Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Stability, vibration and passive damping of partially restrained imperfect columns

A theoretical and experimental study of slender tubular columns for possible use in space structures is conducted in the presence of partial rotational end restraints. Explicit formulas are derived for computing the buckling load and the lowest natural frequency of perfectly straight uniform elastic members with rotational end restraints possessing linear moment-rotation characteristics. An exact solution in the form of a transcendental equation, and a numerical solution using second-order finite-differences are also presented. The presence of an initial imperfection is also incorporated into the numerical procedure. Vibration tests are conducted on an imperfect tubular steel member in the absence of an axial load. A damping concept consisting of a string-mass assembly is explored. Three passive damping configurations involving combinations of three lead shots were investigated. The three lead shot configurations provided considerably greater damping than the single lead shot.

Razzaq, Z.↗

Free tropospheric carbon monoxide concentrations in 1950 and 1951 deduced from infrared total column amount measurements

Published total vertical column amounts of carbon monoxide deduced from infrared solar spectra recorded during 1950-51 in the Swiss Alps have been reanalyzed based on improved spectroscopic parameters for CO and a curve of growth. From a comparison of the 1950-51 results and modern measurements, an average increase of about 2 percent per year in the free tropospheric concentration of CO above Europe is estimated for 1950-77.

Rinsland, C. P.↗

The development of the 15-Meter Hoop Column deployable antenna system with structural and electromagnetic performance results

This paper presents the technical results obtained during the development and engineering tests of a 15-Meter Hoop Column deployable antenna system. An important element of the 15-meter antenna program was the structural tests and the characterization of the surface accuracy of the deployed mesh surface. The overall system performance of the 15-meter antenna was obtained during radio frequency tests conducted in the Martin Marietta Near Field Test Laboratory in Denver, CO. The near field tests verified the electromagnetic performance of the structure which exhibited a surface accuracy of 0.061 in (RMS). Radio frequency tests were conducted at 2.3, 4.3, 7.7, and 11.6 GHz. The experiment and analytical results obtained through the 15-meter antenna program will provide new opportunities for the application of large space antennas for future missions.

Campbell, T. G.↗

Thermal analysis of radiometer containers for the 122m hoop column antenna concept

A thermal analysis was conducted for the 122 Meter Hoop Column Antenna (HCA) Radiometer electronic package containers. The HCA radiometer containers were modeled using the computer aided graphics program, ANVIL 4000, and thermally simulated using two thermal programs, TRASYS and MITAS. The results of the analysis provided relationships between the absorptance-emittance ratio and the average surface temperature of the orbiting radiometer containers. These relationships can be used to specify the surface properties, absorptance and reflectance, of the radiometer containers. This is an initial effort in determining the passive thermal protection needs for the 122 m HCA radiometer containers. Several recommendations are provided which expand this effort so specific passive and active thermal protection systems can be defined and designed.

Dillon-Townes, L. A.↗

Development of the 15 meter diameter hoop column antenna

The building of a deployable 15-meter engineering model of the 100 meter antenna based on the point-design of an earlier task of this contract, complete with an RF-capable surface is described. The 15 meter diameter was selected so that the model could be tested in existing manufacturing, near-field RF, thermal vacuum, and structural dynamics facilities. The antenna was designed with four offset paraboloidal reflector surfaces with a focal length of 366.85 in and a primary surface accuracy goal of .069 in rms. Surface adjustment capability was provided by manually resetting the length of 96 surface control cords which emanated from the lower column extremity. A detailed description of the 15-meter Hoop/Column Antenna, major subassemblies, and a history of its fabrication, assembly, deployment testing, and verification measurements are given. The deviation for one aperture surface (except the outboard extremity) was measured after adjustments in follow-on tests at the Martin Marietta Near-field Facility to be .061 in; thus the primary surface goal was achieved.

Source record↗

The 15 meter hoop-column antenna dynamics: Test and analysis

A 15 meter model of the hoop-column antenna concept has been vibration tested for model characterization and analytical model verification. Linear finite element analysis predicted the global vibration frequencies accurately. Good agreement between analysis and test data was obtained only after the analytical model was refined using static test data. As structures become more flexible, structural properties determined from static data become more accurate and should be used to update analytical models. Global vibration modes are not significantly affected by the surface mesh which permits simplified analytical models to be used for prediction of global behavior. These reduced models are believed sufficient for preliminary design and controls simulations where only global behavior is desired. The mesh modes were highly damped due to the knit mesh used for the reflector surface. These modes were also highly coupled and very difficult to measure in the laboratory. The inability to fully characterize the antenna mesh modes in the laboratory indicates robust methods for active surface vibration suppression will be needed. Fortunately, the surface mesh exhibits high passive damping which should be beneficial to active control systems.

