Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SU-G-IeP2-04: Dosimetric Accuracy of a Monte Carlo-Based Tool for Cone-Beam CT Organ Dose Calculation: Validation Against OSL and XRQA2 Film Measurements

Purpose: The intensive use of Cone-Beam Computed Tomography (CBCT) during radiotherapy treatments raise some questions about the dose to healthy tissues delivered during image acquisitions. We hence developed a Monte Carlo (MC)-based tool to predict doses to organs delivered by the Elekta XVI kV-CBCT. This work aims at assessing the dosimetric accuracy of the MC tool, in all tissue types. Methods: The kV-CBCT MC model was developed using the PENELOPE code. The beam properties were validated against measured lateral and depth dose profiles in water, and energy spectra measured with a CdTe detector. The CBCT simulator accuracy then required verification in clinical conditions. For this, we compared calculated and experimental dose values obtained with OSL nanoDots and XRQA2 films inserted in CIRS anthropomorphic phantoms (male, female, and 5-year old child). Measurements were performed at different locations, including bone and lung structures, and for several acquisition protocols: lung, head-and-neck, and pelvis. OSLs and film measurements were corrected when possible for energy dependence, by taking into account for spectral variations between calibration and measurement conditions. Results: Comparisons between measured and MC dose values are summarized in table 1. A mean difference of 8.6% was achieved for OSLs when the energy correction was applied, and 89.3% of the 84 dose points were within uncertainty intervals, including those in bones and lungs. Results with XRQA2 are not as good, because incomplete information about electronic equilibrium in film layers hampered the application of a simple energy correction procedure. Furthermore, measured and calculated doses (Fig.1) are in agreement with the literature. Conclusion: The MC-based tool developed was validated with an extensive set of measurements, and enables the organ dose calculation with accuracy. It can now be used to compute and report doses to organs for clinical cases, and also to drive strategies to optimize imaging protocols.

60 APPLIED LIFE SCIENCES↗

Comparison of Biological Effectiveness of Carbon-Ion Beams in Japan and Germany

Purpose: To compare the biological effectiveness of 290 MeV/amu carbon-ion beams in Chiba, Japan and in Darmstadt, Germany, given that different methods for beam delivery are used for each. Methods and Materials: Murine small intestine and human salivary gland tumor (HSG) cells exponentially growing in vitro were irradiated with 6-cm width of spread-out Bragg peaks (SOBPs) adjusted to achieve nearly identical beam depth-dose profiles at the Heavy-Ion Medical Accelerator in Chiba, and the SchwerIonen Synchrotron in Darmstadt. Cell kill efficiencies of carbon ions were measured by colony formation for HSG cells and jejunum crypts survival in mice. Cobalt-60 {gamma} rays were used as the reference radiation. Isoeffective doses at given survivals were used for relative biological effectiveness (RBE) calculations and interinstitutional comparisons. Results: Isoeffective D{sub 10} doses (mean {+-} standard deviation) of HSG cells ranged from 2.37 {+-} 0.14 Gy to 3.47 {+-} 0.19 Gy for Chiba and from 2.31 {+-} 0.11 Gy to 3.66 {+-} 0.17 Gy for Darmstadt. Isoeffective D{sub 10} doses of gut crypts after single doses ranged from 8.25 {+-} 0.17 Gy to 10.32 {+-} 0.14 Gy for Chiba and from 8.27 {+-} 0.10 Gy to 10.27 {+-} 0.27 Gy for Darmstadt, whereas isoeffective D{sub 30} doses after three fractionated doses were 9.89 {+-} 0.17 Gy through 13.70 {+-} 0.54 Gy and 10.14 {+-} 0.20 Gy through 13.30 {+-} 0.41 Gy for Chiba and Darmstadt, respectively. Overall difference of RBE between the two facilities was 0-5% or 3-7% for gut crypt survival or HSG cell kill, respectively. Conclusion: The carbon-ion beams at the National Institute of Radiological Sciences in Chiba, Japan and the Gesellschaft fuer Schwerionenforschung in Darmstadt, Germany are biologically identical after single and daily fractionated irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of the Local Effect Model for the Prediction of Biologic Effects of Carbon Ion Beams In Vitro and In Vivo

