Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Stereotactic Irradiation of the Postoperative Resection Cavity for Brain Metastasis: A Frameless Linear Accelerator-Based Case Series and Review of the Technique

Purpose: Whole-brain radiation therapy (WBRT) is the standard of care after resection of a brain metastasis. However, concern regarding possible neurocognitive effects and the lack of survival benefit with this approach has led to the use of stereotactic radiosurgery (SRS) to the resection cavity in place of WBRT. We report our initial experience using an image-guided linear accelerator-based frameless stereotactic system and review the technical issues in applying this technique. Methods and Materials: We retrospectively reviewed the setup accuracy, treatment outcome, and patterns of failure of the first 18 consecutive cases treated at Brigham and Women's Hospital. The target volume was the resection cavity without a margin excluding the surgical track. Results: The median number of brain metastases per patient was 1 (range, 1-3). The median planning target volume was 3.49 mL. The median prescribed dose was 18 Gy (range, 15-18 Gy) with normalization ranging from 68% to 85%. In all cases, 99% of the planning target volume was covered by the prescribed dose. The median conformity index was 1.6 (range, 1.41-1.92). The SRS was delivered with submillimeter accuracy. At a median follow-up of 12.7 months, local control was achieved in 16/18 cavities treated. True local recurrence occurred in 2 patients. No marginal failures occurred. Distant recurrence occurred in 6/17 patients. Median time to any failure was 7.4 months. No Grade 3 or higher toxicity was recorded. A long interval between initial cancer diagnosis and the development of brain metastasis was the only factor that trended toward a significant association with the absence of recurrence (local or distant) (log-rank p = 0.097). Conclusions: Frameless stereotactic irradiation of the resection cavity after surgery for a brain metastasis is a safe and accurate technique that offers durable local control and defers the use of WBRT in select patients. This technique should be tested in larger prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studies as a function of different ALD capping layers on cavity losses for QIS and accelerators

Niobium-based bulk SRF cavities have demonstrated exceptional performance. To further improve niobium cavity performance, we present studies involving a novel surface engineering process designed to prevent the formation of amorphous niobium oxides on the surface. This is achieved by encapsulating the niobium surface using thermal Atomic-Layer-Deposition (ALD). This technique has been shown to enhance the properties of niobium cavities and 2D resonators. This study not only aims to improve SRF performance at high fields but also has the potential to enhance the quality factor in low-field regimes, particularly for quantum applications. For the method to be effective, it is essential to have a clean interface between the encapsulating layer and the bulk niobium. Achieving this requires a uniform coating across the entire cavity surface and efficient removal of the underlying niobium oxides. To optimize the process, a variety of material characterization tools have been utilized to refine parameters such as thin film thickness and annealing conditions. Cavity RF measurements were performed at the vertical test facilities at FNAL to assess the Q vs. Eacc curves for accelerator applications, as well as at the SQMS dilution refrigerators to investigate the full two-level system (TLS) losses at milliKelvin and single-photon levels. Based on the results, we characterized the loss of different oxides in various regimes and applications, comparing them to natural niobium pentoxide.

Grassellino, L. [Fermilab]↗

High power edge-cum-surface emitting terahertz laser arrays phased locked by vacuum guided plasmon waves

Terahertz semiconductor quantum-cascade lasers (QCLs) are widely implemented with metallic cavities that support low-loss plasmonic optical modes at long wavelengths. However, resonant optical modes in such cavities suffer from poor radiative characteristics due to their subwavelength transverse dimensions. Consequently, single-mode terahertz QCLs with metallic cavities and large (>100 mW) output power have only been realized in the surface-emitting configuration that affords a large radiating surface. Here, we demonstrate a method to enhance radiative outcoupling from such plasmonic lasers for high-power emission in the edge-emitting (end-fire or longitudinal) direction. Single-sided plasmon waves propagating in vacuum are resonantly excited in surrounding medium of metallic cavities with the QCL semiconductor medium. The vacuum guided plasmon waves with a large wavefront phase-lock multiple metallic cavities longitudinally, which leads to intense radiation in multiple directions, including that in the longitudinal direction in a narrow single-lobed beam. The multicavity array radiates predominantly in a single spectral mode. A peak-power output of 260 mW and a slope efficiency of 303 mW/A are measured for the end-fire beam from a 3.3 THz QCL operating at 54 K in a Stirling cooler. Finally, single-mode operation and lithographic tuning across a bandwidth of ~150 GHz are demonstrated.