Belvin, W. Keith↗

Vertical column abundance measurements of atmospheric hydroxyl from 26 deg, 40 deg, and 65 deg N

The vertical column abundance of atmospheric hydroxyl was measured with Pepsios spectrometers from Boca Raton, Florida (26.4 N); Fritz Peak, Colorado (40 deg N); and Poker Flat, Alaska (65 deg N). The data show a global solar zenith angle dependence for the OH abundances, with the general features common in measurements from all three locations since 1980. However, while theoretical models agree well with the pre-1980 abundances, the post-1980 data do not. It appears that a significant change in the atmospheric photochemistry needs to be introduced.

Burnett, Clyde R.↗

Non-seasonal changes in total column ozone from satellite observations, 1970-86

Analyses of nonseasonal changes in total column ozone from satellite observations during the period 1970-86 suggest, when combined with analyses of Dobson network data, that the largest reduction in global ozone since 1959 occurred between 1978 and 1986. The existence of an Arctic region of enhanced ozone depletion with similar but less pronounced characteristics of the Antarctic region is described. Before 1983 large rates of decrease were confined to high latitudes, subsequently regions of large rates of ozone depletion have appeared at midlatitudes.

Heath, Donald F.↗

Periodic behaviors in the observed vertical column abundances of atmospheric hydroxyl

The data base for the vertical column abundance of atmospheric hydroxyl (OH) for Fritz Peak Observatory, Colorado (40 N, 105 W), now extends from 1976 through 1988 and is composed of 8849 independent data sets, averaging about 15 percent uncertainty and 20-minute time resolution each. The dominant solar zenith angle (chi) dependence of the OH abundance is characterized by an empirical curve, N(88), which has been updated from N(82) to include all valid data from 1980 through 1988. The chi-dependence of the OH abundance has been, to a first order, removed from the data base by a normalization procedure in which each data point is divided by the N(88,AM) value for the corresponding solar zenith angle. The resulting normalized OH values may then be examined for other systematic effects, particularly for periodic variations. Observations have also been made at Boca Raton, Florida (26 N, 80 W) and at Truk, Federated States of Micronesia (7 N, 152 E). These data bases are much less extensive and, as such, are less amenable to analysis for periodic behaviors. Some comparisons with the Colorado data may be made, however.

Burnett, Elizabeth Beaver↗

Near-field testing of the 15-meter hoop-column antenna

A 15-m-diameter antenna was tested to verify that dimensional tolerances for acceptable performance could be achieved and to verify structural, electromagnetic, and mechanical performance predictions. This antenna utilized the hoop column structure, a gold plated molybdenum mesh reflector, and 96 control cables to adjust the reflector conformance with a paraboloid. The dimensional conformance of the antenna structure and surface was measured with metric camera and theodolites. Near field pattern data were used to assess the electromagnetic performance at five frequencies from 2.225 to 11.6 GHz. The reflector surface was adjusted to greatly improve electromagnetic performance with a finite element model and the surface measurements. Measurement results show that antenna surface figure and adjustments and electromagnetic patterns agree well with predictions.

Schroeder, Lyle C.↗

Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

Hattam, Paul↗

A study on the sensitivity and simultaneous adjustment of a hoop-column antenna surface

The results of a recent surface adjustment of the 15-meter diameter hoop-column antenna are presented. A least-squares differential algorithm is used to adjust the surface shape as close as possible to a perfect parabola. Since the desired perfect parabola is not uniquely known a priori, parameters of the perfect parabola are included in the design vector along with the cable length changes. As an extension to an earlier study, lateral sensitivity is included in the least-squares adjustment procedure. In addition, the effect of cable length uncertainties on the surface RMS error is considered and an error bound is derived. The results in this study indicate an improvement over earlier studies. The sensitivity analysis provided a quantitative measure of the needed accuracy of the cable adjustments in the laboratory. Recommendations are included to further enhance shape adjustment.