Purpose: To analyze the accuracy of relative biologic effectiveness (RBE) values for treatment planning in carbon ion radiotherapy based on the local effect model (LEM) and to discuss the implications on the clinically relevant depth dose profiles. Methods and Materials: Predictions of the LEM are compared with a broad panel of experimental data in vitro and to the tolerance of the rat spinal cord in vivo. To improve the accuracy of the LEM, the description of track structure is modified by taking into account a velocity-dependent extension of the inner part of the track. Results: The original version of the LEM (LEM I) underestimates the therapeutic ratio of carbon ions (i.e., the ratio of RBE in the Bragg peak region as compared with the RBE in the entrance channel). Although significantly reduced, the cluster extension of the LEM (LEM II) still shows the same tendency. Implementation of the modified track structure (LEM III) almost completely compensates these systematic deviations, and predictions of RBE by LEM III for high and low energetic carbon ions show good agreement for a wide panel of different cell lines, as well as for the tolerance of the rat spinal cord. As a consequence, the expected RBE in the normal tissue surrounding the tumor becomes significantly lower than estimated with the LEM in its original version (LEM I). Conclusions: The modified track structure description represents an empiric approach to improve the accuracy of the LEM for treatment planning. This will be particularly useful for further optimization of carbon ion therapy in general and with respect to comparison with other treatment modalities, such as protons or intensity-modulated radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO{sub 4} and biodegradable polymer for proton therapy

Purpose: The aim of this study is to investigate the use of mixture of BaSO{sub 4} and biodegradable polymer as an injectable nonmetallic fiducial marker to reduce artifacts in x-ray images, decrease the absorbed dose distortion in proton therapy, and replace permanent metal markers. Methods: Two samples were made with 90 wt. % polymer phosphate buffer saline (PBS) and 10 wt. % BaSO{sub 4} (B1) or 20 wt. % BaSO{sub 4} (B2). Two animal models (mice and rats) were used. To test the injectability and in vivo gelation, a volume of 200 μl at a pH 5.8 were injected into the Sprague-Dawley rats. After sacrificing the rats over time, the authors checked the gel morphology. Detectability of the markers in the x-ray images was tested for two sizes (diameters of 1 and 2 mm) for B1 and B2. Four samples were injected into BALB/C mice. The polymer mixed with BaSO{sub 4} transform from SOL at 20 °C with a pH of 6.0 to GEL in the living body at 37 °C with a pH of 7.4, so the size of the fiducial marker could be controlled by adjusting the injected volume. The detectability of the BaSO{sub 4} marker was measured in x-ray images of cone beam CT (CBCT), on-board imager [anterior–posterior (AP), lateral], and fluoroscopy (AP, lateral) using a Novalis-TX (Varian Medical Systems, Palo Alto, CA) repeatedly over 4 months. The volume, HU, and artifacts for the markers were measured in the CBCT images. Artifacts were compared to those of gold marker by analyzing the HU distribution. The dose distortion in proton therapy was computed by using a Monte Carlo (MC) code. A cylindrical shaped marker (diameter: 1 or 2 mm, length: 3 mm) made of gold, stainless-steel [304], titanium, and 20 wt. % BaSO{sub 4} was positioned at the center of the spread-out Bragg peak (SOBP) in parallel or perpendicular to the beam entrance. The dose distortion was measured on the depth dose profile across the markers. Results: Transformation to GEL and the biodegradation were verified. All BaSO{sub 4} markers could be detected in the CBCT. In the OBI and fluoroscopy images, all markers visible in the AP, but only B2(2 mm) could be identified in the lateral images. Changes of BaSO{sub 4} position were not detected in vivo (mice). The volume of the markers decreased by up to 65% and the HU increased by 22%, on average. The mean HU values around the B1, B2, and gold markers were 121.30 [standard deviation (SD): 54.86], 126.31 (SD: 62.13), and 1070.7 (SD: 235.16), respectively. The MC-simulated dose distortion for the BaSO{sub 4} markers was less than that of the commercially used markers. The dose reduction due to the gold marker was largest (15.05%) followed by stainless steel (7.92%) and titanium (6.92%). Dose reduction by B2 (2 mm) was 4.75% and 0.53% in parallel and perpendicular orientations, respectively. Conclusions: BaSO{sub 4} mixed with PBS is a good contrast agent in biodegradable polymer marker because of minimal artifacts in x-ray images and minimal dose reduction in proton therapy. The flexibility of the size is considered to be an advantage of this material over solid type fiducials.

