Accelerator Beam in a Capillary Plasma

Current Filamentation Instability (CFI) is of central importance for the propagation of relativistic electron beams in plasmas. It could play an important role in the generation of magnetic fields and of radiation in the after-glow of gamma ray bursts as well as in hot electrons energy transport in the fast-igniter inertial confinement fusion concept. Using the particle-in-cell code QuickPIC, simulations of the electron beam at the Brookhaven National Laboratory--Accelerator Test Facility, BNL-ATF, propagating in a cm-long plasma were conducted. Simulation results show that with beam and plasma parameters achievable at the BNL-ATF, the CFI should be observed within 2 cm of plasma. Simulation results are presented for an experiment currently underway at BNL-ATF and possible diagnostics for characterizing the instability are discussed.

43 PARTICLE ACCELERATORS↗

SU-F-T-507: Modeling Cerenkov Emissions From Medical Linear Accelerators: A Monte Carlo Study

Purpose: Cerenkov emissions are a natural byproduct of MV radiotherapy but are typically ignored as inconsequential. However, Cerenkov photons may be useful for activation of drugs such as psoralen. Here, we investigate Cerenkov radiation from common radiotherapy beams using Monte Carlo simulations. Methods: GAMOS, a GEANT4-based framework for Monte Carlo simulations, was used to model 6 and 18MV photon beams from a Varian medical linac. Simulations were run to track Cerenkov production from these beams when irradiating a 50cm radius sphere of water. Electron contamination was neglected. 2 million primary photon histories were run for each energy, and values scored included integral dose and total track length of Cerenkov photons between 100 and 400 nm wavelength. By lowering process energy thresholds, simulations included low energy Bremsstrahlung photons to ensure comprehensive evaluation of UV production in the medium. Results: For the same number of primary photons, UV Cerenkov production for 18MV was greater than 6MV by a factor of 3.72 as determined by total track length. The total integral dose was a factor of 2.31 greater for the 18MV beam. Bremsstrahlung photons were a negligibly small component of photons in the wavelength range of interest, comprising 0.02% of such photons. Conclusion: Cerenkov emissions in water are 1.6x greater for 18MV than 6MV for the same integral dose. Future work will expand the analysis to include optical properties of tissues, and to investigate strategies to maximize Cerenkov emission per unit dose for MV radiotherapy.

60 APPLIED LIFE SCIENCES↗

Electromagnetic forces on plasmonic nanoparticles induced by fast electron beams

The total momentum transfer from fast electron beams, like those employed in scanning transmission electron microscopy (STEM), to plasmonic nanoparticles is calculated. The momentum transfer is obtained by integrating the electromagnetic forces acting on the particles over time. Numerical results for single and dimer metallic nanoparticles are presented, for sizes ranging between 2 and 80 nm. We analyze the momentum transfer in the case of metallic dimers where the different relevant parameters such as particle size, interparticle distance, and electron beam impact parameter are modified. It is shown that depending on the specific values of the parameters, the total momentum transfer yields a force that can be either attractive or repulsive. The time-average forces calculated for electron beams commonly employed in STEM are on the order of piconewtons, comparable in magnitude to optical forces and are thus capable of producing movement in the nanoparticles. This effect can be exploited in mechanical control of nanoparticle induced motion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LANSCE CCL Performance Limits

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). Many factors contribute to the performance limits of the CCL accelerator system. One performance limit is set by the CCL mechanical structure and available cooling. Heating of the structure is ultimately linked to the operating RF duty factor of the CCL. Another performance limit is set by the maximum RF and beam duty factors that can be supported by the 805-MHz klystrons and associated HVDC power supplies. The RF and HVDC systems also set limits for the maximum peak beam current that can be accelerated in the CCL. And finally, a maximum beam current limit is set by the beam dynamics determined by the details of the CCL physics design (number of cells per CCL tank, accelerating gradients, magnetic focusing lattice, beam losses, etc.). This limit can be informed by both simulation results and beam measurement data, if available. A detailed explanation of each performance limit is given in the sections below. The results are summarized in the table below. In all cases, it is assumed that the CCL and the RF system are operating in their nominal beam production configuration – nominal magnet set points and nominal cavity fields, unless otherwise specified.

