Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Generalized Kompaneets formalism for inelastic neutrino-nucleon scattering in supernova simulations

Based on the Kompaneets approximation, we develop a robust methodology to calculate spectral redistribution via inelastic neutrino-nucleon scattering in the context of core-collapse supernova simulations. The resulting equations conserve lepton number to machine precision and scale linearly, not quadratically, with number of energy groups. The formalism also provides an elegant means to derive the rate of energy transfer to matter which, as it must, automatically goes to zero when the neutrino radiation field is in thermal equilibrium. Furthermore, we derive the next higher order in $ϵ/mc^2$ correction to the neutrino Kompaneets equation. Unlike other Kompaneets schema, ours also generalizes to the case of anisotropic angular distributions, while retaining the conservative form that is a hallmark of the classical Kompaneets equation. In this work, our formalism enables immediate incorporation into supernova codes that follow the spectral angular moments of the neutrino radiation fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Utica Shale Energy and Environment Laboratory Final Scientific/Technical Report

The Ohio State University (OSU) was awarded a contract on October 1, 2014, from the Department of Energy National Energy Technology Laboratory (DOE-NETL) to develop the Utica Shale Energy and Environment Laboratory (USEEL) in the Utica-Point Pleasant shale play of the Appalachian Basin. It was designed to be an environmental and technology development lab that would enable the academic, industry, government, and non-governmental organization (NGO) research communities to better understand unconventional oil and gas (UOG) engineering practices and technology to increase production and safety, and decrease environmental effects. Political and economic consequences necessitated changes in project site location and design, from the Ohio State Eastern Agricultural Research Station (EARS) and the Muskingum Watershed Conservancy District (MWCD) in east-central Ohio to a site located at an Energy Corporation of America (ECA) Marcellus drill pad in Greene County, Pennsylvania. Although the overall project progressed little beyond planning and administration before termination on September 18, 2017, significant research and MS or PhD investigations were completed or continue today. An experimental study design for site specific and regional baseline assessments was developed utilizing ecoregions, United States Geological Survey (USGS) Hydraulic Unit Code watersheds, and GIS technology and databases. This can be utilized to build a defensible and scalable management and research framework for UOG investigations that can be extrapolated for predictive and comparative analyses. The most commonly mentioned perceived risks of shale energy development identified in a socioeconomic analysis included impacts to the environment and water resources, traffic and road deterioration, and crime. Economic benefits, such as the windfall wealth to residents, job opportunities, and the demand for hotels and restaurants emerged, as the main positive impact to the community. Preliminary results of an analysis of the location and mechanisms for extremely high pore pressures of the deep Utica-Point Pleasant formations of southwestern Pennsylvania and their possible relationship to high initial production rates indicate that the overpressure is caused by a combination disequilibrium compaction and fluid expansion. Drilling fluids research designed a proof-of-concept device to evaluate desalination and solvent separation in hydraulic fracturing flowback water that could facilitate water recycling and potentially mitigate deep-well injection. A groundwater study was devised to characterize the subsurface aquifers in terms of the geological framework and groundwater chemistry, including the chemistry of dissolved gases and salts. Brines and gases associated with hydrocarbon migration in groundwater (including noble gases and hydrocarbons) were to be specifically fingerprinted for use as tracers of fluid migration. Trace element analysis of fish otoliths, using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), is being utilized to assess surface water quality. This methodology will be used to reconstruct the exposure histories of fish from watersheds and discriminate between the signatures associated with hydraulic fracturing and coal mining activities.

