Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

TU-AB-201-10: Novel Conformal Skin Brachytherapy Device

Purpose: A novel conformal skin brachytherapy (CSBT) device was developed to provide patient specific treatment for small inoperable lesions and irregular surfaces that are not good candidates for electron external beam, e.g. eyelids, nose, lips, ears, etc. Methods: A prototype was built and tested using radioactive seeds spaced by 1.5 mm attached to a 3D printed template. Seeds were allowed to move independently at treatment surface to conform to target geometry. Beta-emitter Praseodymium-142 (half-life: 19.12 h, average beta energy: 809 keV) and Iodine-125 Model 6711 (half-life: 59.4 days, average gamma energy: 28 keV) seeds were used to test the feasibility of the device in solid water phantom for different prescription depths and surface areas. Percent depth doses and dose profiles were analyzed. MCNPX2.6 Monte Carlo Simulation and Gafchromic EBT3 film measurements were performed for a single Pr-142 seed. Treatment with nineteen I-125 seeds was planned in BrachyVision and measured experimentally for a total dose of 500 cGy at 5.0 mm depth. Results: For a single Pr-142 seed, dose was 500.0 cGy at surface and 17.4 cGy at 5.00 mm. BrachyVision planned and film doses for I-125 seed matrix were 500 cGy and 473.5 cGy at 5 mm depth and 171.0 cGy and 201.0 cGy at 10 mm depth. Total covered surface area for Pr-142 and I-125 were 2.35 mm{sup 2} and 88.24 mm{sup 2} respectively. Profile dose fall-off showed to be very conformal to contact area with 50% of the total surface dose from a single Pr-142 and array of I-125 seeds being deposited at 0.72 mm and 0.65 mm respectively from the central axis. Conclusion: CSBT device provides a high conformal dose to small surfaces. BrachyVision can be used to predict clinical dose distributions for multiple seeds matrix. Different radioactive seeds can be used to suit prescription depth and treatment area.

60 APPLIED LIFE SCIENCES↗

Optimal Control of an Oscillating Surge Wave Energy Converter

During this project, we experimentally investigated the hydrodynamics and performance of a laboratory-scale oscillating surge wave energy converter (OSWEC).We looked at how flap buoyancy and driveline losses (primarily in the form of stiction) affected the dynamics and performance of the device. In addition, we assessed the influence of flap profile (rounded vs. square edges) on OSWEC hydrodynamics. Through this, we were able to develop a deeper understanding of OSWEC performance and provide guidance on strategies to counteract artifacts that may be present in laboratory models, but are absent in field-scale devices. To do this, we tested a laboratory-scale OSWEC in the Sea Wave Environmental Lab (SWEL) wave tank at the National Renewable Energy Laboratory (NREL). We ran several types of experiments to investigate the hydrodynamics and performance of the device. Overall, we achieved the overall goal of experimentally investigating the hydrodynamics and performance of this device. We discovered important and unexpected trends in performance, and collected time-resolved data to help us further investigate the underlying hydrodynamics responsible for these trends. In addition, we are currently using the time-resolved data from these experiments to build data-driven models of the dynamics, which can in turn be used to inform data-driven model predictive control of this device and address this objective in the future.

16 TIDAL AND WAVE POWER↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Module OT Laboratory Test Procedure

This document will detail a test procedure, involving bench and emulation testing, for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation protocol for the module for lab-level testing; this includes checklists and experiments for information gathering, functional testing, cryptographic implementation, public key infrastructure, key exchange/authentication, encryption, and implementation testing in the emulation environment.

97 MATHEMATICS AND COMPUTING↗

Time-dependent THMC properties and microstructural evolution of damaged rocks in excavation damage zone

