Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Low energy electron experiment for AE-C and AE-D

The low energy electron experiment (LEE) will provide differential measurements of the energy influx and angular distributions of electrons and protons on the Atmosphere Explorer C and D missions. The detectors consist of cylindrical electrostatic analyzers for species and energy selection and Spiraltron electron multipliers as particle sensors. The C version will contain three detectors measuring the two species from 0.2 to 25 keV in 16 logarithmically spaced steps, and 5 keV electrons continuously. Angular distributions will be acquired utilizing the spin of the spacecraft. The D version will contain 19 detectors, one proton stepped energy analyzer and two electron stepped energy analyzers at two different angles, again over the energy range 0.2 to 2.5 keV. In addition it will contain 16 fixed energy detectors which will obtain high-time-resolution angular distributions in the spacecraft 1 RPO mode at 5 energies between 0.2 and 5 keV. Increase of these energies by a factor of 3.5 will be possible by ground command.

Hoffman, R. A.↗

Event-sequence detector

Detector consists of matrix of storage elements which are activated by coincidence of failure-voltage pulses and clock pulses. Clock frequency used for event sequence detector can be selected to provide time resolution demanded by test at hand.

Hanna, M. F.↗

LaF3 insulators for MIS structures

Thin films of LaF3 deposited on Si or GaAs substrates have been observed to form blocking contacts with very high capacitances. This results in comparatively hysteresis-free and sharp C-V (capacitance-voltage) characteristics for MIS structures. Such structures have been used to study the interface states of GaAs with increased resolution and to construct improved photocapacitive infrared detectors.

Sher, A.↗

Coronal observations from the SMM satellite

The scientific purpose, coronal observations, and the instrument design and control of the Coronagraph/Polarimeter aboard the Solar Maximum Mission (SMM) satellite are discussed. The instruments were made with an optical design using an achromatic objective lens providing a 10 arcsec resolution in imaging and an SEC vidicon detector allowing integration on the low light levels of the corona. The computer control assures flexibility in the observing program to optimize observations of changing solar phenomena and allows rapid response to SMM or ground-commanded solar flare alerts.

Csoeke-Poeckh, A.↗

X-ray spectra of the Crab pulsar and Nebula

The X-ray spectra of the Crab pulsar and Crab Nebula are analyzed. Observations were made with OSO 8 on March 17-18, 1978, with all spacecraft telemetry assigned to one detector during seven dwell mode experiments. A resolution of 1.25 ms was obtained for pulse-height-analyzed counts in 64 channels. Progressive hardening and subsequent softening of the spectrum across the pulse was found. The fraction of the pulsed flux, exhibiting a spectral variability of about 0.14 was concentrated solely in the region between the two peaks. A model is suggested in which the pulsed X-ray emission from the Crab pulsar consists of two components: one is physically related to the double-peaked gamma-ray pulse and possibly to radio and optical pulses, but has no spectral dependence on the pulse phase, while the other exhibits spectral variability with the pulse phase but is confined to the interpeak emission seen with X-ray energies.

Pravdo, S. H.↗

Performance appraisal of VAS radiometry for GOES-4, -5 and -6

The first three VISSR Atmospheric Sounders (VAS) were launched on GOES-4, -5, and -6 in 1980, 1981 and 1983. Postlaunch radiometric performance is assessed for noise, biases, registration and reliability, with special attention to calibration and problems in the data processing chain. The postlaunch performance of the VAS radiometer meets its prelaunch design specifications, particularly those related to image formation and noise reduction. The best instrument is carried on GOES-5, currently operational as GOES-EAST. Single sample noise is lower than expected, especially for the small longwave and large shortwave detectors. Detector to detector offsets are correctable to within the resolution limits of the instrument. Truncation, zero point and droop errors are insignificant. Absolute calibration errors, estimated from HIRS and from radiation transfer calculations, indicate moderate, but stable biases. Relative calibration errors from scanline to scanline are noticeable, but meet sounding requirements for temporarily and spatially averaged sounding fields of view. The VAS instrument is a potentially useful radiometer for mesoscale sounding operations. Image quality is very good. Soundings derived from quality controlled data meet prelaunch requirements when calculated with noise and bias resistant algorithms.

Chesters, D.↗

1300 + 361 A,B is not a gravitational lens

Spectroscopic observations toward 1300 + 361 B obtained at 320-940 nm using a double spectrograph with CCD detectors on the 5-m Hale telescope (resolution about 7 A at 470-940 nm and 10-12 A at 320-470 nm on April 4-5, 1984, are reported. Two objects with magnitude 20 and spectral characteristics resembling those of an interacting pair of metal-poor H II regions at redshift 0.107 are observed, separated by about 10.6 arcsec and with a velocity difference of less than 80 km/s. It is considered unlikely that these objects form a gravitational-lens system. The ratio of the dereddened flux of the 5007-A forbidden line of O III to that of H-beta is found to be 5.03 for 1300 + 361 A and 3.67 for 1300 + 361 B; the difference is attributed to the presence of star-forming regions in the interacting system.

Halpern, J. P.↗

The ion mass spectrometer on Giotto

The design of the Giotto ion mass spectrometer (IMS) system, its calibration, and the initial flight performance are discussed. The IMS system consists of two sensors: one optimized for the outer coma, the other for the inner coma, with each sensor obtaining complementary information in the region for which it was not optimized. Both sensors feature mass-imaging characteristics, permitting simultaneous measurements of several ion species by means of multi-detector arrays, with resultant mass per charge resolution of not less than 20. In addition to mass per charge, the energy per charge and the elevation and azimuth of the incident ions were measured during the Giotto flight.