60 APPLIED LIFE SCIENCES↗

WE-D-BRF-04: Experimental Investigations On Ion Radiography with Beam Scanning Using a Range Telescope

Purpose: Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable properties allow superior tumordose conformality, but introduce sensitivity to range uncertainties. Hence, imaging techniques play an increasingly important role to support the treatment planning and the in-vivo monitoring of the actual ion beam treatment. Methods: This work presents the experimental investigations carried out to address the feasibility of ion transmission imaging at the Heidelberg Ion Therapy center using an active raster scanning beam delivery system and a prototype range telescope set-up based on a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with 3 mm absorber plates of PMMA. Results: An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed and results will be presented. A data processing method to increase the range resolution (MIRR) of the PPIC stack was developed. In this approach, the position of the maximum of the Bragg curve is deduced from the ratio of measured signals in adjacent PPIC channels. MIRR evaluation is based on Bragg curves obtained from Monte Carlo simulations and validated with experimental data acquired with the PPIC stack using ion beams. MIRR was applied to the carbon ion radiography of an anthropomorphic Alderson head phantom yielding a resolution of 0.8 mm water equivalent thickness (WET) compared to the nominal value of 3.495 mm WET given by the thickness of the absorber slabs in the PPIC stack. An absolute comparison of the Alderson phantom carbon ion transmitted image with an X-ray digitally reconstructed radiography, both converted into WET, will also be shown. Conclusion: The obtained results are very promising and motivate further developments of the system towards an eventual clinical use.This work is supported by the German Research Foundation and the German Academic Exchange Service. This work is supported by the German Research Foundation (DFG) and the German Academic Exchange Service (DAAD)

07 ISOTOPE AND RADIATION SOURCES↗

Interface Aspects in All‐Solid‐State Li‐Based Batteries Reviewed

Abstract Extensive efforts have been made to improve the Li‐ionic conductivity of solid electrolytes (SE) for developing promising all‐solid‐state Li‐based batteries (ASSB). Recent studies suggest that minimizing the existing interface problems is even more important than maximizing the conductivity of SE. Interfaces are essential in ASSB, and their properties significantly influence the battery performance. Interface problems, arising from both physical and (electro)chemical material properties, can significantly inhibit the transport of electrons and Li‐ions in ASSB. Consequently, interface problems may result in interlayer formation, high impedances, immobilization of moveable Li‐ions, loss of active host sites available to accommodate Li‐ions, and Li‐dendrite formation, all causing significant storage capacity losses and ultimately battery failures. The characteristic differences of interfaces between liquid‐ and solid‐type Li‐based batteries are presented here. Interface types, interlayer origin, physical and chemical structures, properties, time evolution, complex interrelations between various factors, and promising interfacial tailoring approaches are reviewed. Furthermore, recent advances in the interface‐sensitive or depth‐resolved analytical tools that can provide mechanistic insights into the interlayer formation and strategies to tailor the interlayer formation, composition, and properties are discussed.

25 ENERGY STORAGE↗

Calibration, measurement, and characterization of soil moisture dynamics in a central Amazonian tropical forest

Soil moisture plays a key role in hydrological, biogeochemical, and energy budgets of terrestrial ecosystems. Accurate soil moisture measurements in remote ecosystems such as the Amazon are difficult and limited because of logistical constraints. Time domain reflectometry (TDR) sensors are widely used to monitor soil moisture and require calibration to convert the TDR's dielectric permittivity measurement (K a ) to volumetric water content (θ v ). In this study, our objectives were to develop a field-based calibration of TDR sensors in an old-growth upland forest in the central Amazon, to evaluate the performance of the calibration, and then to apply the calibration to determine the dynamics of soil moisture content within a 14.2 -m-deep vertical soil profile. Depth-specific TDR calibration using local soils in a controlled laboratory setting yielded a novel K a –θ v third-degree polynomial calibration. The sensors were later installed to their specific calibration depth in a 14.2-m pit. The widely used K a –θ v relationship (Topp model) underestimated the site-specific θ v by 22–42%, indicating significant error in the model when applied to these well-structured, clay-rich tropical forest soils. The calibrated wet- and dry-season θ v data showed a variety of depth and temporal variations highlighting the importance of soil textural differentiation, root uptake depths, as well as event to seasonal precipitation effects. Data such as these are greatly needed for improving our understanding of ecohydrological processes within tropical forests and for improving models of these systems in the face of changing environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Fatigue and Fracture Behavior of Induction-Hardened and Superimposed Mechanically Post-treated Steel Surface Layers