Modeling coupled thermo-hydro-mechanical-chemical (THMC) processes in host rocks near high-level nuclear waste (HLW) repositories at various time scales is an extremely challenging task. The current study integrates experimental, theoretical, and numerical methods in assessing the evolution of excavation damage zone (EDZ) over time and its implication on the long-term migration of hazardous species. Argillite and rock salt and are the focus of this study. The first part of the report presents a novel time-dependent directional microcrack damage theory for generic brittle rocks. It features detailed statistical description of the microcracks within a damaged solid, permitting a direct upscaling of microscale processes such as crack growth kinetics, crack closure/opening, sliding friction to explain the macroscopic creep, nonlinear elasticity, shear dilation, and loading-unloading hysteresis. This provides a basic platform for describing the anisotropic mechanical and transport properties of damaged rocks during excavation and subsequent THMC loadings. The model is validated and numerically implemented to Finite Element (FE) package ABAQUS through the user-defined material (UMAT) interface and have demonstrated great potential in resolving the time-dependent and anisotropic evolution of damage in the EDZ. The second part of the report presents a multi-scale experimental effort in characterizing the thermal, hydraulic, and mechanical properties of Mancos shale and Avery Island salt. For the Mancos shale, triaxial compression tests are performed at different confining pressures and temperatures to probe its thermomechanical properties relevant to HLW repositories. The obtained stress-strain data are interpreted using the proposed directional damage theory. Post-test specimens are subjected to gas permeability tests to reveal the correlation between permeability and the degree of microcracking. At microscale, temperature-controlled nanoindentation tests are performed and found a linear correlation between fracture toughness and elastic modulus from 25°C to 300°C. For Avery Island salt, we have designed and manufactured a novel relative-humidity controlled uniaxial creep device. Long-term creep tests at low stresses (< 5 MPa) are performed at different levels of relative humidity (RH). Besides confirming the much higher creep rates as one would expect through extrapolating the high-stress creep data, the results reveal that the steady-state creep rate of rock salt is strongly dependent on the ambient RH, an aspect that is often neglected in the literature. Both behaviors can be attributed to the pressure-solution creep mechanism which dominates at low stress and high RH levels. The third part of the report explores a set of numerical strategies in modeling the THMC behavior of porous geomaterials. A fully implicit, monolithic FE solution that can flexibly interface with different material models and coupling mechanisms for THMC problems is developed and verified through the ABAQUS user-defined element (UEL) interface. The scheme is used to study the THM response of a hypothetical HLW storage site with reference to an existing in-situ heater test. Strategies for integrating the UEL and the microcrack UMAT are suggested. Another numerical endeavor of this study is to implement a higher-order asymptotic homogenization method to account for the heterogeneous porous structures. The same method is then extended to perform microstructure-informed thermo-mechanical modeling of generalized continua. The above outcomes of this project provide a strong thrust towards enhancing the fundamental understanding and modeling capability of the long-term evolution of host rocks in EDZ, thus helping achieve the design goal of 1-million-year isolation of high-level nuclear wastes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Power Test Results For A Cylindrical-Shell SiC Higher-Order-Mode DAMPER

The next high-current Electron Ion Collider (EIC) is a new accelerator to be built at Brookhaven National Laboratory (BNL) in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). In the EIC Electron Storage Ring (ESR), there will be beam currents up to 2.5 A, which will excite massive Higher-Order-Modes (HOM) power in the 17 single-cell 591 MHz Superconducting Radio Frequency (SRF) cavities. To damp the HOM power in the ESR SRF cavities is a challenge. A room temperature cylindrical shell shape Silicon Carbide (SiC) Beamline HOM Absorber (BLA) was chosen as the baseline design, due to its broadband and high-power capability, and previous demonstrations at other accelerator facilities, albeit at much lower power. Because the EIC BLA HOM power dissipation is significantly greater than the previous applications, it is imperative to carry out high power testing to determine the maximum device performance levels achievable for thermal transport, RF breakdown, and mechanical stress, prior to finalizing the design. A SiC HOM absorber with state-of-the-art geometry size was prototyped to verify shrink-fit technique, test outgassing rate, and high power handling capability. This paper presents the HOM damper’s prototyping and test results.

43 PARTICLE ACCELERATORS↗

Note: Space qualified photon counting detector for laser time transfer with picosecond precision and stability

The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stability is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of −55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Comparison of Trench and Planar Silicon Carbide (SiC) MOSFET at Different Temperatures

In this paper, the static and dynamic characteristics of discrete 650 V and 1200 V trench TO 247 SiC MOSFET is evaluated and compared with a similar current rating 1200 V planar gate discrete TO 247 SiC MOSFET. The new trench MOSFET has promising application for vehicle charging and auxiliary power supply application due to the lower on-state resistance and lower capacitance. Static characteristics for these devices are evaluated using a curve tracer for different device junction temperature A common double pulse test (DPT) platform is developed to evaluate the switching loss at different device junction temperature ranging from 25°C to 175°C. The experimental setup and results are presented for different load currents and temperature.