42 ENGINEERING↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-grid domain decomposition approach for solution of Navier-Stokes equations in primitive variable form

The new multigrid (or adaptive) pseudospectral element method was carried out for the solution of incompressible flow in terms of primitive variable formulation. The desired features of the proposed method include the following: (1) the ability to treat complex geometry; (2) high resolution adapted in the interesting areas; (3) requires minimal working space; and (4) effective in a multiprocessing environment. The approach for flow problems, complex geometry or not, is to first divide the computational domain into a number of fine-grid and coarse-grid subdomains with the inter-overlapping area. Next, it is necessary to implement the Schwarz alternating procedure (SAP) to exchange the data among subdomains, where the coarse-grid correction is used to remove the high frequency error that occurs when the data interpolation from the fine-grid subdomain to the coarse-grid subdomain is conducted. The strategy behind the coarse-grid correction is to adopt the operator of the divergence of the velocity field, which intrinsically links the pressure equation, into this process. The solution of each subdomain can be efficiently solved by the direct (or iterative) eigenfunction expansion technique with the least storage requirement, i.e. O(N(exp 3)) in 3-D and O(N(exp 2)) in 2-D. Numerical results of both driven cavity and jet flow will be presented in the paper to account for the versatility of the proposed method.

Ku, Hwar-Ching↗

Application of Active Seismic and Electrical Methods to Detect and Characterize Subsurface Effects of an Underground Explosion

During the period of underground nuclear testing in the U.S., now ended for over 20 years, the focus of work was to conduct the test and analyze the data as quickly as possible; there was little concern about application of technologies that could be used to detect and characterize the location and depth of the explosion. Thus, there is little experience with applying geophysical methods in places where an underground nuclear explosion (UNE) has taken place. On the other hand, application of geophysical methods to the detection of shallow artifacts and water table depth is commonly applied in the environmental remediation and site characterization realm of commercial geophysical surveys. For nuclear nonproliferation treaty applications which may incorporate both shallow and deep geophysical probing methods (such as on-site inspection (OSI) under the Comprehensive Nuclear Test Ban Treaty [CTBT]), there thus remains a need to better understand detection capabilities of the deeper targets: anomalies related to an explosion cavity or rubble zone that may be located several hundred meters below the ground surface. The purpose of this Coordinated Inspection Technologies (CIT) project was to gain experience in applying active seismic methods and electrical methods at a site in Nevada where an underground nuclear test (UNE) had been conducted in the past to get a better understanding of the capabilities of these methods for detection and characterization of deep subsurface effects of the explosion.

58 GEOSCIENCES↗

Aperiodic signals processing via parameter-tuning stochastic resonance in a photorefractive ring cavity

Based on solving numerically the generalized nonlinear Langevin equation describing the nonlinear dynamics of stochastic resonance by Fourth-order Runge-Kutta method, an aperiodic stochastic resonance based on an optical bistable system is numerically investigated. The numerical results show that a parameter-tuning stochastic resonance system can be realized by choosing the appropriate optical bistable parameters, which performs well in reconstructing aperiodic signals from a very high level of noise background. The influences of optical bistable parameters on the stochastic resonance effect are numerically analyzed via cross-correlation, and a maximum cross-correlation gain of 8 is obtained by optimizing optical bistable parameters. This provides a prospective method for reconstructing noise-hidden weak signals in all-optical signal processing systems.

