Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

GEWEX SRB Release 4: Public Release

The NASA/GEWEX Surface Radiation Budget (SRB) project produces 3-hourly shortwave and longwave surface and top of atmosphere radiative fluxes for the 1983-near present time period. Here we announce the public availability of the new Release 4 Integrated data product (R4-IP). R4-IP uses the newly recalibrated and processed ISCCP HXS product as its primary input for cloud and radiance data, replacing ISCCP DX with a ninefold increase in pixel count (10km instead of 30km). This version retains a 1°x1° resolution but benefits from a much larger number of samples per grid box than the SRB Release 3. ISCCP also provides an atmospheric temperature and moisture dataset known as nnHIRS which we use here, along with Seaflux and Landflux surface and near-surface meteorological parameters constituting an “Integrated Product” for energy and water cycle studies. In addition to the input data improvements, several important algorithm improvements have been made since Release 3. These include recalculated shortwave (SW or solar wavelengths) atmospheric transmissivities and reflectivities yielding a somewhat less transmissive atmosphere. Both SW and LW (longwave or thermal infrared) also include variable aerosol composition and radiative properties, allowing for the use of a detailed aerosol history from the Max Planck Institute Aerosol Climatology (MAC). Both LW and SW algorithms now produce pristine sky fluxes, allowing the aerosol flux effects to be quantified. For SW, ocean albedo and snow/ice albedo are improved from Release 3. Total solar irradiance is now variable, and reduced to an average of 1361 Wm-2. The radiative treatment of ice cloud is improved. For the LW, a climatological monthly varying spectral surface emissivity is added. Here we analyze the new SW SRB datasets, comparing them to the previous Release 3, BSRN and PMEL surface measurements. Validation results show improved agreement compared to Release 3. Comparisons to ERBE and CERES TOA and surface satellite datasets before and after overlap periods show the long-term agreement with radiometric uncertainty. Monthly anomalies at global and zonal regions show very good correlation with the shorter ERBE and CERES flux anomalies linking those to the longer term. The uncertainties are discussed and periods of potential issues in inputs and/or algorithms are identified.

Earth Radiation Budget↗

Validation of statistical uncertainties in subcritical benchmark measurements: Part II – Measured data

Part I of this work presented an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This moments-based approach utilizes time correlations between prompt neutrons detections to assess the system multiplication. Additionally, it presented a validation which utilized simulated data generated using a 0-D point-kinetics Monte Carlo code. In Part II, this same method and validation approach is applied to measured data of a subcritical benchmark experiment. These measurements were performed with a 4.5 kg sphere of alpha-phase weapons grade plutonium reflected by copper and/or polyethylene. Finally, the results of 17 configurations are shown including detailed validation for four of the configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air Traffic Sector Configuration Change Frequency

Several techniques for partitioning airspace have been developed in the literature. The question of whether a region of airspace created by such methods can be used with other days of traffic, and the number of times a different partition is needed during the day is examined in this paper. Both these aspects are examined for the Fort Worth Center airspace sectors. A Mixed Integer Linear Programming method is used with actual air traffic data of ten high-volume low-weather-delay days for creating sectors. Nine solutions were obtained for each two-hour period of the day by partitioning the center airspace into two through 18 sectors in steps of two sectors. Actual track-data were played back with the generated partitions for creating histograms of the traffic-counts. The best partition for each two-hour period was then identified based on the nine traffic-count distributions. Numbers of sectors in such partitions were analyzed to determine the number of times a different configuration is needed during the day. One to three partitions were selected for the 24-hour period, and traffic data from ten days were played back to test if the traffic-counts stayed below the threshold values associated with these partitions. Results show that these partitions are robust and can be used for longer durations than they were designed for

Chatterji, Gano Broto↗

Non-residential Electricity Prices: A Review of Data Sources and Estimation Methods