Anwar, Saeed↗

50% continuous-wave wallplug efficiency from 1.53μm-emitting broad-area diode lasers

Long-wavelength InP-based diode lasers emitting at 1.53 μm have been optimized for maximum continuous-wave (CW) electrical-to-optical power conversion efficiency, so-called wallplug efficiency (WPE). Efficient electron and hole capture into a single-quantum-well (SQW) active region as well as suppression of electron and hole leakage out of the SQW result in high values for the internal differential efficiency: ∼97% for long-cavity (≥2 mm) uncoated-facet devices and ∼85%–89% for short-cavity (1.5 mm) optimized facet-coated devices. The characteristic temperature of the slope efficiency, T{sub 1}, reaches a high value of 323 K. Doping-level optimization of the p-cladding layer and the use of the SQW result in low values for the internal loss coefficient: ∼1.1 cm{sup −1} for long-cavity (≥2 mm) uncoated-facet devices and ∼1.5–2.0 cm{sup −1} for short-cavity (1.5 mm) optimized facet-coated devices. In turn, a maximum CW WPE value of 50% is achieved at room temperature and ∼1 W output power from conductively-cooled 100 μm-wide-aperture devices. The maximum CW power is 2.5 W. One beneficial byproduct of the CW-WPE maximization process is a large transverse spot size which, in turn, provides a very narrow transverse beamwidth: 26° full width half maximum. Reliability tests show no degradation when devices are run CW at high currents (4–5 A) and high temperatures (40–50 °C) for over 4000 h, at ∼2 W output power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-power test results for a cylindrical-shell silicon carbide higher-order-mode damper

The next high-current Electron-Ion Collider (EIC) is a new accelerator to be built at Brookhaven National Laboratory in collaboration with Thomas Jefferson National Accelerator Facility. In the EIC Electron Storage Ring (ESR), there will be beam currents of up to 2.5 A, which will excite massive higher-order-mode (HOM) power in the 17 single-cell 591 MHz superconducting radio-frequency (SRF) cavities. Damping the HOM power in the ESR SRF cavities is a challenge. A room temperature cylindrical shell shape silicon carbide (SiC) beamline HOM absorber (BLA) was chosen as the baseline design, due to its broadband and high-power capability, and previous demonstrations at other accelerator facilities, albeit at much lower power. Because the EIC BLA HOM power dissipation is significantly greater than the previous applications, it is imperative to carry out high-power testing to determine the maximum device performance levels achievable for thermal transport, rf breakdown, and mechanical stress, prior to finalizing the design. A SiC HOM absorber with a state-of-the-art geometry size was prototyped to verify the shrink-fit technique, test outgassing rate, and high-power handling capability. This paper presents the HOM damper’s prototyping and test results. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Experimental evidence of hole injection through V-defects in long wavelength GaN-based LEDs

Hole injection through V-defect sidewalls into all quantum wells (QWs) of long wavelength GaN light emitting diodes had previously been proposed as means to increase efficiency of these devices. In this work, we directly tested the viability of this injection mechanism by electroluminescence and time-resolved photoluminescence measurements on a device in which QW furthest away from the p-side of the structure was deeper, thus serving as an optical detector for presence of injected electron–hole pairs. Emission from the detector well confirmed that, indeed, the holes were injected into this QW, which could only take place through the {$10\bar{1}1$} V-defect sidewalls. Unlike direct interwell transport by thermionic emission, this transport mechanism allows populating all QWs of a multiple QW structure despite the high potential barriers in the long wavelength InGaN/GaN QWs.

Atomic force microscopy↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

Gripper Test Assembly Status Report (FY2020)

