Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Monolithic single GaN nanowire laser with photonic crystal microcavity on silicon

Optically pumped lasing at room temperature in a silicon based monolithic single GaN nanowire with a two-dimensional photonic crystal microcavity is demonstrated. Catalyst-free nanowires with low density ({approx}10{sup 8} cm{sup -2}) are grown on Si by plasma-assisted molecular beam epitaxy. High resolution transmission electron microscopy images reveal that the nanowires are of wurtzite structure and they have no observable defects. A single nanowire laser fabricated on Si is characterized by a lasing transition at {lambda}=371.3 nm with a linewidth of 0.55 nm. The threshold is observed at a pump power density of {approx}120 kW/cm{sup 2} and the spontaneous emission factor {beta} is estimated to be 0.08.

74 ATOMIC AND MOLECULAR PHYSICS↗

Smooth cubic commensurate oxides on gallium nitride

Smooth, commensurate alloys of 〈111〉-oriented Mg{sub 0.52}Ca{sub 0.48}O (MCO) thin films are demonstrated on Ga-polar, c+ [0001]-oriented GaN by surfactant-assisted molecular beam epitaxy and pulsed laser deposition. These are unique examples of coherent cubic oxide|nitride interfaces with structural and morphological perfection. Metal-insulator-semiconductor capacitor structures were fabricated on n-type GaN. A comparison of leakage current density for conventional and surfactant-assisted growth reveals a nearly 100× reduction in leakage current density for the surfactant-assisted samples. HAADF-STEM images of the MCO|GaN interface show commensurate alignment of atomic planes with minimal defects due to lattice mismatch. STEM and DFT calculations show that GaN c/2 steps create incoherent boundaries in MCO over layers which manifest as two in-plane rotations and determine consequently the density of structural defects in otherwise coherent MCO. This new understanding of interfacial steps between HCP and FCC crystals identifies the steps needed to create globally defect-free heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Copper intercalation at the interface of graphene and Ir(111) studied by scanning tunneling microscopy

We report on the intercalation of a submonolayer of copper at 775 K underneath graphene epitaxially grown on Ir(111) studied by means of low energy electron diffraction (LEED) and scanning tunneling microscopy (STM) at 77 K. Nucleation and growth dynamics of Cu below graphene have been investigated, and, most importantly, the intercalation mechanism has been identified. First, LEED patterns reveal the pseudomorphic growth of Cu on Ir under the topmost graphene layer resulting in a large Cu in-plane lattice parameter expansion of about 6% compared to Cu(111). Second, large-scale STM topographs as a function of Cu coverage show that Cu diffusion on Ir below graphene exhibits a low energy barrier resulting in Cu accumulation at Ir step edges. As a result, the graphene sheet undergoes a strong edges reshaping. Finally, atomically-resolved STM images reveal a damaged graphene sheet at the atomic scale after metal intercalation. Point defects in graphene were shown to be carbon vacancies. According to these results, a Cu penetration path beneath graphene is proposed to occur via metal aided defect formation with no or poor self healing of the graphene sheet. This work illustrates the fact that Cu intercalation is harmful for graphene grown on Ir(111) at the atomic scale.

36 MATERIALS SCIENCE↗

Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert–Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mind the gap: Bridging the divide between AI aspirations and the reality of autonomous microscopy

What does materials science look like in the “Age of Artificial Intelligence?” Each material’s domain—synthesis, characterization, and modeling—has a different answer to this question, motivated by unique challenges and constraints. This work focuses on the tremendous potential of autonomous characterization within electron microscopy. We present our recent advancements in developing domain-aware, multimodal models for microscopy analysis capable of describing complex atomic systems. We then address the critical gap between the theoretical promise of autonomous microscopy and its current practical limitations, showcasing recent successes while highlighting the necessary developments to achieve robust, real-world autonomy.

2D materials↗

Summaries of FY12 LANL Experimental Campaigns at the OMEGA Laser Facility

In FY 2012, Los Alamos National Laboratory (LANL) executed 244 total shots on OMEGA. LANL experiments contributed to the National Ignition (NIC) campaign in the following ways: • Measured the x-ray ablative Richtmyer-Meshkov growth of isolated defects on plastic ablators, • Studied branching ratios in DT fusion plasmas, and • Continued neutron imaging and radchem scintillator development for NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Crystal Backlighter Imager JGBuscho Comprehensive Report 2019

The National Ignition Facility (NIF) is a system of 192 lasers indirectly pointed at a target roughly the size of a millimeter. This target is held at the center of a vacuum chamber 30 feet in diameter. Diagnostics to understand the laser implosion and interaction of the target are inserted into the target chamber during laser shots on Diagnostic Insertion Manipulators (DIMs). Diagnostics are attached to these DIMs as complex assemblies known as snouts. The Crystal Backlighter Imager (CBI) is a snout used to radiograph the capsule implosion. The x-ray radiography of the imploding targets has been used in the past at the NIF with pinhole imaging. A limitation of the pinhole imaging systems is the radiograph becomes overwhelmed with self-emission and key features of the implosion are not visible late in time during the implosion. CBI implements a spherically bent crystal matched to a backlighter atomic line. By doing so, the backlighter atomic line can dominate the self-emission thus allowing the crystals narrow bandwidth to image late in time radiographs. This ability allows for visualizing the capsule structure and defects.