This paper presents a review of electricity price data sources and estimation methods for non-residential consumers, including a detailed empirical study of tariff-based prices collected as part of Lawrence Berkeley Lab's Tariff Analysis Project (TAP). We compare the TAP data to two other data sources: utility-level annual sales, revenues and consumer counts published by the Energy Information Administration (EIA), and the Typical Bills reports published by the Edison Electric Institute. A brief overview of the types of rate structures included in the TAP database illustrates the often complex relationship between the consumer's energy use and the costs they see on their electricity bills. We provide mathematical definitions of the different types of electricity price that are useful in cost-benefit analysis, construct estimation methods appropriate to each data set, compare the results, and evaluate the relative strengths and weaknesses of each approach. We also examine how price variation is driven by differences in season, region, industry business model, and variables characterizing consumer energy use. Tables of regional price estimates for each data source, based on 2015 data, are included in the Appendix to this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Crop identification and leaf area index calculations with Landsat multitemporal data

Formulas are given to convert land-based vegetative canopy spectral reflectance measurements into Landsat digital counts in the four channels for a clear standard atmosphere. These formulas are shown to predict the curves found by plotting multitemporal Landsat trajectories. With correct interpretation, plots of channel 3 versus channel 4 Landsat data for crops are shown to yield information on both crop identification and crop leaf area index.

Chance, J. E.↗

SU-G-IeP4-02: Application of Changs Attenuation Correction Technique for SPECT Partial Angle Acquisition of Jaszczak Phantom

Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (n = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.

60 APPLIED LIFE SCIENCES↗

Very High Cycle Fatigue Testing of AMS 6308 Steel

Lightweight and reliable gearboxes are required for helicopters and future electrical vertical take-off and landing aircraft. Mechanical gears in these applications experience more than 10 7 million fatigue cycles over their operating life and between maintenance intervals. Fatigue data for gear steels above 10 7 cycles is rare due to the testing time required to reach these cycle counts with traditional methods. In this paper, ultrasonic fatigue testing is used to collect mechanical fatigue data on AMS 6308 steel in the 10 7 to 1010 cycle regime.

Thomas Tallerico↗

Verification Survey Report of the South Waste Tank Farm Training/Test Tower and hazardous Waste Storage Lockers at the West Valley Demonstration Project, West Valley, New York (Final Report)

A team from ORAU's Independent Environmental Assessment and Verification Program performed verification survey activities on the South Test Tower and four Hazardous Waste Storage Lockers. Scan data collected by ORAU determined that both the alpha and alpha-plus-beta activity was representative of radiological background conditions. The count rate distribution showed no outliers that would be indicative of alpha or alpha-plus-beta count rates in excess of background. It is the opinion of ORAU that independent verification data collected support the site's conclusions that the South Tower and Lockers sufficiently meet the site criteria for release to recycle and reuse.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

xxing9703/PAVE

Untargeted metabolomics can detect more than 10 000 peaks in a single LC–MS run. The correspondence between these peaks and metabolites, however, remains unclear. Here, we introduce a Peak Annotation and Verification Engine (PAVE) for annotating untargeted microbial metabolomics data. The workflow involves growing cells in 13C and 15N isotope-labeled media to identify peaks from biological compounds and their carbon and nitrogen atom counts. Improved deisotoping and deadducting are enabled by algorithms that integrate positive mode, negative mode, and labeling data. To distinguish metabolites and their fragments, PAVE experimentally measures the response of each peak to weak in-source collision induced dissociation, which increases the peak intensity for fragments while decreasing it for their parent ions. The molecular formulas of the putative metabolites are then assigned based on database searching using both m/z and C/N atom counts. Application of this procedure to Saccharomyces cerevisiae and Escherichia coli revealed that more than 80% of peaks do not label, i.e., are environmental contaminants. More than 70% of the biological peaks are isotopic variants, adducts, fragments, or mass spectrometry artifacts yielding ∼2000 apparent metabolites across the two organisms. About 650 match to a known metabolite formula based on m/z and C/N atom counts, with 220 assigned structures based on MS/MS and/or retention time to match to authenticated standards. Thus, PAVE enables systematic annotation of LC–MS metabolomics data with only ∼4% of peaks annotated as apparent metabolites.

