Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF)
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Atomic layer-by-layer molecular beam epitaxy (ALL-MBE) is a sophisticated technique to synthesize high-temperature superconductor (HTS) materials. ALL-MBE produces single-crystal HTS films with atomically smooth surfaces and interfaces, as well as precise multilayer heterostructures engineered down to a single atomic layer level. This enables the fabrication of tunnel junctions, nanowires, nanorings, and other HTS devices of interest. Our group has focused on ALL-MBE synthesis and materials science of La 2–x Sr x CuO 4 (LSCO), a representative HTS cuprate. In the past two decades, we have synthesized over three thousand LSCO thin films and characterized them by a range of analytical techniques. Here, we present in full detail a systematic process for the synthesis and engineering of atomically perfect LSCO films. The procedure includes the preparation of substrates, calibration of the elemental sources, the recipe for ALL growth of LSCO films without any secondary-phase precipitates, post-growth annealing of the films, and ex situ film characterization. This report should aid replication and dissemination of this technique of synthesizing single-crystal LSCO films for basic research as well as for HTS electronic applications.
We present the first interferometric observation of a zebra-pattern radio burst with simultaneous high spectral ({approx}1 MHz) and high time (20 ms) resolution. The Frequency-Agile Solar Radiotelescope Subsystem Testbed (FST) and the Owens Valley Solar Array (OVSA) were used in parallel to observe the X1.5 flare on 2006 December 14. By using OVSA to calibrate the FST, the source position of the zebra pattern can be located on the solar disk. With the help of multi-wavelength observations and a nonlinear force-free field extrapolation, the zebra source is explored in relation to the magnetic field configuration. New constraints are placed on the source size and position as a function of frequency and time. We conclude that the zebra burst is consistent with a double-plasma resonance model in which the radio emission occurs in resonance layers where the upper-hybrid frequency is harmonically related to the electron cyclotron frequency in a coronal magnetic loop.
The masses and radii of low-magnetic field neutron stars can be measured by combining different observable quantities obtained from their X-ray spectra during thermonuclear X-ray bursts. One of these quantities is the apparent radius of each neutron star as inferred from the X-ray flux and spectral temperature measured during the cooling tails of bursts, when the thermonuclear flash is believed to have engulfed the entire star. In this paper, we analyze 13,095 X-ray spectra of 446 X-ray bursts observed from 12 sources in order to assess possible systematic effects in the measurements of the apparent radii of neutron stars. We first show that the vast majority of the observed X-ray spectra are consistent with blackbody functions to within a few percent. We find that most X-ray bursts follow a very well determined correlation between X-ray flux and temperature, which is consistent with the whole neutron-star surface emitting uniformly during the cooling tails. We develop a Bayesian Gaussian mixture algorithm to measure the apparent radii of the neutron stars in these sources, while detecting and excluding a small number of X-ray bursts that show irregular cooling behavior. This algorithm also provides us with a quantitative measure of the systematic uncertainties in the measurements. We find that those errors in the spectroscopic determination of neutron-star radii that are introduced by systematic effects in the cooling tails of X-ray bursts are in the range {approx_equal} 3%-8%. Such small errors are adequate to distinguish between different equations of state provided that uncertainties in the distance to each source and the absolute calibration of X-ray detectors do not dominate the error budget.
y-type spectral distortions of the cosmic microwave background allow us to detect clusters and groups of galaxies, filaments of hot gas and the non-uniformities in the warm hot intergalactic medium. Several CMB experiments (on small areas of sky) and theoretical groups (for full sky) have recently published y-type distortion maps. We propose to search for two artificial hot spots in such y-type maps resulting from the incomplete subtraction of the effect of the motion induced dipole on the cosmic microwave background sky. This dipole introduces, at second order, additional temperature and y-distortion anisotropy on the sky of amplitude few μK which could potentially be measured by Planck HFI and Pixie experiments and can be used as a source of cross channel calibration by CMB experiments. This y-type distortion is present in every pixel and is not the result of averaging the whole sky. This distortion, calculated exactly from the known linear dipole, can be subtracted from the final y-type maps, if desired.
The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.
Here, we report results from an extensive set of measurements of the β-decay response in liquid xenon. These measurements are derived from high-statistics calibration data from injected sources of both 3 H and 14 C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
Precision measurement of the beam pattern of an antenna is very important for many applications. While traditionally such measurement is often made in a microwave anechoic chamber or at a test range, measurement using an unmanned aerial vehicle offers a number of advantages: the measurement can be made for the assembled antenna on site, thus reflecting the actual characteristics of the antenna of interest, and more importantly, it can be performed for larger antennas which cannot be steered or easily measured using the anechoic chamber and test range. Here we report our beam measurement experiment with UAV for a 6 meter dish used in the Tianlai array, which is a radio astronomy experiment. Due to the dish's small collecting area, calibration with an astronomical source only allows for determining the antenna beam pattern over a very limited angular range. We describe in detail the setup of the experiment, the components of the signal transmitting system, the design of the flight path and the procedure for data processing. We find the UAV measurement of the beam pattern agrees very well with the astronomical source measurement in the main lobe, but the UAV measurement can be extended to the fourth side lobe. The measured position and width of each lobe also shows good agreement with electromagnetic field simulation. This UAV-based approach of beam pattern measurement is flexible and inexpensive, and the technique may also be applied to other experiments.