42 ENGINEERING↗

Analysis of defect structure in silicon. Silicon sheet growth development for the large area silicon sheet task of the Low-Cost Solar array Project

One hundred ninety-three silicon sheet samples, approximately 880 square centimeters, were analyzed for twin boundary density, dislocation pit density, and grain boundary length. One hundred fifteen of these samples were manufactured by a heat exchanger method, thirty-eight by edge defined film fed growth, twenty-three by the silicon on ceramics process, and ten by the dendritic web process. Seven solar cells were also step-etched to determine the internal defect distribution on these samples. Procedures were developed or the quantitative characterization of structural defects such as dislocation pits, precipitates, twin & grain boundaries using a QTM 720 quantitative image analyzing system interfaced with a PDP 11/03 mini computer. Characterization of the grain boundary length per unit area for polycrystalline samples was done by using the intercept method on an Olympus HBM Microscope.

Natesh, R.↗

New optical approaches to the quantitative characterization of crystal growth, segregation and defect formation

Elemental and compound semiconductors were characterized using new optical approach based on NIR microscopy in conjunction with computational image analysis and contrast enhancement. The approach made it possible to perform a quantitative microsegregation analysis of GaAs and InP. NIR dark file illumination in transmission mode makes it possible to detect submicron precipitates in semiinsulating GaAs.

Carlson, D. J.↗

Vision Screening

The Visi Screen OSS-C, marketed by Vision Research Corporation, incorporates image processing technology originally developed by Marshall Space Flight Center. Its advantage in eye screening is speed. Because it requires no response from a subject, it can be used to detect eye problems in very young children. An electronic flash from a 35 millimeter camera sends light into a child's eyes, which is reflected back to the camera lens. The photorefractor then analyzes the retinal reflexes generated and produces an image of the child's eyes, which enables a trained observer to identify any defects. The device is used by pediatricians, day care centers and civic organizations that concentrate on children with special needs.

Source record↗

Automation of the Image Analysis for Thermographic Inspection

Several data processing procedures for the pulse thermal inspection require preliminary determination of an unflawed region. Typically, an initial analysis of the thermal images is performed by an operator to determine the locations of unflawed and the defective areas. In the present work an algorithm is developed for automatically determining a reference point corresponding to an unflawed region. Results are obtained for defects which are arbitrarily located in the inspection region. A comparison is presented of the distributions of derived values with right and wrong localization of the reference point. Different algorithms of automatic determination of the reference point are compared.

Plotnikov, Yuri A.↗

Confirmation of the Dominant Defect Mechanism in Amorphous In-Zn-O Through the Application of In Situ Brouwer Analysis

The dominant point defect mechanism of amorphous (a-) indium zinc oxide (IZO) was probed through in situ electrical characterization of sputtered a-IZO thin films in response to changes in oxygen partial pressure (pO2) at 300 degrees C. The results yielded a power law dependence of conductivity (s) versus pOinline image of ~-1/6. This experimental method, known as Brouwer analysis, confirms doubly-charged oxygen vacancies as the dominant defect species in a-IZO. The success of this study suggests that Brouwer analysis is a viable method for studying the defect mechanisms of amorphous oxides.

14 SOLAR ENERGY↗

Large area QNDE inspection for airframe integrity

Quantitative Nondestructive Evaluation (QNDE) technology is being developed to provide new options for cost effective inspection of airframes. An R&D effort based on five NDE technologies is addressing questions of structural bonding assessment, corrosion detection, multisite damage detection, and fatigue characterization. The research/applications are being conducted by prioritized focussing and staging of the following technologies: (1) thermal NDE; (2) ultrasonic NDE; (3) coherent optical NDE; (4) magnetic imaging NDE; and (5) radiographic NDE. The focus here is on the most recent applications of thermal NDE technology to large area inspection of lap-joint and stiffener bonds. The approach is based on pulsed radiant heating of the airframe and measurement of the surface temperature of the structure with an infrared imager. Several advantages of the technique are that it is noncontacting, inspects one square meter area in a period of less than 2 minutes and has no difficulty inspecting typical curvatures of the fuselage. Numerical models of heat flow in these geometries are used to determine appropriate techniques for reduction of the infrared images, thereby delineating regions of disbonds. These models are also used to determine the optimum heating and measurement times for maximizing the contrast between bonded and unbonded structures. Good agreement is found between these results and experimental measurements, and a comparison of the two are presented. Also presented are results of measurements on samples with fabricated defects which show the technique is able to clearly indicate regions of disbonds. Measurements on an airframe also clearly image subsurface structure.