97 MATHEMATICS AND COMPUTING↗

Method of laminating structural members

A laminate is obtained by providing a lightweight core material, such as a honeycombed plastic or metal, within the cavity defined by an annular mold cavity frame. Face sheets, which are to be bonded to the core material, are provided on opposite sides of the frame and extend over the frame, thus sealing the core material in the cavity. An adhesive is provided between the core material and the face sheets and the combined thickness of the core material and adhesive is a close fit within the opposed face sheets. A gas tight seal, such as an O-ring gasket, is provided between the frame and the face sheet members to form a gas tight cavity between the face sheet members and the frame. External heat and pressure are used to bond the face sheets to the core material. Gas pressure is introduced into the sealed cavity to minimize out-gasing of the adhesive.

Heier, W. C.↗

Device and Method for Reducing Aircraft Noise

A noise abatement device that is positioned adjacent to a body. The noise abatement device generally includes tabs or cavities which thicken the shear layer created by fluid flow over, around, or near the body, by creating horseshoe-shaped vortices; this thickening of the shear layer reduces the strength of fluctuations in the flow which produce noise.

Craig L Streett↗

System and method for a conformable pressure vessel

A vessel for storing fluid, the vessel including a liner having a liner body that defines: a liner cavity; a plurality of flexible connector portions that include a corrugated length that provides for flexibility of the respective connector portions, the connector portions having a first maximum diameter; a plurality of elongated tubing portions between the respective flexible connector portions, the elongated tubing portions having a second minimum diameter that is larger than the first maximum diameter of the flexible connector portions; and a plurality of taper portions coupling adjoining flexible connector portions and tubing portions configured to provide a transition between a smaller diameter of the connector portion and a larger diameter of the tubing portion.

33 ADVANCED PROPULSION SYSTEMS↗

Quench-Spot Detection for Superconducting Accelerator Cavities Via Flow Visualization in Superfluid Helium-4

Superconducting radio-frequency (SRF) cavities, cooled by superfluid helium-4 (He II), are key components in modern particle accelerators. Quenches in SRF cavities caused by Joule heating from local surface defects can severely limit the maximum achievable accelerating field. Existing methods for quench-spot detection include temperature mapping and second-sound triangulation. These methods are useful but also have known limitations. Here we describe an alternative method for surface quench-spot detection by visualizing the heat transfer in He II via tracking He2 molecular tracer lines. A proof-of-concept experiment is conducted, in which a miniature heater mounted on a plate is pulsed on to simulate a surface quench spot. A He2 tracer line created nearby the heater deforms due to the counterflow heat transfer in He II. By analyzing the tracer-line deformation, we well reproduce the heater location within a few hundred microns, which clearly demonstrates the feasibility of this alternative technology. Our analysis also reveals that the heat content transported in He II is only a small fraction of the total input heat energy. We show that the remaining energy is essentially consumed in the formation of a cavitation zone near the heater. By estimating the size of this cavitation zone, we discuss how the existence of the cavitation zone may explain a decades-long puzzle observed in many past second-sound triangulation experiments.

43 PARTICLE ACCELERATORS↗

Synchronizing femtosecond laser with x-ray synchrotron operating at arbitrarily different frequencies

The ability to synchronize a femtosecond laser to x-ray pulses is crucial for performing ultrafast time-resolved x-ray scattering experiments at synchrotrons. Conventionally, the task has been achieved by locking a harmonic frequency of the laser oscillator to the storage ring master radio-frequency (RF). However, when the frequency mismatch between the two sources cannot be compensated by small adjustments to the laser cavity length, synchronization to a harmonic frequency requires modifying the optical components of the laser system. We demonstrate a novel synchronization scheme, which is a flexible alternative for synchronizing these two sources operating at arbitrarily different frequencies. First, we find the greatest common divisor (GCD) of the two frequencies that is still within the limited tuning range of the laser cavity length. The GCD is generated by dividing down from the storage ring RF, and is separately multiplied up to provide a feedback signal for synchronizing the laser cavity. Unique to our scheme, the GCD also serves as a harmonic RF source for the laser amplifier such that only laser oscillator pulses at fixed integer multiples of the storage ring RF are selected for amplification and delivery to experiments. Our method is implemented at the Photon Test Facility beamline of Pohang Light Source where timing-jitter less than 4 ps (r.m.s.) is measured using a new shot-to-shot method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exact Potential Energy Surface for Molecules in Cavities