The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.
Purpose: An algorithm to convert the color image of scanned EBT2 radiochromic film [Ashland, Covington KY] into a dose map was developed based upon a principal component analysis. The sensitive layer of the EBT2 film is colored so that the background streaks arising from variations in thickness and scanning imperfections may be distinguished by color from the dose in the exposed film. Methods: Doses of 0, 0.94, 1.9, 3.8, 7.8, 16, 32 and 64 Gy were delivered to radiochromic films by contact with a calibrated Sr-90/Y-90 source. They were digitized by a transparency scanner. Optical density images were calculated and analyzed by the method of principal components. The eigenimages of the 0.94 Gy film contained predominantly noise, predominantly background streaking, and background streaking plus the source, respectively, in order from the smallest to the largest eigenvalue. Weighting the second and third eigenimages by −0.574 and 0.819 respectively and summing them plus the constant 0.012 yielded a processed optical density image with negligible background streaking. This same weighted sum was transformed to the red, green and blue space of the scanned images and applied to all of the doses. The curve of processed density in the middle of the source versus applied dose was fit by a twophase association curve. A film was sandwiched between two polystyrene blocks and exposed edge-on to a different Y-90 source. This measurement was modeled with the GATE simulation toolkit [Version 6.2, OpenGATE Collaboration], and the on-axis depth-dose curves were compared. Results: The transformation defined using the principal component analysis of the 0.94 Gy film minimized streaking in the backgrounds of all of the films. The depth-dose curves from the film measurement and simulation are indistinguishable. Conclusion: This algorithm accurately converts EBT2 film images to dose images while reducing noise and minimizing background streaking. Supported by a sponsored research agreement from IsoTherapeutics Group, LLC.
The effect of temperature changes on the light output of LAB based liquid scintillator is investigated in a range from –5 C to 30 °C with a-particles and electrons in a small scale setup. Two PMTs observe the scintillator liquid inside a cylindrically shaped aluminum cuvette that is heated or cooled and the temperature dependent PMT sensitivity is monitored and corrected. The a-emitting isotopes in dissolved radon gas and in natural Samarium (bound to a LAB solution) excite the liquid scintillator mixtures and changes in light output with temperature variation are observed by fitting light output spectra. Furthermore, also changes in light output by compton electrons, which are generated from external calibration g-ray sources, is analysed with varying temperature. Assuming a linear behaviour, a combined negative temperature coefficient of (–0:29 0:01) % /°C is found. Considering hints for a particle type dependency, electrons show (–0:17 0:02) % /°C, whereas the temperature dependency seems stronger for a-particles, with (–0:35 0:03) % /°C. Furthermore, due to a high sampling rate, a pulse shape analysis can be performed and shows an enhanced slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations.
Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.
The goal of this study was to observe the dependence of NaI RIID performance on temperature.
Hybrid Optimization Software Suite (HOSS) is based on finite-discrete element modeling to capture the complex physics of explosions. Calibration of near-source modeling for underground explosions in geophysical models is presented, showing the effects of the amplitude of radial and vertical seismic components.
Riverine plastic pollution has been found in all major U.S. rivers, but the exact amount of plastic being released to the oceans has not been quantified. Field studies conducted in U.S. rivers have used a range of sampling and analysis techniques and rarely measured the mass of the plastic collected. Measurements of riverine plastic pollution are needed to calibrate and validate models used to estimate the U.S. riverine plastic emissions to the oceans. This report surveys measurement methods used to quantify riverine pollution and current estimates of U.S. riverine plastic pollution from measurements and models. Measurement methods include field sampling and laboratory analysis. Field sampling methods are described for large (macro) and small (micro) plastic particles. Laboratory analysis methods are described for macro and microplastic with an emphasis on the detailed characterization processes of microplastics. Waterborne leachate analysis is also briefly described. Three models are described that estimate plastic pollution based on mismanaged plastic waste in the river catchment basins. The models were validated and calibrated with global data sources. The data sources were predominantly outside of the U.S., where the magnitude and composition of plastic pollution is different than what is found in U.S. rivers. Comprehensive measurements of riverine plastics are needed not only to characterize the riverine plastic pollution, but also parameterize and validate models of plastic fate and transport. This report also describes five key U.S. rivers that span a range of sizes and environmental conditions that could be sampled to obtain data to support characterization and model development of plastic pollution from rivers to oceans. Sampling and analysis protocol recommendations are made to ensure the highest quality of data are collected in the five rivers.
The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.
Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators on silicon that sense bursts of energy through tiny shifts in their resonance. In this work, we installed new devices in the QUIET facility's cryogenic test setup and used a network analyzer to drive them across a range of power levels. At each setting, we measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. And despite the increased noise at low power, our model consistently captured the resonance behavior. We observed that the resonant frequency stayed stable across most powers, the device s internal quality factor improved with stronger signals, and its coupling strength peaked mid‑range before leveling off. Overall, these findings confirm the detector s performance, laying groundwork for future work on energy calibration with pulsed optical sources.
Sensing device measures directly the density of compressible fluid existing simultaneously in both liquid and gaseous phases. The device is comprised of a capacitor connected as one leg of a bridge circuit, a power source, and an indicator calibrated to indicate density as a direct measurement.