Winfree, William P.↗

High-resolution virtual Frisch grid gamma-ray detectors based on as-grown CdZnTeSe with reduced defects

X- and gamma-ray detectors arequickly becoming essential tools for science and technology in various fields. These detectors offer broad applications such as homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. All these applications necessitate high-resolution detectors operable at room temperature and available at a reasonable cost. CdZnTe (CZT) is the material of choice for this purpose; however, the material still suffers from intrinsic defects such as highly decorated subgrain boundary networks and a high concentration of secondary phases. These defects not only hinder the charge transport but also create a spatial inhomogeneity in the charge transport properties, subsequently causing substantial degradation in detector response particularly for relatively thick (>1 cm) detectors. Some of the material deficiencies suffered by CZT have been addressed by adding selenium into the CZT matrix. Selenium was found to be very effective in producing material that is principally free from a subgrain boundary network with the occasional appearance of subgrain boundaries with reduced secondary phases decorating these boundaries. The resulting quaternary compound CdZnTeSe (CZTS) reflected excellent material quality mitigating some major deficiencies suffered by CZT. Virtual Frisch grid detectors were fabricated from the as-grown CZTS ingots, and they demonstrated high resolution spectroscopic grade. The excellent CZTS material contained very low defects and was found to potentially increase the yield of high-quality detectors as compared to CZT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A short story of imaging and spectroscopy of two-dimensional materials by scanning transmission electron microscopy

Here we present a short historical account of when single adatom impurities where first identified in two-dimensional materials by scanning transmission electron microscopy (STEM). We also present a study of the graphene low-loss (below 50 eV) response as a function of number of layers using electron energy-loss spectroscopy (EELS). The study shows that as few as three layers of graphene behave as bulk graphite for losses above 10 eV We also show examples of how point and extended defects can easily be resolved and structural dynamics can be readily capture by using aberration-corrected STEM imaging. Lastly, we show that the new generation of monochromators has opened up possibilities to explore new physics with an electron microscope. All these capabilities were enabled by the development of spherical aberration correctors and monochromators, where Ondrej Krivanek has played a key role.

2D materials↗

Prolonged dipyridamole administration reduces myocardial perfusion defects in experimental chronic Chagas cardiomyopathy

Background: Myocardial perfusion defects (MPD) due to coronary microvascular dysfunction is frequent in chronic Chagas cardiomyopathy (CCC) and may be involved with development of myocardial damage. We investigated whether MPD precedes left ventricular systolic dysfunction and tested the hypothesis that prolonged use of dipyridamole (DIPY) could reduce MPD in an experimental model of CCC in hamsters. Methods and results: We investigated female hamsters 6-months after T. cruzi infection (baseline condition) and control animals, divided into T. cruzi-infected animals treated with DIPY (CH + DIPY) or placebo (CH + PLB); and uninfected animals treated with DIPY (CO + DIPY) or placebo (CO + PLB). The animals were submitted to echocardiogram and rest SPECT-Sestamibi-Tc99m myocardial perfusion scintigraphy. Next, the animals were treated with DIPY (4 mg/kg bid, intraperitoneal) or saline for 30 days, and reevaluated with the same imaging methods. At baseline, the CH + PLB and CH + DIPY groups showed larger areas of perfusion defect (13.2 ± 13.2% and 17.3 ± 13.2%, respectively) compared with CO + PLB and CO + DIPY (3.8 ± 2.2% e 3.5 ± 2.7%, respectively), P < .05. After treatment, we observed: reduction of perfusion defects only in the CH + DIPY group (17.3 ± 13.2% to 6.8 ± 7.6%, P = .001) and reduction of LVEF in CH + DIPY and CH + PLB groups (from 65.3 ± 9.0% to 53.6 ± 6.9% and from 69.3 ± 5.0% to 54.4 ± 8.6%, respectively, P < .001). Quantitative histology revealed greater extents of inflammation and interstitial fibrosis in both Chagas groups, compared with control group (P < .001), but no difference between Chagas groups (P > .05). Conclusions: The prolonged use of DIPY in this experimental model of CCC has reduced the rest myocardial perfusion defects, supporting the notion that those areas correspond to viable hypoperfused myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy

Background: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). Methods: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. Results: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC–SC–RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC–RC. Conclusions: Our results suggest that studies reconstructed by OS-EM with AC–SC–RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect-mediated ripening of core-shell nanostructures

Abstract Understanding nanostructure ripening mechanisms is desirable for gaining insight on the growth and potential applications of nanoscale materials. However, the atomic pathways of nanostructure ripening in solution have rarely been observed directly. Here, we report defect-mediated ripening of Cd-CdCl 2 core-shell nanoparticles (CSN) revealed by in-situ atomic resolution imaging with liquid cell transmission electron microscopy. We find that ripening is initiated by dissolution of the nanoparticle with an incomplete CdCl 2 shell, and that the areas of the Cd core that are exposed to the solution are etched first. The growth of the other nanoparticles is achieved by generating crack defects in the shell, followed by ion diffusion through the cracks. Subsequent healing of crack defects leads to a highly crystalline CSN. The formation and annihilation of crack defects in the CdCl 2 shell, accompanied by disordering and crystallization of the shell structure, mediate the ripening of Cd-CdCl 2 CSN in the solution.

36 MATERIALS SCIENCE↗