Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

KEPLER INPUT CATALOG: PHOTOMETRIC CALIBRATION AND STELLAR CLASSIFICATION

We describe the photometric calibration and stellar classification methods used by the Stellar Classification Project to produce the Kepler Input Catalog (KIC). The KIC is a catalog containing photometric and physical data for sources in the Kepler mission field of view; it is used by the mission to select optimal targets. Four of the visible-light (g, r, i, z) magnitudes used in the KIC are tied to Sloan Digital Sky Survey magnitudes; the fifth (D51) is an AB magnitude calibrated to be consistent with Castelli and Kurucz (CK) model atmosphere fluxes. We derived atmospheric extinction corrections from hourly observations of secondary standard fields within the Kepler field of view. For these filters and extinction estimates, repeatability of absolute photometry for stars brighter than magnitude 15 is typically 2%. We estimated stellar parameters {l_brace}T{sub eff}, log (g), log (Z), E{sub B-V}{r_brace} using Bayesian posterior probability maximization to match observed colors to CK stellar atmosphere models. We applied Bayesian priors describing the distribution of solar-neighborhood stars in the color-magnitude diagram, in log (Z), and in height above the galactic plane. Several comparisons with samples of stars classified by other means indicate that for 4500 K {<=}T{sub eff} {<=} 6500 K, our classifications are reliable within about {+-}200 K and 0.4 dex in log (g) for dwarfs, with somewhat larger log (g) uncertainties for giants. It is difficult to assess the reliability of our log (Z) estimates, but there is reason to suspect that it is poor, particularly at extreme T{sub eff}. Comparisons between the CK models and observed colors are generally satisfactory with some exceptions, notably for stars cooler than 4500 K. Of great importance for the Kepler mission, for T{sub eff} {<=} 5400 K, comparison with asteroseismic results shows that the distinction between main-sequence stars and giants is reliable with about 98% confidence. Larger errors in log (g) occur for warmer stars, for which our filter set provides inadequate gravity diagnostics. The KIC is available through the MAST data archive.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of Ferrihydrite-Coated Pozzolana and Biogenic Green Rust to Purify Waste Water Containing Phosphate and Nitrate

The activated sludge treatments combined to the addition of ferric chloride is commonly used to eliminate nitrate and phosphate from waste water in urban area. These processes that need costly infrastructures are not suitable for rural areas and passive treatments (lagoons, reed bed filters…) are more frequently performed. Reed bed filters are efficient for removing organic matter but are not suitable for treating phosphate and nitrate as well. Passive water treatments using various materials (hydroxyapatite, slag…) were already performed, but those allowing the elimination of both nitrate and phosphate are not actually available. The goal of this work is to identify the most suitable iron based materials for such treatments and to determine their optimal use conditions, in particular in hydrodynamic mode. The reactivity of the iron based minerals was measured either by using free particles in suspension or by depositing these particles on a solid substrate. Pouzzolana that is characterized by a porous sponge-like structure suits for settling a high amount of iron oxides. The experimental conditions enabling to avoid any ammonium formation when green rust encounters nitrate were determined within the framework of a full factorial design. The process is divided into two steps that will be performed inside two separated reactors. Indeed, the presence of phosphate inhibits the reduction of nitrate by green rust and the dephosphatation process must precede the denitrification process. In order to remove phosphate, ferrihydrite coated pouzzolana is the best materials. The kinetics of reaction of green rust with nitrate is relatively slow and often leads to the formation of ammonium. The recommendation of the identified process is to favor the accumulation of nitrite in a first step, these species reacting much more quickly with green rust and do not transform into ammonium.

Environmental Molecular Sciences Laboratory↗

Fully Integrated Applications of Thin Films on Low Temperature Cofired Ceramic (LTCC)

Thin film multilayers have previously been introduced on multilayer low temperature cofired ceramic (LTCC), as well as initial thin film capacitors on LTCC. The ruggedness of a multipurpose Ti-Cu-Pt-Au stack for connectivity and RF conductivity has continued to benefit fabrication and reliability in state of-the-art modules, while the capacitors have followed the traditional Metal-Insulator-Metal (MIM) style. The full integration of thin film passives with thin film connectivity traces is presented. Certain passives, such as capacitors, require specifically tailored and separately patterned thin film (multi-)layers, including a dielectric. Different capacitance values are achieved by variation of both the insulator layer thickness and the active area of the capacitor. Other passives, such as filters, require only the conductor - a single thin film multilayer. This can be patterned from the same connectivity thin film material (Ti-Cu-Pt-Au), or a specially tailored thin film material (e.g. Ti-Cu-Au) can be deposited. Both versions are described, including process and integration details. Examples are discussed, ranging from patterning for maximum tolerances, to space and performance-optimized designs. Cross-sectional issues associated with integration are also highlighted in the discussion.

