Search NASA⌕ Search

SEARCH · Search NASA

Results for “error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Errors in Radiotherapy: Motivation for Development of New Radiotherapy Quality Assurance Paradigms

Modern radiotherapy practice has rapidly evolved during the past decade, making use of many highly complex and/or automated processes for planning and delivery, including new techniques, like intensity-modulated radiotherapy driven by inverse planning optimization methods, or near real-time image-guided adaptive therapy based on fluoroscopic or tomographic imaging on the treatment machine. In spite of the modern technology, or potentially because of it in some instances, errors and other problems continue to have a significant impact on the field. This report reviews example errors and problems, discusses some of the quality assurance issues that these types of problems raise, and motivates the development of more modern and sophisticated approaches to assure quality for our clinical radiotherapy treatment methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test models for improving filtering with model errors through stochastic parameter estimation

The filtering skill for turbulent signals from nature is often limited by model errors created by utilizing an imperfect model for filtering. Updating the parameters in the imperfect model through stochastic parameter estimation is one way to increase filtering skill and model performance. Here a suite of stringent test models for filtering with stochastic parameter estimation is developed based on the Stochastic Parameterization Extended Kalman Filter (SPEKF). These new SPEKF-algorithms systematically correct both multiplicative and additive biases and involve exact formulas for propagating the mean and covariance including the parameters in the test model. A comprehensive study is presented of robust parameter regimes for increasing filtering skill through stochastic parameter estimation for turbulent signals as the observation time and observation noise are varied and even when the forcing is incorrectly specified. The results here provide useful guidelines for filtering turbulent signals in more complex systems with significant model errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transport error estimation using residual Monte Carlo

The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.

97 MATHEMATICS AND COMPUTING↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy

The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had a shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of optical modelling of sunshape and surface slope error for concentrating solar power systems

Sunshape and reflector surface slope error distributions are significant elements in modelling the optical behaviour of a concentrating solar power system. Different optical modelling tools implement these elements with various approaches. Discrepancies can easily accumulate in simulations of a large optical system as a result of incorrect implementations. This study reviews and verifies the implementations of these two factors in six tools that are widely used for optical modelling in solar energy research: Tonatiuh, SolTrace, Tracer, Solstice, Heliosim and SolarPILOT. The review incorporates three rounds of tests. Firstly, basic tests examine each factor carefully in simplified on-axis reflector-target configurations (round 'A'). Secondly, off-axis effects are introduced (round 'B'). Thirdly, full heliostat field simulations are verified (round 'C'). All of the test cases are simulated with each modelling tool, and results are compared. Discrepancies were observed due to approximations inherent in the cone optics (convolution) methods, incorrect implementation the of pillbox slope errors, different approaches to setting the circumsolar ratio for the Buie sunshape, and different approaches to the calculation of blocking and shading losses in some tools. All issues are discussed fully, and solutions to most issues were implemented within the scope of the present study. Some remaining issues are noted. The study highlights the importance of careful implementation of these aspects of optical modelling and contributes to an improvement in the quality of several widely-used tools.

14 SOLAR ENERGY↗

Density Functional Calculations of Native Defects in CH 3 NH 3 PbI 3 : Effects of Spin–Orbit Coupling and Self-Interaction Error

We know that native point defects play an important role in carrier transport properties of CH3NH3PbI3. However, the nature of many important defects remains controversial due partly to the conflicting results reported by recent density functional theory (DFT) calculations. In this Letter, we show that self-interaction error and the neglect of spin–orbit coupling (SOC) in many previous DFT calculations resulted in incorrect positions of valence and conduction band edges, although their difference, which is the band gap, is in good agreement with the experimental value. Moreover, this problem has led to incorrect predictions of defect-level positions. Hybrid density functional calculations, which partially correct the self-interaction error and include the SOC, show that, among native point defects (including vacancies, interstitials, and antisites), only the iodine vacancy and its complexes induce deep electron and hole trapping levels inside of the band gap, acting as nonradiative recombination centers.

36 MATERIALS SCIENCE↗

Structural basis of error-prone replication and stalling at a thymine base by human DNA polymerase

Human DNA polymerase iota (pol iota) is a unique member of Y-family polymerases, which preferentially misincorporates nucleotides opposite thymines (T) and halts replication at T bases. The structural basis of the high error rates remains elusive. We present three crystal structures of pol complexed with DNA containing a thymine base, paired with correct or incorrect incoming nucleotides. A narrowed active site supports a pyrimidine to pyrimidine mismatch and excludes Watson-Crick base pairing by pol. The template thymine remains in an anti conformation irrespective of incoming nucleotides. Incoming ddATP adopts a syn conformation with reduced base stacking, whereas incorrect dGTP and dTTP maintain anti conformations with normal base stacking. Further stabilization of dGTP by H-bonding with Gln59 of the finger domain explains the preferential T to G mismatch. A template 'U-turn' is stabilized by pol and the methyl group of the thymine template, revealing the structural basis of T stalling. Our structural and domain-swapping experiments indicate that the finger domain is responsible for pol's high error rates on pyrimidines and determines the incorporation specificity.