43 PARTICLE ACCELERATORS↗

Spontaneous ion beam formation in the laboratory, space, and simulation

We present experimental evidence for the spontaneous formation of multiple double layers within a single divergent magnetic field structure. Downstream of the divergent magnetic field, multiple accelerated ion populations are observed. The similarity of the accelerated ion populations observed in these laboratory experiments to ion populations observed in the magnetosphere and in numerical simulations suggests that the observation of a complex ion velocity distribution alone is insufficient to distinguish between simple plasma expansion and magnetic reconnection. Further, the effective temperature of the aggregate ion population is significantly larger than the temperatures of the individual ion population components, suggesting that insufficiently resolved measurements could misidentify multiple beam creation as ion heating. Ions accelerated in randomly oriented electric fields that mimic heating would have an ion heating rate dependent on the ion charge and mass that is qualitatively consistent with recent experimental observations of ion heating during magnetic reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crab Crossing Consideration for MEIC 2

Crab crossing of colliding electron and ion beams is essential for accommodating the ultra high bunch repetition frequency in the conceptual design of MEIC – a high luminosity polarized electron-ion collider at Jefferson Lab. The scheme eliminates parasitic beam-beam interactions and avoids luminosity reduction by restoring head-on collisions at interaction points. In this paper, we report simulation studies of beam dynamics with crab cavities for MEIC design. The detailed study involves full 3-D simulations of particle tracking through the various configurations of crab cavities for evaluating the performance. To gain insight, beam and RF dominated fields with other parametric studies will be presented in the paper.

43 PARTICLE ACCELERATORS↗

Impact of Prolonged Fraction Delivery Times Simulating IMRT on Cultured Nasopharyngeal Carcinoma Cell Killing

Purpose: To determine the impact of prolonged fraction delivery times (FDTs) simulating intensity-modulated radiotherapy (IMRT) on cultured nasopharyngeal carcinoma (NPC) cell killing. Methods and Material: Cultured NPC cell lines CNE1 and CNE2 were used in this study. The biological effectiveness of fractionated irradiation protocols simulating conventional external beam radiotherapy and IMRT (FDT of 15, 36, and 50 minutes) was estimated with standard colony assay, and the differences in cell surviving fractions after irradiation with different protocols were tested by use of the paired t test. The impact degree of prolonged FDTs (from 8 to 50 minutes) on cell killing was also assessed by the dose-modifying factors, which were estimated by comparing the effectiveness of intermittently delivered 2 Gy with that of continuously delivered 1.5 to 2 Gy. Results: The cell surviving fractions of both CNE1 and CNE2 after fractionated irradiation simulating IMRT were higher than those simulating conventional external beam radiotherapy (p < 0.05). The dose-modifying factors for a fraction dose of 2 Gy increased from 1.05 to 1.18 for CNE1 and from 1.05 to 1.11 for CNE2 with the FDT being prolonged from 15 to 50 minutes. Conclusions: This study showed that the prolonged FDTs simulating IMRT significantly decreased the cell killing in both CNE1 and CNE2 cell lines, and these negative effects increased with the FDT being prolonged from 15 to 50 minutes. These effects, if confirmed by in vivo and clinical studies, need to be considered in designing IMRT treatments for NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Orbit-averaging and deposition accuracy for runaway electron beams in hybrid kinetic-MHD simulations of the runaway plateau