Refueling systems for fast reactors are designed to handle fresh and used core assemblies (fuel, reflector, and shield core assemblies) within the reactor vessel in an opaque coolant environment without visual reference. These refueling machines are designed to work in a sodium (or other fast reactor coolant) and argon vapor space environment and are engineered with the rotatable plug system to allow for the movement of fresh and spent fuel into and out of the reactor core. The refueling machines are a critical component in any reactor and thus need to undergo extensive testing in a prototypic environment to ensure that they will meet all of the system functions and requirements. Argonne has developed an innovative compact refueling system design for the Advanced Fast Reactor-100 that is based upon some mechanisms used in previous reactor designs, such as the U.K.’s Prototype Fast Reactor (PFR) and some mechanisms that have not been used in sodium. This compact refueling machine supports the reduction in size of the AFR-100’s reactor vessel, and if fully developed, would support and inform the development of the in-vessel refueling machines for such commercial reactors as the GEH PRISM reactor plant, the ARC Clean Energy’s ARC-100 reactor, and the Natrium reactor, among others. This refueling system is a vital component of a fast reactor that supports reducing the cost of the reactor and increasing its reliability. During the development of the compact fuel handling machine conceptual design for the AFR-100, a lack of testing data for many mechanical components in sodium under typical in-reactor loads and conditions was discovered. The reduction in lifetime of the various mechanical components in the liquid sodium environment needs to be quantified versus the calculated component lifetimes under normal conditions in the testing while they are subjected to typical loading profiles experienced in the past. The Gripper Test Assembly discussed here includes a full-size gripper device with appropriate mechanical features that will be tested in sodium to provide this testing data. The Gripper Test Assembly is used to test various mechanical fuel handling components submerged in high temperature liquid sodium. These mechanisms are gears, bearings, gripper jaws and head, universal joints and shafts, ball screws, among others. These components will be tested under the typical sodium environmental conditions experienced during refueling operations with appropriate loading conditions that simulate the removal and insertion of core assemblies into a fast reactor grid plate structure. This Gripper Test Assembly is the second in a series of refueling system mechanisms developed for testing in sodium. The first test assembly is the Gear Test Assembly (GTA) which was used to test the performance of gears and bearings operating in sodium. Because of the successful testing conducted with the GTA, it was decided to continue with the development of the Gripper Test Assembly which uses the same gears and bearings tested in GTA. Using the data collected during operation of this gripper test assembly, lifetime reduction factors of the various mechanical components can be calculated for the material combinations selected. These lifetime reduction factors can be used in the design of future mechanical systems which operate in these environments to accurately predict component end of life. In addition, an understanding of the ability of these components and mechanisms to operate under-sodium with the chosen materials will be accomplished. Again, this Gripper Test Assembly is the follow-on test article to the Gear Test Assembly which was testing the ability of gears and bearings operating in a sodium environment. Once fabricated and qualified, it will be tested in the Mechanism Engineering Test Loop (METL) facility located in Building 308 at Argonne National Laboratory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solid phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Solid-phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

APPLICATIONS OF BIOTECHNOLOGY IN DEVELOPMENT OF BIOMATERIALS: NANOTECHNOLOGY AND BIOFILMS

Biotechnology is the application of biological techniques to develop new tools and products for medicine and industry. Due to various properties including chemical stability, biocompatibility, and specific activity, e.g. antimicrobial properties, many new and novel materials are being investigated for use in biosensing, drug delivery, hemodialysis, and other medical applications. Many of these materials are less than 100 nanometers in size. Nanotechnology is the engineering discipline encompassing designing, producing, testing, and using structures and devices less than 100 nanometers. One of the challenges associated with biomaterials is microbial contamination that can lead to infections. In recent work we have examined the functionalization of nanoporous biomaterials and antimicrobial activities of nanocrystalline diamond materials. In vitro testing has revealed little antimicrobial activity against Pseudomonas fluorescens bacteria and associated biofilm formation that enhances recalcitrance to antimicrobial agents including disinfectants and antibiotics. Laser scanning confocal microscopy studies further demonstrated properties and characteristics of the material with regard to biofilm formation.

60 APPLIED LIFE SCIENCES↗

NREL Topic 1 Final Report: Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project entitled 'Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL) Integrated Network Test-bed for Energy Grid Research and Technology (INTEGRATE) initiative. The Electric Power Research Institute (EPRI) and a team of partners were selected by NREL to carry out a project to develop and test how smart, connected consumer devices can act to enable the use of more clean energy technologies on the electric power grid. The project team includes a set of leading companies that produce key products in relation to achieving this vision: thermostats, water heaters, pool pumps, solar inverters, electric vehicle supply equipment, and battery storage systems. A key requirement of the project was open access at the device level - a feature seen as foundational to achieving a future of widespread distributed generation and storage. The internal intelligence, standard functionality and communication interfaces utilized in this project result in the ability to integrate devices at any level, to work collectively at the level of the home/business, microgrid, community, distribution circuit or other. Collectively, the set of products serve as a platform on which a wide range of control strategies may be developed and deployed.

24 POWER TRANSMISSION AND DISTRIBUTION↗