36 MATERIALS SCIENCE↗

Controlling mercury emissions from coal-fired power plants

Increasingly stringent US federal and state limits on mercury emissions form coal-fired power plants demand optimal mercury control technologies. This article summarises the successful removal of mercury emissions achieved with activated carbon injection and boiler bromide addition, technologies nearing commercial readiness, as well as several novel control concepts currently under development. It also discusses some of the issues standing in the way of confident performance and cost predictions. In testing conducted on western coal-fired units with fabric filters or TOXECON to date, ACI has generally achieved mercury removal rates > 90%. At units with ESPs, similar performance requires brominated ACI. Alternatively, units firing western coals can use boiler bromide addition to increase flue gas mercury oxidation and downstream capture in a wet scrubber, or to enhance mercury removal by ACI. At eastern bituminous fired units with ESPs, ACI is not as effective, largely due to SO{sub 3} resulting from the high sulfur content of the coal or the use of SO{sub 3} flue gas conditioning to improve ESP performance. 7 refs., 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Phase segregation mechanisms of small molecule-polymer blends unraveled by varying polymer chain architecture

As phase separation between the small-molecule semiconductor and the polymer binder is the key enabler of blend-based organic field-effect transistors (OFETs) fabricated by low-cost solution processing, it is crucial to understand the underlying phase separation mechanisms that determine the phase morphology, which significantly impacts device performance. Beyond the parameter space investigated in previous work, here we investigate the formation of blends by varying the branch architecture of the polymer binder and by shortening the solvent dry time using ultrasonic spray casting. The phase morphologies of the resulting blend films have been thoroughly characterized with a variety of techniques in three dimensions over multiple length scales, including AFM, energy-filtered transmission electron microscope, and neutron reflectivity, and have been correlated with electrical transport performance. From the results, we have inferred that the phase morphology is kinetically determined, limited by the inherent slow movement of polymer macromolecules. The kinetic picture, supported by molecular dynamics modeling, not only consistently explains our observations but also resolves inconsistencies in previous works. The achieved mechanistic understanding will guide further optimization of blend-based organic electronics, such as OFETs and organic photovoltaics.

36 MATERIALS SCIENCE↗

Material erosion measurements and expected operational lifetime of a deployable photon sieve payload

Spacecraft operating in low-Earth orbit are subjected to a number of hazardous environmental constituents that can lead to decreased system performance and reduced operational lifetimes. Due to their thermal, optical, and mechanical properties, polymers are used extensively in space systems; however they are particularly susceptible to material erosion and degradation as a result of exposure to the LEO environment. The focus of this research is to examine the material erosion and mass loss experienced by a custom Kaptonlike polyimide due to exposure in a simulated low-earth orbit environment. The deployable membrane telescope design discussed in this research is named Peregrine and is the scientific payload for FalconSat-7, a 3U cubesat designed and developed at the United States Air Force Academy (USAFA) for the purpose of demonstrating the capability of deployable membrane telescope technology on a nanosatellite platform. In addition to the polymer samples, chrome, silver and gold specimens will be examined to measure the oxidation rate and act as a control specimen, respectively. A magnetically filtered atomic oxygen plasma source has previously been developed and characterized for the purpose of simulating the low-Earth orbit environment. The plasma source can be operated at a variety of discharge currents and gas flow rates, of which the plasma parameters downstream of the source are dependent. The characteristics of the generated plasma were examined as a function of these operating parameters to optimize the production of O + ions with energy relevant to LEO applications. The erosion yield of the Kapton-like polyimide was experimentally determined to be 2.84 x 10 -24 cm 3 per atom which is in close agreement when compared to the on-orbit measurement for reaction efficiency of Kapton HN. We report the experimentally determined reaction rate for the Kapton-like polyimide was used to estimate the operational lifetime of the photon sieve during the solar conditions expected beginning in May 2019. The effective lifetime is estimated between 126 and 153 days.

36 MATERIALS SCIENCE↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-207A-01: A Novel Maximum Likelihood Method for High-Resolution Proton Radiography/proton CT