We develop a new procedure that combines the kinetic orbit runaway electron code (KORC) and the NIMROD extended-magnetohydrodynamic code to simulate runaway electrons (REs) in the post-disruption plateau. KORC integrates guiding-center orbits, with a barycentric-based binary search strategy providing initial guesses for the Newton–Raphson logical-to-physical coordinate inversion, ensuring reliable particle-to-mesh mapping in NIMROD, whose fields remain static for the present study. Samples are drawn in accord with experimental parallel current profiles of RE beams during the plateau phase. Deposition in NIMROD is verified through comparison with a Python-based finite-element code that ensures periodicity in the poloidal direction and continuity at the magnetic axis. Accurate representation of near-axis fields requires finer mesh resolution to prevent under- and overshoots in current density from orbit inaccuracies. Yet, at a fixed particle count, increasing mesh resolution amplifies statistical noise in the deposited fields. An orbit-averaging method accumulates partial current deposits over multiple kinetic steps and reduces the statistical noise with little added computational cost. By coupling kinetic routines from KORC directly into the NIMROD codebase, these developments lay essential groundwork for future self-consistent KORC–NIMROD coupling.

Algorithms and data structure↗

Numerical 1D PIC-simulations of ion acceleration during laser-plasma interaction: Optimization of a two-component multilayered target structure

Ion beam acceleration is simulated using a one-dimensional 1D2P PIC code. The dependences of the maximum energy and width of the energy spectrum of the generated ion beams on the duration and intensity of laser radiation, as well as on the target parameters (thickness and number of layers, types and densities of atoms), are investigated. The optimal target configuration at which the energy of the accelerated ions is maximum (5-160 MeV for intensities of 5 x 10{sup 18-5} x 10{sup 20} W/cm{sup 2}) is found. The optimal target configuration is shown to depend on the intensity and be independent of the laser pulse duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of neutron emission in neutral beam injection heated plasmas with the real-time code RABBIT

In plasmas heated with deuterium beams a deficit of the expected fusion neutron rate is an indicator of the deterioration of the fast-ion confinement, caused, for instance, by magnetohydrodynamic instabilities. The capability of predicting this deficit during the discharge relies on the availability of real-time estimates of the neutron rate from NBI codes which must be fast and accurate at the same time. Therefore, the recently developed real-time RABBIT code for NBI simulations has been extended to output the distribution function and calculate the neutron emission. After the description of this newly installed diagnostics in RABBIT, benchmarks with NUBEAM, a massively used and validated Monte Carlo NBI solver, are discussed on ASDEX-Upgrade and JET cases. A first application for control-room intershot analysis on DIII-D is presented, and the results are compared on a large database with a slower NUBEAM analysis. Further application possibilities, e.g. for real-time control of Alfvén eigenmodes, are outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-658: Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation

Purpose: Patient dose far from the treatment field is comprised of scatter from within the patient, and treatment head leakage. We quantify the treatment head leakage for TrueBeam linear accelerator for 6X and 6X-FFF beams by comparing measurements to Monte Carlo simulations for a variety of jaw sizes and collimator rotations. This work is conceptually similar to that of Kry et al. (Medical Physics 2006; 33: 4405), who considered a Clinac linear accelerator. Methods: Measurements were made using an EXRADIN A101 ion chamber positioned in the patient plane, at distances up to 100 cm from isocenter. Simulations were done using VirtuaLinac, the GEANT4-based Monte Carlo model of the TrueBeam treatment head, and an in-house (U. Virginia) GEANT4-based code. In-house code modelled an ion chamber with build-up, based on a CT scan of the chamber. VirtuaLinac included a detailed model of the treatment head shielding, and was run on the Amazon Web Services cloud to generate spherical phase space files surrounding the treatment head. These phase space files were imported into the in-house code. Results: Initial comparisons between measurements and simulation showed an excess of dose in the in-plane direction, away from the gantry, in the simulations. This was traced to an incomplete model of the shielding—specifically, the component holding the primary collimator was smaller in the model than in the TrueBeam. Modifications were made to VirtuaLinac to more closely match the engineering drawings. In the in-plane direction, the lowest out of field dose was away from gantry (negative abscissa values) at around 60 cm from isocenter, for fields smaller than 10×10 cm2. Out of field dose decreased with decreasing jaw size. Flattening-filter free beam produced out-of-field doses as low as 65% of those with flattened beam. Conclusion: Doses determined from simulation and measurement were in close agreement. Funding support from the Jefferson Trust Foundation.

60 APPLIED LIFE SCIENCES↗