This paper focuses on the effect of induction hardening and superimposed stroke peening, as mechanical post-treatment, on the fatigue and fracture behavior of gas engine 50CrMo4 steel crankshafts. Comprehensive analysis in regard to local microstructure, hardness and residual stress profile in depth is performed to examine the local characteristics of the investigated crankshafts and the representative notched round specimens. An evaluation of the equivalent von Mises residual stress condition in depth demonstrates an increase by over 70% of the average compressive residual stress state due to the superimposed stroke peening compared to the induction-hardened condition. Rotating bending fatigue tests reveal that the additional stroke-peening process elevates the high-cycle fatigue strength of the induction-hardened surface layer by 20%, which validates the beneficial effect of the enhanced compressive residual stress state. An extensive fracture surface analysis presents the position of crack initiation for each investigated manufacturing condition indicating that the failure origin preferably starts at the surface for higher load levels. On the contrary, the crack initiation shifts beneath the hardened layer in case of lower load levels leading to subsurface failure origin.

36 MATERIALS SCIENCE↗

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were −0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and −0.4 ± 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Transmission Electron Microscopy Study of the Effect of Interfaces on Bubble Formation in He-Implanted Cu-Nb Multilayers

Magnetron sputtered thin films of Cu, Nb, and Cu-Nb multilayers with 2.5 and 5 nm nominal layer thickness were deposited on Si and implanted with 4He+ and 3He+ ions. Secondary ion mass spectroscopy and nuclear reaction analysis, respectively, were used to measure the 4He+ and 3He+ concentration profile with depth inside the films. Cross-sectional transmission electron microscopy was used to characterize the helium bubbles. Analysis of the contrast from helium bubbles in defocused transmission electron microscope images showed a minimum bubble diameter of 1.25 nm. While pure Cu and Nb films showed bubble contrast over the entire range of helium implantation, the multilayers exhibited bubbles only above a critical He concentration that increased almost linearly with decreasing layer thickness. The work shows that large amounts of helium can be trapped at incoherent interfaces in the form of stable, nanometer-size bubbles.

36 MATERIALS SCIENCE↗

Valence Effects of Fe Impurity for Recovered LiNi 0.6 Co 0.2 Mn 0.2 O 2 Cathode Materials

Iron impurities are generally included in the obtained leaching liquor solution during the hydrometallurgical recycling method of spent lithium-ion batteries (LIBs) due to the usage of iron in battery casings and machinery parts of recycling equipment, which would definitely affect the physical and electrochemical features of the recovered active materials. In this paper, the effects of iron impurity with different valence states (Fe 2+ and Fe 3+ ) and gradient concentrations (0.2, 1.0, and 5.0 at. %) for the obtained LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) cathodes are fully studied. It is found that Fe3+ impurity could easily lower the tap density and average size of NCM622 particles and even introduce some impurity phases in the NCM622 structure at high concentration (5.0 at. %), leading to much lower specific capacity, worse rate capability, and cycling performance of the Fe 3+ -based NCM622 cathode. On contrast, with certain concentrations of Fe 2+ impurity (0.2 and 1.0 at. %), the NCM622 cathode material exhibits comparable and much better electrochemical properties compared with the virgin NCM622 materials. Based on these results, the valence of Fe impurity should be considered and controlled as well as its concentration during the recycling process design for spent LIBs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Alkali-Metal Cations in Electronic Structure and Halide Segregation of Hybrid Perovskites

The ability to control or prevent phase segregation in perovskites is crucial to realizing stable and tunable mixed-halide optoelectronic devices. Here, we systematically examine the impact of alkali-metal-cation (Cs + and K + ) concentration on the band structure, chemical composition, phase segregation, and polycrystalline microstructure on formamidinium-dominated mixed-halide mixed-cation perovskite films. It was found that the incorporation of Cs + and K + cations decreases the work function and the core levels of all components shift toward higher binding energy consistent with n-doping the perovskite film, which facilitates electron transfer to the electron transport layer TiO 2 . A concentration-dependent film structure was observed by X-ray photoemission spectroscopy and grazing incidence wide-angle X-ray scattering where the halides and cations are distributed evenly across perovskite films at low metallic cation concentration (5%). A high metal-cation ratio (20%) leads to halide segregation within the perovskite film and the surface becomes bromide-poor, whereas the bromide and metal cations diffuse more deeply within the film. These differences in electronic properties, element distribution, and film morphology were reflected in the device performance where the power conversion efficiency of low-metallic-cation concentration (5% of Cs + and K + ) perovskite solar cells is ≈5% higher than the high-concentration ones (20%). This study provides valuable chemical and physical insight into the underlying trade-offs in the careful tuning of electrical properties and film structure to optimize multication and mixed-halide hybrid perovskites.