03 NATURAL GAS↗

Boil-off losses along LH2 pathway

Losses along the LH 2 pathway are intrinsic to the utilization of a cryogenic fluid. They occur when the molecule is transferred between 2 vessels (liquefaction plant to trailer, trailer to station storage, station storage to pump or compressor, then fuel cell electric vehicles …) and when the fluid is warmed up due to heat transfer with the environment. Those losses can be estimated with good accuracy using thermodynamic models based on conservation of mass and energy, providing the thermodynamic states are correctly described. Indeed, the fluid undergoes various changes as it moves along the entire pathway (2 phase transition, super-heated warming, non-uniform temperature distributions across the saturation film) and accurate equations of state and 2 phase behavior implementations are essential. The balances of mass and energy during the various dynamics processes then enable to quantify the boil-off losses. In this work, a MATLAB code previously developed by NASA to simulate rocket loading is used as the basis for the LH 2 transfer model. This code implements complex physical phenomena such as the competition between condensation and evaporation and the convection vs. conduction heat transfer as a function of the relative temperatures on both sides of the saturated film. The original code was modified to consider real gas equations of state, and some semi-empirical relationships, such as between the heat of vaporization and the critical temperature, were also replaced by a REFPROP equivalent expression, assumed to be more accurate. Non-constant liquid temperature equations were added to simulate sub-cooled conditions. It is shown that although trailer depressurization and transfer losses from the receiving vessel during a LH 2 delivery may constitute the largest sources of losses, those can be greatly reduced and even eliminated if CFR/DOT regulations are properly applied and if no-vent fill methods are implemented, particularly for a stationary LH2 storage operating at reasonably low pressure (45 psia or so). As such, it is expected that the only remaining boil-off losses for a refueling station would come from the LH 2 pump (utilization and idling), pump vessel cool down/warm up, and environment heat transfer. Based on experimental data measured at LLNL on the Linde 875 bar LH 2 cryo-pump and results from the model, and extrapolating for refueling stations of various sizes, it can be shown that boil-off losses can vary from 15% of delivered LH 2 for a 100 kg/day, 5% at 400 kg/day, and down to less than 2% for stations above 1,800 kg/day (for a system similar to the one at LLNL). Less boil-off is to be expected for LH 2 pumps dispensing at 350 bar, so that less than 0.7% can be expected above 1,800 kg/day station capacities. At last, boil-off recovery solutions are briefly analyzed, including compressors, cryo-coolers and stationary fuel cell. Their economic value is strongly related to the costs of H2 and of the electricity needed to perform the recovery, on top of the initial capital expenditures. Effective boil-off could be reduced to 0.6-1% for a 2,000 kg/day station if adequate recovery solutions are used.

08 HYDROGEN↗

Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE EV Data Collection - Vehicle Data

Vehicle data consist of electric vehicle performance data collected directly from the vehicle during standard operations. Data were collected using onboard data loggers that were either installed by the project team or preinstalled by the original equipment manufacturer. Data recorded by the data loggers were made accessible via an online web portal or an application programming interface. Different data loggers were used (HEM, ViriCiti, and Geotab), and the method for each vehicle is defined in the vehicle attributes file. Some systems collected data on a “trip-level” basis, in which each row of a table represents a single trip (the period between a key-on and key-off event), whereas other data were collected on a per-day basis, in which each row represents a single day of operation. Data were collected over a range of data collection periods, depending on the project. Data have been anonymized by removing information or decreasing information resolution as necessary so that fleets are not identifiable. Due to the wide range of vehicle types represented and variation in data collection, data parameters and frequencies differ between vehicles and fleets The **Performance Data Daily/Trip Data Dictionaries** contain definitions for each available parameter associated with a vehicle’s operations, aggregated at either a daily or trip level. The parameters available will vary from vehicle to vehicle, but every possible parameter will be defined. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. The **Vehicle Data** tables contain the data from each vehicle’s operations, aggregated at either a daily or trip level, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combustion Safety Simplified Test Protocol Field Study

"9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

United States County-Level Industrial Energy Use

Estimated industrial manufacturing agriculture construction and mining energy estimated by North American Industrial Classification System NAICS code county and fuel type for 2014. Additional disaggregation by end use e.g. machine drive process heating facility lighting is provided for manufacturing agriculture and mining industries. Estimation approach is described in detail in the data_foundation folder here https//github.com/NREL/Industry-Energy-Tool/.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expanded Energy Credits in Energy Codes (Technical Brief)