Purpose: Multiple Coulomb scattering is the largest contributor to blurring in proton imaging. Here we tested a maximum likelihood least squares estimator (MLLSE) to improve the spatial resolution of proton radiography (pRad) and proton computed tomography (pCT). Methods: The object is discretized into voxels and the average relative stopping power through voxel columns defined from the source to the detector pixels is optimized such that it maximizes the likelihood of the proton energy loss. The length spent by individual protons in each column is calculated through an optimized cubic spline estimate. pRad images were first produced using Geant4 simulations. An anthropomorphic head phantom and the Catphan line-pair module for 3-D spatial resolution were studied and resulting images were analyzed. Both parallel and conical beam have been investigated for simulated pRad acquisition. Then, experimental data of a pediatric head phantom (CIRS) were acquired using a recently completed experimental pCT scanner. Specific filters were applied on proton angle and energy loss data to remove proton histories that underwent nuclear interactions. The MTF10% (lp/mm) was used to evaluate and compare spatial resolution. Results: Numerical simulations showed improvement in the pRad spatial resolution for the parallel (2.75 to 6.71 lp/cm) and conical beam (3.08 to 5.83 lp/cm) reconstructed with the MLLSE compared to averaging detector pixel signals. For full tomographic reconstruction, the improved pRad were used as input into a simultaneous algebraic reconstruction algorithm. The Catphan pCT reconstruction based on the MLLSE-enhanced projection showed spatial resolution improvement for the parallel (2.83 to 5.86 lp/cm) and conical beam (3.03 to 5.15 lp/cm). The anthropomorphic head pCT displayed important contrast gains in high-gradient regions. Experimental results also demonstrated significant improvement in spatial resolution of the pediatric head radiography. Conclusion: The proposed MLLSE shows promising potential to increase the spatial resolution (up to 244%) in proton imaging.

60 APPLIED LIFE SCIENCES↗

GPU/MIC Acceleration of the LHC High Level Trigger to Extend the Physics Reach at the LHC

The quest for rare new physics phenomena leads the PI to propose evaluation of coprocessors based on Graphics Processing Units (GPUs) and the Intel Many Integrated Core (MIC) architecture for integration into the trigger system at LHC. This will require development of a new massively parallel implementation of the well known Combinatorial Track Finder which uses the Kalman Filter to accelerate processing of data from the silicon pixel and microstrip detectors and reconstruct the trajectory of all charged particles down to momentums of 100 MeV. It is expected to run at least one order of magnitude faster than an equivalent algorithm on a quad core CPU for extreme pileup scenarios of 100 interactions per bunch crossing. The new tracking algorithms will be developed and optimized separately on the GPU and Intel MIC and then evaluated against each other for performance and power efficiency. The results will be used to project the cost of the proposed hardware architectures for the HLT server farm, taking into account the long term projections of the main vendors in the market (AMD, Intel, and NVIDIA) over the next 10 years. Extensive experience and familiarity of the PI with the LHC tracker and trigger requirements led to the development of a complementary tracking algorithm that is described in [arxiv: 1305.4855], [arxiv: 1309.6275] and preliminary results accepted to JINST.

97 MATHEMATICS AND COMPUTING↗

Mineral Selection for Multicomponent Equilibrium Geothermometry

Multicomponent geothermometry requires knowledge of the mineral phases in the reservoir with which the geothermal fluids may be equilibrated. These minerals phases are most often alteration products rather than primary minerals. We have reviewed the literature on geothermal systems representing most major geologic environments typically associated with geothermal activity and identified potential alteration products in various environments. We have included this information in RTEst, a code we have developed to estimate reservoir conditions (temperature, CO 2 fugacity) from the geochemistry of near-surface geothermal waters. The information has been included in RTEst through the addition of filters that decrease the potential number of minerals from all possibilities based on the basis species to those that are more relevant to the particular conditions in which the user is interested. The three groups of filters include host rock type (tholeiitic, calc-alkaline, silicic, siliciclastic, carbonate), water type (acidic, neutral), and the temperature range over which the alteration minerals were formed (low, medium, high). The user-chosen mineral assemblage is checked to make sure that it does not violate the Gibbs phase rule. The user can select one of three mineral saturation weighting schemes that decrease the chance the optimization from being skewed by reaction stoichiometry or analytical uncertainty.

15 GEOTHERMAL ENERGY↗

Instrumentation for a multichord motional Stark effect diagnostic in KSTAR

The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1–3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18A-08: Effect of Quantum Detection Efficiency and Energy Bin Selection On Contrast-To-Noise-Ratio for Energy-Resolved Photon-Counting Detectors

Purpose: Energy-resolved photon-counting detectors have the capability to discriminate photons according to their energies. By using optimal energy weighting factors, the contrast-to-noise-ratio (CNR) of the reconstructed image can be improved. In this work, we investigate how quantum detection efficiency (QDE) affects the determination of the optimal energy threshold bins, and therefore the CNR improvement of photon-counting detectors. Methods: In this simulation study a photon-counting detector, based on Silicon (Si), was investigated. A task-oriented algorithm was used to determine the optimal energy bin setting in order to maximize CNR. Projection-based and Image-based energy weighting techniques were implemented. A 13 mm PMMA phantom with two contrast materials, hydroxyapatite (HA) and iodine (I), at different concentrations (100, 200, and 300 mg/mL for HA and 2, 4, and 8 mg/mL for I) was used. TASMIP algorithm was used to generate the spectrum with 2.7 mm Al filter. Different tube voltages, number of energy bins, and bin widths were investigated. Different thicknesses of Si were also investigated to determine the QDE effect on CNR. Results: CNR increased as the detector material thickness increased until it reached 30 mm for Si thickness such that the CNR value was near to the value predicted by an ideal detector. Also, the results indicated that the improvement of CNR due to the QDE is task-dependent when comparing weighted images to photon-counting images. For hydroxyapatite the improvement is approximately 20%, whereas for iodine it is less than 10%. Conclusion: The results showed that the improvement of CNR for an energy-resolved photon-counting detector is highly task-dependent when QDE is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effectiveness of copper and bronze for zinc capture