Xing, Xi↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SWIFT SURVEY OF ACCRETION ONTO STELLAR-MASS BLACK HOLES

We present a systemic analysis of all of the stellar-mass black hole binaries (confirmed and candidate) observed by the Swift observatory up to 2010 June. The broad Swift bandpass enables a trace of disk evolution over an unprecedented range in flux and temperature. The final data sample consists of 476 X-ray spectra containing greater than 100 counts, in the 0.6-10 keV band. This is the largest sample of high-quality CCD spectra of accreting black holes published to date. In addition, strictly simultaneous data at optical/UV wavelengths are available for 255 (54%) of these observations. The data are modeled with a combination of an accretion disk and a hard spectral component. For the hard component we consider both a simple power-law model and a thermal Comptonization model. An accretion disk is detected at greater than the 5{sigma} confidence level in 61% of the observations. Light curves and color-color diagrams are constructed for each system. Hardness-luminosity and disk fraction-luminosity diagrams are constructed and are observed to be consistent with those typically observed by RXTE, noting the sensitivity below 2 keV provided by Swift. The observed spectra have an average luminosity of {approx}1% Eddington, though we are sensitive to accretion disks down to a luminosity of 10{sup -3} L{sub Edd}. Thus, this is also the largest sample of such cool accretion disks studied to date. The accretion disk temperature distribution displays two peaks consistent with the classical hard and soft spectral states, with a smaller number of disks distributed between these. The distribution of inner disk radii is observed to be continuous regardless of which model is used to fit the hard continua. There is no evidence for large-scale truncation of the accretion disk in the hard state (at least for L{sub x} {approx}> 10{sup -3} L{sub Edd}), with all of the accretion disks having radii {approx}< 40 R{sub g} . Plots of the accretion disk inner radius versus hardness ratio reveal the disk radius to be decreasing as the spectrum hardens, i.e., enters the hard state. This is in contrast to expectations from the standard disk truncation paradigm and points toward a contribution from spectral hardening. The availability of simultaneous X-ray and optical/UV data for a subset of observations facilitates a critical examination of the role of disk irradiation via a modified disk model with a variable emissivity profile (i.e., T(r){proportional_to}r {sup -p}). The broadband spectra (X-ray-optical/UV) reveal irradiation of the accretion disk to be an important effect at all luminosities sampled herein, i.e., p {approx}< 0.75 for luminosities {approx}> 10{sup -3} L{sub Edd}. The accretion disk is found to dominate the UV emission irrespective of the assumed hard spectral component. Overall, we find the broadband soft-state spectra to be consistent with an irradiated accretion disk plus a corona, but we are unable to make conclusive statements regarding the nature of the hard-state accretion flow (e.g., ADAF/corona versus jet). Finally, the Swift data reveal a relation between the flux emitted by the accretion disk and that emitted by the corona, for this sample of stellar-mass black holes, that is found to be in broad agreement with the observed disk-corona relationship in Seyfert galaxies, suggesting a scale invariant coupling between the accretion disk and the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

The galaxy distribution and the large-scale structure of the universe

Data related to the large-scale galaxy distribution are discussed. The galaxy counts of Shane-Wirtanen (1967) are analyzed; the effects of residual systematic errors on the galaxy distribution measurements are considered. The analysis reveals that the Shane-Wirtanen data are not applicable to the study of large-scale structure. A model which is capable of measuring galaxy correlation functions on scales greater than about 10 Mpc is evaluated.