We find and analyze the exact time-dependent potential energy surface driving the proton motion for a model of cavity-induced suppression of proton-coupled electron transfer. We show how, in contrast to the polaritonic surfaces, its features directly correlate to the proton dynamics and we discuss cavity modifications of its structure responsible for the suppression. Furthermore, the results highlight the interplay between nonadiabatic effects from coupling to photons and coupling to electrons and suggest caution is needed when applying traditional dynamics methods based on polaritonic surfaces.

74 ATOMIC AND MOLECULAR PHYSICS↗

Elective Lymph Node Irradiation With Intensity-Modulated Radiotherapy: Is Conventional Dose Fractionation Necessary?

Purpose: Intensity-modulated radiation therapy (IMRT) is the standard of care for head-and-neck cancer (HNC). We treated patients with HNC by delivering either a moderate hypofractionation (MHF) schedule (66 Gy at 2.2 Gy per fraction to the gross tumor [primary and nodal]) with standard dose fractionation (54-60 Gy at 1.8-2.0 Gy per fraction) to the elective neck lymphatics or a conventional dose and fractionation (CDF) schedule (70 Gy at 2.0 Gy per fraction) to the gross tumor (primary and nodal) with reduced dose to the elective neck lymphatics. We analyzed these two cohorts for treatment outcomes. Methods and Materials: Between November 2001 and February 2009, 89 patients with primary carcinomas of the oral cavity, larynx, oropharynx, hypopharynx, and nasopharynx received definitive IMRT with or without concurrent chemotherapy. Twenty patients were treated using the MHF schedule, while 69 patients were treated with the CDF schedule. Patient characteristics and dosimetry plans were reviewed. Patterns of failure including local recurrence (LR), regional recurrence (RR), distant metastasis (DM), disease-free survival (DFS), overall survival (OS), and toxicities, including rate of feeding tube placement and percentage of weight loss, were reviewed and analyzed. Results: Median follow-up was 31.2 months. Thirty-five percent of patients in the MHF cohort and 77% of patients in the CDF cohort received chemotherapy. No RR was observed in either cohort. OS, DFS, LR, and DM rates for the entire group at 2 years were 89.3%, 81.4%, 7.1%, and 9.4%, respectively. Subgroup analysis showed no significant differences in OS (p = 0.595), DFS (p = 0.863), LR (p = 0.833), or DM (p = 0.917) between these two cohorts. Similarly, no significant differences were observed in rates of feeding tube placement and percentages of weight loss. Conclusions: Similar treatment outcomes were observed for MHF and CDF cohorts. A dose of 50 Gy at 1.43 Gy per fraction may be sufficient to electively treat low-risk neck lymphatics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-50: Finite Element-Based Deformable Image Registration of Lung and Heart

Purpose: Photodynamic therapy (PDT) is used after surgical resection to treat the microscopic disease for malignant pleural mesothelioma and to increase survival rates. Although accurate light delivery is imperative to PDT efficacy, the deformation of the pleural volume during the surgery impacts the delivered light dose. To facilitate treatment planning, we use a finite-element-based (FEM) deformable image registration to quantify the anatomical variation of lung and heart volumes between CT pre-(or post-) surgery and surface contours obtained during PDT using an infrared camera-based navigation system (NDI). Methods: NDI is used during PDT to obtain the information of the cumulative light fluence on every cavity surface point that is being treated. A wand, comprised of a modified endotrachial tube filled with Intralipid and an optical fiber inside the tube, is used to deliver the light during PDT. The position of the treatment is tracked using an attachment with nine reflective passive markers that are seen by the NDI system. Then, the position points are plotted as three-dimensional volume of the pleural cavity using Matlab and Meshlab. A series of computed tomography (CT) scans of the lungs and heart, in the same patient, are also acquired before and after the surgery. The NDI and CT contours are imported into COMSOL Multiphysics, where the FEM-based deformable image registration is obtained. The NDI and CT contours acquired during and post-PDT are considered as the reference, and the Pre-PDT CT contours are used as the target, which will be deformed. Results: Anatomical variation of the lung and heart volumes, taken at different times from different imaging devices, was determined by using our model. The resulting three-dimensional deformation map along x, y and z-axes was obtained. Conclusion: Our model fuses images acquired by different modalities and provides insights into the variation in anatomical structures over time.