A series of experiments was conducted to determine the efficacy of using copper and bronze sheet and screen under high vacuum conditions to capture zinc vapor. The experiments were conducted in a parametric manner using a fixed zinc vaporization temperature (350°C) but varying the filter temperature from ambient to 550°C. Consistent with previous work, metallic zinc was deposited at low temperatures, but the deposit was non-adherent. At an intermediate temperature range (350-450°C), the deposit formed an alloy with both copper and bronze materials. At higher temperatures (> 500°C) the zinc did not deposit on the surfaces likely due to its high vapor pressure. Additional testing to optimize the zinc &#x27;getter&#x27; chemistry and surface condition is warranted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive enough for use in SRS and SBRT QA. The lower gamma pass rate for Presage compared to Gafchromic film can be attributed to the simple equipment used in the fabrication process, which limited the dosimeter’s sensitivity uniformity by agglomeration of air bubbles in the material, nonuniform concentration of chemicals throughout the material, and thickness variations. This demands improvements in mixing tools and molds.

60 APPLIED LIFE SCIENCES↗

Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program

Purpose: Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides dose and risk estimates specific to each patient and each CT examination. As the first step toward patient-specific dose and risk estimation, this article aimed to develop a method for accurately assessing radiation dose from CT examinations. Methods: A Monte Carlo program was developed to model a CT system (LightSpeed VCT, GE Healthcare). The geometry of the system, the energy spectra of the x-ray source, the three-dimensional geometry of the bowtie filters, and the trajectories of source motions during axial and helical scans were explicitly modeled. To validate the accuracy of the program, a cylindrical phantom was built to enable dose measurements at seven different radial distances from its central axis. Simulated radial dose distributions in the cylindrical phantom were validated against ion chamber measurements for single axial scans at all combinations of tube potential and bowtie filter settings. The accuracy of the program was further validated using two anthropomorphic phantoms (a pediatric one-year-old phantom and an adult female phantom). Computer models of the two phantoms were created based on their CT data and were voxelized for input into the Monte Carlo program. Simulated dose at various organ locations was compared against measurements made with thermoluminescent dosimetry chips for both single axial and helical scans. Results: For the cylindrical phantom, simulations differed from measurements by -4.8% to 2.2%. For the two anthropomorphic phantoms, the discrepancies between simulations and measurements ranged between (-8.1%, 8.1%) and (-17.2%, 13.0%) for the single axial scans and the helical scans, respectively. Conclusions: The authors developed an accurate Monte Carlo program for assessing radiation dose from CT examinations. When combined with computer models of actual patients, the program can provide accurate dose estimates for specific patients.

60 APPLIED LIFE SCIENCES↗

Si quantum dots in silicon nitride: Quantum confinement and defects

Luminescence of amorphous Si quantum dots (Si QDs) in a hydrogenated silicon nitride (SiN{sub x}:H) matrix was examined over a broad range of stoichiometries from Si{sub 3}N{sub 2.08} to Si{sub 3}N{sub 4.14}, to optimize light emission. Plasma-enhanced chemical vapor deposition was used to deposit hydrogenated SiN{sub x} films with excess Si on Si (001) substrates, with stoichiometry controlled by variation of the gas flow rates of SiH{sub 4} and NH{sub 3} gases. The compositional and optical properties were analyzed by Rutherford backscattering spectroscopy, elastic recoil detection, spectroscopic ellipsometry, photoluminescence (PL), time-resolved PL, and energy-filtered transmission electron microscopy. Ultraviolet-laser-excited PL spectra show multiple emission bands from 400 nm (3.1 eV) to 850 nm (1.45 eV) for different Si{sub 3}N{sub x} compositions. There is a red-shift of the measured peaks from ∼2.3 eV to ∼1.45 eV as Si content increases, which provides evidence for quantum confinement. Higher N content samples show additional peaks in their PL spectra at higher energies, which we attribute to defects. We observed three different ranges of composition where Tauc band gaps, PL, and PL lifetimes change systematically. There is an interesting interplay of defect luminescence and, possibly, small Si QD luminescence observed in the intermediate range of compositions (∼Si{sub 3}N{sub 3.15}) in which the maximum of light emission is observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