Balsiger, H.↗

Plasma properties of hot coronal loops utilizing coordinated SMM and solar research rocket observations

Three improvements in photographic x-ray imaging techniques for solar astronomy are presented. The testing and calibration of a new film processor was conducted; the resulting product will allow photometric development of sounding rocket flight film immediately upon recovery at the missile range. Two fine grained photographic films were calibrated and flight tested to provide alternative detector choices when the need for high resolution is greater than the need for high sensitivity. An analysis technique used to obtain the characteristic curve directly from photographs of UV solar spectra were applied to the analysis of soft x-ray photographic images. The resulting procedure provides a more complete and straightforward determination of the parameters describing the x-ray characteristic curve than previous techniques. These improvements fall into the category of refinements instead of revolutions, indicating the fundamental suitability of the photographic process for x-ray imaging in solar astronomy.

Moses, J. Daniel↗

Differential imaging system

In this study, a technique which enhances image contrast using differentials of radiances being measured from successively overlapping footprints is discussed. One of the immediate advantages of this approach is to improve spatial resolution when the practical size limitation of detectors is reached. When diffraction is considered, radiometric accuracy at the higher spatial frequencies is decreased even though edge response (boundary crossing sharpness) will improve. For instance, an imager system based on this principle could have a primary aperture no larger than 30 cm diameter yet be capable of resolving a ground footprint as small as 2 m from a 780 km altitude.

Kim, Hongsuk H.↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

High resolution diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities found in three crystals grown in space, in four crystals grown entirely on the ground were examined and compared. Irregularities were observed in mercuric iodide, lead tin telluride, triglycine sulfate, and gallium arsenide by high resolution synchrotron x radiation diffraction imaging. Radiation detectors made from mercuric iodide crystals grown in microgravity were reported to perform far better than conventional detectors grown from the same material under full gravity. Effort is now underway to reproduce these 'space' crystals, optimize their properties, and extend comparable superiority to other types of materials.

Steiner, B.↗

Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

Kellogg, E.↗

New concepts for HgI2 scintillator gamma ray spectroscopy

The primary goals of this project are development of the technology for HgI2 photodetectors (PD's), development of a HgI2/scintillator gamma detector, development of electronics, and development of a prototype gamma spectrometer. Work on the HgI2 PD's involved HgI2 purification and crystal growth, detector surface and electrical contact studies, PD structure optimization, encapsulation and packaging, and testing. Work on the HgI2/scintillator gamma detector involved a study of the optical - mechanical coupling for the optimization of CsI(Tl)/HgI2 gamma ray detectors and determination of the relationship between resolution versus scintillator type and size. The development of the electronics focused on low noise amplification circuits using different preamp input FET's and the use of a coincidence technique to maximize the signal, minimize the noise contribution in the gamma spectra, and improve the overall system resolution.

Iwanczyk, Jan S.↗

Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

Mercado, AL↗

Geostationary Imaging FTS (GIFTS) Data Processing: Measurement Simulation and Compression

GIFTS (Geostationary Imaging Fourier Transform Spectrometer), a forerunner of next generation geostationary satellite weather observing systems, will be built to fly on the NASA EO-3 geostationary orbit mission in 2004 to demonstrate the use of large area detector arrays and readouts. Timely high spatial resolution images and quantitative soundings of clouds, water vapor, temperature, and pollutants of the atmosphere for weather prediction and air quality monitoring will be achieved. GIFTS is novel in terms of providing many scientific returns that traditionally can only be achieved by separate advanced imaging and sounding systems. GIFTS' ability to obtain half-hourly high vertical density wind over the full earth disk is revolutionary. However, these new technologies bring forth many challenges for data transmission, archiving, and geophysical data processing. In this paper, we will focus on the aspect of data volume and downlink issues by conducting a GIFTS data compression experiment. We will discuss the scenario of using principal component analysis as a foundation for atmospheric data retrieval and compression of uncalibrated and un-normalized interferograms. The effects of compression on the degradation of the signal and noise reduction in interferogram and spectral domains will be highlighted. A simulation system developed to model the GIFTS instrument measurements is described in detail.

Huang, Hung-Lung↗

Abundance of the Radioactive Be-10 in the Cosmic Radiation up to 2 GeVnucleon-l with the Balloon-borne Instrument ISOMAX1998

The Isotope Magnet Experiment (ISOMAX) a balloon-borne superconducting magnet spectrometer was designed to measure the isotopic composition of the light isotopes (3 less than or equal to Z less than or equal to 8) of the cosmic radiation up to 4 GeV nucleon (exp -1) with a mass resolution of better than 0.25 amu by using the velocity vs. rigidity technique. To achieve this stringent mass resolution ISOMAX was comprised of three major detector systems, a magnetic rigidity spectrometer with a precision drift chamber tracker in conjunction with a three-layer time-of-flight system and two silica-aerogel Cherenkov counters for the velocity determination. A special emphasis of the ISOMAX program was the accurate measurement of radioactive Be-10 with respect to its stable neighbor isotope Be-9, which provides important constraints on the age of cosmic rays in the Galaxy. ISOMAX had its first balloon flight on August 4-5, 1998, from Lynn Lake, Manitoba, Canada. Thirteen hours of data were recorded during this flight at a residual atmosphere of less than 5 g per square centimeter. The isotopic ratio at the top of the atmosphere for Be-10/Be-9 was measured to be 0.195 plus or minus 0.036 (statistical) plus or minus 0.039 (systematic) between 0.26 - 1.03GeV nucleon (exp -1) and 0.317 plus or minus 0.109 (statistical) plus or minus 0.042 (systematic) between 1.13 - 2.03GeV nucleon(exp -1). This is the first measurement of its kind above 1 GeV nucleon (exp -1). ISOMAX results tend to be higher than predictions from current propagation models.

Hams, T.↗