36 MATERIALS SCIENCE↗

Chemistry and Interfacial Structure Promoting Quasi-van der Waals Epitaxial Growth of WS 2 Nanosheets on Sapphire for Prospective Application in Field-Effect Transistors

How do chemical and structural modifications to the supporting crystal surface affect the subsequent van der Waals (vdW) or quasi(Q)-vdW epitaxial growth of 2D nanocrystals? Developing an atomic-scale picture of such an interfacial system is crucial for understanding its impact on the physical and chemical properties of the supported 2D materials. The elucidation of the interfacial structure and chemistry needed to promote the Q-vdW epitaxial growth of 2D tungsten disulfide (WS 2 ) nanocrystals contributes to the growth mechanism understanding, thus pushing forward the integration of such atomically thin semiconductors toward real field-effect transistor applications. In addition to an atomic-force microscopy top view, we showcase a combination of X-ray techniques for a top-to-bottom investigation of the complexities of the buried interface structures. Furthermore, this approach uses X-ray photoelectron spectroscopy, X-ray standing wave excited X-ray fluorescence, and crystal truncation rod scattering to produce a highly resolved chemical-state-specific 3D atomic map for the extended interface structure of WS 2 /α-Al 2 O 3 (001). Employing these detailed analysis methods, along with density functional theory to further refine the picoscale structure, we demonstrate how two different types of interface engineering during the pregrowth stage lead to significant differences in the chemical and structural modifications to the terminal surface of c-face sapphire, which in turn leads to substantial differences in the submonolayer growth of supported WS 2 2D nanocrystals in terms of lateral domain sizes, epitaxial registry, vdW gaps, and stability.

36 MATERIALS SCIENCE↗

Uranium Attenuated by a Wetland 50 Years after Release into a Stream

: Wetlands have several important roles in the hydrological cycle, including maintaining water quality by removing surface and groundwater contaminants. Over time, the wetlands themselves can become contaminated, posing a secondary environmental threat. The objective of this study was to calculate the inventory of uranium (U) remaining in a wetland 50 years after the Fuel Fabrication Facility on the Savannah River Site located in South Carolina released 43.5 Mg of U into the nearby environment. Over 232 700 gamma spectra and their associated global positioning system (GPS) coordinates were collected and collated into a map of the contaminated land area. Five core samples were also collected that contained U concentrations as high as 14 099 mg/kg (background levels are about 2.7 mg/kg U). The contaminated area was 278 000 m2 , and it contained 36.2 Mg U, about 83% of the U released. About 80% of the U in the wetland was concentrated in a former beaver pond, a 73 000 m2 area (26% of the contaminated area). This contaminated wetland area was almost 2 km from the source, indicating that it comprised unique hydro-biogeochemical properties for immobilizing the released U. To the best of our knowledge, this is the first data-rich study to quantify the long-term effectiveness of a wetland to immobilize inorganic contaminants. Significant environmental changes to the system, such as those associated with hydrology, forest fires, or anthropogenic land use, may alter the complex hydro-biogeochemical interactions necessary for the long-term immobilization of the U.

Contaminant inventory↗

Chromosome aberrations and cellular premature senescence as radiation-induced sub-lethal effects: Implications for laser-driven charged-particle radiotherapy

The use of charged particles significantly reduces the dose absorbed by normal cells due to the inverse dose-depth deposition profile. This is the physical pillar justifying hadrontherapy as the eligible treatment for deepseated tumours. However, a non-negligible amount of radiation is nevertheless absorbed in correspondence with the plateau region of the Bragg curve, which may result in the induction of sub-lethal effects. Very little experimental data exist on the induction of such effects. Moreover, reliable follow-up data on such adverse effects in hadrontherapy patients are limited since this type of treatment has been adopted relatively recently. A fortiori, the dependence of sub-lethal effects on unprecedented factors, such as the exceedingly high dose rates and/or the pulsed nature of beams originated by laser interaction with target materials, is unknown. This warrants investigation prior to a therapeutic use of such beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