This technical brief provides additional energy efficiency measures that go beyond the current prescriptive commercial energy codes. It demonstrates relative savings for multiple measures and shows a base cost effective package by building type and climate zone. An advanced savings package is also shown. Potential building savings for the base package for different building types across climate zones range from 3.9% to 22% of building energy cost, while the advanced package building savings range from 8.4% to 44%. In addition to measure descriptions, this technical brief includes code language that can be adopted by local jurisdictions to implement these measures for new buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measure Guideline: Buried and/or Encapsulated Ducts

Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. This Building America Measure Guideline synthesizes previously published research on BEDs and provides practical information to builders, contractors, homeowners, policy analysts, building professions, and building scientists. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license. Persons implementing duct system improvements should not go beyond their expertise or qualifications. This guideline provides valuable information for a building industry that has struggled to address ductwork thermal losses in new and existing homes. As building codes strengthen requirements for duct air sealing and insulation, flexibility is needed to address energy efficiency goals. While ductwork in conditioned spaces has been promoted as the panacea for addressing ductwork thermal losses, BEDs installations approach - and sometimes exceed - the performance of ductwork in conditioned spaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEPOSITION VELOCITY ESTIMATION WITH THE GENII V2 SOFTWARE

In 2010, the Department of Energy (DOE) Chief of Nuclear Safety and Office of Health, Safety and Security (HSS), with the support of industry experts in atmospheric sciences and accident dose consequences analysis, performed detailed analyses of the basis for the dry deposition velocity (DV) values used in the MACCS2 computer code. As a result of these analyses, DOE concluded that the historically used default DV values of 1 centimeter/second (cm/s) for unfiltered/unmitigated releases and 0.1 cm/s for filtered/mitigated releases may not be reasonably conservative for all DOE sites and accident scenarios. HSS recently issued Safety Bulletin 2011-02, Accident Analysis Parameter Update, recommending the use of the newly developed default DV, 0.1 cm/s for an unmitigated/unfiltered release. Alternatively site specific DV values can be developed using GENII version 2 (GENII v2) computer code. Key input parameters for calculating DV values include surface roughness, maximum wind speed for calm, particle size, particle density and meteorological data (wind speed and stability class). This paper will include reasonably conservative inputs, and a truncated parametric study. In lieu of the highly-conservative recommended DV value (0.1cm/s) for unmitigated/unfiltered release, GENII v2 has been used to justify estimated 95th percentile DV values. Also presented here are atmospheric dilution factors ({chi}/Q values) calculated with the MACCS2 code using the DV values form GENII v2, {chi}/Q values calculated directly with GENII v2, and a discussion of these results compare with one another. This paper will give an overview of the process of calculating DV with GENII v2 including a discussion of the sensitivity of input parameters.

99 GENERAL AND MISCELLANEOUS↗

Simulation-aided occupant-centric building design: A critical review of tools, methods, and applications

Occupants are active participants in their built environment, affecting its performance while simultaneously being affected by its design and indoor environmental conditions. With recent advances in computer modeling, simulation tools, and analysis techniques, topics such as human-building interactions and occupant behavior have gained significant interest in the literature given their premise of improving building design processes and operating strategies. In practice, the focus of occupant-centric literature has been mostly geared towards the latter (i.e., operation), leaving the implications on building design practices underexplored. This paper fills the gap by providing a critical review of existing studies applying computer-based modeling and simulation to guide occupant-centric building design. The reviewed papers are organized along four main themes, namely occupant-centric: (i) metrics of building performance, (ii) modeling and simulation approaches, (iii) design methods and applications, and (iv) supporting practices and mechanisms. Important barriers are identified for a more effective application of occupant-centric building design practices, including the limited consideration of metrics beyond energy efficiency (e.g., occupant well-being and space planning), the limited implementation and validation of the proposed methods, and the lack of integration of occupant behavior modeling in existing building performance simulation tools. Finally, future research directions are discussed, covering large-scale international data collection efforts to move from generic assumptions about occupant behavior to specific/localized knowledge, improved metrics of measuring building performance, and improved industry practices, such as building codes, to promote an occupant-in-the-loop approach to the building design process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reference Piping and Instrumentation Diagrams for Heat Transport Systems for Methanol Plants