60 APPLIED LIFE SCIENCES↗

In Situ Plasma processing of SRF cuperconducting cavities at JLAB, 2024 Update

Jefferson Lab has an ongoing R&D program in plasma processing. The experimental program investi-gated processing using argon/oxygen and heli-um/oxygen gas mixtures. Plasma processing is a com-mon technique where the free oxygen produced by the plasma breaks down and removes hydrocarbons from surfaces. This increases the work function and reduces the secondary emission coefficient. The initial focus of the effort was processing C100 cavities by injecting RF power into the high order mode (HOM) coupler ports. We also developed the methods for establishing a plasma in C75 cryomodules where the RF power is injected via the fundamental power-coupler. Four C100 cryomodules were in situ processed in the CE-BAF accelerator in May 2023 with the cryomodules returning to an operational status in Sept. 2023. The overall operational energy gain for the four cryomod-ules was 49 MeV. Methods, systems and results from processing cryomodules in the CEBAF accelerator and vertical test results are presented. Current status and future plans are discussed.

Powers, T.↗

Energy efficient engine. Volume 2. Appendix A: Component development and integration program

The large size and the requirement for precise lightening cavities in a considerable portion of the titanium fan blades necessitated the development of a new manufacturing method. The approach which was selected for development incorporated several technologies including HIP diffusion bonding of titanium sheet laminates containing removable cores and isothermal forging of the blade form. The technology bases established in HIP/DB for composite blades and in isothermal forging for fan blades were applicable for development of the manufacturing process. The process techniques and parameters for producing and inspecting the cored diffusion bonded titanium laminate blade preform were established. The method was demonstrated with the production of twelve hollow simulated blade shapes for evaluation. Evaluations of the critical experiments conducted to establish procedures to produce hollow structures by a laminate/core/diffusion bonding approach are included. In addition the transfer of this technology to produce a hollow fan blade is discussed.

Moracz, D. J.↗

An Alternative Derivation of the Nimbus 7 Total Solar Irradiance Variations

Nimbus 7 solar irradiance values have been made available to the scientific community through the open literature (e.g., Hickey et al., 1988) and through NASA data centers. A comparison of these measurements to the Solar Maximum Mission/Active Cavity Radiometer Irradiance Monitor (SSM/ACRIM) time series indicated differences which might be caused in part by the method of converting the Nimbus 7 raw data counts to solar irradiance values. In an effort to see if the derivation of the solar irradiance could be improved, the raw counts were extracted from the tapes and analyzed to see how a new algorithm could be constructed. The basic form of the calibration remains the same as in the previous solar irradiance derivations. However, the input values to the equation differ from what was used before. In particular, improved values of the Earth-sun distance are incorporated and new temperature sensitivities were derived. Several problems with the instrument were uncovered which previously had not been noticed. The sun did not appear to cross the center of field of the radiometer but was systematically off by 1.5 to 2.5 degrees. The analog to digital convertor changed its properties in July 1980. The gain of the electronics apparently increased by 0.03 percent in September 1987. Applying these and other changes in the processing, the day to day variations appear much more like the SMM observations. In fact, the Nimbus 7 observations are sufficiently stable that a problem with the SSM observations in the spin mode period of 1981 to 1984 can be detected when the two time series are compared.

Hoyt, Douglas V.↗