Geller, M. J.↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Outcomes of Chemoradiotherapy With 5-Fluorouracil and Mitomycin C for Anal Cancer in Immunocompetent Versus Immunodeficient Patients

Purpose: Information is limited as to how we should treat invasive anal squamous cell carcinoma (SCC) in patients with chronic immunosuppression, since the majority of clinical studies to date have excluded such patients. The objective of this study is to compare treatment outcomes in immunocompetent (IC) versus immunodeficient (ID) patients with invasive anal SCC treated similarly with combined modality therapy. Methods and Materials: Between January 1999 and March 2007, a total of 36 consecutive IC and ID patients received concurrent chemoradiotherapy using three-dimensional conformal radiotherapy with infusional 5-fluorouracil and mitomycin C. The IC and ID groups consisted of 19 and 17 patients, respectively, with 14 human immunodeficiency virus-positive (HIV+) and 3 post-solid organ transplant ID patients. There were no significant differences in tumor size, T stage, N stage, chemotherapy doses, or radiation doses between the two groups. Results: With a median follow-up of 3.1 years, no differences were found in overall survival, disease-specific survival, and colostomy-free survival. Three-year overall survival was 83.6% (95% CI = 68.2-100) and 91.7% (95% CI = 77.3-100) in the IC and ID groups, respectively. In addition, there were no differences in acute and late toxicity profiles between the two groups. In the human immunodeficiency virus-positive patients, Cox modeling showed no difference in overall survival by pretreatment CD4 counts (hazard ratio = 0.994, 95% CI = 0.98-1.01). No correlation was found between CD4 counts and the degree of acute toxicities. Conclusion: Our data suggest that standard combined modality therapy with three-dimensional conformal radiotherapy and 5-fluorouracil plus mitomycin C is as safe and effective for ID patients as for IC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Fluorescence Microscopy To Determine Molecular Occupancy of Phospholipid Vesicles

Encapsulation of molecules in phospholipid vesicles provides unique opportunities to study chemical reactions in small volumes as well as the behavior of individual proteins, enzymes, and ribozymes in a confined region without requiring a tether to immobilize the molecule to a surface. These experiments generally depend on generating a predictable loading of vesicles with small numbers of target molecules and thus raise a significant measurement challenge, namely, to quantify molecular occupancy of vesicles at the single-molecule level. In this work, we describe an imaging experiment to measure the time-dependent fluorescence from individual dye molecules encapsulated in ~130 nm vesicles that are adhered to a glass surface. For determining a fit of the molecular occupancy data to a Poisson model, it is critical to count empty vesicles in the population since these dominate the sample when the mean occupancy is small, λ ≤ ~1. Counting empty vesicles was accomplished by subsequently labeling all the vesicles with a lipophilic dye and reimaging the sample. By counting both the empty vesicles and those containing fluors, and quantifying the number of fluors present, we demonstrate a self-consistent Poisson distribution of molecular occupancy for well-solvated molecules, as well as anomalies due to aggregation of dye, which can arise even at very low solution concentrations. Here, by observation of many vesicles in parallel in an image, this approach provides quantitative information about the distribution of molecular occupancy in a population of vesicles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RINGS AND RADIAL WAVES IN THE DISK OF THE MILKY WAY

Here, we show that in the anticenter region, between Galactic longitudes of 110° < l < 229°, there is an oscillating asymmetry in the main-sequence star counts on either side of the Galactic plane using data from the Sloan Digital Sky Survey. This asymmetry oscillates from more stars in the north at distances of about 2 kpc from the Sun to more stars in the south at 4–6 kpc from the Sun to more stars in the north at distances of 8–10 kpc from the Sun. We also see evidence that there are more stars in the south at distances of 12–16 kpc from the Sun. The three more distant asymmetries form roughly concentric rings around the Galactic center, opening in the direction of the Milky Way's spiral arms. The northern ring, 9 kpc from the Sun, is easily identified with the previously discovered Monoceros Ring. Parts of the southern ring at 14 kpc from the Sun (which we call the TriAnd Ring) have previously been identified as related to the Monoceros Ring, and others have been called the Triangulum Andromeda Overdensity. The two nearer oscillations are approximated by a toy model in which the disk plane is offset by the order of 100 pc up and then down at different radii. We also show that the disk is not azimuthally symmetric around the Galactic anticenter and that there could be a correspondence between our observed oscillations and the spiral structure of the Galaxy. Lastly, our observations suggest that the TriAnd and Monoceros Rings (which extend to at least 25 kpc from the Galactic center) are primarily the result of disk oscillations.

79 ASTRONOMY AND ASTROPHYSICS↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