This report aims to bridge the gap between advanced nuclear reactor vendors and methanol producers seeking decarbonization. It equips both parties with tools and preliminary information for integrating clean heat from advanced reactors into novel methanol production processes. The proposed investigation in this report involves a three-step approach: 1. Design of Current and Decarbonized Process Models for Methanol Production. This report initiates process modeling of two novel methanol production pathways, with their overall energy requirements comparative to classical methanol production (see Figure ES1). The two process models provide the foundation for analyzing integration of hermos-electric generation from advanced nuclear reactors. 2. Identification of Coupling Points to Integrate Advanced Reactors. This report investigates the integration with two advanced reactor technologies: light-water reactors (LWRs) and high-temperature gas reactors (HTGRs). The key coupling points between advanced nuclear reactors and the production facilities associated with the two decarbonized methanol process pathways are identified. 3. Preliminary Heat and Electricity Transfer Design from Reactors to Methanol Production Sites. The preliminary designs for piping and instrumentation to transfer heat from the boundary of advanced reactor technology location to the boundary of methanol production site are evaluated within the context of decarbonized pathways. The pipe analysis for heat transfer adheres to relevant codes and specifications from American Society of Mechanical Engineering. A simplified design for transmission of electricity to the industrial site has been provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GAMMA-RAY BURST DYNAMICS AND AFTERGLOW RADIATION FROM ADAPTIVE MESH REFINEMENT, SPECIAL RELATIVISTIC HYDRODYNAMIC SIMULATIONS

We report on the development of Mezcal-SRHD, a new adaptive mesh refinement, special relativistic hydrodynamics (SRHD) code, developed with the aim of studying the highly relativistic flows in gamma-ray burst sources. The SRHD equations are solved using finite-volume conservative solvers, with second-order interpolation in space and time. The correct implementation of the algorithms is verified by one-dimensional (1D) and multi-dimensional tests. The code is then applied to study the propagation of 1D spherical impulsive blast waves expanding in a stratified medium with {rho}{proportional_to}r{sup -k}, bridging between the relativistic and Newtonian phases (which are described by the Blandford-McKee and Sedov-Taylor self-similar solutions, respectively), as well as to a two-dimensional (2D) cylindrically symmetric impulsive jet propagating in a constant density medium. It is shown that the deceleration to nonrelativistic speeds in one dimension occurs on scales significantly larger than the Sedov length. This transition is further delayed with respect to the Sedov length as the degree of stratification of the ambient medium is increased. This result, together with the scaling of position, Lorentz factor, and the shock velocity as a function of time and shock radius, is explained here using a simple analytical model based on energy conservation. The method used for calculating the afterglow radiation by post-processing the results of the simulations is described in detail. The light curves computed using the results of 1D numerical simulations during the relativistic stage correctly reproduce those calculated assuming the self-similar Blandford-McKee solution for the evolution of the flow. The jet dynamics from our 2D simulations and the resulting afterglow light curves, including the jet break, are in good agreement with those presented in previous works. Finally, we show how the details of the dynamics critically depend on properly resolving the structure of the relativistic flow.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-order energy-conserving gyrokinetic theory

A higher-order self-consistent energy-conserving gyrokinetic system of equations is derived. It is shown that additional terms appear in the quasineutrality condition. These terms are nonlinear in the electric field. The derivation includes higher-order terms in the gyrokinetic Hamiltonian (needed for the energy conservation) and employs a variational principle that automatically provides all the conservation laws through the Noether theorem. The equations derived here can be applied in certain transition layers such as the stellarator transport barriers caused by the transition between the electron and ion root regimes. The theory may also be of interest for the edge plasma, where the nonlinear terms in the quasineutrality equation could be relevant. The equations derived are simple enough and can readily be used in gyrokinetic codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