Lim, Kyong Been↗

Scaling effects in the static and dynamic response of graphite-epoxy beam-columns

Scale model technology represents one method of investigating the behavior of advanced, weight-efficient composite structures under a variety of loading conditions. It is necessary, however, to understand the limitations involved in testing scale model structures before the technique can be fully utilized. These limitations, or scaling effects, are characterized. in the large deflection response and failure of composite beams. Scale model beams were loaded with an eccentric axial compressive load designed to produce large bending deflections and global failure. A dimensional analysis was performed on the composite beam-column loading configuration to determine a model law governing the system response. An experimental program was developed to validate the model law under both static and dynamic loading conditions. Laminate stacking sequences including unidirectional, angle ply, cross ply, and quasi-isotropic were tested to examine a diversity of composite response and failure modes. The model beams were loaded under scaled test conditions until catastrophic failure. A large deflection beam solution was developed to compare with the static experimental results and to analyze beam failure. Also, the finite element code DYCAST (DYnamic Crash Analysis of STructure) was used to model both the static and impulsive beam response. Static test results indicate that the unidirectional and cross ply beam responses scale as predicted by the model law, even under severe deformations. In general, failure modes were consistent between scale models within a laminate family; however, a significant scale effect was observed in strength. The scale effect in strength which was evident in the static tests was also observed in the dynamic tests. Scaling of load and strain time histories between the scale model beams and the prototypes was excellent for the unidirectional beams, but inconsistent results were obtained for the angle ply, cross ply, and quasi-isotropic beams. Results show that valuable information can be obtained from testing on scale model composite structures, especially in the linear elastic response region. However, due to scaling effects in the strength behavior of composite laminates, caution must be used in extrapolating data taken from a scale model test when that test involves failure of the structure.

Jackson, Karen E.↗

Periodic behaviors in the observed vertical column abundances of atmospheric hydroxyl

OH vertical column abundances measured at Fritz Peak Observatory, Colorado, from 1977 through 1988 reveal semi-annual and annual cycles which are amplitude modulated over the 11-year data base. The modulation of the OH seasonal behavior is in phase with solar activity as described by the sunspot number index. No mechanism for the observed covariance of this OH behavior with solar activity has yet been identified.

Burnett, Elizabeth Beaver↗

Effects of atmospheric transport on column abundances of nitrogen and chlorine compounds in the arctic stratosphere

In the absence of heterogeneous processes, distributions of NO(y), HNO3, Cl(x) and HCl in the polar winter stratosphere should be determined by transport. A model simulating distributions of these species in the arctic for January and February 1989 is developed using observed fields of potential vorticity and potential temperature. Comparison of model results with column measurements from the DC-8 indicates conversion of NO(x) to HNO3, condensation of HNO3, conversion of HCl to CINO3, and conversion of HCl plus CINO3 to an unmeasured species. Heterogeneous processes strongly affect abundances of NO(y) and Cl(x) species in the winter arctic stratosphere.

Yatteau, John H.↗

Observations of columnal recombination in the ionization tracks of energetic heavy nuclei in an argon-methane gas mixture

Measurements of ionization signals resulting from the passage of energetic heavy nuclei through a gas mixture consisting of 95 mol percent Ar plus 5 mol percent CH4, at an absolute pressure of 3 atm are presented. The measurements take place under a uniform electric field perpendicular to the ionization track. The signals were compared to the calculated energy losses, with an assumption of proportionality between energy loss rate and ionization rate. Significant deviations from proportionality are found for energy loss rate grater than about 3000 MeV sq cm/g, while fractional deviations are found to be proportional to the energy loss rate (dE/dx) exp m, where m is equal to about two. These results are attributed to the columnal recombination.

Wiedenbeck, Mark E.↗

OH vertical column abundance - Tropical measurements

Measurements of the vertical column abundance of atmospheric hydroxyl (OH) have been made during the period 1987-1989 at the National Weather Service (NWS) station at Moen, Truk, Federated States of Micronesia (7 deg N, 152 deg E). A total of 384 independent data sets was obtained. Tropical OH abundance levels average about 22 percent above corresponding mid-latitude values, with OH levels during late winter and early spring up to 50 percent above those observed at 40 deg N. Stratospheric wind and temperature data obtained from the daily NWS radiosonde data are examined for correlations with the OH results.

Burnett, Clyde R.↗