36 MATERIALS SCIENCE↗

Resistive wall mode feedback control in EXTRAP T2R with improved steady-state error and transient response

Experiments in the EXTRAP T2R reversed field pinch [P. R. Brunsell, H. Bergsa ring ker, M. Cecconello et al., Plasma Phys. Control. Fusion 43, 1457 (2001)] on feedback control of m=1 resistive wall modes (RWMs) are compared with simulations using the cylindrical linear magnetohydrodynamic model, including the dynamics of the active coils and power amplifiers. Stabilization of the main RWMs (n=-11,-10,-9,-8,+5,+6) is shown using modest loop gains of the order G{approx}1. However, other marginally unstable RWMs (n=-2,-1,+1,+2) driven by external field errors are only partially canceled at these gains. The experimental system stability limit is confirmed by simulations showing that the latency of the digital controller {approx}50 {mu}s is degrading the system gain margin. The transient response is improved with a proportional-plus-derivative controller, and steady-state error is improved with a proportional-plus-integral controller. Suppression of all modes is obtained at high gain G{approx}10 using a proportional-plus-integral-plus-derivative controller.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic Errors of MiniBooNE

Modern neutrino oscillation experiments use a 'near to far' ratio to observe oscillation; many systematic errors cancel in a ratio between the near detector's unoscillated event sample and the far detector's oscillated one. Similarly, MiniBooNE uses a {nu}{sub e} to {nu}{sub {mu}} ratio, which reduces any common uncertainty in both samples. Here, we discuss the systematic errors of MiniBooNE and how the {nu}{sub {mu}} sample constrains the {nu}{sub e} signal sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A statistical analysis of systematic errors in temperature and ram velocity estimates from satellite-borne retarding potential analyzers

The use of biased grids as energy filters for charged particles is common in satellite-borne instruments such as a planar retarding potential analyzer (RPA). Planar RPAs are currently flown on missions such as the Communications/Navigation Outage Forecast System and the Defense Meteorological Satellites Program to obtain estimates of geophysical parameters including ion velocity and temperature. It has been shown previously that the use of biased grids in such instruments creates a nonuniform potential in the grid plane, which leads to inherent errors in the inferred parameters. A simulation of ion interactions with various configurations of biased grids has been developed using a commercial finite-element analysis software package. Using a statistical approach, the simulation calculates collected flux from Maxwellian ion distributions with three-dimensional drift relative to the instrument. Perturbations in the performance of flight instrumentation relative to expectations from the idealized RPA flux equation are discussed. Both single grid and dual-grid systems are modeled to investigate design considerations. Relative errors in the inferred parameters for each geometry are characterized as functions of ion temperature and drift velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of the Johann error for spherically bent x-ray imaging crystal spectrometers

New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar{sup 16+}, from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric apparatus for hydrogen adsorption and diffusion measurements: Sources of systematic error and impact of their experimental resolutions

The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: Fixed-node errors in quantum Monte Carlo: Interplay of electron density and node nonlinearities

We elucidate the origin of large differences (two-fold or more) in the fixed-node errors between the first- vs second-row systems for single-configuration trial wave functions in quantum Monte Carlo calculations. This significant difference in the valence fixed-node biases is studied across a set of atoms, molecules, and also Si, C solid crystals. We show that the key features which affect the fixed-node errors are the differences in electron density and the degree of node nonlinearity. The findings reveal how the accuracy of the quantum Monte Carlo varies across a variety of systems, provide new perspectives on the origins of the fixed-node biases in calculations of molecular and condensed systems, and carry implications for pseudopotential constructions for heavy elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The importance of matched poloidal spectra to error field correction in DIII-D

Optimal error field correction (EFC) is thought to be achieved when coupling to the least-stable “dominant” mode of the plasma is nulled at each toroidal mode number (n). The limit of this picture is tested in the DIII-D tokamak by applying superpositions of in- and ex-vessel coil set n = 1 fields calculated to be fully orthogonal to the n = 1 dominant mode. In co-rotating H-mode and low-density Ohmic scenarios, the plasma is found to be, respectively, 7× and 20× less sensitive to the orthogonal field as compared to the in-vessel coil set field. For the scenarios investigated, any geometry of EFC coil can thus recover a strong majority of the detrimental effect introduced by the n = 1 error field. Despite low sensitivity to the orthogonal field, its optimization in H-mode is shown to be consistent with minimizing the neoclassical toroidal viscosity torque and not the higher-order n = 1 mode coupling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